Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.0 LAccepted-AOC | L1 | Accepted-AOC ok | |
| 2 | L2₹18.0 L+₹98,324.62 (5.77%)Rejected-AOC H NO244 JHAMOLA 126101 | JHAMOLA | JIND | HARYANA | 126101 | L2 | Rejected-AOC ok | |
| 3 | L3₹18.3 L+₹1.2 L (7.13%)Rejected-AOC THE CHEVISH CO OP L AND C SOCIETY LTD ALAWLA VPO ALAWLA TEHSIL ASSANDH DISTRICT KARNAL 132036 | ALAWLA | KARNAL | HARYANA | 132036 | L3 | Rejected-AOC ok | |
| 4 | L4₹18.7 L+₹1.7 L (9.73%)Rejected-AOC 5 NEAR GOVT SR SEC SCHOOL VILLAGE BARAGAON KARNAL 132023 | KARNAL | KARNAL | HARYANA | 132023 | L4 | Rejected-AOC ok | |
| 5 | L5₹19.3 L+₹2.3 L (13.2%)Rejected-AOC A 20 YAMUNA ENCLAVE PANIPAT 132103 | PANIPAT | PANIPAT | HARYANA | 132103 | L5 | Rejected-AOC ok |
Tender Value
₹20.9 L
EMD Value
₹41,831
Closing Date
7 Apr 2025, 11:00 amClosed
YOGESH
MICAD Division Kaithal
Solar Power Pressurized Irrigation at Overflowing village Pond of Pharal Distt. Kaithal.Chapparwala Pond
2025_HBC_437009_1
20252BCF4094 AFB6 485A 966A 9E4DE72F35171625CAD
Open Tender
Civil Works
Works
365 days
PHARAL
Pharal
3 documents required · 3 mandatory
₹1,000
₹41,831
Yes
30 Apr 2025
28 Mar 2025
7 Apr 2025
28 Mar 2025
7 Apr 2025
28 Mar 2025
28 Mar 2025 - 30 Mar 2025
Amount
Supplying,erection, testing and commissioning of solar AC open-well Submersible Pump set with tree phase motor having casing of Alloy Steel for the required power capacity, dicharge and Head including all PVC insulated polymer sheathed 3 core flat type cabling in coduit .required from solar palnt to solar pump through control room.
Supplying ,erection, testing and commissioning of Variable Frequency drive (VFD) complete with all accessories for the required power capacity of solar Pump
Providing, laying, aligning, and jointing with uPVC heavy body solvent at all level/ depths of Type B, Class-2 ISI marked 125 mm o/d uPVC pipe of pressure 4 kg/cm2 as per design for raw water supply as per IS 4985:2021 (amended up to date) in trenches in complete, including cost of all Specials, labour, and commissioning as per Technical Specifications and approved make as per direction of Engineer. Rate includes cost of all special like bends, tees required during laying of pipeline along required alignment.
Providing and fixing tank type( make of metal) Fertilizer and chemical injector system confirming to IS 14483 (Part3 ) of 2018 for demnstration and guiding the farmers regarding fertilization and chemicalisation of system. (rate include ventury with manifold 1.0'=1300 and 60 ltre fertilizer tank=4400)
Horizontal directional drilling with micro tunnelling methods, for pipe laying under pucca rasta/road crossing.
Providing and lowering of HDPE floater manufactured with 225 mm dia PE pipe having PE-80 and PN-10 to float the submersible open well pump/motor
Galvanized steel chain link both end twisted fence fabric having opening size 7.5x7.5 cm and 3.15 mm dia wire, 2.2 meter height of mesh, with 2.8 meter ht of MS Angle 50x50x5 mm supports fixing at spacing of 3 meter centre to centre, supports with MS Flat 35x5 mm. Fencing supported with MS Angle 35x35x5 at top and bottom. The M.S Angle supports shall be anchored in cement concrete (1:3:6) blocks 45x45x60 cm additional razor barbed wire fencing shall be provided at the top of mesh, fencing including gate @Rs 2000/- per meter
Supply Installation testing commissioning of Solar Photovoltaic Stand alone Plant conforming to MNRE specifications as amended, consisting of Mono Crystalline silicon solar cells, necessary protections, earthing, mounted on Aluminium/GI structure of suitable strength. Including lightning and surge voltage protection, Fixing of Array junction box and Main junction box with IP 65 protection and termination arrangement for incoming and outgoing cable along with glands, lugs and other accessories etc. as required, built in metering system to moniter plant performence (Amp-meter, Volt-meter, Frequency meter, Energy meter, Watt-meter, and other instrument/equipment as required) Note:- PV modules used must qualify to the latest edition of IEC PV module qualification test or equivalent BIS standards Mono Crystalline Silicon Solar Cell Modules IEC 61215/IS14286. In addition, the modules must conform to IEC 61730 Part-1- requirements for construction and Part 2 – requirements for testing, for safety qualification or quivalent IS and be mounted on fixed Aluminium/GI structure of adequate strength and design as per IEC/IS specification. Including field-based electroluminescence (EL) study be performed after receiving the modules at site and after installation. Module mounting structure (MMS) design and drawing shall be duly vetted from government institute Including third party inspection Actual parameters/capacity will be finalized after approval of design and drawing.
Providing and fixing 12 Watt LED Street Lighting of 75 watt solar panel, 12.8 volt 30 Ah Lithium Ferro Phosphate battery, 12 Watt White LED Luminaire and Pole of 5 Meter above ground level with dusk to dawn operation {first 4 hours full light System ding, fixing and testing of Solar light including battery: min. 24 lux) , rest of the time at lower light (50% Min. 12 lux) level} and 3 days or minimum 36 operating hours autonomy or as per direction of engineer-in-charge
Hydrant assembly for Nakka in fields, Rates including Tee, riser pipe, butterfly valve, Flange and labour for fixing butter fly valve should be as per IS 13095-2020
Providing, fixing,testing and commissioning of pressure gauge 2` dial with Glycerin filled to be fixed before and after filtration unit.
Providing fixing of 110 mm HDPE pipe (for jointing loater, all filters, PRV etc) PE-80 grade. ,SDR 17 and PN 6DN 110 mm per design for porable water supply as per IS 4984-2016 (amended upto date) in trenches in complete , including cost of PE specials, labour, sectional hydro testing (including the cost and conveyance of water to site for testing) and commissioning as per Technical Specifications and as per direction of Engineer including cost of all special like bends, tees required during laying of pieline along required alignment.
Providing fixing of Header Assembly/Manifold 3` to (loose)
Construction of 8`x8` control room constructed with 9` thick brick masonary inner side covered with 6' thick RCC slab in 1:1,5:3 concrete slab of size 9.5'X12' mix with proper door and 2 No. windows and electric installation as per approved design and drawing inner size 8`x8` Av. Height 9` from DPC level completed in all respect.
Bidder Name
Amount
THE JAI MAHAKALL CO-OP L AND C SOCIETY LTD (GSTN-NA) BID ID -1236475
The Raghav Coop Labour & Construction Society Ltd Karnal (GSTN-NA) BID ID -1233917
THE KISAN CO-OPERATIVE L AND C SOCIETY LTD JHAMOLA (GSTN-NA) BID ID -1236784
The Chevish Coop. L&C Society Ltd. Alawla (GSTN-NA) BID ID -1236673
The Solanki Coop L&C Soc. Ltd. (GSTN-NA) BID ID -1234377
THE KISAN CO-OPERATIVE L AND C SOCIETY LTD JHAMOLA (BID ID -1236784)
The Chevish Coop. L&C Society Ltd. Alawla (BID ID -1236673)
THE JAI MAHAKALL CO-OP L AND C SOCIETY LTD (BID ID -1236475)
The Raghav Coop Labour & Construction Society Ltd Karnal (BID ID -1233917)
The Raghav Coop Labour & Construction Society Ltd Karnal (BID ID -1233917)
THE KISAN CO-OPERATIVE L AND C SOCIETY LTD JHAMOLA (BID ID -1236784)
The Chevish Coop. L&C Society Ltd. Alawla (BID ID -1236673)
THE JAI MAHAKALL CO-OP L AND C SOCIETY LTD (BID ID -1236475)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .