Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.5 LAccepted-AOC | L1 | Accepted-AOC Lowest Bidder. | |
| 2 | L2₹19.8 L+₹2.3 L (13.3%)Rejected-Finance | L2 | Rejected-Finance Not being L1 | |
| 3 | L3₹20.2 L+₹2.7 L (15.7%)Rejected-Finance PLOT NO 79 SIS PARK DICHAON ENCLAVE PP2914 NAJAFGARH SOUTH WEST DELHI NEW DELHI 110043 | WEST DELHI | DELHI | 110043 | L3 | Rejected-Finance Not being L1 | |
| 4 | L4₹21.8 L+₹4.3 L (24.6%)Rejected-Finance 1ST FLOOR H NO 165 GALI NO 16 S B S COLONY KARAWAL NAGAR DELHI EAST DELHI DELHI 110094 | NORTH EAST DELHI | DELHI | 110094 | L4 | Rejected-Finance Not being L1 | |
| 5 | L5₹23.9 L+₹6.4 L (36.8%)Rejected-Finance RAMA PARK A 121 BLOCK A UTTAM NAGAR WEST DELHI DELHI 110059 | DELHI | WEST DELHI | DELHI | 110059 | L5 | Rejected-Finance Not being L1 |
Tender Value
₹49 L
EMD Value
₹98,000
Closing Date
5 Jul 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE South Delhi Cantt-10
GE South Delhi Cantt-10
WELCOME MAINT AND OTHER CONNECTING ITEMS TO ANUJ VIHAR OFFRS MD ACCN IN THE AOR OF AGE B/R-I AND AGE E/M UNDER GE (SOUTH) DELHI CANTT-10
2024_MES_659972_1
GE/DS-35/2024-25
Open Tender
Civil Works
Item Rate
270 days
GE South Delhi Cantt
Please refer Tender documents.
11 documents required · 11 mandatory
₹500
GE South Delhi Cantt
₹98,000
23 Sept 2024
14 Jun 2024
12 Jul 2024
14 Jun 2024
5 Jul 2024
28 Jun 2024
Amount
Taking down cement plaster on brick walls including raking out joints, hacking for key, scrubbing down with water complete all as specified and as directed.
M&L for 10 mm thick rendering internal with ready mix plaster ( as manufacturr's instructions ) in patches on faces of bricks or concrete surfaces , finished even and smooth without without using extra cement ,complete all as specified and directed by Engr-in-Charge. Make : Birla Aerocon / Ultra radiplast / ACC Acoplast.
M&L 5 mm thick rendering on ceiling with ready mix plaster ( as manufacturr's instructions ) in patches on faces of bricks or concrete surfaces , finished even and smooth without without using extra cement ,complete all as specified and directed by Engr-in-Charge. Make : Birla Aerocon / Ultra radiplast / ACC Acoplast.
M&L for complete removal of existing treatment (OBD/oil paint/white wash etc) by scrapping with mechanical wall sander on wall/ceiling (having mechanical vaccum mechanism) having RPM not less than 1500, sanding pad of 80 grit having dia of 7"/9" to make the surface free from dust, loose paint.removal of nails etc & filling cracks/hole & windows/doors jams repair in good shape by skilled labour and including removal/ sifting of house hold furniture/items wherever required and cleaninig of door,windows, floor and furnituresetc.complete all as specified and as directed.
M&L for waterproof cement based putty @ 1 Kg (undiluted) per sqm of average thickeness 1mm over the plastered/old painted wall/ceiling after scrapping to prepare the surface with machenical wall sander (having mechanical vaccum mechanism) having RPM not less than 1500, sanding pad of 240 grit or above to make the surface free from dust etc. by skilled labour as per following steps:- Step 1) Mix the putty powder by adding water as per manufacturer instructions and mix it with putty mixer with the mixing capacity of min 2.5 kg putty per minute. Step 2) Applying the first coat the prepared mixer with the help of fully autometic airless spray machine of putty application having flow speed of max 6 ltrs per minutes with a miximum pressure 3300 PSI Step 3) Allow 6-8 hrs time to dry the putty surface.
M&L for applying two coats of oil bound distemper on wall/ceiling using Airless spray technology with max working pressure of 3300 PSI and capable of operating single spray gun with a max material hose langth of 30 mtr the spray machine should be of reputed manufacturer with pro guard technology and capability of tracking pressure and paint usage and certified by pain manufacturer and as mentioned in PS and accessories for applying distemper should be able to spray in hard to reach areas and penetration of distemper on the surface complete all as secified and directed. Note: Sanding of surface to be done by mechanical sander with 150 - 2700 rpm, with internal dust extraction system for clean environment certified by paint manufacturer including removal/ sifting of firniture and cleaninig of door,windows, floor and furnituresetc.
M&L for preparation of old decorated surfaces of Wall (plastered or unplastered) including cornices pillasters and other wall features by Vacuum based sanding machine complete all as specified smoke, soot moulds and efflorescent salt and trading oil or greasy spots applying one coat of white wash to obtain uniform surfaces including scafolding arrangement, trestles, ladders etc. complete all as specified and as directed.
M&L for preparation of old decorated surfaces of Ceiling (plastered or unplastered) including cornices pillasters and other wall features by Vacuum based sanding machine complete all as specified smoke, soot moulds and efflorescent salt and trading oil or greasy spots applying one coat of white wash to obtain uniform surfaces including scafolding arrangement, trestles, ladders etc. complete all as specified and as directed.
M&L for preparation of old painted surfaces of wood & wood based surface of any description not otherwise described over 10 cm width & girth and applying one coat of synthetic enamel paint complete all as specified and as directed.
M&L for preparation of old painted surfaces of steel & steel based surface of any description not otherwise described over 10 cm width & girth and applying one coat of synthetic enamel paint complete all as specified and as directed.
M&L for preparing of old decorated surfaces of (Plastered or unplastered) including cornices pillasters and other wall features by washing, rubbing down and stopping of distempered and painted surfaces of Walls/Ceiling and applying one coat of oil emulsion distemper white or tinted in patches of area exc 0.5 Sqm and n.exc 2.50 Sqm each to match the existing surface including scaffolding arrangement, trestles, ladders etc. complete all as specified and as directed.
Taking down chowkhats or frames with shutter exc 1.5 sqm but not exc 4 sqm each but without taking off shutters from the frame.
S&F factory made uPVC white colour Three track three panels sliding Door with fly proof S.S. wire mesh (Two nos. glazed & one no. wire mesh panels) made of (big series) frame 116 x 45 mm & sash 46 x 82 mm both having wall thickness of 2.3 + 0.2 mm and single glazing bead/ double glazing bead of appropriate dimension. (Area of door above 2.00 sqm upto 5.00 sqm) comprising of uPVC chambered frame, with in-built roller track and sash extruded profiles duly reinforced with 1.60 + 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension uPVC extruded glazing beads, uPVC extruded interlock and uPVC extruded Inline sash adaptor (if required), EPDM gasket, wool pile, zinc alloy (white powder coated) handle with key on one side of extreme panels along with zinc plated mild steel multi point locking having transmission gear with keeps, zinc alloy (white powder coated) cresent lock (if required).stainless steel (SS 304 grade) body with adjustable double nylon rollers (weight bearing capacity to be 120 kg), G.I fastener 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, complete all as specified and direct. Note: (i) For PVC frame and sash extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. (ii) The rate quoted by the tenderer are also included for necessary rolling track hinges and iron moongeries, however Glass or wiremesh shall be paid separately.
S&F 5mm thick toughned glassfixed with uPVC doos and windows including all necessary fittings. Complete all as specified and as directed.
S&F galvanised mild steel wire cloth 0.56 mm nominal dia of wire and average width of aperture 1.18mm and fixed with tied tacks or galvanised wire stapple etc. to uPVC doors and windows complete all as specified and as directed.
S&F in repairs brass chromium plated bib tap long body of 15mm bore fancy type fixed to iron pipe complete all as specified and as directed.
S&F in repairs 15mm dia brass chromium plated pillar tap with fly nuts capastan head screwed down high pressure with or without lettered hot or cold with long scewed shank complete all as specified and as directed.
S&F in repairs chromium plated brass stop cock fancy type (concealed type)screwed both ends high pressure for 15mm bore size iron pipe or ferrule complete all as specified and as directed.
S&F in repairs chromium plated brass angle valve fancy type suitable for 15mm bore pipe complete all as specified and as directed.
S&F in repair chromium plated brass shower rose swival type 50mm with arm fancy type suitable for 15mm bore pipe complete all as specified and as directed.
S&F in repairs PVC connection 450mm long with 2 Nos brass check nuts suitable for 15mm bore of pipe with washer complete all as specified and as directed.
S&F in repairs waste fitting (coupling) brass chromium plated 32mm dia for WHB complete all as specified and as directed.
S&F in repairs 10 ltrs PVC (White) valve less syphonic action type, flushing cistern low level with inlet ball valve float, handle, Aluminium brackets for bottom support fixing with gitties embeded in wall with drilling machine etc. complete all as specified and as directed.
S&F in repairs 15mm dia wash hand basin CP brass mixer as complete all as specified and as directed.
S&F in repairs 32/40mm bore and 75cm long PVC waste pipe suitable for WHB/Sink complete all as specified and as directed.
S&F in repairs brass chromium plated health faucet for WC with 1.20 Mtr long PVC flexible pipe complete all as specified and as directed.
S&F in repairs soap dish chromium plated brass fixed with brass nuts and screws as in repair complete all as specified and as directed.
S&F in repairs toilet paper holder brass chromium plated as in repair complete all as specified and as directed.
S&F in repairs plastic water closet (EWC) seat cover white closed pattern with flat bottom and cover incl mild steel chromium plated hinging device complete all as specified and as directed.
S&F in repairs viterous china wash down water closet pan (EWC) white incl 'P' or 'S' trap and making good the disturbed surface to match with the existing complete all as specified and as directed.
S&F in repairs vitreous china squatting pan (Orissa pattern) long pan including provision of lime concrete bedding fixed in repair size 580x440mm white with intergral footrest with 'P' or 'S' trap complete all as specified and as directed.
S&F in repairs vitreous china wash hand basin, white flat back size 550x400mm (excluding taps, waste, pipe chain and plug) but including porcelain stopper and a pair of MS bracket etc complete all as specified and as directed.
Taking down copper point wiring (light, fan, socket or power and including all fitting ) for taking credit and making good disturbed surfaces of walls, floors etc.
M&L for point wiring complete, standard copper conductor 1.5 Sqmm nominal area PVC insulated FR-LS 1100 volts grade electrical cable in and including suitable size of concealed/surface PVC conduit/ casing caping medium grade and sunk in pressed steel terminal boxes of required size with top cover 3 mm thick plastic/laminated sheet of required color with screwed and cup washer complete with all accessories including 1.5 Sqmm standard copper conductor PVC unsheathed cable earth and connected to earth dolly complete all as specified and as directed. Note :- In existing conduit wiring new conduit will be added where there is a burnt/blokage/damage to the existing conduit including bends/elbows/tees/Junction boxes. (a) One light / fan/bell point controlled by one switch SP, one way,
All as above Srl item No. 36 above but one 3 pin socket outlet 5/6 Amps on same board.
All as above Srl item No. 36 above but one socket outlet 5/6 Amps on independent boardwith cable 2.5 Sqmm for phase & neutral and for earth 2.5 sqmm.
All as above Srl item No. 36 above but here-in-before one power socket 15/16 Amp with cable 2.5 Sqmm for phase & neutral and for earth 2.5 sqmm.
S&F in repairs of switch piano flush type 6 Amps SP one way complete all as specified and as directed.
S&F in repairs of switch piano flush type 6 Amps SP 2-way complete all as specified and as directed.
S&F in repairs bell push, flush type 6 Amps complete all as specified and as directed.
S&F in repairs of socket outlet 6 Amps flush type 3 pin complete all as specified and as directed.
S&F in repairs of switch piano type 16 Amps SP one way complete all as specified and as directed.
S&F in repairs of socket outlet 2 in 1 (multipurpose) 6 pin 6 and 16 Amps flush mounted type complete all as specified and as directed.
S&F in repairs of switch socket combination 2-in-1, 6 Amps with gang box flush type complete all as specified and as directed.
S&F in repairs of switch socket combination 2-in-1 6 & 16 Amps with gang box flush type complete all as specified and as directed.
S&F in repairs of switch socket combination 2-in-1, 6 Amps flush type complete all as specified and as directed.
S&F in repairs of switch socket combination 2-in-1 6 & 16 Amps flush type complete all as specified and as directed.
S&F in repairs of lamp holder bakelite insulated body with back plate suitable for batten fitting complete all as specified and as directed.
S&F in repairs of old unserviceable plug top 15/16 Amps, complete all as specified and as directed.
S&F in replacement of PRCD 16 AMP, 30 mA plug Top , complete all as specified and as directed.
S&F in repairs of fan regulator electronic, stepped type, Switch type, suitable for ceiling fan 1200/1400mm sweep complete all as specified and as directed.
S&F in repairs Tee cover of suitable size as per existing complete all as specified and as directed.
S&F in repairs of bell Ding dong type 230 volts single phase complete all as specified and as directed.
S&F in replacement of ceiling fan capacitor of 2.5 mfd complete all as specified and as directed.
S&F in replacement of ceiling fan capacitor of 3.15 mfd complete all as specified and as directed.
S&F in replacement MS fastner bolt 8 mm dia and upto 150 mm long for fixing Geyser/Exhaust Fan with nuts and washers complete all as specified and as directed.
S&F in replacement U clamp with rubber real for hanging ceiling fans of 1200/1400mm sweep as per sample complete all as specified and as directed.
S&F in replacement PVC connection with brass nipple 15 mm x 600 mm long with ISI marked suitable for hot and cold water of 25/50 ltrs capacity of geyser connection with 2 Nos brass/CP nuts as per sample complete all as specified and as directed.
S&F in repairsLED Batten T-5 fitting 20 watt LED White, indoor decorative pvc extruded T5 LED battern -integrated type complete including taking down of old unsv existing 36 Watt tube light fitting, complete all as specified and as directed.
S&F in repairs LED Integrated Batten T-5 10 watt - 2 FT White, indoor decorative pvc extruded T-5 LED battern -integrated type complete with including flexible wire including taking down of old unsv existing 18 Watt tube light fitting complete all as specified and directed by Engr-in-Charge.
S&F in repairs LED 10 watt white Bulk head in engineering plastic housing with clear prismatic including all accessories connecting up twisted flexible copper conductor cable of suitable size of 230 V, 50 Hz complete all as specified and directed by Engr-in-Charge.
S&F in repairs surface mounting round/square shaped LED downlighter with PDC pvc housing 12 Watt LED lamp type including taking down of old unsv existing CFL fitting any type from ceiling of stairs/common areas, complete all as specified and directed by Engr-in-Charge.
S&F in repairs of old unserviceable wall light fixture any type with Wall mounting fitting City-4, Decorative wall light fixture made up of Polycarbonate, of B-22 base complete all as specified and as directed.
S&F in repair of LED bulb 12 Watt B-22 Cap, AC 230V, 50 Hz suitable for Batten Holder/wall light fittings in replacement of old unsv lights any type complete all as specified and as directed.
S&F in replacement single pole and neutral metal clad sheet metal enclosures with 2 pin and earth plug and socket complete with one no MCB SP upto 20 Amps as per site requirment complete all as specified and as directed.
S&F in replacement single pole and neutral metal clad sheet metal enclosures with 2 pin and earth plug and socket complete with one no MCB SPN upto 32 Amps as per site requirment of existing type for AC's/Geyser complete all as specified and directed by Engr-in-Charge.
S&F in repairs for MCB SP 06 to 32 Amps 240 Volts, 10 KA, `B' curve, all as per site requirement and complete all as specified and as directed.
S&F in repairs for MCB SPN 32 to 40 Amps, 240 Volts, 10 KA, `B' curve, all as per site requirement and complete all as specified and as directed.
S&F in repairs for MCB SPN 63 Amps, 240 Volts, 10 KA, `B' curve, all as per site requirement and complete all as specified and as directed.
S&F in replacement for MCCB 4 pole 63 Amp 415 Volt, 'C' Series 10 KA' as per site requirement complete all as specified and as directed.
S&F in repairs Circuler Hylam/PVC Sheet upto 10 Cm dia of 3 mm thick (for using as Junction box Cover) including screws and cup washer complete all as specified and as directed.
S&F in repair of PVC casing caping of size 20 x 12mm of ISI Mark or as per manufacturer design with all accessories for surface wiring complete all as specified and as directed.
S&F in repairs of PVC insulated FRLS single core with stranded copper cable of size 1.5 Sqmm single core for any type of wiring as per site requirement and directed in Red/Blue/Yellow&Black&green colour complete all as specified and as directed.
S&F in repairs of PVC insulated FRLS single core with stranded copper cable of size 2.5 Sqmm single core for any type of wiring as per site requirement and directed in Red/Blue/Yellow&Black&green colour complete all as specified and as directed.
S&F in repairs of PVC insulated FRLS 3 core with stranded copper cable of size 2.5 Sqmm for any type of wiring as per site requirement and complete all as specified and as directed.
S&F in repairs of PVC insulated FRLS single core with stranded copper cable of size 4 Sqmm single core for any type of wiring as per site requirement and directed in Red/Blue/Yellow&Black&green colour complete all as specified and as directed.
S&F in replacement of heating element of 1.5 KW including rubber washers (ISI marked) etc as per site requirement complete all as specified and as directed.
S&F in replacement of thermostat 9/11" (ISI Marked) for 25/35/50 Litres capacity Geyser as per sample complete all as specified and as directed.
S&F in replacement of Sub Main wiring using single run PVC FR-LS grade Insulated unsheathed, multistrand copper conductor cable 2 runs of 10 Sqm for phase and neutral and 1 run of 10 Sqm for earth wire drawn through concealed PVC conduit wiring in wall not less than 32 mm dia with all fittings like tees, bends, junction/ terminal boxes etc as per site requirement and all as directed. Note:- (a) Two runs of main cable and one run of earth cable all-toghter shall be considered as one length. (b) New conduit of suitable size with connected fitting will be laid if there is a damage/blockage in existing conduit including making good to disturb surfaces with CM 1:3, same surface finished with the adjoining surface of disturbed area and the rates are inclusive of quoted rates.
S&F in replacement of Sub Main wiring using single run PVC FR-LS grade Insulated unsheathed, multistrand copper conductor cable 2 runs of 04 Sqm for phase and neutral and 1 run of 04 Sqm for earth wire drawn through concealed PVC conduit wiring in wall not less than 20 mm dia with all fittings like tees, bends, junction/ terminal boxes etc as per site requirement and all as directed. Note:- (a) Two runs of main cable and one run of earth cable all-toghter shall be considered as one length. (b) New conduit of suitable size with connected fitting will be laid if there is a damage/blockage in existing conduit including making good to disturb surfaces with CM 1:3, same surface finished with the adjoining surface of disturbed area and the rates are inclusive of quoted rates.
Note :- The contract sum shall be after deducting the amount of Credit shown in Sch of Credit of this Tender.
R.P Builders
M/S Parmod Johar
R. S. Associates
HANUMAN BUILDERS
Manisha Yadav
Joshi Constructions
R D ENTERPRISES
M/S GOPAL JEE SINGH
P R Constructions
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .