| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.2 LAdmitted-Finance | ₹5.2 L | L1 | Admitted-Finance |
| 2 | L2₹6.4 LAdmitted-Finance BASUDEBPUR BELKHALI HOWRAH PIN 711 322 | HOWRAH | HOWRAH | WEST BENGAL | 711322 | ₹6.4 L | L2 | Admitted-Finance |
| 3 | L3₹7.8 LAdmitted-Finance | ₹7.8 L | L3 | Admitted-Finance |
| Sl No | Description | Qty | Unit | Computer Gallery L2 | COSMIC RAY L3 | HINDUSTAN ENTERPRISES L1 |
|---|---|---|---|---|---|---|
| 1.00 | Supply, Installation,Testing & Commisioning of Micropresssor controlled Addressable Multisensor detector IP 42 ( VDS / UL /ERTL/ LPCB / FM approved ) with inbuilt optical smoke sensors and heat detector sensor with inbuilt short circuit fault isolator as per NFPA style 7 wiring complete with base (Note : Detectors without built-in fault isolator is also acceptable provided one independent short circuit fault isolator per detector is to be provided extra without extra cost) the detectors should have built in response indicator with LED indicator. The detector should have 360 degree optical view with single / multiple LED that blinks on actuation of detector. Reverse polarity or faulty zone wiring shall not damage the detectors.
(Approved Make : ESSER/Notifire/Bosch) | 120 | Nos | 3,000 ₹3.6 L | 3,285 ₹3.9 L | 1,360 ₹1.6 L |
| 2.00 | Supply, Installation,Testing & Commisioning of Micropresssor controlled Addressable Heat detector IP 42 ( VDS / UL /ERTL/ LPCB / FM approved ) with combination of fixed type & Rate of Rise of Temperature feature. Detector shall have maimum triggering temperature programmable from 60 deg. C to 80 deg. C., having high level of immunity to electromagnetic influances and show alarm signal limit temperature is reached. Detector shall have inbuilt short circuit fault isolator as per NFPA style 7 wiring complete with base (Note : Detectors without built-in fault isolator is also acceptable provided one independent short circuit fault isolator per detector is to be provided extra without extra cost) the detectors should have built in response indicator with LED indicator.
(Approved Make : ESSER/Notifire/Bosch) | 3 | Nos | 3,000 ₹9,000 | 3,300 ₹9,900 | 1,360 ₹4,080 |
| 3.00 | Supply, Installation,Testing & Commisioning of Addressable Manual Call Point ( VDS / UL /ERTL/ LPCB / FM approved ) with in built short circuit fault isolator as per NFPA style 7 wiring complete as required.
(Approved Make : ESSER/Notifire/Bosch) | 8 | Nos | 3,600 ₹28,800 | 5,055 ₹40,440 | 4,000 ₹32,000 |
| 4.00 | Supply, Installation, Testing & Commissioning of IP Addressable Loop Powered Hooter ( sound output of minimum 90 db ) cum strobe (strength of light 10 cd) complete with inbuilt short circuit fault isolator. Degree of protection IP65 ( VDS / UL /ERTL/ LPCB / FM approved) approved.
(Approved Make : ESSER/Notifire/Bosch) | 3 | Nos | 9,000 ₹27,000 | 9,145 ₹27,435 | 4,000 ₹12,000 |
| 5.00 | Supply, Installation, Testing & Commissioning of Addressable Monitor Modules & Transponder with necessary relay module ( VDS / UL /ERTL/ LPCB / FM approved ) for monitoring Flow switches / Fire exit doors / AHU/ Lift etc. with inbuilt short circuit fault isolator and minimum (04) four potential free contact with adjustable setting parameter likes of Input or output, complete in single or multiple housing with degree of protection IP 42 with flash LED indicator that conforms module is operational and integrated buzzer signaling maintenance alarm, complete as required.
(Approved Make : ESSER/Notifire/Bosch) | 3 | Nos | 4,000 ₹12,000 | 6,750 ₹20,250 | 4,000 ₹12,000 |
| 6.00 | Supplying, installation, testing and commissioning of LED type Response Indicator ( VDS / UL /ERTL/ LPCB / FM approved) having 2 Nos. red coloured LED lamps including connections etc.
(Approved Make : ESSER/Notifire/Bosch) | 20 | Nos | 100 ₹2,000 | 195 ₹3,900 | 216.4 ₹4,328 |
| 7.00 | Supply & Laying of 2 Core 1.5 sq.mm FRLS shielded copper Cable (For Loop) (Make. Finolex/ RR Kable/Polycab) through 20 mm dia PVC 'FR' type Rigid Conduit pipe with necessary arrangement as per G.S. (Make : Precision/ / Polycab) on the surface of the wall. | 1,200 | Mtr | 100 ₹1.2 L | 177 ₹2.1 L | 67 ₹80,400 |
| 8.00 | Re-Programmimg of EN54 standard, VDS Approved Microprocessor based 6 Loop Capable fire alarm control panel fully networkable with each loop capable of taking atleast 127 devices and each loop should be connected to a dedicated loop card.(Model -ESSER/Notifire/Bosch) as per direction of the E.I.C | 2 | Nos | 40,000 ₹80,000 | 36,000 ₹72,000 | 1,05,989 ₹2.1 L |
| 36.00N.B.: Within seven working days of receiving the work layout, the agency should prepare a layout drawing, get it duly signed by the EIC, and obtain approval from this office before starting the work. | ||||||
Updated dates
Tender Value
₹6.5 L
EMD Value
₹12,998
Closing Date
30 Mar 2026, 2:00 pmClosed
EE_KCED_PWD
office of EE_KCED_PWD_Khadyabhawan
Repairing, Rectification, Testing, Commissioning Cleaning of Fire Detection Systems of Khadyashree Bhawan
2026_PWDE_1015439_1
WBPWD/EE/57/IR/T/KCED/I of 2025-26 (2nd Call)
Open Tender
Electrical Work/ Equipment
30 days
Khadya Bhawan
Please refer Tender documents.
4 documents required · 4 mandatory
₹12,998
office of EE_KCED_PWD
18 May 2026
26 Feb 2026
2 Apr 2026
26 Feb 2026
30 Mar 2026
9 Mar 2026
6 Mar 2026
Supply, Installation,Testing & Commisioning of Micropresssor controlled Addressable Multisensor detector IP 42 ( VDS / UL /ERTL/ LPCB / FM approved ) with inbuilt optical smoke sensors and heat detector sensor with inbuilt short circuit fault isolator as per NFPA style 7 wiring complete with base (Note : Detectors without built-in fault isolator is also acceptable provided one independent short circuit fault isolator per detector is to be provided extra without extra cost) the detectors should have built in response indicator with LED indicator. The detector should have 360 degree optical view with single / multiple LED that blinks on actuation of detector. Reverse polarity or faulty zone wiring shall not damage the detectors. (Approved Make : ESSER/Notifire/Bosch)
Supply, Installation,Testing & Commisioning of Micropresssor controlled Addressable Heat detector IP 42 ( VDS / UL /ERTL/ LPCB / FM approved ) with combination of fixed type & Rate of Rise of Temperature feature. Detector shall have maimum triggering temperature programmable from 60 deg. C to 80 deg. C., having high level of immunity to electromagnetic influances and show alarm signal limit temperature is reached. Detector shall have inbuilt short circuit fault isolator as per NFPA style 7 wiring complete with base (Note : Detectors without built-in fault isolator is also acceptable provided one independent short circuit fault isolator per detector is to be provided extra without extra cost) the detectors should have built in response indicator with LED indicator. (Approved Make : ESSER/Notifire/Bosch)
Supply, Installation,Testing & Commisioning of Addressable Manual Call Point ( VDS / UL /ERTL/ LPCB / FM approved ) with in built short circuit fault isolator as per NFPA style 7 wiring complete as required. (Approved Make : ESSER/Notifire/Bosch)
Supply, Installation, Testing & Commissioning of IP Addressable Loop Powered Hooter ( sound output of minimum 90 db ) cum strobe (strength of light 10 cd) complete with inbuilt short circuit fault isolator. Degree of protection IP65 ( VDS / UL /ERTL/ LPCB / FM approved) approved. (Approved Make : ESSER/Notifire/Bosch)
Supply, Installation, Testing & Commissioning of Addressable Monitor Modules & Transponder with necessary relay module ( VDS / UL /ERTL/ LPCB / FM approved ) for monitoring Flow switches / Fire exit doors / AHU/ Lift etc. with inbuilt short circuit fault isolator and minimum (04) four potential free contact with adjustable setting parameter likes of Input or output, complete in single or multiple housing with degree of protection IP 42 with flash LED indicator that conforms module is operational and integrated buzzer signaling maintenance alarm, complete as required. (Approved Make : ESSER/Notifire/Bosch)
Supplying, installation, testing and commissioning of LED type Response Indicator ( VDS / UL /ERTL/ LPCB / FM approved) having 2 Nos. red coloured LED lamps including connections etc. (Approved Make : ESSER/Notifire/Bosch)
Supply & Laying of 2 Core 1.5 sq.mm FRLS shielded copper Cable (For Loop) (Make. Finolex/ RR Kable/Polycab) through 20 mm dia PVC 'FR' type Rigid Conduit pipe with necessary arrangement as per G.S. (Make : Precision/ / Polycab) on the surface of the wall.
Re-Programmimg of EN54 standard, VDS Approved Microprocessor based 6 Loop Capable fire alarm control panel fully networkable with each loop capable of taking atleast 127 devices and each loop should be connected to a dedicated loop card.(Model -ESSER/Notifire/Bosch) as per direction of the E.I.C
N.B.: Within seven working days of receiving the work layout, the agency should prepare a layout drawing, get it duly signed by the EIC, and obtain approval from this office before starting the work.
Please Enable Macros to View BoQ information
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.45 MB
2911.pdf
Tender Documents • 0.51 MB
BOQ_2494377.xls
BOQ • 0.35 MB
Download all tender documents and submit your bid