| 1 | L-1₹22.1 LAccepted-AOC | L-1 | Accepted-AOC L-1 | |
| 2 | L-2₹24.3 L+₹36,935.26 (1.54%)Rejected-Finance 3788 SHAH GANJ GB ROAD NEW DELHI 110006 | NORTH | DELHI | 110006 | L-2 | Rejected-Finance L-2 | |
| 3 | L-3₹25.3 L+₹1.3 L (5.57%)Rejected-Finance 205 PARSHAV VIHAR PLOT NO 50 IP EXTN PARPARGANJ DELHI 110092 | EAST | DELHI | 110092 | L-3 | Rejected-Finance L-3 | |
| 4 | L-4₹30.9 L+₹6.9 L (28.9%)Rejected-Finance WZ 576 577 NANGAL RAYA NEW DELHI 110046 | NEW DELHI | NEW DELHI | DELHI | 110046 | L-4 | Rejected-Finance L-4 | |
| 5 | L-5₹31.2 L+₹7.2 L (30.3%)Rejected-Finance H 13 GEETANJALI PARK WEST SAGARPUR NEW DELHI 110046 | NEW DELHI | DELHI | 110046 | L-5 | Rejected-Finance L-5 |
Tender Value
₹33 L
EMD Value
₹66,000
Closing Date
7 Jun 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) FARIDABAD
GE (AF) FARIDABAD
REPAIR/MAINTENANCE OF ACs AND REPAIR/REPLACEMENT OF SECURITY LIGHT/FLOOD LIGHTS AND OTHER ALLIED WORKS AT AF STN CHANDINAGAR IN AOR OF GE (AF) FARIDABAD
2023_MES_594435_1
GE (FBD)/AF-16/2023-2024
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
CHANDINAGAR
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (AF) FARIDABAD
₹66,000
Yes
2 Aug 2023
10 May 2023
9 Jun 2023
10 May 2023
7 Jun 2023
24 May 2023
10 May 2023 - 17 May 2023
Amount
M&L for servicing of Indoor unit & Out door unit of Split type AC of 1.5 tone capacity by taking out the same from existing location , cleaning , dusting, brushing, checking and rectify electrical conections, condenser , cooling coil and other components with cooling coil rinse solution without damage any part and reinstall at the same location and clean water with water pressure gun, greasing of fan , motor , blower including acid/detergent foam type wash etc complete all as specified and directed by Engineer-in-Charge.
All as per item No. 01 but split type AC of 2.0 ton complete all as specified and directed by Engineer-in-Charge.
M&L for servicing of Window type AC of 1.5 tone capacity by taking out the same from existing location , cleaning of condenser , cooling coil and other components with cooling coil rinse solution and clean water with water pressure gun, greasing of fan , motor , brushing cleaning with blower including acid/detergent foam type wash etc without damage any part and reinstall at the same location complete all as specified and directed by Engineer-in-Charge.
M&L for finding out the leakage the pressure test of the condenser of cooling coil of window type AC/split type AC of 1.5 ton and dismantling the same for repair the leakage point by brazing/ soldering including charging the gas R-22 ,R-32, R-410 and testing the AC to the complete all as specified and directed by Engineer-in-Charge.
All as per item No. 04 but split type AC of 2.0 ton complete all as specified and directed by Engineer-in-Charge.
M&L in repair for taking out unserviceable sealed unit (compressor) 1.5 ton capacity , single phase, 230 volt of models as existing and replacing the same with new sealed unit (compressor) including necessary modification of the foundation as required to suit the compressor, vacumacation , pressure , testing, leaking, rectification incl gas charging R-22,R-32 ,R-410 and testing complete to the complete all as specified and directed by Engineer-in-Charge.
All as per item S.No 06 above but 2 TR complete all as specified and directed by Engineer-in-Charge.
M&L for Split type AC outdoor unit (suitable for existing AC) complete only of capacity 1.5 TR complete all as specified and directed by Engineer-in-Charge. Make : Voltas, Blue star, LG , Hitachi,Lloyd( Havells) or its equivalent
M&L for Removing the split type AC 1.5 ton/ 2 ton capacity working on 230 V single phase /440 Volt 3 phase complete including indoor and out door unit including making good of all disturbed surfaces complete all as specified and directed by Engineer-in-Charge.
M&L for reinstall at any place ( with in the stn ) at height up to 5 mtr from floor level including replacement of refrigerant tubing upto 7.5 mtrs length and provision of drain pipe and pipe insulation, connecting with existing power socket and testing the unit for smooth functioning including making good of all disturbed surfaces complete all as specified and directed by Engineer-in-Charge.
M&L for Split AC Indoor unit (suitable for existing AC ) complete of capacity 1.5 TR complete all as specified and directed by Engineer-in-Charge. Make : Voltas, Blue star, LG , Hitachi,Lloyd( Havells) or its equivalent
M&L for stand ( wall mounted type & Floor mounted type ) of suitable for split type AC complete all as specified and directed by Engineer-in-Charge.
M& L for PVC drain pipe complete all as specified and directed by Engineer-in-Charge.
M&L for providing nitril rubber thermal insulation to copper tubing’s from Indoor to outdoor units with foam pipe insulation ( 1/2" ID X 1/2" thk) followed with clamps complete all as specified and directed by Engineer-in-Charge.
M&L for repair to PCB card of window / Split type AC for remote operation complete testing and installation and all electrical connections including replacement of defective electronic components / IC Circuits complete all as specified and directed by Engineer-in-Charge.
M&L for repair to PCB Card of inverter type split AC for remote operation complete testing and installation and all electrical connections including replacement of defective electronic components / IC Circuits complete all as specified and directed by Engineer-in-Charge.
S&F in replacmemt remote control unit (cordless) as per existing model for AC unit complete all as specified and directed by Engineer-in-Charge.
S & F Air filter suitable for 1.5 ton split type AC as required on site incl testing for satisfactry working condition complete all as specified and directed by Engineer-in-Charge.
All as per item No. 18 but split type AC of 2.0 ton complete all as specified and directed by Engineer-in-Charge.
S & F Thermostat suitable of 1.5 ton split AC as required on site complete all as specified and directed by Engr-in-Charge
All as per item No. 20 but split type AC of 2.0 ton complete all as specified and directed by Engineer-in-Charge.
S & F Single pole contactor for Split type AC 50/60 Hz 240 V complete all as specified and directed by Engineer-in-Charge.
S & F Axilary contactor single phase 220 Volts 10 Amps current capacity complete all as specified and directed by Engineer-in-Charge.
S & F Start Relay suitable of 1.5/2 ton split AC as required on site complete all as specified and directed by Engineer-in-Charge.
M&L for replace copper condenser coil assembly complete suitable for 1.5 ton split type AC suitable for existing incl testing for satisfactry working condition complete all as specified and directed by Engineer-in-Charge.
M&L for replace copper condenser coil assembly complete suitable for 2 ton split type AC suitable for existing incl testing for satisfactry working condition complete all as specified and directed by Engineer-in-Charge.
M&L for replace copper condenser coil assembly complete suitable for window type AC suitable for existing incl testing for satisfactry working condition complete all as specified and directed by Engineer-in-Charge.
M&L for replace evaporator coil assembly complete suitable for 1.5 ton Split type AC suitable for existing incl testing for satisfactry working condition complete all as specified and directed by Engineer-in-Charge.
M&L for replace evaporator coil assembly complete suitable for 2 ton Split type AC suitable for existing incl testing for satisfactry working condition complete all as specified and directed by Engineer-in-Charge.
M&L for replace evaporator coil assembly complete suitable for Window type AC suitable for existing incl testing for satisfactry working condition complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of copper tubing 5/8” outer dia suitable for 1.5/2 TR AC including nitril rubber thermal insulation capacity complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of copper tubing 3/8” outer dia suitable for 1.5/2 TR AC including nitril rubber thermal insulation capacity complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of copper tubing 1/4” outer dia suitable for 1.5/2 TR AC including nitril rubber thermal insulation capacity complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of condensing fan motor of capacity suitable for Split AC 1.5/2 Ton testing on load for the complete all as specified and directed by Engineer-in-Charge.
S&F in repairs running capacitor of capacity ‘45+5’ MFD, 240 volts, 50 Hz complete all as specified and directed by Engineer-in-Charge. Make Asian/EPCOS/PRIYA/ SARDA
All as per item No 35 above but capacity 36 MFD complete all as specified and directed by Engineer-in-Charge.
S&F in replacement blower suitable for existing Split AC complete all as specified and directed by Engineer-in-Charge.
S&F in repairs blower fan motor of capacity 1/30 HP, 3 speed, single phase (as per sample ) complete all as specified and directed by Engineer-in-Charge.
S&F in repair condenser fan motor of capacity 1/20 HP, single phase (as per sample) complete all as specified and directed by Engineer-in-Charge.
S&F in repair starting capacitor of capacity 60 MFD, 40 volt, 50 Hz complete all as specified and directed by Engineer-in-Charge. Make: Asian/EPCOS/Priya/Sarda
S&F in repairs starting capacitor of capacity 100-120 MFD , 440 volts, 50 Hz complete all as specified and directed by Engineer-in-Charge. Make : Tesla/ Asian/ Sarda
S&F in replacement of DC fan motor of split AC unit with supper enameled copper wire of suitable gauge wire and testing on load for the complete all as specified and directed by Engineer-in-Charge.
S&F Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 25 Amp complete all as specified and directed by Engineer-in-Charge.
M&L for Sub main wiring with two single core, 4 Sqmm, PVC insulated PVC unsheathed stranded FRLSH copper conductor cable including PVC concealed/ surface conduit of earth wire with 1 x 4 Sq mm copper cable fixed along with the sub main in PVC conduit and connecting to earth dolly complete all as specified and directed by Engineer-in-Charge. Make - Finolex/Havells/polycab
S&F in repairs of cable 3 core 4 sqmm FRLS PVC copper conductor complete all as specified and directed by Engineer-in-Charge. Make - Finolex/Havells/polycab
M&L for servicing of Refrigerator any size at existing location , cleaning , dusting, brushing, checking and rectify electrical conections, condenser , cooling coil and other components with cooling coil and other components with cooling coil rinse solution without damage any part at the same location complete all as specified and directed by Engineer-in-Charge. Note:- Components reqd to be replaced will be measured and paid separately
Supply only the following parts/components of refrigerator/Deep Freezer of 165/190/315/324/360/388/425 Ltr capacity complete all as specified and directed by Engineer-in-Charge. (a) Box type relay
All as per item No 47 but Thermostat with control knobcomplete all as specified and directed by Engineer-in-Charge.
All as per item No 47 but Drier complete all as specified and directed by Engineer-in-Charge.
All as per item No 47 but Condenser complete all as specified and directed by Engineer-in-Charge.
All as per item No 47 but Copper capillary Tube complete all as specified and directed by Engineer-in-Charge.
All as per item No 47 but Magnetic door gasket complete all as specified and directed by Engineer-in-Charge.
All as per item No 47 but Chiller tray complete all as specified and directed by Engineer-in-Charge.
All as per item No 47 but Vegetable tray PVC complete all as specified and directed by Engineer-in-Charge.
All as per item No 47 but Aluminium grill rack PVC Coated) complete all as specified and directed by Engineer-in-Charge.
All as per item No 47 but Pigmy lamp 15W with screwed/Bayonet Cap complete all as specified and directed by Engineer-in-Charge.
M & L for replacement of unserviceable sealed compressor with new hermetic sealed compressor of up to capacity 325 Ltr as existing make including charging of refrigerant gas and testing on full load complete all as specified and directed by Engineer-in-Charge.
All as per item No 57 above but capacity of refrigerator 360 Ltr complete all as specified and directed by Engineer-in-Charge.
M&L for servicing of Deep freezer of size 320/425 Ltr at existing location , cleaning , dusting, brushing, checking and rectify electrical conections, condenser , cooling coil and other components with cooling coil and other components with cooling coil rinse solution without damage any part at the same location complete all as specified and directed by Engineer-in-Charge.
M & L for replacement of unserviceable sealed compressor with new hermetic sealed compressor of capacity 425 Ltr as existing make including charging of refrigerant gas and testing on full load complete all as specified and directed by Engineer-in-Charge.
M & L for servicing of Water cooler of any capacity at existing location by cleaning of condenser, cooling coil, and other components with cooling coil Rinse solution & clean water, greasing of fan, motor including cleaning of storage tank with treated water after applying the potassium permanganate solution etc without damage any parts incl replacement of complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of starting relay as required at site for water coolers complete including connecting, testing complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of waste water tray as required at site made out of 20 gauge GI sheet complete with PVC drain pipe including painting with PVC drain pipe including painting with aluminum paint complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of brass float valves accessories 15mm size as required at site complete all as specified and directed by Engineer-in-Charge.
M&L for Disconnecting and taking down water cooler of any make and size for repairs including detection of leakage in the system rectifying the same, dehydration & recharging of gas testing the water cooler for smooth & satisfactory working complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of CP push cock ISI marked 15mm base complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of condenser fan motor single phase as required at site for water cooler with clamps, bolts, nuts & rubber bushes complete including connecting testing complete all as specified and directed by Engineer-in-Charge.
M&L for Replacement of wiring kit for water cooler of any make and capacity. complete all as specified and directed by Engineer-in-Charge. Make Hi-Tech/Aanutrol/Tecumseh/Sriram.
M & L for taking out unserviceable sealed unit (compressor) of water cooler 150/150 Ltrs capacity single phase 230 volt of as existing model and replacing the same with new sealed unit (Compressor ) including necessary modification of the foundation as required to suit the compressor, vacumisation presser testing, leakage rectification incl gas charging and testing complete all as specified and directed by Engineer-in-Charge.
All as per item No 69 above but compressor as existing model and replacing the same with new sealed unit (Compressor) for water cooler 80/40 Ltr capacity complete all as specified and directed by Engineer-in-Charge.
M & L for servicing of desert cooler of any capacity at existing location by cleaning of all components with Rinse solution & clean water, greasing of fan, motor including cleaning of water storage tank with treated water after applying the potassium permanganate solution etc without damage any parts incl replacement of small parts like PVC water distributer, flexible pipe, plugs etc as required on site complete all as specified and directed by Engineer-in-Charge.
M & L for scraping and removing old paint of desert cooler body (steel surfaces) and preparation of steel surfaces including necessary denting, cutting, welding etc for spray painting with approved smoke gray synthetic enameled paint (Ist quality) over a coat of Zinc chromate primer on outer surface and inner surface i.e. Water tank and body fan mounting blades shall be painted with a coat of anticorrosive black paint over a coat of Zinc chromate primer complete for desert cooler of any size and capacity complete all as specified and directed by the Engr- in - Charge.
S & F in replacement Desert cooler Pump as per existing capacity complete all as specified and directed by Engineer-in-Charge.
M & L for replacement of cooling fan motor supporting legs and PVC fan blade of 450 mm sweep for desert cooler complete all as specified and directed by Engineer-in-Charge. Make- Khaitan/ Snow cool/Crompton/ GEC
M & L for rewinding of desert cooler motor of any make with supper enameled copper wire (Thermal class E) of appropriate size including replacement of gun metal bushed and steel shaft complete all as specified and directed by Engineer-in-Charge.
M & L in replacement of 01 Nos front grill and 3 side loovers suitable for disert cooler duly spray painted with approved paint over a coat of red oxide primer and internal surface of body cooler pump and motor shall be painted with two coat of bituminous paint over a coat of red oxide primer as required on site complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of Desert cooler motor copper wound complete all as specified and directed by Engineer-in-Charge.
M & L for replacement of desert cooler body 660x660x900mm with front grill and three side louver fabricated out of 22 gauge mild steel plan black sheet and bottom water tank (sump) of size 660x660x200mm deep fabricated out of 20 gauge milled steel plan black sheet including taking out and reinstallation complete with standard fitting such as PVC pipe for water electric controls and switch, fan speed regulator rewiring of fan motor and water lifting pump including fixing and connecting existing cooler fan and electric pump with 3 core PVC insulated & PVC sheathed cables (min3 mtr in length). External surface shall be spray painted with approved paint over a coat of red oxide primer and internal surface of body cooler pump and motor shall be painted with two coat of bituminous paint over a coat of red oxide primer complete all as specified and directed by Engineer-in-Charge.
M & L for replacement of running cap 4.0 MFD 440 volt complete all as specified and directed by Engineer-in-Charge. Make- Jaivic/Sarda/Epcos.
M & L for replacement of wood wool pad 25mm thick duly winded with the nylon mesh of standard size for 4000 cum/hr capacity desert coolers complete all as specified and directed by Engineer-in-Charge.
S&F in replacement plug top 5 Amps complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of rotary switch as requirement at site complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of PVC water distributer flexible pipe with TEE and all accessories in desert cooler complete all as specified and directed as requirement at site complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of piano type 05 amp switch 230 volt , AC complete all as specified and directed by Engineer-in-Charge.
S&F cable copper conductor PVC insulated FRLS 2 core 1.5 Sqmm complete all as specified and directed by Engineer-in-Charge.
M&L for servicing, repair of Voltage stabilizer of capacity 4 / 5 KVA cleaning , dusting, brushing, checking and rectify electrical conections, and other components complete all as specified and directed by Engineer-in-Charge.
S&F in repairs time delay relay suitable for 4/5 KVA voltage stabilizer complete all as specified and directed by Engineer-in-Charge.
S&F in repirs diode suitable for voltage stabilizer of capacity 4/ 5 KVA complete all as specified and directed by Engineer-in-Charge.
S&F in repairs condenser suitable for voltage stabilizer of capacity 4/5 KVA complete all as specified and directed by Engineer-in-Charge.
S&F electronic circuit board with relay suitable for 4/5 KVA voltage stabilizer of any make and testing complete all as specified and directed by Engineer-in-Charge.
M&L in repair transformer suitable for voltage stablizer 4/5 KVA as required on site complete all as specified and directed by Engineer-in-Charge.
S&F in repairs and replacement of voltage stabilizer of capacity 5 KVA input variation between 170 volts to 250 volts with output voltage stabilized at 230 with accuracy of +-2.5% and capacity 5 KVA complete all as specified and directed by Engineer-in-Charge. Make : V Guard , Havells , LG or its equivalent
M&L for Exhaust fan motor for 300 mm sweep ( as per suitable for exixting) complete all as specified and directed by Engineer-in-Charge.
S&F wall mounting fan motor for 400 mm sweep complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of Exhaust fan 10"/12" sweep complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of PVC Exhaust fan 300MM sweep complete all as specified and directed by Engineer-in-Charge.
M&L for servicing,Taking down ceiling fan 56"/48" sweep removing cleaning of dust, properly cleaning greasing of bearing including replacing and painting connecting up complete all as specified and directed by Engineer-in-Charge.
Supply and fixing capacitor, capacity 2.5 mfd in replacement complete all as specified and directed by Engineer-in-Charge.
Supply and fixing capacitor, capacity 3.15 mfd in replacement complete all as specified and directed by Engineer-in-Charge.
M&L for rewinding of burnt ceiling fan motor 1200/1400 mm sweep with super enamelled copper winding wire of suitable guage as per details of any make /model complete all as specified and directed by Engineer-in-Charge.
Supply and replacement of ball bearing of ceiling fan of any size complete all as specified and directed by Engineer-in-Charge.
Supply and fixing and connecting flexible copper twisted twin core of size 23/00076. complete all as specified and directed by Engineer-in-Charge. Make Plaza/Kalinga/Polycab
Supply and replacement of gun metal bush of any type/make/size complete all as specified and directed by Engineer-in-Charge.
supply and replacement of rubber real complete all as specified and directed by Engineer-in-Charge.
Supply and replacement of U Clamp complete with nuts, bolts, pins. Heavy duty complete all as specified and directed by Engineer-in-Charge.
Supply and fixing nuts,bolts, washers and spilt pins for ceiling fan complete all as specified and directed by Engineer-in-Charge.
S&F stepped type electronic fan regulator flush type 230 Volts , AC complete all as specified and directed by Engineer-in-Charge.
S& F AC plug to of 20 Amp, 3 Pin suitable for AC Box (sheet metal enclosure with a two pin and earth plug and socket ) 230 Volts , AC complete all as specified and directed by Engineer-in-Charge.
S& F AC socket of 20 Amp, 3 Pin suitable for AC Box (sheet metal enclosure with a two pin and earth plug and socket ) 230 Volts , AC complete all as specified and directed by Engineer-in-Charge.
S&F in replacement LED Street Light Luminaries 45 watt fitting aesthetically designed for road lighting, having secondary optics with uniform distribution of light. Pressure die cast aluminum housing powder coated in grey and toughened glass, IP 66 protection, class I with operating voltage range 120 to 270 V including LED driver and including taking down complete all as specified and directed by Engineer-in-Charge. Make : Havells , Bajaj , Crompton , Polycab
S&F in replacement LED Street Light Luminaries 60 watt fitting aesthetically designed for road lighting, having secondary optics with uniform distribution of light. Pressure die cast aluminum housing powder coated in grey and toughened glass, IP 66 protection, class I with operating voltage range 120 to 270 V including LED driver and including taking down ccomplete all as specified and directed by Engineer-in-Charge. Make : Havells , Bajaj , Crompton , Polycab
S&F in replacement LED Street Light Luminaries 70 watt fitting aesthetically designed for road lighting, having secondary optics with uniform distribution of light. Pressure die cast aluminum housing powder coated in grey and toughened glass, IP 66 protection, class I with operating voltage range 120 to 270 V including LED driver and including taking down complete all as specified and directed by Engineer-in-Charge. Make : Havells , Bajaj , Crompton , Polycab
S&F in replacement LED Street Light Luminaries 90 watt fitting aesthetically designed for road lighting, having secondary optics with uniform distribution of light. Pressure die cast aluminum housing powder coated in grey and toughened glass, IP 66 protection, class I with operating voltage range 120 to 270 V including LED driver and including taking down complete all as specified and directed by Engineer-in-Charge. Make : Havells , Bajaj , Crompton , Polycab
S&F in replacement of outdoor type LED flood light 150/170 watt fitting aesthetically designed for road lighting, having secondary optics with uniform distribution of light. Pressure die cast aluminum housing powder coated in grey and toughened glass, IP 66 protection, class I with seperate driver and operating voltage range 120 to 270 V including suitable fixing arrangment and including taking down complete all as specified and directed by Engineer-in-Charge. Make : Havells , Bajaj , Crompton , Polycab
S&F in replacement of outdoor type LED flood light 200/210 watt fitting aesthetically designed for road lighting, having secondary optics with uniform distribution of light. Pressure die cast aluminum housing powder coated in grey and toughened glass, IP 66 protection, class I with seperate driver and operating voltage range 120 to 270 V including suitable fixing arrangment and including taking down complete all as specified and directed by Engineer-in-Charge. Make : Havells , Bajaj , Crompton , Polycab
Supply and Fixing including repair/replacement of LED driver 230 volt single phase of 45/50 watt, driver life >= 25000 Hrs efficiency - 85%, with out put short circuit protection complete all as specified and directed by Engineer-in-Charge. Make – halonix /Havell’s/bajaj/polycab ,Crompton
Supply and Fixing including repair/replacement of LED driver 230 volt single phase of 60 watt, driver life >= 25000 Hrs efficiency - 85%, with out put short circuit protection complete all as specified and directed by Engineer-in-Charge.Make – halonix /Havell’s/bajaj/polycab ,Crompton
Supply and Fixing including repair/replacement of LED driver 230 volt single phase of 70-90 watt, driver life >= 25000 Hrs efficiency - 85%, with out put short circuit protection complete all as specified and directed by Engineer-in-Charge. Make – halonix /Havell’s/bajaj/polycab ,Crompton
Supply and Fixing including repair/replacement of LED flood light driver 230 volt single phase of 150/200 watt, driver life >= 25000 Hrs efficiency - 85%, with out put short circuit protection complete all as specified and directed by Engineer-in-Charge. Make – halonix /Havell’s/bajaj/polycab ,Crompton
S & F in replacement of hot pressed moulded SMC boxes with hinged door fixing of size 325x220x150 mm with MS clamp 25 x 3mm made to shape with necessry nuts bolts clamps and washers complete comprising of Aluminium bus bar 63 Amps capacity of suitable size -04 nos mounted over Porcelain insulator with nuts & bolts washers incl MCB SP 6 amps and making incoming and outging connections by taking out loops of cable of any size incl necesary excavations and other civil works complete all as specified and directed by Engineer-in Charge. Make :- Sintex /Universal/ SMS
S & F in replacement of street light bracket made out of GI pipe note less than 25mm bore suitable to fit with LED street light approx length not less than 120cm bent to shape including new clamps made of MS flat of size 30x4 mm thick including cutting, welding drilling holes, nut, bolts washers etc including two coat of aluminium paint over one coat of red oxide primer on MS work complete all as specified and directed by Engineer-in-Charge.
M & L for replacement of cable PVC insulated unarmored for connection 2.5 sqmm x 3 core Copper conductor from junction box to street light fittings on poles including PVC flexible pipes and lugs complete all as specified and directed by Engineer-in-Charge. Make : havells , Polycab,RR kable , Finolex
Material & Labour for surface cleaning of steel tubular poles LT 9 mtrs long including removing rusted particles and painting with two coats of synthetic enamel aluminium paint over a coat of red oxide including cross arms, bracing, supports, clamps, eye hooks, security light bracket, clamp etc and providing black & white strips alternatively 30cm each from coping upto 1.5 mtr height starting with black strip using synthetic enamel paints incl repairing and painting on coping with cement base white paint complete all as specified and directed by Engineer-in-Charge. Note: (i) The quoted rate shall includes marking of numbers on each LT pole as per direction of Engr-in-Charge. (ii) The quoted rates shall including the reapiring of coping with cement / PCC.
Material & Labour for overhauling , servicing , repairing of 3 phase induction motor 1.1 0 KW , 415 volt , 920 RPM, 50 Hz, single phase of high mast light incl replacemnt of unsv parts and makie full functioning of motor complete all as specified and directed by Engineer-in-Charge.
Material & Labour for overhauling , servicing , repairing of gear box of high mast light incl replacemnt of unsv parts and makie full functioning of gear box complete all as specified and directed by Engineer-in-Charge.
M & L for Servicing of OLD/ UNSV -SOLAR street light fitting including servicing and Cleaning of solar panel , Low maintenance tubular battery by filling of Distilled water and first charging including replacement of damaged battery terminals, securing of all electrical wire circuit and connections, reparing of damaged foundation complete system if required or complete all as specified and directed by Engineer-in-Charge. Note:- 1. All type of T & P, Distilled water, control cable upto battery terminal, PCC, ladder & tripod etc required at site will be arranged by the contractor and rates for the same will be deemed to be included in the quoted rate. (Spares required to make functional of solar light shall be measured and paid seperately under relevent items )
Spares of Solar security light complete all as specified and directed by Engineer-in-Charge. (a) Replacement of Solar PV Module 74W( As per existing)
All as per item No 128 above but Replacement of White LED based light source 12W( As per existing ) complete all as specified and directed by Engineer-in-Charge.
All as per item No 128 above but Replacement of Driver of solar street Lights( As per existing ) complete all as specified and directed by Engineer-in-Charge.
All as per item No 128 above but Replacement of Battery rating of 12V & 100 AH( As per existing ) complete all as specified and directed by Engineer-in-Charge.
Supply & fix battery compartment box made up of MS sheet 2mm thick size suitable for battery with MS cover, locking arrangements & fixing accessories with inside weather proof coated & out side Aluminium paint incl writing pole number in black colour paint etc complete all as specified and directed by Engineer-in-Charge.
S & F in replacement of Integrated all in one Solar Street light (Inbuit Solar PV module and Lithium battery ) 24 watt, secondary optics, LED driver efficiency>92%, battery type LiFePO-04, IP66, colour temperature 6000K-6500K , 140 Lumens per watt Auto On/Off, overcharging protection incl taking down old unser and complete fixing and connection complete all as specified and directed by Engineer-in-Charge.
Supply & fix Electronic timer 240V AC, adjustment time 6-120Sec complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of Socket type aluminum lugs of 400 Sqmm by disconneting the cables removing the old unserviceble ones and replacing complete all as specified and directed by Engineer-in-Charge. Make : Dowell’s
All as per item No. 135 but Socket type aluminum lugs 240 Sqmm
All as per item No. 135 but Socket type aluminum lugs 120Sqmm
All as per item No. 135 but Socket type aluminum lugs 95 Sqmm
All as per item No. 135 but Socket type aluminum lugs 70 Sqmm
All as per item No. 135 but Socket type aluminum lugs 50 Sqmm
All as per item No. 135 but Socket type aluminum lugs 35 Sqmm
All as per item No. 135 but Socket type aluminum lugs 25 Sqmm
All as per item No. 135 but Socket type aluminum lugs 16 Sqmm
Material & labour for earthing in repair complete with galvanized steel earth electrode plate of size 60x60x6mm thick surrounded by char coal and salt buried directly in ground vertically in pit of depth not less then 2.25 mtr below ground level with top edge of the earth plate at depth of not less then 1.5 mtr below ground level surrounded from all sides by char coal dust and common salt in alternate layers of 15 cm depth and earth plate electrode connected to GI earth lead strip of size 25X4.0 mm at two points by means of GI nuts bolts, check nuts and washers and connected to earthling test point drawn through 40 mm dia GI pipe for protection pipe incl PCC earth pit (1:3:6) type C-2 with CI frame and RCC cover all as shown in electrical Plate No 3 on SSR Part-I including testing and dismantling ,taking down old unser earthing complete all as specified and directed by Engineer-in-Charge. Note: (i) Rate of Earth work, Earthing electrode, all connections, nut-bolts, washers, complete labour, testing, Earth lead upto 7.5 mtr, char coal dust, common salt, porcelain insulator,PCC earth Pit, CI frame ,RCC cover, funnel with wire mesh are incl in quoted rate and watering pipe, earth lead protection pipe, test poit, and earth lead exceeding 7.5 mtr are measured and paid separately.
M&L for Providing,PCC 1:3:6 type C-1 using 20 mm graded stone aggreat,for damaged earth pit chamber with fair finish internal surface of concrete chamber of earth and mass filling and coping of pole and strut, stay around the pole etc complete all as specified and directed by Engineer-in-Charge.
M&L for PCC 1:4:8 type D-2 using 40mm graded aggregate, mechanically crushed stone in wall, reataining wall any thickness, size, shape,base of pole in pole pit and foundation etc complete all as specified and directed by Engineer-in-Charge.
Supply ,and errection in true vertical position steel tubular swaged pole type 410 co SP-31 in repair, 09 mtr long complete with cast iron base plate and final tape plug, bolts, nuts, washers and screws incl painting with synthetic anamelled aluminium paint two coat over one coat of red oxide primer after errection and providing black and white strips with synthetic enamel point 30 cm each alternate upto 1.5 mtr above the coping of pole starting with black strip complete and marking pole number on pole complete all as specified and directed by Engineer-in-Charge. Note: (i) Earth work and PCC shall be measured and paid separately. (ii) Description as per direction of Engr-in-Charge will be printed on each pole without any extra cost.
Supply and fixing stay assembly complete with all accessories in repair, such as stay plate 230X230X6 mm3, stay rod 215 cm long and 16 mm dia with nuts incl GI bow turn buckle, GI stay wire, Loop type insulator etc. all as per electrical plate No 1 orr SSR part 1 and incl taking down old unsv complete all as specified and directed by Engineer-in-Charge. Note: Only excavation and PCC work will be measured and paid separately.
M&L in replacement for pin type insulator porcelain vitreous white or brown 1100 volts grade 100 mm height and 65 mm dia with Galvanised mild steel spindle two GI washer and one GI nut complete all as specified and as directed by Engineer-in-Charge.
Material & labour in repair for aluminium conductor steel reinforced (ACSR) including fixing, stretching on poles and proper noseling with binding wire with insulator, jumpring of any size as required at site incl dismantling and taking down old unser complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of 80 mm thick PCC pit cover 320 mm x 320 mm of PCC 1:2:4 TYPE B-1 using 20 MM graded stone aggregate including necesssary form work and handle for removing the cover from pit with fair finish complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buired in ground or drawn in conduit / pipe or fixed to pole or any other indicated situation for loop earthing etc as required 4 mm dia galvanised iron or steel wire complete all as specified and directed by Engineer-in-Charge.
Excavation in trenches in soft/loose soil not exceeding 1.5 Mtr wide and not exceeding 1.5 Mtr depth for laying of cables/poles or foundation etc and getting out all as specified and directed by Engineer-In-Charge.
Returning, filling, including spreading levelling and well ramming in layers not exceeding 25cm apart complete all as specified and directed by Engineer-in-Charge.
Removing of surplus excavated soil to a distance not exceeding 50 Mtr from starting point and depositing where directed at a level not exceeding 1.5 Mtr above the starting point complete all as specified and directed by Engineer-in-Charge.
M&L for sand cushoning with a layer of sand 80mm thick before laying of cable and 150mm thick after laying of cable to trenches complete all as specified and directed by Engineer-in-Charge.
M&L for sub class `B` bricks for cable protection complete all as specified and directed by Engineer-in-Charge.
Taking down UNSV LT Under Ground cable of any size complete all as specified and directed by Engineer-in-Charge.
Supply and laying, connecting and testing XLPE underground cable insulated, and overall sheathed with aluminium conductor heavy duty 1100 volts grade 16 sqmm 4 core laid in trenches/ on poles/ road crossing or passing through existing/new pipe under road crossing, clamping on wall etc complete all as specified and directed by Engineer-in-Charge. Note: (i) Cost of laying electrical cable through new/existing pipe under road, buildings, railway tracks, highways and Aluminium thimbles/lugs are incl in the quoted rates. (ii) All equipments , machinery or tools if required for laying electrical cable through new/existing pipes are provided by the contractor without any extra cost.Make : Havells, Polycab, KEI , CCI
All as per Item No 159 here in before but for 3.5 core 25 Sqmm complete all as specified and directed by Engineer-in-Charge.
M/S Anand Enterprises
Saini Enterprises
Shiv Enterprises
J.P. Enterprises
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .