Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.8 LAccepted-AOC 16 BAITHAKKHANA ROAD 16 BAITHAKKHANA ROAD SEALDAH BAITHAKKHANA ROAD SEALDAH BAITHAKKHANA ROAD SEALDAH KOLKATA | L1 | Accepted-AOC Accepted | |
| 2 | L2₹32.8 L+₹6.9 L (26.4%)Rejected-Finance COLLEGE ROAD CHABUA PO CHABUA DIST DIBRUGARH ASSAM 786184 | DIBRUGARH | ASSAM | 786184 | L2 | Rejected-Finance Higher than L1 Bidder | |
| 3 | L3₹34.0 L+₹8.0 L (31.0%)Rejected-Finance 1389 RADHETENAMENT SOCIETY SARDAR ROAD SURENDRANAGAR SURENDRA NAGAR GUJARAT 363001 | SURENDRANAGAR | GUJARAT | 363001 | L3 | Rejected-Finance Higher than L1 Bidder | |
| 4 | L4₹37.3 L+₹11.3 L (43.6%)Rejected-Finance | L4 | Rejected-Finance Higher than L1 Bidder | |
| 5 | L5₹37.6 L+₹11.6 L (44.8%)Rejected-Finance P O WEST SRIPURIA DIST TINSUKIA ASSAM PIN 786 145 | TINSUKIA | ASSAM | 786145 | L5 | Rejected-Finance Higher than L1 Bidder |
Tender Value
₹25.2 L
EMD Value
₹50,400
Closing Date
6 Oct 2020, 6:00 pmClosed
MAJ JYOTI PRAKASH SAHOO
GE 872 EWS, C/O 99 APO
REPAIRS MAINT TO INTERNAL ELECTRIFICATION REPAIRS MAINT SERVICING TO VARIOUS TYPES OF FANS AND GEYSER AND REPAIRS MAINT SERVICING TO COOLING APPLIENCES AT LIKABALI MIL STN UNDER GE 872 EWS
2020_MES_373695_1
8826/T-26/E8
Open Tender
Miscellaneous Works
Item Rate
213 days
LIKABALI
ALL AS PER NIT AND TENDER DOCUMENTS
7 documents required · 7 mandatory
₹500
GE 872 EWS
₹50,400
Yes
20 Nov 2020
1 Sept 2020
8 Oct 2020
1 Sept 2020
6 Oct 2020
14 Sept 2020
1 Sept 2020 - 7 Sept 2020
Amount
REPAIRS/MAINT TO INTERNAL ELECTRIFICATIONS
M&L Taking down carefully Copper/Aluminium Point Wiring (Light, Fan, Socket or Power) complete from in any position including Fixture and Fittings such as Switches, Ceiling Roses, Pendants, Regulators, Sockets, Light Fittings, etc, Making Good disturbed surfaces of Walls/ Ceillings, etc. in Cement Mortar 1:3 including providing Surface Treatment (Colour Washing/ Distempering/ Painting) wherever required to match the Existing Finishes, complete all as specified and as directed.
M&L Taking down/out unserviceable Sub-main Wiring from Batten/ Conduit/ PVC Casing Capping of any description, Making Good disturbed Portion/ Surfaces of Walls/ Floor/ Ceiling, etc. by using Cement Mortar 1:3 including providing Surface Treatment to match the Existing Treatment/ Finishes on Ground, complete all as specified and as directed.
M&L Point Wiring with 1.5 Sqmm (nominal area) 1100 Volt grade PVC insulated unsheathed FRLS multi-stranded single core Copper Conductor Cable with 1.5 Sqmm (nominal area) 1100 Volt grade PVC insulated unsheathed FRLS multi-stranded Single Core Copper Conductor Cable (Green Colour) as Earth Continuity Wire, drawn in and including PVC Casing Capping (ISI Marked) of suitable size (approx 20/25/32/40mm width) along with all Fitting/ Fixtures as Tee, Bend, Elbow, Socket, Saddles, etc. complete with PVC Board of suitable size for accommodating Switches, Sockets, Regulators, etc. Earth Continuity Wire connected to Common Earth dolly for ONE LIGHT/FAN POINT controlled by One 1-way Switch 6 Amp, complete all as specified and as directed.
M&L Point Wiring with 1.5 Sqmm (nominal area) 1100 Volt grade PVC insulated unsheathed FRLS multi-stranded single core Copper Conductor Cable with 1.5 Sqmm (nominal area) 1100 Volt grade PVC insulated unsheathed FRLS multi-stranded Single Core Copper Conductor Cable (Green Colour) as Earth Continuity Wire, drawn in and including PVC Casing Capping (ISI Marked) of suitable size (approx 20/25/32/40mm width) along with all Fitting/ Fixtures as Tee, Bend, Elbow, Socket, Saddles, etc. complete with PVC Board of suitable size for accommodating Switches, Sockets, Regulators, etc. Earth Continuity Wire connected to Common Earth dolly for ONE BELL/ BUZZER POINT controlled by One 1-way Switch 6 Amp, complete all as specified and as directed.
M&L Point Wiring with 1.5 Sqmm (nominal area) 1100 Volt grade PVC insulated unsheathed FRLS multi-stranded single core Copper Conductor Cable with 1.5 Sqmm (nominal area) 1100 Volt grade PVC insulated unsheathed FRLS multi-stranded Single Core Copper Conductor Cable (Green Colour) as Earth Continuity Wire, drawn in and including PVC Casing Capping (ISI Marked) of suitable size (approx 20/25/32/40mm width) along with all Fitting/ Fixtures as Tee, Bend, Elbow, Socket, Saddles, etc. complete with PVC Board of suitable size for accommodating Switches, Sockets, Regulators, etc. Earth Continuity Wire connected to Common Earth dolly for ONE 3/5 PIN SOCKET 6 AMP POINT on INDEPENDENT BOARD, complete all as specified and as directed.
M&L Point Wiring with 1.5 Sqmm (nominal area) 1100 Volt grade PVC insulated unsheathed FRLS multi-stranded single core Copper Conductor Cable with 1.5 Sqmm (nominal area) 1100 Volt grade PVC insulated unsheathed FRLS multi-stranded Single Core Copper Conductor Cable (Green Colour) as Earth Continuity Wire for ONE 3/5 PIN SOCKET 6 AMP POINT on SAME BOARD, complete all as specified and as directed.
M&L Point Wiring with 2.5 Sqmm (nominal area) 1100 Volt grade PVC insulated unsheathed FRLS multi-stranded single core Copper Conductor Cable with 2.5 Sqmm (nominal area) 1100 Volt grade PVC insulated unsheathed FRLS multi-stranded Single Core Copper Conductor Cable (Green Colour) as Earth Continuity Wire, drawn in and including PVC Casing Capping (ISI Marked) of suitable size (approx 25/32/40mm width) along with all Fitting/ Fixtures as Tee, Bend, Elbow, Socket, Saddles, etc. complete with PVC Board of suitable size for accommodating Switches, Sockets, Regulators, etc. Earth Continuity Wire connected to Common Earth dolly for ONE 3/5 PIN SOCKET OUTLET 6/16 AMP POINT on INDEPENDENT BOARD, complete all as specified and all as directed.
M&L Sub-main Wiring with 2-Runs of 2.5 Sqmm (nominal area) 1100 Volt PVC insulated unsheathed FRLS multi-stranded Single Core Copper Conductor Cable and 1-Run of 1.5 Sqmm (nominal area) 1100 Volt PVC insulated unsheathed FRLS multi-stranded Single Core Copper Conductor Cable (Green Colour) as Earth Continuty Conductor drawn through and including PVC Casing Capping (ISI Marked) of suitable size (approx 25/32mm width) along with all Fitting/ Fixtures as Tee, Bend, Elbow, Socket, Saddles, etc. (White/ Ivory/ Off White in Colour) and Making Good Disturbed Surfaces of Walls/ Roofs/ Floors, etc. so as to match with the Existing Finishes, complete all as specified and as directed. NOTE :- (a) Cost of 3-Runs of Cables & 1-Run of PVC Casing Capping shall deem to be included in the Quoted Unit Rate and the same also Mesured as ONE UNIT (b) Sub-main Wiring will be measured existing PVC Conduit only. Wire required for looping, etc. as ordered will deem to be included in the Quoted Unit Rate.
M&L Sub-main Wiring with 2-Runs of 4.0 Sqmm (nominal area) 1100 Volt PVC insulated unsheathed FRLS multi-stranded Single Core Copper Conductor Cable and 1-Run of 2.5 Sqmm (nominal area) 1100 Volt PVC insulated unsheathed FRLS multi-stranded Single Core Copper Conductor Cable (Green Colour) as Earth Continuty Conductor drawn through and including PVC Casing Capping (ISI Marked) of suitable size (approx 25/32mm width) along with all Fitting/ Fixtures as Tee, Bend, Elbow, Socket, Saddles, etc. (White/ Ivory/ Off White in Colour) and Making Good Disturbed Surfaces of Walls/ Roofs/ Floors, etc. so as to match with the Existing Finishes, complete all as specified and as directed. NOTE :- (a) Cost of 3-Runs of Cables & 1-Run of PVC Casing Capping shall deem to be included in the Quoted Unit Rate and the same also Mesured as ONE UNIT (b) Sub-main Wiring will be measured existing PVC Conduit only. Wire required for looping, etc. as ordered will deem to be included in the Quoted Unit Rate.
S&F PVC Casing Capping (ISI Marked) of size 25mm including all Fitting/ Fixtures such as Tee, Bend, Elbow, Socket, Saddles, etc. including Taking down/ out unserviceable PVC Casing Capping, complete all as specified and as directed.
S&F PVC Casing Capping (ISI Marked) of size 32mm including all Fitting/ Fixtures such as Tee, Bend, Elbow, Socket, Saddles, etc. including Taking down/ out unserviceable PVC Casing Capping, complete all as specified and as directed.
S&F PVC Rectangular Block of size 100x100x50mm deep with 3.0mm thick Plastic Laminated Sheet Cover for mounting Swiches, Sockets, Fan Regulators, etc. including Taking down/ out unserviceable PVC Block, complete all as specified and as directed.
S&F PVC Rectangular Block of size 175x100x50mm deep with 3.0mm thick Plastic Laminated Sheet Cover for mounting Swiches, Sockets, Fan Regulators, etc. including Taking down/ out unserviceable PVC Block, complete all as specified and as directed.
S&F PVC Rectangular Block of size 200x150x50mm deep with 3.0mm thick Plastic Laminated Sheet Cover for mounting Swiches, Sockets, Fan Regulators, etc. including Taking down/ out unserviceable PVC Block, complete all as specified and as directed.
S&F Switch Piano 6 Amp, Flush type, Single Pole, 1-way, 230 Volt AC and connecting up, complete all as specified and as directed.
S&F Switch Piano 6 Amp, Flush type, Single Pole, 1-way, 230 Volt AC and connecting up including Taking down/ out unserviceable Switch Piano, complete all as specified and as directed.
S&F Bell Push, 6 Amp, Single Pole, Flush type, 230 Volt AC for operating Bell/ Buzzer and connecting up, complete all as specified and as directed.
S&F Socket Outlet 3 Pin, 6 Amp, 2-in-1, Flush type, 230 Volt AC and connecting up including Taking down/ out unserviceable Socket Outlet, complete all as specified and as directed.
S&F Switch Socket Combination 3 Pin, 6 Amp, 2-in-1, Multi-Plug, Flush type, 230 Volt AC and connecting up including Taking down/ out unserviceable Switch Socket Combination, complete all as specified and as directed.
S&F Switch Socket Combination 3 Pin, 6/16 Amp, 2-in-1, Flush type, Universal, 230 Volt AC and connecting up, complete all as specified and as directed.
S&F Switch Socket Combination 3 Pin, 6/16 Amp, 2-in-1, Multi-Plug, Flush type, 230 Volt AC and connecting up including Taking down/ out unserviceable Switch Socket Combination, complete all as specified and as directed.
S&F Lamp Holder PVC/ Polycarbonate type with Back Plate suitable for Batten Fitting and connecting up, complete all as specified and as directed.
S&F Angular Lamp Holder PVC/ Polycarbonate type with Back Plate suitable for Batten Fitting and connecting up including Taking down/ out unserviceable Lamp Holder, complete all as specified and as directed.
S&F Ceiling Rose Surface type, Bakelite 65x50mm, 3 Terminal suitable for 230 Volt AC, 6 Amp and connecting up, complete all as specified and as directed.
S&F Ceiling Fan Regulator, Dimmar Switch type, 230 Volt AC, Rotary Stepped, Electronic type 120/280 Volt and connecting up, complete all as specified and as directed.
S&F Bell Ding Dong, 230 Volt AC, Single Pole and connecting up, complete all as specified and as directed.
S&F Ballast Electronic type, High Performance (THD 10%) 1x36 Watt (as approved) and connecting up including Taking down/o ut unserviceable Ballast, complete all as specified and as directed. MAKE : HAVELS, Cat No. LHBF07104026 or equivalent Model in Make : BAJAJ/ PHILIPS
S&F CFL 11 Watt, 230 Volt (as approved), suitable for fixing in existing Bulk Head Light Fitting including Taking down/out unserviceable CFL, complete all as specified and as directed.
S&F CFL 18 Watt, 4 Pin, 230 Volt (as approved), suitable for fixing in existing Bulk Head Light Fitting including Taking down/out unserviceable CFL, complete all as specified and as directed.
S&F CFL 36 Watt, 4 Pin, 420mm, 230 Volt (as approved), suitable for fixing in existing Light Fitting including Taking down/out unserviceable CFL, complete all as specified and as directed.
S&F LED Batten 20 Watt, 4 Feet long, 230 Volt (as approved), Cool Day Light Fitting suitable for fixing in existing Tube Light Fitting including Taking down/out unserviceable LED Batten, complete all as specified and as directed. MAKE : CG, Model : Eco LED Batten or equivalent in Make : C&S/HAVELS/ PHILIPS/ WIPRO
S&F LED Tube Light Rod 20 Watt, 4 Feet long, 230 Volt (as approved), suitable for fixing in existing Tube Light Fitting including Taking down/out unserviceable Tube Light Rod, complete all as specified and as directed.
S&F LED Light Fitting 1x9 Watt with LED Lamp 9 Watt, Mirror Fitting, Batten type, suitable for Surface Mounting, complete with all Accessories and Pre-wired, connecting up with and including Provision of suitable size Twin Core Twisted Flexible Copper Conductor Cable from Ceiling Rose to Light Fitting and Testingincluding Taking down/ out unserviceable Light Fitting, complete all as specified and as directed.
S&F Decorative LED Bulk Head Light Fitting 10 Watt with LED Lamp 10 Watt, made out of Polycarbonate, complete with all Accessories and connecting up including Taking down/out unserviceable Light Fitting, complete all as specified and as directed. MAKE : HAVELS, Model : Hexa 10W or equivalent Model in Make : CG/ C&S/ HPL
S&F Pluto Neo Flat Panel Slim type LED Light Fitting 15 Watt, 1x1 Luminaire having Lamp 400/6000K and Separate HF Electronic Driver, suitable for Ceiling mounted, complete with all Accessories, Pre-wired and connecting up with and including Provision of suitable size 2/3 Core Twisted Flexible Copper Conductor Cable including Taking down/ out unserviceable Light Fitting, complete all as specified and as directed.
S&F Pluto Neo Flat Panel Slim type LED Light Fitting 34 Watt, 2x2 Luminaire having Lamp 400/6000K and Separate HF Electronic Driver, suitable for Ceiling mounted, complete with all Accessories, Pre-wired and connecting up with and including Provision of suitable size 2/3 Core Twisted Flexible Copper Conductor Cable including Taking down/ out unserviceable Light Fitting, complete all as specified and as directed. MAKE : HAVELS, Cat No. LHEWEJP7PLIW034 or equivalent Model in Make : CG/ C&S/ HPL
S&F MCB 6 to 32 Amp, Single Pole, 'C' Series, 10 kA, 240 Volt and connecting up including Taking down/out unserviceable MCB, complete all as specified and as directed.
S&F MCB 40 Amp, Single Pole, 'C' Series, 10 kA, 240 Volt and connecting up including Taking down/out unserviceable MCB, complete all as specified and as directed.
S&F MCB 6 to 32 Amp, Single Pole & Neutral, 'C' Series, 10 kA, 240 Volt and connecting up including Taking down/out unserviceable MCB, complete all as specified and as directed.
S&F MCB 40 Amp, Single Pole & Neutral, 'C' Series, 10 kA, 240 Volt and connecting up including Taking down/out unserviceable MCB, complete all as specified and as directed.
S&F MCB 40 Amp, Triple Pole & Neutral, 'C' Series, 10 kA, 415 Volt and connecting up including Taking down/out unserviceable MCB, complete all as specified and as directed.
S&F Sheet Metal Enclosure, Single Pole with a 2-Pin and Earth Plug and Socket with and including 1 No. MCB Single Pole, 20 Amp, 240 Volt and Connecting up including Taking down/out unserviceable Sheet Metal Enclosure, complete all as specified and as directed. MAKE : HAVELS, Cat No. DHDPUSN020/DHDPUDPO20 or equivalent Model in Make : LEGRAND/ L&T/ SCHNEIDER (as approved by GE)
S&F Distribution Board Sheet Metal Enclosure, SPN, 2-way, 240 Volt, Factory made, Single Door with Steel Phosphotised Powder Painted having 200 Amp rated Neutral Bars & Earth Bar, fixed Flush with Wall Inside the Nitches or Outside on Wall Surface, suitable for Mounting Isolators & MCB's etc. and connecting up including Taking down/out unserviceable DB Sheet Metal Enclosure, complete all as specified and as directed.
S&F Distribution Board Sheet Metal Enclosure, SPN, 4-way, 240 Volt, Factory made, Single Door with Steel Phosphotised Powder Painted having 200 Amp rated Neutral Bars & Earth Bar, fixed Flush with Wall Inside the Nitches or Outside on Wall Surface, suitable for Mounting Isolators & MCB's etc. and connecting up including Taking down/out unserviceable DB Sheet Metal Enclosure, complete all as specified and as directed.
S&F Distribution Board Sheet Metal Enclosure, SPN, 8-way, 240 Volt, Factory made, Single Door with Steel Phosphotised Powder Painted having 200 Amp rated Neutral Bars & Earth Bar, fixed Flush with Wall Inside the Nitches or Outside on Wall Surface, suitable for Mounting Isolators & MCB's etc. and connecting up including Taking down/out unserviceable DB Sheet Metal Enclosure, complete all as specified and as directed.
S&F Vertical Distribution Board Sheet Metal Enclosure TPN, 4-way, 415 Volt, Factory made, Single Doors, Front Openable with Steel Phosphotised Powder Painted, having 200 Amp rated Neutral Bars & Earth Bar, fixed Flush with Wall Inside the Nitches or Outside on Wall Surface, suitable for Mounting Isolators & MCB's etc. and connecting up including Taking down/out unserviceable DB Sheet Metal Enclosure, complete all as specified and as directed.
Supply & Laying or Fixing or Passing through Pipe, 1100 Volt grade, Heavy duty Cable with PVC insulated Stranded Aluminium Conductor Served with an inner Sheathing of PVC Tape armoured with Galvanised Steel Wire or Tape and overall PVC Sheathed, Nominal Cross Section 6.0 Sqmm, 2 Core in Service Connections including Taking down unserviceable Service Connection Cable, complete all as specified and as directed.
Supply & Laying or Fixing or Passing through Pipe, 1100 Volt grade, Heavy duty Cable with PVC insulated Stranded Aluminium Conductor Served with an inner Sheathing of PVC Tape armoured with Galvanised Steel Wire or Tape and overall PVC Sheathed, Nominal Cross Section 10 Sqmm, 2 Core in Service Connections including Taking down unserviceable Service Connection Cable, complete all as specified and as directed.
M&L Earthing with Galvanised Earth Plate Electrode 600x600x6.0mm thick, buried directly in Ground vertically to a depth not less than 2.25 Metre below Ground Level with Top Edge of Earth Plate at depth not less than 1.50 Metre below normal Ground Level, connected to Galvanised Earth Lead Wire 4.0mm dia by means of Bolts, Nuts, Check, Nuts and Washers of Galvanised Iron or Steel and Earth Wire protected with and including GI Pipe 15mm bore (dia) Light grade, connected to Test Point upto 7.50 Metre away from Earth Electrode situated, Earth Plate surrounded by a packed thickness of Char Coal or Coke Dust mixed with Common Salt in alternate layers of not exc.150mm thick, PCC Pit in Cement Concrete 1:3:6 (20mm graded stone aggregate) and Pre-cast RCC Cover Slab of size 350x350x50mm in Cement Concrete 1:2:4 (20mm graded stone aggregate), reinforced with 10mm dia TMT Bars @ 100mm Centre to Centre in both ways, GI Wire Mesh, PGI Funnel with GI Watering Pipe 20mm bore (dia) Medium grade including necessary Excavation in Soft/ Loose Soil, Returning, Filling in and Removal of surplus Spoil upto a distance of 50.00 Metre and all as shown in Electrical Plate No. 3 of MES Schedule Part-I and Testing including Taking down/out unserviceable Earthing of any description, complete all as specified and as directed.
REPAIRS/MAINT TO FANS
M&L Taking down unserviceable Ceiling Fan, Exhaust Fan, Wall Mounted Fan, Air Circulator Fan of any Make & Size after disconnecting and removing to AGE E/M Store Yard at LIKABALI for Opening & Checking in presence of a Board of Officers to ascertain the quantum of Defects and Repair works involves, Re-hanging the same in Original Position after repaired and providing Electric Connection, complete all as specified and as directed. NOTE :- (a) Any Minor repairs involved to make the Fan completely Functional, even if not notified by the Board of Officers, the same shall be carried out by the Contractor without any Extra Cost to the Department. (b) Rewinding & Other Parts required to be replaced will be Measured and Paid separately as "S&F"/"M&L" under relevant Items.
S&F Ball Bearing (size as per existing one/ as approved) for Ceiling Fan 1200/1400mm Sweep including Taking down/out unserviceable Ball Bearing, complete all as specified and as directed. MAKE : FAG/ NBC/ SKF
S&F Condenser 2.5 mfd for Ceiling Fan & Wall Mounted Fan of any Make and Size including Taking down/out unserviceable Condenser, complete all as specified and as directed. MAKE : AMCAP/ EPCOS/ HAVELS
S&F Condenser 4.0 mfd for Exhaust Fan/ Air Circulator Fan of any Make and Size including Taking down/out unserviceable Condenser, complete all as specified and as directed. MAKE : AMCAP/ EPCOS/ HAVELS
S&F Fan Blade Aluminium for Ceiling Fan 1200mm Sweep of any Make/ Model, Aero dynamically balanced and screwed with suitable size Mild Steel Screws including Taking down/out unserviceable Fan Blade, complete all as specified and as directed.
S&F Gun Metal Bush (size as per existing One/ as approved) for Cabin/ Ceiling/ Exhaust Fan of any Make/Model and any Size including Taking down/out unserviceable Bush, complete all as specified and as directed. MAKE : FAG/ NBC/ SKF
M&L Mild Steel Down Rod 15mm nominal dia and 300mm to 450mm long, heavy duty, duly painted in matching Colour of Fan including Taking down/out unserviceable Down Rod, complete all as specified and as directed.
S&F Oscilating Mechanism for Wall Fan 400mm Sweep including Taking down/out unserviceable Oscilating Mechanism, complete all as specified and as directed.
S&F Rubber Bush (Reel type) standard size and type duly fixed with suitable size Mild Steel Bolt, Nuts, etc. including Taking down/out unserviceable Rubber Bush, complete all as specified and as directed.
M&L Transporting Ceiling Fan 1200mm Sweep from AGE E/M Store Yard at LIKABALI to nearest Workshop, Removing burnt Winding of any type, Cleaning Slot, Rewinding Fan Motor with Super Enamalled Copper insulated Wire of suitable Gauge and Weight (as per existing) providing necessary Insulation Materials, Varnishing, Heating, Reassembling & Testing for Smooth Functioning after Rewinding, Removing the Fan to Site of Work after Rewinding, complete all as specified and as directed.
M&L Transporting Ceiling Fan 1400mm Sweep from AGE E/M Store Yard at LIKABALI to nearest Workshop, Removing burnt Winding of any type, Cleaning Slot, Rewinding Fan Motor with Super Enamalled Copper insulated Wire of suitable Gauge and Weight (as per existing) providing necessary Insulation Materials, Varnishing, Heating, Reassembling & Testing for Smooth Functioning after Rewinding, Removing the Fan to Site of Work after Rewinding, complete all as specified and as directed.
M&L Transporting Exhaust Fan 250/300/350mm Sweep from AGE E/M Store Yard at LIKABALI to nearest Workshop, Removing burnt Winding of any type, Cleaning Slot, Rewinding Fan Motor with Super Enamalled Copper insulated Wire of suitable Gauge and Weight (as per existing) providing necessary Insulation Materials, Varnishing, Heating, Reassembling & Testing for Smooth Functioning after Rewinding, Removing the Fan to Site of Work after Rewinding, complete all as specified and as directed.
M&L Transporting Wall/ Cabin Fan 400mm Sweep from AGE E/M Store Yard at LIKABALI to nearest Workshop, Removing burnt Winding of any type, Cleaning Slot, Rewinding Fan Motor with Super Enamalled Copper insulated Wire of suitable Gauge and Weight (as per existing) providing necessary Insulation Materials, Varnishing, Heating, Reassembling & Testing for Smooth Functioning after Rewinding, Removing the Fan to Site of Work after Rewinding, complete all as specified and as directed.
M&L Taking down Ceiling Fan of any Sweep from any Situation after disconnect -ing, Preparing old Painted Surfaces of Fan including Cleaning, Washing, Rubbing and Filling Cavities with Filler, applying One Coat of Synthetic Enamelled Paint (as approved) with Spray Painting Machine and Writing MES No. with Black Paint, Re-hanging the Fan in Original Postion & Re-connecting and Testing, complete all as specified and as directed.
S&F PVC Stranded Copper Conductor Flexible Cable 1.5 Sqmm 3 Core for Electric Connection including Taking down unserviceable Cable, complete all as specified and as directed.
REPAIRS/MAINT TO GEYSERS
M&L Taking down/Lowering Defective Water Heater of any Capacity/ Make/ Type from any Height by disconnecting all Water and Electric Connections, Opening & Checking in presence of a Board of Officers to ascertain the quantum of Defects and Repair Works involves, Repairing/ Replacing of unserviceable Accessories, Removing all Rusted Nuts, Bolts, de-scaling Inner Tank & Inter Connection Assembly, Cleaning thoroughly with Diluted Acid, Brazing/Gas welding of Inter Connection Assembly, Checking of Inner Tank to make Fully Leakeage Proof and Testing the same with Water Filling/Air Pressure, Re-fixing/ Re-mounting the same in Original Position and providing necessary Water/ Electric Connection and Testing on Completion, complete all as specified and as directed. NOTE :- (a) Any Minor repairs involves to make the Water Heater (Geyser) completely Functional, even if not notified by the Board of Officers, the same shall be carried out by the Contractor without any Extra Cost to the Department. (b) Parts required to be replaced will be Measured and Paid separately as "S&F" under relevant Items and Quantities are Provisional.
S&F Heating Element 1.5 KW 230 Volt AC for Electric Water Heater 25 Litre capacity of any Make/Model including Taking down/out unserviceable Heating Element, complete all as specified and as directed. MAKE : BAJAJ/ DITZ/ POWER PACK/ THEETA
S&F Heating Element 2.0 KW 230 Volt AC for Electric Water Heater 25 Litre capacity of any Make/Model including Taking down/out unserviceable Heating Element, complete all as specified and as directed. MAKE : BAJAJ/ DITZ/ POWER PACK/ THEETA
S&F Indication Lamp Rounded type 230 Volt suitable for Water Heater (Geyser) of any capacity, any Make including Taking down/out unserviceable Indication Lamp, complete all as specified and as directed.
S&F Pressure Release Valve Dead Weight type for Water Heater (Geyser) of any capacity, any Make including Taking down/out unserviceable Pressure Release Valve, complete all as specified and as directed.
S&F Thermostate Switch with Thermal Setting 40 °C to 90 °C capacity and Relay 230 Volt AC for Electric Water Heater of any Capacity/ Make/ Model including Taking down/out unserviceable Thermostate Switch, complete all as specified and as directed.
M&L Repairs to Water Heater of any capacity and type by Taking out Unservice-able Water Tank (Inner Shell), brazing to leaking Portion or Patching Work as required with using Copper Plate 1.5mm thick including shaping to Original size, complete all as specified and as directed.
S&F PVC Connection in Inlet, 15mm bore (dia) and 450mm in length with PTMT Nuts suitable for Cold/Hot Water including Taking down/out unserviceable PVC Connection, complete all as specified and as directed.
S&F PVC Pipe 15mm bore (dia), heavy duty for Inlet and Outlet Connections suitable for Water Heater (Geyser) including Taking down/out unserviceable PVC Pipe, complete all as specified and as directed.
REPAIRS/MAINT TO AIR CONDITIONERS
M&L Taking down/ Lowering Defective Split AC 1.5/2.0 Ton Capacity of any Make from any Height by disconnecting all Electric Connections, Opening & Checking in presence of a Board of Officers to ascertain the quantum of Defects & Repair Works involves, Repairing/Replacing of unserviceable Parts, Cleaning thoroughly Condensing Unit to achive Proper Cooling effect, Checking of Electronic Circuit of Machine, Changing of Wiring with proper size PVC insulated Copper Wires, Brazing the Suction/ Discharge Tubes (as required) and Making the System Fully Leakeage Proof, Re-install the Same in Original/ New Position and providing necessary Electric Connection, Testing on Completion, complete all as specified and as directed. NOTE :- (a) Any Minor repairs involves to make the Split AC 1.5/2.0 Ton Capacity Functional, even if not notified by the Board of Officers, the same shall be carried out by the Contractor without any Extra Cost to the Department. (b) Compressor & Other Parts and Charging of Refrigerent as required will be Measured and Paid separately as 'S&F'/ 'M&L' and 'Supply & Charging' under relevant Items and the Quantities are Provisional.
M&L Complete Servicing Indoor & Outer Unit of Split type AC 1.5 Ton/ 2.0 Ton Capacity of any Make & Model in Situ by Cleaning, Changing of Air Filter in Indoor Unit and Testing, complete all as specified and as directed. NOTE : Air Filter will be Measured & Paid separately as "S&F" under relevant Items and the Quantities are Provisional.
S&F Air Filter (as per existing One/ as approved) to match the Same Model & Capacity and to fit with Indoor Unit of Split type AC 1.5 Ton/ 2.0 Ton Capacity with necessary necessary Connection & Testing including Taking down/ out unserviceable Air Filter, complete all as specified and as directed.
M&L Auto Sensor Unit & RC (as per existing One/ as approved) for Split type AC 1.5 Ton/ 2.0 Ton and providing necessary Connections & Testing including Taking down/out unserviceable Sensor Unit, complete all as specified and as directed.
M&L Blower Motor with Extended Shaft and Rotary Blade Complete (as per existing One/ as approved), Single Phase, 230 Volt, AC to match the Same Model & Capacity for Indoor Unit of Split type AC 1.5 Ton/ 2.0 Ton Capacity with necessary necessary Connection & Testing including Taking down/ out unserviceable Blower Motor, complete all as specified and as directed.
M&L Capacitor 1.5/2.0 mfd (as per existing One/ as approved) 230 Volt, 50 Hz for Split type AC 1.5 Ton/ 2.0 Ton Capacity and providing necessary Connections & Testing including Taking down/ out unserviceable Capacitor, complete all as specified and as directed. MAKE : KELTRON/ SARDA/ SIEMENS/ USHA
M&L Capacitor 4.0/6.0 mfd (as per existing One/ as approved) 230 Volt, 50 Hz for Split type AC 1.5 Ton/ 2.0 Ton Capacity and providing necessary Connections & Testing including Taking down/ out unserviceable Capacitor, complete all as specified and as directed. MAKE : KELTRON/ SARDA/ SIEMENS/ USHA
M&L Running Capacitor 45/ 50/ 60 mfd (as per existing One/ as approved) 230 Volt, 50 Hz for Split type AC 1.5 Ton/ 2.0 Ton Capacity and providing necessary Connections & Testing including Taking down/ out unserviceable Capacitor, complete all as specified and as directed. MAKE : KELTRON/ SARDA/ SIEMENS/ USHA
M&L Compressor Sealed Unit, Rotary type (as per existing One/ as approved) to match the Same Model & Capacity for Split AC 1.5 Ton Outdoor Unit with All Accessories including necessary Brazing to Stop Leakage & Testing including Taking down/ out unserviceable Compressor, complete all as specified and as directed. MAKE : CARRIER/ HITACHI/ KIRLOSKAR/ TECUMSEH
M&L Compressor Sealed Unit, Rotary type (as per existing One/ as approved) to match the Same Model & Capacity for Split AC 2.0 Ton Outdoor Unit with All Accessories including necessary Brazing to Stop Leakage & Testing including Taking down/ out unserviceable Compressor, complete all as specified and as directed. MAKE : CARRIER/ HITACHI/ KIRLOSKAR/ TECUMSEH
M&L Cooling Coil/ Condensing Unit (as per existing One/ as approved) to match the Same Model & Capacity for Split type AC 1.5 Ton/ 2.0 Ton Capacity with necessary Connection & Testing including Taking down/ out unserviceable Cooling Coil/ Condensing Unit, complete all as specified and as directed.
M&L Fan Motor with Blade (as per existing One/ as approved) to match the Same Model & Capacity for Outdoor Unit of Split type AC 1.5 Ton /2.0 Ton Capacity with necessary Connection & Testing including Taking down/ out unserviceable Fan Motor, complete all as specified and as directed.
M&L Indoor Unit Complete Set (as per existing One/ as approved) to match the Same Model & Capacity for Split type AC 2.0 Ton Capacity with necessary Connection & Testing including Taking down/ out unserviceable Indoor Unit, complete all as specified and as directed.
M&L Universal Strainer Cum Dryer (as per existing One/ as approved) for Split type AC 1.5 Ton and providing necessary Connections & Testing including Taking down/out unserviceable Universal Strainer, complete all as specified and as directed.
Supply & Charging of Refrigerant F-22 to Split type AC 1.5 Ton/ 2.0 Ton Capacity, Testing on Completion, complete all as specified and as directed.
Supply & Charging of Refrigerant F-22 to Split type AC 1.5 Ton/ 2.0 Ton Capacity after Cleaning of Condenser Unit, Evoporator Unit, Brazing to Stop the Leakage of Suction/ Discharge Tubes (as required) and Making the System Fully Leakeage Proof and Vaccuming, Testing on Completion, complete all as specified and as directed.
M&L Shifting Split type AC 1.5 Ton/ 2.0 Ton Capacity Outer Unit with All Accessories including necessary Gas Charging, Welding, Brazing to Stop Leakage Vacum Test Pressure, Testing, insisting thick Flexible Thermocool and Servicing of Indoor and Outdoor Unit, complete all as specified and as directed.
REPAIRS/MAINT TO REFRIGERATORS
M&L Opening Defective Refrigerator 165 to 324 Litre Capacity of any Make/ Model/ Type, Removal of Blockage by Flushing Out, Brazing (as required) and Making the System Fully Leakeage Proof, Replacing unserviceable Compressor & Other Parts and Re-assembling after necessary repaired & Testing, complete all as specified and as directed. NOTE :- (a) Any Minor repairs involves to make the Refrigerator Functional, even if not notified by JE/ Engineer-in-Charge, the same shall be carried out by the Contractor without any Extra Cost to the Department. (b) Compressor & Other Parts and Charging of Refrigerent as required will be Measured and Paid separately as 'S&F'/ 'M&L' and 'Supply & Charging' under relevant Items and the Quantities are Provisional.
M&L Complete Servicing Refrigerator 165 to 324 Litre Capacity of any Make/ Model/ Type in Situ by Cleaning Condenser Unit, Cooling Coil and Internal Parts, Testing on Completion, complete all as specified and as directed.
M&L Bimetal Switch (as per existing One/ as approved) to match the Same Model & Capacity for Refrigerator 165 to 324 Litre Capacity of any Make/ Model/ Type, Testing on Completion including Taking down/ out unserviceable Bimetal Switch, complete all as specified and as directed.
M&L Capacitor 1.5/2.0 mfd (as per existing One/ as approved) for Refrigerator 165 to 324 Litre Capacity of any Make/ Model/ Type, Testing on Completion including Taking down/ out unserviceable Capacitor, complete all as specified and as directed.
M&L Compressor Sealed Unit (as per existing One/ as approved) to match the Same Model & Capacity for Refrigerator 165 to 324 Litre Capacity of any Make/ Model/ Type, Testing on Completion including Taking down/ out unserviceable Compressor, complete all as specified and as directed.
M&L Cooling Coil (as per existing One/ as approved) to match the Same Model & Capacity for Refrigerator 280 to 324 Litre Capacity of any Make/ Model/ Type, Testing on Completion including Taking down/ out unserviceable Cooling Coil, complete all as specified and as directed.
M&L Fan Motor with Blade for Evoporator Unit (as per existing One/ as approved) to match the Same Model & Capacity for Refrigerator 280 to 324 Litre Capacity of any Make/ Model/ Type, Testing on Completion including Taking down/ out unserviceable Fan Motor, complete all as specified and as directed.
S&F Heating Element 20-45 W (Glass Protected Insulation type) to match the Same Model & Capacity for Refrigerator 280 to 324 Litre Capacity of any Make/ Model/ Type, Testing on Completion including Taking down/ out unserviceable Heating Element, complete all as specified and as directed.
S&F Relay (as per existing One/ as approved) to match the Same Model & Capacity for Refrigerator 165 to 324 Litre Capacity of any Make/ Model/ Type, Testing on Completion including Taking down/ out unserviceable Relay, complete all as specified and as directed.
S&F Thermostate Switch (as per existing One/ as approved) to match the Same Model & Capacity for Refrigerator 165 to 324 Litre Capacity of any Make/ Model/ Type, Testing on Completion including Taking down/ out unserviceable Thermostate Switch, complete all as specified and as directed.
Supply & Charging of Refrigerant F-22 to Refrigerator 165 to 324 Litre Capacity of any Make/ Model/ Type after Cleaning of Condenser Unit, Evoporator Unit, Brazing to Stop the Leakage of Suction/ Discharge Tubes (as required) and Making the System Fully Leakeage Proof and Vaccuming, Testing on Completion, complete all as specified and as directed.
REPAIRS/MAINT TO WATER COOLERS
M&L Opening Defective Water Cooler of any Capacity/ Make/ Model/ Type for Checking/ Repairing, Removal of Blockage by Flushing Out, Brazing (as required) Suction & Discharge Pipes for Making the System Fully Leakeage Proof, Cleaning thoroughly Cooling Coil to achive Proper Cooling effect, Replacing unserviceable Compressor & Other Parts and Re-assembling after necessary repaired & Testing, complete all as specified and as directed. NOTE :- (a) Any Minor repairs involves to make the Water Cooler Functional, even if not notified by JE/ Engineer-in-Charge, the same shall be carried out by the Contractor without any Extra Cost to the Department. (b) Compressor & Other Parts and Charging of Refrigerent as required will be Measured and Paid separately as 'S&F'/ 'M&L' and 'Supply & Charging' under relevant Items and the Quantities are Provisional.
M&L Complete Servicing of Water Cooler of any Capacity/ Make/ Type in Situ by Cleaning Condenser Unit, Fan Motor & Blade, Base Plate including Repairs to Storage Tank, complete all as specified and as directed.
M&L Blower Motor with Blade, Single Phase, 1325 RPM, 230 Volt, 50 Hz (as per existing One/ as approved) for Water Cooler of any description, Providing necessary Connections & Testing including Taking down/ out unserviceable Blower Motor, complete all as specified and as directed.
M&L Compressor Sealed Unit (as per existing One/ as approved), Single Phase for Water Cooler 40/80 Litre Capacity, Providing necessary Connections & Testing including Taking down/ out unserviceable Compressor, complete all as specified and as directed. MAKE : EMERSON/ HITACHI/ KIRLOSKAR/ SHRIRAM/ TECHEMSHAH
M&L Compressor Sealed Unit (as per existing One/ as approved), Single Phase for Water Cooler 60/120 Litre Capacity, Providing necessary Connections & Testing including Taking down/ out unserviceable Compressor, complete all as specified and as directed. MAKE : EMERSON/ HITACHI/ KIRLOSKAR/ SHRIRAM/ TECHEMSHAH
M&L Over Load Protector to Compressor Sealed Unit (as per existing One/ as approved) for Water Cooler of any description, Providing necessary Connections & Testing including Taking down/ out unserviceable Over Load Protector, complete all as specified and as directed. MAKE : HITACHI/ SHRIRAM/ TECHEMSHAH
M&L Running Capacitor 10 mfd (as per existing One/ as approved) 400/ 440 Volt AC for Water Cooler of any description, Providing necessary Connections & Testing including Taking down/ out unserviceable Running Capacitor, complete all as specified and as directed. MAKE : KELTRON/ SARDA/ SIEMENS/ USHA
M&L Thermostatic Switch (as per Existing One/ as approved) for Water Cooler of any description, Providing necessary Connections & Testing including Taking down/ out unserviceable Thermostatic Switch, complete all as specified and as directed. MAKE : DENFOS/ GODREJ/ INDOFOSS/ RENUTRAL
Supply & Charging of Refrigerant F-22 to Water Cooler of any Capacity/Make/ Model/ Type after Cleaning of Condenser Unit, Cooling Coil, Brazing to Stop the Leakage of Suction/ Discharge Tubes (as required) and Making the System Fully Leakeage Proof and Vaccuming, Testing on Completion, complete all as specified and as directed.
M&L Push Cock 15mm bore (dia) Brass Chromium plated, having Inner or Outer threaded and fitted to Water Cooler of any description including Taking down/ out unserviceable Push Cock, complete all as specified and as directed. MAKE : BAJAJ/ ESCO/ ESSESS/ JAI
M&L PVC Float Valve Assembly 15mm bore (dia) with Valve Assembly, Aluminum Rod, PVC Ball, fixing to Water Cooler of any description including Taking down/ out unserviceable Float Valve Assembly, complete all as specified and as directed.
REPAIRS/MAINT TO DEEP FREEZERS
M&L Opening Defective Deep Freezer 200/400 Litre Capacity of any Make/ Model/ Type, Removal of Blockage by Flushing Out, Brazing (as required) Suction & Discharge Pipes for Making the System Fully Leakeage Proof, Cleaning thoroughly Cooling Coil to achive Proper Cooling effect, Checking of Electronic Circuit of Machine, Changing of Wiring with proper size PVC insulated Copper Wires, Replacing unserviceable Compressor & Other Parts and Re-assembling after necessary repaired & Testing, complete all as specified and as directed. NOTE :- (a) Any Minor repairs involves to make the Deep Freezer Functional, even if not notified by JE/ Engineer-in-Charge, the same shall be carried out by the Contractor without any Extra Cost to the Department. (b) Compressor & Other Parts and Charging of Refrigerent as required will be Measured and Paid separately as 'S&F'/ 'M&L' and 'Supply & Charging' under relevant Items and the Quantities are Provisional.
M&L Complete Servicing Deep Freezer 200/400 Litre Capacity of any Make/ Type in Situ by Cleaning Condenser Unit, Fan Motor with Blade, Base Plate, etc. Complete Testing for Proper Functioning, achiving Proper Cooling effect including necessary Repairs to Deep Freezer and Testing, complete all as specified and as directed.
M&L Compressor Sealed Unit (as per existing One/ as approved), Single Phase for Deep Freezer 310/320 Litre Capacity of any Make/ Type, Providing necessary Connections & Testing including Taking down/ out unserviceable Compressor, complete all as specified and as directed. MAKE : EMERSON/ HITACHI/ KIRLOSKAR/ SHRIRAM/ TECHEMSHAH
M&L Fan Motor with Blade, Single Phase, 230 Volt AC, 50 Hz (as per existing One/ as approved) to match the Same Model & Capacity for Deep Freezer 200/400 Litre Capacity of any Make/ Type, Testing on Completion including Taking down/ out unserviceable Fan Motor, complete all as specified and as directed.
S&F Relay (as per existing One/ as approved) to match the Same Model & Capacity for Deep Freezer 200/400 Litre Capacity of any Make/ Type, Testing on Completion including Taking down/ out unserviceable Relay, complete all as specified and as directed.
S&F Thermostate Switch (as per existing One/ as approved) tto match the Same Model & Capacity for Deep Freezer 200/400 Litre Capacity of any Make/ Type, Testing on Completion including Taking down/ out unserviceable Thermostate Switch, complete all as specified and as directed.
Supply & Charging of Refrigerant F-22 to Deep Freezer 200/400 Litre Capacity of any Make/ Type after Cleaning of Condenser Unit, Evoporator Unit, Brazing to Stop the Leakage of Suction/ Discharge Tubes (as required) and Making the System Fully Leakeage Proof and Vaccuming, Testing on Completion, complete all as specified and as directed.
REPAIRS/MAINT TO VOLTAGE STABILIZER & MISC ITEMS
M&L Dismantling Voltage Stabilizer 3.0 KVA Capacity, Single Phase, 240 Volt AC, Repairing as required, Replacing burnt Transformer Copper wounded, Electronic Circuit, Relays, Indicator Light, Voltmeter, Display, Switch & Socket, etc. to provide Correct Stabilised 230 Voltage, Re-assembling the Voltage Stabilizer after Repaired/ Replacement, Re-installed & Testing, complete all as specified and as directed. NOTE : Cost of All Materials & Labour Elements required for Making the Stabilizer Functional, shall deem to be included in the Quoted Unit Rate.
M&L Dismantling Voltage Stabilizer 5.0 KVA Capacity, Single Phase, 240 Volt AC, Repairing as required, Replacing burnt Transformer Copper wounded, Electronic Circuit, Relays, Indicator Light, Voltmeter, Display, Switch & Socket, etc. to provide Correct Stabilised 230 Voltage, Re-assembling the Voltage Stabilizer after Repaired/ Replacement, Re-installed & Testing, complete all as specified and as directed. NOTE : Cost of All Materials & Labour Elements required for Making the Stabilizer Functional, shall deem to be included in the Quoted Unit Rate.
M&L Sub-main Wiring with 2-Runs of 6.0 Sqmm (nominal area) 1100 Volt PVC insulated unsheathed FRLS multi-stranded Single Core Copper Conductor Cable and 1-Run of 4.0 Sqmm (nominal area) 1100 Volt PVC insulated unsheathed FRLS multi-stranded Single Core Copper Conductor Cable (Green Colour) as Earth Continuty Conductor drawn through and including PVC Casing Capping (ISI Marked) of suitable size (approx 25/32mm width) along with all Fitting/ Fixtures as Tee, Bend, Elbow, Socket, Saddles, etc. (White/ Ivory/ Off White in Colour) and Making Good Disturbed Surfaces of Walls/ Roofs/ Floors, etc. so as to match with the Existing Finishes, complete all as specified and as directed. NOTE :- (a) Cost of 3-Runs of Cables & 1-Run of PVC Casing Capping shall deem to be included in the Quoted Unit Rate and the same also Mesured as ONE UNIT (b) Sub-main Wiring will be measured existing PVC Conduit only. Wire required for looping, etc. as ordered will deem to be included in the Quoted Unit Rate.
M/s PRABIR ENTERPRISE
M/S S. P. ENTERPRISE
DEBSON CONSTRUCTION
MAZUMDAR ENTERPRISE
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .