Loading…
Loading…
Tender ID
Tender Value
₹10 L
EMD Value
₹20,000
Closing Date
25 Mar 2026, 3:00 pmClosed
VIKAS DHANKHAR
Bhiwani PHED No. 1
AMtc Sewerage Scheme Bhiwani Town Repairing, overhauling testing and commissioning of 100 BHP 75 BHP and 30 BHP Sewerage submersible pump motor installed at MPS 45 MLD and IPS Govt college Hansi Road including starter panel in Bhiwani Town and all o
2026_HRY_508300_1
20261022B08A 845C 48A7 8D5B E1FAB167D0F0553PUH
Open Tender
Civil Works
Works
30 days
Bhiwani
AMtc Sewerage Scheme Bhiwani Town Repairing, overhauling testing and commissioning of 100 BHP 75 BHP and 30 BHP Sewerage submersible pump motor installed at MPS 45 MLD and IPS Govt college Hansi Road including starter panel in Bhiwani Town and all o
2 documents required · 2 mandatory
₹1,000
₹20,000
Yes
1 Apr 2026
13 Mar 2026
25 Mar 2026
13 Mar 2026
25 Mar 2026
13 Mar 2026
Select, Excess (+), Less (-) Less (-)
Tender Inviting Authority: EE PHED No.1 - Bhiwani
Name of Work A/Mtc. Sewerage Scheme Bhiwani Town. Repairing, overhauling, testing and commissioning of 100 BHP, 75 BHP and 30 BHP Sewerage submersible pump motor installed at MPS 45 MLD and IPS Govt. college Hansi Road including starter panel in Bhiwani Town and all other works contingent thereto Rs. 10.00 lacs
Name of the Bidder/ Bidding Firm / Company :
Sl. No. Item Description NS Item Item Code / Make Quantity Units Estimated Rate in Rs. P Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency BASIC RATE In Figures To be entered by the Bidder in Rs. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category
1.1 Repair and restoration of 100 BHP sewerage submersible pump motor including dismantling and inspection of motor, transportation charges, rewinding of motor with superior grade copper winding, replacement of damaged bearings, insulation before and after rewinding, replacement of gland packing, replacement of shaft sleeves, replacement of O-rings, gas kits and sealing components, terminal connections, re-installation and alignment with pump, trial run and load testing with satisfaction of Engineer-In-Charge BI01010001010000000000000515BI0100001113 0.000 Per Job Full Conversion INR
1.2 Repair and restoration of 75 BHP sewerage submersible pump motor including dismantling and inspection of motor, transportation charges, rewinding of motor with superior grade copper winding, replacement of damaged bearings, insulation before and after rewinding, replacement of gland packing, replacement of shaft sleeves, replacement of O-rings, gas kits and sealing components, terminal connections, re-installation and alignment with pump, trial run and load testing with satisfaction of Engineer-In-Charge BI01010001010000000000000515BI0100001114 0.000 Per Job Full Conversion INR
1.3 Repair and restoration of 30 BHP sewerage submersible pump motor including dismantling and inspection of motor, transportation charges, rewinding of motor with superior grade copper winding, replacement of damaged bearings, insulation before and after rewinding, replacement of gland packing, replacement of shaft sleeves, replacement of O-rings, gas kits and sealing components, terminal connections, re-installation and alignment with pump, trial run and load testing with satisfaction of Engineer-In-Charge BI01010001010000000000000515BI0100001115 0.000 Per Job Full Conversion INR
1.4 Repairing, servicing and overhauling of 100 BHP starter panel for sewerage submersible pump motor including complete inspection and fault diagnosis, dismantling and replacement of defective components (MCCB/MCB, Power contactors, Over load relay, star delta timer, Selector switches, fuse holders and terminal blocks if required) panel servicing, testing and commissioning, complete safety measures with satisfaction of Engineer-In-Charge BI01010001010000000000000515BI0100001116 0.000 Per Job Full Conversion INR
1.5 Repairing, servicing and overhauling of 75 BHP starter panel for sewerage submersible pump motor including complete inspection and fault diagnosis, dismantling and replacement of defective components (MCCB/MCB, Power contactors, Over load relay, star delta timer, Selector switches, fuse holders and terminal blocks if required) panel servicing, testing and commissioning, complete safety measures with satisfaction of Engineer-In-Charge BI01010001010000000000000515BI0100001117 0.000 Per Job Full Conversion INR
Total in Figures
Quoted Rate in Figures Select
Please Enable Macros to View BoQ information
stage.html
html • 0.02 MB
cancelled_1.pdf
pdf • 0.15 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.69 MB
BOQ_587069.xls
BOQ • 0.23 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .