Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹22.0 LAccepted-AOC | L1 | Accepted-AOC Become lowest bidder | |
| 2 | L2₹22.7 L+₹37,018 (1.66%)Rejected-Finance 840 1B MADHUR VIHAR COLONY CIVIL LINES JHANSI UP 284 001 | JHANSI | JHANSI | UTTAR PRADESH | 284001 | L2 | Rejected-Finance Not become lowest bidder | |
| 3 | L3₹22.9 L+₹57,325 (2.57%)Rejected-Finance D12 GROTH CENTRE COLONY BIJAULI JHANSI U P | JHANSI | UTTAR PRADESH | 284001 | L3 | Rejected-Finance Not become lowest bidder | |
| 4 | L4₹29.6 L+₹7.3 L (32.9%)Rejected-Finance 01 MITHAPUR B AREA NAHARPAR BEHIND OF BHANA MILE MITHAPUR MITHAPUR MITHAPUR B AREA NAHARPAR PATNA BIHAR 800001 | PATNA | BIHAR | 800001 | L4 | Rejected-Finance Not become lowest bidder |
Tender Value
Refer Docs
EMD Value
₹47,540
Closing Date
19 Oct 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Major Deepak Kumar
Garrison Engineer Jhansi
SPECIAL REPAIR FOR REPLACEMENT OF SHADOW LESS LIGHT FITTING FOR OPERATION THEATRE OF MH JHANSI, REPLACEMENT OF EXISTING DBS, CHANGE OVER SWITCH AND SUB MAIN WIRING FOR A MESS AND OTHER REVENUE WORKS AND MINOR WORKS UNDER AGE E/M AT GE JHANSI
2020_MES_371746_2
GE/JHA/TOK/34 OF 2020-21
Open Tender
Civil Works
Item Rate
180 days
GE Jhansi
Please refer tender documents
6 documents required · 6 mandatory
₹500
Yes
GE Jhansi
₹47,540
Yes
29 Dec 2020
3 Oct 2020
21 Oct 2020
3 Oct 2020
19 Oct 2020
6 Oct 2020
60 days
Amount
Taking down old unserviceable OT light complete of any type / size / capacity from ceiling of OT and making good of disturbed surface of ceiling / wall for taking credit complete all as directed.
Supply, installation, commissioning and testing of LED based ceiling suspended double dome Operation Theatre (OT) Light with each dome consisting of minimum 40-50 LED’s housed in dome with diameter ranging between 500mm - 600mm, giving a Lux output ≥ 1,40,000 Lux @ 1 meter distance suspended through a ceiling assembly with spring arm system to provide precise positioning of the OT light as required during surgery complete with UPS including Sealed Maintenance Free Batteries to provide instantaneous backup in case of power failure for 30 minutes complete with all necessary wiring and hanging arrangements as per manufacturers guidelines with the minimum specifications given at Particular Specifications (for Major OT)- Make : Stryker / Steris / Hospedia Medicare / Dr. Mach
Supply, installation, commissioning and testing of LED based ceiling suspended single dome Operation Theatre(OT) Light consisting of minimum 40-50 LED’s housed in dome with diameter ranging between 500mm - 600mm, giving a Lux output ≥ 1,40,000 Lux @ 1 meter distance suspended through a ceiling assembly with spring arm system to provide precise positioning of the OT light as required during surgery complete with UPS including Sealed Maintenance Free Batteries to provide instantaneous backup in case of power failure for 30 minutes complete with all necessary wiring and hanging arrangements as per manufacturers guidelines with the minimum specifications given at Particular Specifications (for Minor OT)- Make : Stryker / Steris / Hospedia Medicare / Dr. Mach
Taking down of existing unserviceable sub main wiring of any description and making good the disturbed surfaces to match with the existing surfaces with cement plaster / putty / distemper complete all as directed by Engineer -in - Charge.
Material and labour for sub main wiring with 2runs x 4 sqmm(Ph & N) + 1run x 4 sqmm(earth wire) with FRLS insulated copper conductor, single core cable drawn through and including medium grade rigid PVC conduit conforming to IS:9537 (Pt-III) and its all accessories/junction boxes/ inspection covers etc of suitable size but not less than 25mm concealed in wall/ floor etc complete all as specified and directed by Engineer-in-Charge for the following sizes (Make of Conduit-AKG/ Atul/ Kalinga/Modi/Precision and Make of Wire - Havells/ Polycab/ Finolex / KEI / Gloster) :- Note: (i) Three runs of copper cable and one run of PVC conduit shall be measured as one unit length. (ii) Quoted rate shall deemed to include the cost of cutting chases on wall/floor for concealed conduit wiring and making good with cement plaster, putty and paint to match with the existing surface. (iii) If any beam / slab / column / Rock wall is encountered while cutting chases, that particular portion may be provided with PVC casing & capping or surface conduit for drawing cables to avoid any damage to the structure.
Taking down existing unserviceable service cable of any description and Supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty cable with XLPE insulated stranded aluminium conductor served with an inner sheathing of PVC tape armoured with galvanized steel wire or strip and overall PVC sheathed, as per IS 7098(Part 1) including connecting on LT OH line / LT panel /DB with suitable lugs, glands, binding wire etc complete all as specified and directed for the following size of cable:- Make: Polycab / Gloster / Universal / Havells / KEI
16 sqmm, 4 core
25 sqmm, 4 core
35 sqmm, 3.5 core
M&L for High density polyethylene pipes (HDPE) 50mm dia of pressure rating 6 kgf/cm2 laid in trenches/floors/duct or fixed on walls /pole for cable protection complete all as specified and directed. Make: Finolex / Kisan / Prince / Tirupati /Supreme / Jain Irrigation Sys
Excavation in trenches not exc 1.5 m wide and not exc 1.5 m depth for laying of Cable / Pipe and getting out in any type of soil complete all as specified and directed by Engineer-in-Charge.
Returning, filling in, including leveling, watering and well ramming in layers not exc 25 cm complete all as specified and directed by Engineer-in-Charge.
Removing excavated material not exc 50m and depositing where directed at a level not exc 1.5m above the starting point complete all as specified and directed by Engineer-in-Charge.
M&L for cutting of existing road / hard standing up to 15 cm depth for laying of pipe lines and making good the disturbed surfaces by providing PCC 1:2:4 type B-1 (using 20mm graded aggregate) after laying of cables / pipe lines and returning filling of soil, complete all as specified and directed. Note:- Excavation and earth work below road / hard standing will be measured and paid sepearate under relevant items.
Supply and fix in replacement of on-load change over switch, 200A, 4 pole, 415V, 50 Hz in sheet steel enclosure with front operated handle including taking down existing unserviceable changeover switch of any description complete all as specified and directed by Engineer-in-Charge. Make : Standard / Indo Asian / L&T / Havells
Supply and fix in replacement of MCCB / MCB distribution board, Vertical TPN, 4 way with MCCB as incomer and MCBs as outgoing in sheet steel powder painted enclosure double door type with minimum IP 43 degree of protection with built in copper bus bar, neutral link and earth link complete including cutting the wall surfaces for flush mounting of DB and making good with cement plaster, putty and paint to match with the existing surface including taking down existing unserviceable MCB DB of any description complete all as specified and directed by Engineer-in-Charge. Note: MCCB / MCBs shall be measured and paid separately. Make : Standard / Indo Asian / L&T / Havells
Supply and fix in replacement of MCCB / MCB distribution board, Vertical TPN, 8 way with MCCB as incomer and MCBs as outgoing in sheet steel powder painted enclosure double door type with minimum IP 43 degree of protection with built in copper bus bar, neutral link and earth link complete including cutting the wall surfaces for flush mounting of DB and making good with cement plaster, putty and paint to match with the existing surface including taking down existing unserviceable MCB DB of any description complete all as specified and directed by Engineer-in-Charge. Note: MCCB / MCBs shall be measured and paid separately. Make : Standard / Indo Asian / L&T / Havells
Supply and fix in replacement of MCCB 125A, 25KA, 4 Pole with fixed thermal magnetic release including taking down existing unserviceable MCCB of any description complete all as specified and directed by Engineer-in-Charge. Make : Standard / Indo Asian / L&T / Havells
Supply and fix in replacement of MCCB 160A, 25KA, 4 Pole with fixed thermal magnetic release including taking down existing unserviceable MCCB of any description complete all as specified and directed by Engineer-in-Charge. Make : Standard / Indo Asian / L&T / Havells
Taking down of existing unserviceable plug and socket board of any description and making good the disturbed surfaces to match with the existing surfaces with cement plaster / putty / distemper complete all as directed by Engineer -in - Charge.
Supply and fixing of modular MCB protected plug and socket board in sheet steel enclosure with 25A rated mini MCB and 25A rated 3 pin plug, 240 V, 50 Hz complete including cutting the wall surfaces for flush mounting of socket board complete all as specified and directed by Engineer-in-Charge. Make : Standard / Indo Asian / L&T / Havells
Taking down of existing unserviceable MCBs of any description complete all as directed by Engineer -in - Charge.
Supply and fix in replacement of MCB 6 - 32A, 10 KA, single Pole, 'C' curve, 240 V, 50 Hz including taking down existing unserviceable MCB of any description complete all as specified and directed by Engineer-in-Charge. Make : Standard / Indo Asian / L&T / Havells
M&L for earthing complete with galvanized iron earth plate electrode 600mm x 600mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 meters deep below ground level) with top edge of the plate not less than 1.5 meters below normal ground level connecting to GI wire 4 mm dia as earthing lead by means of bolts, nuts, check nuts and washers of galvanized iron or steel and earth wire protected by 15mm dia GI pipe medium grade and connected to distribution board/earthing test point all as shown in electrical plate No. 3 of SSR Part-I(2009) and testing on completion complete all as specified and directed. Note :- The unit rate quoted shall also include for excavation, earth work in any type of soil, plain cement concrete 1:3:6 mix, Type C1 pit, 40mm thick RCC 1:2:4 mix type B1 cover reinforced with 8mm dia TMT bras @ 150mm C/C both ways, GI funnel with watering pipe, wire mesh, protection pipe, earth wire up to 7.50m long complete in addition to item No. 1(a) to (e) of preamble (Notes) under sub heading earthing, specified in SSR Part II.
Supply, install and testing of evaporative desert cooler having nominal air flow capacity of 3000 Cum per hour with metallic body made out of 23 SWG GI sheet along with front grill and three side shutters with cooling pads etc and body fitted with heavy duty fan motor, copper wound, 1/7 HP, 1360/1400 RPM, three speed control, single phase, 230V, 50Hz with 450mm fan blades and 18 Watt submersible pump complete with float valve, PVC distribution pipe, control switch complete suitable for desert cooler including connecting cord PVC insulated and PVC sheathed copper conductor cable 3 core, 1.5 sqmm confirming to IS:694 up to 2.50 meters long fitted with plug top 3 pin, 6 Amps ISI marked complete all as specified and directed by Engineer-in-Charge. Make of Cooler Kit & Pump : Crompton / Khaitan / Marathon Electric Make of Wire : Havells / Polycab / KEI / Gloster Make of Plug Top: Anchor / Glodmedal / SSK / Havells / GM
M&L for Point wiring with 1.5 Sqmm FRLS insulated, unsheathed, multistranded, 1100 Volts grade copper conductor cable single core conforming to IS:694 along with one run of 1.5 Sqmm FRLS insulated copper conductor cable green in colour for continuous earthing drawn through and including medium grade rigid PVC conduit conforming to IS:9537 (Pt-III) and its all accessories/junction boxes/ inspection covers etc of suitable size but not less than 20mm(OD), concealed in wall/ floor etc including provision of pressed steel terminal box of thickness not less than 18 SWG, 60 mm deep with earth dolly of suitable size concealed in wall and covered with 3 mm thick phenolic laminated hylam sheet fixed with brass screws for mounting switches, sockets, fan regulator, etc. complete all as specified and directed by Engineer-in-Charge for One 6A socket point controlled by one switch on independent board Make: Conduit-AKG/ Atul/ Kalinga/Modi/Precision and Wire - Havells/ Polycab/ Finolex / KEI / Gloster. Note:- Quoted rate shall deemed to include the cost of cutting chases on wall/floor for concealed conduit wiring and making good with cement plaster, putty and paint to match with the existing surface.
Supply and fix switch piano flush type 6 Amps, one way, 240V, 50Hz complete all as specified and directed. Make: Havells(Reo) / Goldmedal/ SSK /GM
Supply and fix socket 6 Amps, 2-in-1 flush type universal 240V, 50Hz complete all as specified and directed. Make: Havells(Reo) / Goldmedal/ SSK /GM
Supply, installation, testing and commissioning of air cooled split type Air conditioner of 1.5 TR capacity comprising of one indoor and one outdoor unit, wall mounted type, comprise of copper pipe heat exchangers, non CFC refrigerant, electric driven, 230 volts AC, single Phase, 50 Hz, having either Five Star rating or inverter technology with three star, with and incl inlet / outlet copper pipe for refrigerant between indoor & outdoor unit and flexible copper wire of suitable size as recommended by manufacturer, complete all as directed. Make : Mitsubishi Heavy Industries / O General / Daikin. Note : The cost of making hole / opening for passing of inlet / outlet copper pipes and electrical cord and making good of surface as original by plastering / applying putty / whitewash / colour / distemper etc is included in quoted rate and no extra payment will be made to contractor in this effect.
Supply, installation, testing and commissioning of air cooled split type Air conditioner of 2.0 TR capacity comprising of one indoor and one outdoor unit, wall mounted type, comprise of copper pipe heat exchangers, non CFC refrigerant, electric driven, 230 volts AC, single Phase, 50 Hz, having either Five Star rating or inverter technology with three star, with and incl inlet / outlet copper pipe for refrigerant between indoor & outdoor unit and flexible copper wire of suitable size as recommended by manufacturer, complete all as directed. Make : Mitsubishi Heavy Industries / O General / Daikin. Note : The cost of making hole / opening for passing of inlet / outlet copper pipes and electrical cord and making good of surface as original by plastering / applying putty / whitewash / colour / distemper etc is included in quoted rate and no extra payment will be made to contractor in this effect.
Supply and fixing of wall mounted type voltage stabilizer 5 KVA, Copper Wound, Single Phase suitable for input voltage range 130 V to 280 V and output voltage stabilized to 220 V ± 10% with high voltage cut-off and thermal overload protection complete with smart digital display suitable for split ACs, complete all as specified and directed. Make : V-Guard / Volina / Aplab / Automatic Electric
Supply and fixin of wall mounted type voltage stabilizer 4 KVA, Copper Wound, Single Phase suitable for input voltage range 130 V to 280 V and output voltage stabilized to 220 V ± 10% with high voltage cut-off and thermal overload protection complete with smart digital display suitable for split ACs, complete all as specified and directed. Make : V-Guard / Volina / Aplab / Automatic Electric
Supply, laying/fixing, jointing and testing of Galvanized Iron (GI) pipe Medium grade with all necessary fittings such as sockets, bends, tees, elbows, unions, nipples etc laid in trenches / fixed to walls with suitable clamps as per site requirement complete all as specified and directed by Engineer-in-Charge for the following sizes:- Make : TATA / Jindal / Prakash Surya / BST
20mm dia (bore)
25mm dia (bore)
40mm dia (bore)
Supply and fix MCB distribution board, SPN, 4 way in sheet steel powder painted enclosure double door type with minimum IP 43 degree of protection with built in copper bus bar, neutral link and earth link complete including cutting the wall surfaces for flush mounting of DB and making good with cement plaster, putty and paint to match with the existing surface complete all as specified and directed by Engineer-in-Charge. Note: MCBs shall be measured and paid separately. Make : Standard / Indo Asian / L&T / Havells
Supply and fix MCB 40A, 10 KA, SPN, 'C' curve, 240 V, 50 Hz complete all as specified and directed by Engineer-in-Charge. Make : Standard / Indo Asian / L&T / Havells
Supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty cable with XLPE insulated stranded aluminium conductor served with an inner sheathing of PVC tape armoured with galvanized steel wire or strip and overall PVC sheathed, 16 sq. mm nominal cross section, 2 core as per IS 7098(Part 1) including connecting on LT OH line / LT panel /DB with suitable lugs, glands, binding wire etc complete all as specified and directed. Make: Polycab / Gloster / Universal / Havells / KEI
Supply and connect PVC Insulated and PVC Sheathed Industrial 3 Core Flat Submersible Cable with Bare Bunched Copper Conductor 2.5 sqmm for Submersible Pump Motors with Voltage Grade 1100 Volts as per IS:694/2010 complete all as specified and directed. Make : Havells / Polycab / Universal / Gloster / Finolex
Supply and fix Single Phase Direct Online (DOL) Submersible Pump Controllers panel suitable for open well submersible pump set of capacity 2HP with wideband coil, Overload relay, Ammeter/voltmeter, Push buttons and indication lamps for ON & OFF complete fixing on wall / MS structure with suitable clamps, nuts, bolts & washers including connecting all incoming and outgoing cables and testing for satisfactory performance complete all as specified and directed by Engineer-in-Charge. Make : L&T / C&S / Havells
Supply, installation and testing of Horizontal Monoblock Openwell Submersible Pump Set 1.5 KW / 2.0 HP, electric driven, AC single phase, 230 Volts, 50 HZ, suitable for 240 LPM discharge at a head of 22 Meter complete with Cast Iron Impeller, Cast Iron Delivery Casing, Stainless Steel (SS 410) Shaft, Stainless Steel Motor Body, Cast Iron Mounting Casing and Cast Iron NDE cover etc complete including connecting all water pipe lines and electric connections complete all as specified and directed by Engineer-in-Charge. Make : Kirloskar / Texmo / Crompton / KSB
Supply and fix Brass Non Return Valve (NRV) of size 40mm dia (bore) complete all as specified and directed by Engineer-in-Charge. Make: Zoloto / Sant / Leader / Gem
Supply and fix forged brass ball valve of size 40mm NB with screwed female ends complete all as directed. Make : Leader / Zoloto / Sant / Gem
Supply and fix forged brass ball valve of size 20mm NB with screwed female ends complete all as directed. Make : Leader / Zoloto / Sant / Gem
Supply and erection of Hot dip galvanized tapered octagonal pole of height 7.0 meters in single or double section having top dia 70mm and bottom dia 130mm made up of 3mm thick sheet and welded with a base plate of size 200mm x 200mm x 12mm thick and provided with 1000mm long four arm bracket with 15 degree of angle for mounting street light fitting complete with provision of 04 Nos of ‘J’ type foundation bolts of size not less than 20mm dia, 600mm long embedded in PCC foundation concrete as per manufacturer’s recommendation including necessary earth work, RFR etc complete. A door should be provided at a height of 500mm from the base plate for accommodating and including provision of TPN aluminium bus bar system suitable for connecting up to 2 core, 16 sqmm aluminium cable and 01 No. of 6A SP MCB for street light protection inside the pole shaft including provision of 3 core, 2.50 sqmm PVC insulated PVC sheathed copper conductor cable 1100 volts grade confirming to IS:694 from pole junction box to street light fitting drawn through inside of pole and each light fitting shall connected through cable connectors . Radium reflector band / strips of 5cm wide in Green (02 Nos) & White (01 No.) colour shall be provided at a height of 1.25mtr from base plate. Numbering of pole shall be done in black colour on yellow background at suitable place on the pole complete as directed by Engineer-in-Charge. Note: (i) Excavation, Earth Work, RFR etc and RCC shallow foundation as per manufacturer's design shall deemed to be included in quoted rate and nothing extra shall be paid on this account. (ii) Complete detailed drawing of pole and its foundation drawing as per manufacturer's recommendations shall be submitted and got approved from GE before procurement. Make : Bajaj / Philips / Utkarsh
Supply and fix 90 Watt LED street light fitting made up of Pressure die-cast aluminium alloy housing with toughened glass, IP66 protection and impact resistance of IK07 and individual high power LEDs with secondary optics having system lumen efficacy ≥100 lm/W, Inbuilt potted electronic LED driver with APFC (SMPS based constant current supply), lower THD, Open Circuit protection, Over Voltage protection, Surge Voltage protection & other safety test as per IS 15885 Part-2/Sec 13 and BIS complying complete all as specified and directed. Make: Bajaj / Philips / Wipro / Havells
Supply, installation & testing of Water Cooler, storage capacity 120 Liters and normal cooling capacity 60 Liters per hour with fully stainless steel body with 02 Nos brass chromium plated cold faucets, with R-134A ecofriendly refrigerant, suitable for operation on 230V, 50 Hz, single phase AC supply complete all as specified and directed. Make : Usha / Bluestar / Voltas /Carrier
Supply, connect & testing of automatic voltage stabilizer for low and high voltage cut-off, single phase, AC, 50 HZ, 4 Amps rating, suitable for input voltage range 135V - 280V for Water Cooler complete all as specified and directed by Engineer-in-Charge. Make: V-Guard / Volina / Microtek /Sinettrac / Aplab / Power ware
M&L for Tube, 'medium grade' galvanized, with all fitting of size 15mm bore and fixed complete to walls and ceilings or laid in floors complete all as specified and directed. Make : Tata / Jindal / Zenith / Prakash Surya / BST
Supply and fix angle valve, cast copper alloy, chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule of size 15mm bore dia complete all as specified and directed by Engineer-in-Charge. Make : Soma / Leader / Zoloto / PRAYAG / KINGSTON / Marc / Gem / Sieco.
Supply and fix Pedestal Fan, 450mm sweep with minimum 03 Nos of aerodynamically designed and balanced blades to deliver 100 m3/min of air, complete with fan guard, oscillating type, adjustable upward and downward tilt mechanism, ON/OFF and three speed motor control switch thermal overload protection device, single phase, 230 volts, 50 Hz complete all as specified and directed by Engineer-in-Charge. Make : Havells / Crompton / Orient / Usha / Bajaj
Supply, installation & testing of Electric Water Heater storage type, vertical, 25 Liters capacity, minimum 3 Star rated, with heating element, PUF insulation, multifunction safety valve, adjustable knob for temperature setting and mild steel inner tank and outer body suitable for operating on 230V, 50 Hz, single phase AC supply including hot & cold water PVC connections and mounting on wall with suitable size & No. of anchor bolts complete all as specified and directed. Make : Racold/ Venus / Usha / Bajaj
Supply and fix Bib tap, cast copper alloy, chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule of size 15mm bore dia complete all as specified and directed by Engineer-in-Charge. Make : Soma / Leader / Zoloto / PRAYAG / KINGSTON / Marc / Gem / Sieco.
M/S Kumar Contractors
FTH Traders
ADARSH ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .