| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.9 LAccepted-AOC | L1 | Accepted-AOC Being Lowest | |
| 2 | L2₹34.6 L+₹5.5 L (18.7%)Rejected-Finance WZ 143 A 7A S 4 43 GALI NO 2 OLD MAHAVIR NAGAR NEW DELHI 110018 | WEST DELHI | DELHI | 110018 | L2 | Rejected-Finance Not Being Lowest | |
| 3 | L3₹39.6 L+₹10.5 L (35.9%)Rejected-Finance | L3 | Rejected-Finance Not Being Lowest | |
| 4 | L4₹39.9 L+₹10.8 L (36.9%)Rejected-Finance | L4 | Rejected-Finance Not Being Lowest | |
| 5 | L5₹41.6 L+₹12.4 L (42.7%)Rejected-Finance 216 UGF RAM VIHAR ANAND VIHAR DELHI 110092 | SHAHDARA | DELHI | 110092 | L5 | Rejected-Finance Not Being Lowest |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
2 Jan 2023, 6:00 pmClosed
GE (Central) Delhi Cantt-10
GE (Central) Delhi Cantt-10
EXTERNAL PERIODICAL SERVICES ALONGWITH REPAIR/ REPLACEMENT OF OLD WIRING WITH COPPER WIRING AND OTHER MISC WORKS AT 1 AHQ SIGNAL ENCLAVE OLD/ NEW APS SANJAY VIHAR 500 I SIGNAL COY ARJAN VIHAR NEW PRATAP CHOWK OFFRS MD ACCN AND OTHER ADJOINING
2022_MES_553623_1
GE/C-58/2022-23
Open Tender
Civil Works
Item Rate
180 days
GE (Central) Delhi Cantt-10
As per NIT
9 documents required · 9 mandatory
₹500
Yes
GE (Central) Delhi Cantt-10
₹90,000
Yes
14 Jan 2023
22 Sept 2022
4 Jan 2023
22 Sept 2022
2 Jan 2023
6 Oct 2022
22 Sept 2022 - 6 Oct 2022
Amount
M&L for preparation of old decoreated external wall / Ceiling surface of existing treatment by scrapping with TruCare Wall Sander : L-01/H-01 (having mechanical vacuum mechanism) having RPM not less than 1500, sanding pad of 80 Grit having dia of 7”/9” to make the surface free from dust, loose paint etc. or equivalent makes viz Xpress sanding machine having suction vaccum bag or by manual scrapping tools where mechanical removal is not possible up to 5 storey bldg complete all as specified and all as directed by Engr- in-charge. Note :- 1. Stage for prepration of surfaces shall be got approved from GE before applying the finishes. 2. Material shall be procured from manufacturer and work shall be got executed through authorised applicator. Note rate quoted up to G+5 bldg including scaffolding
M&L for preparation of old decoreated/undecoreated external wall / Ceiling applying two coats of weather proofing exterior acrylic emulsion paint by spray gun/ spray machine incl one coat of primer up to 5 storey bldg complete all as specified and all as directed by Engr- in-charge. Note :- 1. Stage for prepration of surfaces shall be got approved from GE before applying the finishes. 2. Material shall be procured from manufacturer and work shall be got executed through authorised applicator. Note rate quoted up to G+5 bldg including scaffolding
M&L for preparation of old decoreated/undecoreated external wall / Ceiling applying one coats of weather proofing exterior acrylic emulsion paint by spray gun/ spray machine up to 5 storey bldg complete all as specified and all as directed by Engr- in-charge. Note :- 1. Stage for prepration of surfaces shall be got approved from GE before applying the finishes. 2. Material shall be procured from manufacturer and work shall be got executed through authorised applicator. Note rate quoted up to G+8 bldg including scaffolding
Taking down cement plaster on brick walls, or stone walls / ceilings etc including raking out joints, hacking for key, scrubbing down with water etc complete all as specified. Note rate quoted up to G+5 bldg including scaffolding
M&L for 15mm thick ready mix cement plaster with bulk density 1.4 to 1.70KG per ltr water ration 17 to 19% by weight with compressive str as per IS 4031 part-VI applied as per the manufactore instr incl necesaery cement screed and prepartion of surface to received ready mix plaster up to G+5 bldg including scaffolding . complete all as specified and directed by engineer-in-charge complete all as specified and directed compound complete.
M&L for 5mm thick ready mix cement plaster ceiling / chhaja with bulk density 1.4 to 1.70KG per ltr water ration 17 to 19% by weight with compressive str as per IS 4031 part-VI applied as per the manufactore instr incl necesaery cement screed and prepartion of surface to received ready mix plaster up to 10m height. complete all as specified and directed by engineer-in-charge complete all as specified and directed compound complete
M&L for preparation of newly plaster surface of wall / Ceiling surface applying two coats of weather proofing exterior acrylic emulsion paint by spray gun/ spray machine incl one coat of primer up to 5 storey bldg including scaffolding complete all as specified and all as directed by Engr- in-charge. Note :- 1. Stage for prepration of surfaces shall be got approved from GE before applying the finishes. 2. Material shall be procured from manufacturer and work shall be got executed through authorised applicator. Note rate quoted up to G+5 bldg including scaffolding
M&L for preparation of newly plaster surface of wall / Ceiling applying two coats of cement base paint by spray gun/ spray machine up to 5 storey bldg complete all as specified and all as directed by Engr- in-charge. Note :- 1. Stage for prepration of surfaces shall be got approved from GE before applying the finishes. 2. Material shall be procured from manufacturer and work shall be got executed through authorised applicator. Note rate quoted up to G+5 bldg including scaffolding
M&L for preparation of newly plaster surface of wall / Ceiling surface applying one coats of Oil bound distemper by spray gun/ spray machine up to 10m height complete all as specified and all as directed by Engr- in-charge. Note :- 1. Stage for prepration of surfaces shall be got approved from GE before applying the finishes. 2. Material shall be procured from manufacturer and work shall be got executed through authorised applicator. Note rate quoted up to G+5 bldg including scaffolding
M&L for preparation of newly plaster surface of Wall / Ceiling surface applying two coats of white wash by spray gun/ spray machine up to 10m height complete all as specified and all as directed by Engr- in-charge. Note :- 1. Stage for prepration of surfaces shall be got approved from GE before applying the finishes. 2. Material shall be procured from manufacturer and work shall be got executed through authorised applicator. Note rate quoted up to G+8 bldg including scaffolding
M&L for preparation of old decoreated/undecoreated external wall / Ceiling applying two coats of cement base paint by spray gun/ spray machine up to 5 storey bldg complete all as specified and all as directed by Engr- in-charge. Note :- 1. Stage for prepration of surfaces shall be got approved from GE before applying the finishes. 2. Material shall be procured from manufacturer and work shall be got executed through authorised applicator. Note rate quoted up to G+5 bldg including scaffolding
M&L for preparation of old decoreated/undecoreated external wall / Ceiling applying one coats of cement base paint by spray gun/ spray machine up to 5 storey bldg complete all as specified and all as directed by Engr- in-charge. Note :- 1. Stage for prepration of surfaces shall be got approved from GE before applying the finishes. 2. Material shall be procured from manufacturer and work shall be got executed through authorised applicator. Note rate quoted up to G+5 bldg including scaffolding
M&L for chipping out spilled and loose concrete cover and derusting steel reinforement of concrete column, beam, slab, chajjas, parapets and the like as directed upto 25 to 35mm thick roughening and cleaning concrete surface with steel wire brushes, washed with water and allowed to dry including derusting steel wire reinforecement, providing fabric MS wire mesh 75 x 75 x 2mm as reinforcement to concrete surface applying adhesive/admixture over steel mesh and providing 25mm average thickness guiniting mix using one part of OPC 53 grade and two part of gaggar sand mixed with adhesive/admixture @ pressure of 2.5 to 3.00kg/Sqcm by guiniting machine and surface finished even and fair including necessary padding, shuttering/scaffolding, formwork (guniting work to be carried out upto 10 metre height) complete as directed at site Note :- (a) After placing the additional reinforecement all concrete surfaces shall be throughly scrubbed with wire brushes, washed with water and allow to dry, apply chemistic polycretes admixture @ 2.25 kg by weight of cement all as per manufacturers instruction. (b) when polymix concreting in taking condition,guiniting is done with polycrete admixture @ 2% by weight of cement all as per manufacturers instructions (polycrete admixture shall be procured from chemical adhesive Pvt Ltd Co or their authorised dealer). (c) Cost of the above aspect shall be deemed to be included in the quoted rate of the respective item and nothing extra shall be paid on any account. Note rate quoted up to G+5 bldg including scaffolding
M&L for preparation of old decoreated/undecoreated external wall / Ceiling applying two coats of Oil bound distemper by spray gun/ spray machine up to 5 storey bldg complete all as specified and all as directed by Engr- in-charge. Note :- 1. Stage for prepration of surfaces shall be got approved from GE before applying the finishes. 2. Material shall be procured from manufacturer and work shall be got executed through authorised applicator. Note rate quoted up to G+5 bldg including scaffolding
M&L for Preparation of old painted surfaces of wood surfaces of any description over 10 Cm width or girth by applying sand paper etc.for proper preparation and applying two coat of synthetic enamel paint to give an even and smooth surface having no sign of brush marks complete all as specified and directed. Note rate quoted up to G+5 bldg including scaffolding
M&L for Preparation of old painted surfaces of steel of any description over 10 Cm width or girth by applying sand paper etc.for proper preparation and applying one coat of synthetic enamel paint to give an even and smooth surface having no sign of brush marks all as specified and directed complete all as specified and directed. Note rate quoted up to G+5 bldg including scaffolding
M & L for removal of plant growth by injection with chemical glyphosphate solution (4 % concentration) @ 20 ml or till refuse by cutting or injection in stem of plants or roots at 30 mm. The area shall then be sprayed with solution 25 ml glyphosphate (4% conc) diluted with 1 ltr of water. The size of block shall be of 2 Qtrs on each floor and vary in number of floors. All roots of plants shall be removed completely and making good the disturbed surface and painted with cement base or acrylic paint all as specified and directed by Engr-in-charge
Taking down care fully copper/aluminium point wiring from wooden batten or conduits (light, fan, socket or power) complete excluding fittings such as switches, sockets, ceiling roses, pendents, regulators, light fittings any type etc to be measured seperately) and making good disturbed surfaces of walls, floors etc complete all as specified and directed by Engineer in charge.
M & L for Point wiring complete with 1.5 sqmm single core PVC insulated FRLS cable 1100 volts grade with multi stranded copper conductor drawn through Existing metallic/ non metallic conduit, including provision of 1.5 sqmm PVC insulated copper cable FRLS as earth continuty and fabricated branded modular metal flush box / M S Steel terminal boxes, concealed in walls with suitable modular inner and outer plate / 3 mm thick laminated top sheet cover for housing switches , socket out let and fan regulators etc , all as specified and as directed for the followings:-
(a) One light/fan point controlled by one way switch
(b) One bell / buzzer point controlled by one bell push
(c) One light point controlled by two Nos two way switches
(d) One 3 pin 5 Amps socket outlet point controlled by one way switch on independent board.
(e) One 3 pin 5 Amps socket outlet point controlled by one way switch on same board
All as per item No 19 but point wiring with 4 Sqmm single core copper cable and earth continuity wire with 2.5 Sqmm single core stranded copper cable for one three pin 15 socket outlet point on independent board complete all as specified and directed by Engineer in charge.
M & L for Point wiring complete with 1.5 sqmm single core PVC insulated FRLS cable 1100 volts grade with multi stranded copper conductor drawn through and including non-metalic rigid PVC conduit medium grade ISI Marked and all conduit accessories concealed in wall/ceiling/fixed to roof/truss/columns etc and including provision of 1.5 sqmm PVC insulated copper cable FRLS as earth continuty, fabricated branded modular metal flush box / M S steel terminal boxes, concealed in walls with suitable modular inner and outer plate / 3 mm thick laminated top sheet cover for housing switches , socket out let and fan regulators etc , all as specified and as directed for the followings:- complete all as specified and directed by Engineer in charge.
(a) One light/Exh fan point controlled by one way switch
(b) One bell / buzzer point controlled by one bell push
(c) One light point controlled by two Nos two way switches
(c) One 3 pin 5 Amps socket outlet point controlled by one way switch on independent board.
(d) One 3 pin 5 Amps socket outlet point controlled by one way switch on same board
All as per item No 21 but point wiring with 4 Sqmm single core copper cable and earth continuity wire with 2.5 Sqmm single core stranded copper cable for one three pin 15 socket outlet point on independent board complete.
Taking down old unserviceable MS Steel terminal boxes from wall and supply and fixing fabricated branded modular metal flush box 1 module / 2 module concealed in walls with suitable modular inner and outer plate for housing switches , socket out let and fan regulators etc including make good of disturbed surface complete all as specified and directed by Engineer in charge. Note-Switch,socket, regulator will be paid separately.
Taking down old unserviceable MS Steel terminal boxes from wall and supply and fixing fabricated branded modular metal flush box 3 module / 4 module concealed in walls with suitable modular inner and outer plate for housing switches , socket out let and fan regulators etc including make good of disturbed surface complete all as specified and directed by Engineer in charge. Note-Switch,socket, regulator will be paid separately.
Taking down old unserviceable MS Steel terminal boxes from wall and supply and fixing fabricated branded modular metal flush box 6 module concealed in walls with suitable modular inner and outer plate for housing switches , socket out let and fan regulators etc. including make good of disturbed surface complete all as specified and directed by Engineer in charge. Note-Switch,socket, regulator will be paid separately.
Taking down old unserviceable MS Steel terminal boxes from wall and supply and fixing fabricated branded modular metal flush box 8 module concealed in walls with suitable modular inner and outer plate for housing switches , socket out let and fan regulators etc including make good of disturbed surface complete all as specified and directed by Engineer in charge. Note-Switch,socket, regulator will be paid separately.
M&L in replacement switch Modular type 6 Amps 1 Way,1 module, 230V AC complete all as specified.
M&L in replacement Modular socket outlet 2/3 pin 6 Amp socket 2 module complete all as specified.
M&L in replacement switch modular type 6 amp SP two way, 1 module complete all as specified.
M&L in replacement Modular Bell push button SP with indicator 6 Amps, 1 module 230V AC complete all as specified.
M&L in replacement switch Modular type 16 Amps 1Way, 1 module with modular plate light marking 230V AC complete.
M&L in replacement Modular socket outlet 2/3 pin 6/16 Amp universal socket 2 module complete.
M&L in replacement modular stepped type electronic fan regulator 120W, 2 module complete .
M&L in replacement switch piano flush button type single pole one way 6 Amps complete all as specified.
M&L in replacement switch piano flush button type single pole 16 Amps complete all as specified.
M&L in replacement socket outlet, 2 in 1, 3 pin 6 and 16 Amp single pole complete all as specified.
M&L in replacement socket outlet 6 Amp flush button type complete all as specified.
M&L in replacement regulator electronic switch/socket type 5 steps suitable for 1200/1400 mm sweep 230 volts complete.
M&L in replacement bell electric (dingdong) 230 volt, SP all complete all as specified and directed by Engineer in charge .
M/L in replacement insulated body, angle holder (metal ring) with back plate complete all as specified and directed.
S&F ceiling rose surface PVC 65x50 mm type with three terminals complete all as specified and directed .
M&L in replacement sheet metal enclosure, single pole and neutral with a two pin and earth plug and socket 240 Volts grade 10Amps complete with one single pole MCB 'C' series 10/20 A capacity complete all as specified.
Supply and fix in replacement LED batten luminaire surface mounted, 4 feet system wattage of 22 Watts, > 2400 systems lumen outputwith lifetime of 50000 burning hours with 70% of its initial lumen maintained. CRI>80, Power Factor > 0.95, THD< 10%, colour temperature - 6500K, surge protection 2.5KV in CM, IP-20 protected, meets LED IS specifications, Class - 1, Short circuit and over circuit protection, voltage range - 150 to 270 Volts AC, temperature range 0 to 50 DegreeC and including connecting up with PVC sheathed 1.5 sqmm 3 core copper conductor flexible wire from ceiling rose to fitting fixed complete all as specified and directed.
Supply and fix in replacement LED batten luminaire surface mounted 2 feet system wattage of 10 watts and not less than 1000 lm with life time of 50000 burning hours with 70% of its initial lumen maintained. CRI > 80, power factor > 0.95, THD < 10%, color temperature > 6500 K , surge protection 2.5 KV in CM IP- 20 protected meets LED IS specifications, voltage range - 150 to 270 volts AC, temperature range 0 to 50 Degree C, system efficiancy at luminarie level ≥100 Lumens/watt and including connecting up with PVC sheathed 1.5 sqmm 3 core copper conductor flexible wire fixed complete all as specified and directed.
Supply and fix in replacement LED 9/10 watts bulkhead fitting with powder coated die cast aluminium housing with glass/ non yellowing polycarbonate cover, IP65 Protection, System level efficacy of the Luminary is > 90 lm/W with a life class of 50,000 burning hours at L70 criteria, Power Factor >0.95, driver with Voltage range 150-270V, Temperature range 0 to 50 Deg, Driver efficiency >85%, THD<10%, CRI>80, Color Temperature-6000K, Surge protection of 2.5 KV, including connecting up with necessary PVC sheathed 3 core 1.5Sqmm copper conductor flexible wire fixed complete all as specified and directed.
S&F in replacement of decorative type wall mounted luminaire (Comet) with unbreakable poly carbonate materials suitable for 1x14 watt LED bulb B22 base complete all as specified and directed by Engineer in charge .
Supply and fix surface ceiling mounted, LED down light fitting 12 watts with die cast aluminium housing and system wattage of 12W, system efficacy at luminary level ≥ 80 Lumens/watt, 50000 burning hours, 6500K color temperature with CRI >80, Power Factor > 0.90, Driver should meet IEC compliant for safety with multi stage high Isolate CC-CV operated driver with voltage variation range - 150 to 270 Volts AC, and surge protection of 2.5 KV, and including connecting up with PVC sheathed 3 core 1.5Sqmm copper conductor flexible wire fixed complete all as specified and directed. .
Supply and Fix in replacement 35 W High efficient LED Street light fitting with pressure die cast LM6 Aluminum housing and has lenses specially designed for Street Lighting with polycarbonate cover. System level efficacy of the Luminarie is 100lm/W with a life class of 50,000 burning hours at L70. The color temperature is around 6500 K with a color rendering index of 70. The luminaire is IP:66 protected with IK05 impact resistance. It has an electronic driver complaint to IEC safety standards with a power factor>.0.9, voltage variation range 120-270V, THD<20%, High and low protection along with a surge protection of 4 KV including provision of 25 mm dia GI light grade pipe1.5 meter length bend to shape and necessary clamps etc for fixing the light fittings on pole fixed complete as specified and directed. .
Supply and Fixing LED bulb 9 watts, 900 lumens output, 6500K suitable for B-22 base complete all as specified.
Supply and Fixing LED bulb 14 watts, 900 lumens output, 6500K suitable for B-22 base complete all as specified.
S&F in repair Sub main wiring with two runs of 4 Sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable with one run of 4 sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable as earth continuity conductor, drawn through and including 20 mm dia non metallic rigid PVC conduit and conduit accessories on surface/ concealed in walls complete all as specified and directed. Note: Three runs of 6 sqmm cable shall be measured as one RM.
Supply and fix in repair Sub main wiring complete with two runs of 4 Sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable with one run of 4 sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable as earth continuity conductor, drawn through existing metallic/ non metallic conduit in walls all as specified and as directed. Note: Three runs of 4 sqmm cable shall be measured as one RM.
S&F in repair Sub main wiring with two runs of 6 Sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable with one run of 6 sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable as earth continuity conductor, drawn through and including 20 mm dia non metallic rigid PVC conduit and conduit accessories on surface/ concealed in walls complete all as specified and directed. Note: Three runs of 6 sqmm cable shall be measured as one RM.
S&F in repair Sub main wiring with two runs of 10 Sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable with one run of 10 sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable as earth continuity conductor, drawn through and including 20 mm dia non metallic rigid PVC conduit and conduit accessories on surface/ concealed in walls complete all as specified and directed. Note: Three runs of 6 sqmm cable shall be measured as one RM.
Supply and fix in replacement MCB DB SPN 12 way Horizontal, IP - 43 Protection double door 240 V AC 50Hz with for MCB SPN as incomer and DP/SP MCBs as out going with tinned copper bus bar ,neutral link earth link complete all as directed by Engineer -in- Charge.
Supply and fix in replacement MCB DB SPN 8 way Horizontal, IP - 43 Protection double door 240 V AC 50Hz with for MCB SPN as incomer and DP/SP MCBs as out going with tinned copper bus bar ,neutral link earth link complete all as directed by Engineer -in- Charge.
S&F MCB in replacement DB SPN 02 way, single door 240 V AC 50Hz , with 10 Amps MCB SPN as incomer / out going complete.
Supply and fix in repair MCB DP 6-32 Amps 240 volts 10 KA 50 HZ 'C' curve complete.
Supply and fix in repair MCB DP 40 to 63 Amps 240 volts 10 KA 50 HZ 'C' curve complete.
Supply and fix in repair MCB SP 6-32 Amps 240 volts 10 KA 50 HZ 'C' curve complete.
Supply and fix in repair MCCB 250 Amps, FP 415 volts 25 KA 50 HZ with thermal magnetic setting .
Supply and fixing Ventilating Fan 250 mm sweep, 1250 RPM, non metallic resin body, single phase 240 volts AC 50 Hz and connecting up complete including louvers and provision of copper cable 3 core of size 0.5 sqmm for connection from ceiling rose to fan complete all as specified and as directed.
S&F wall mounted fan 400 mm sweep, aerodynamic designed, air delivery ≥ 70 CMM, thermal over load protected motor, 3 blade white colour, 230 volts, 50 Hz, 1420 RPM with 90 degree oscillation and having speed & oscillation control by two pull cords system complete all as specified
M & L for in replacement only single core PVC insulated cable 1.5 Sqmm FRLS 1100 Volts with copper multi stranded conductor and drawing in existing concealed conduits, all as specified and directed by Engr-in-Charge.
M & L in replacement for only single core PVC insulated cable 2.5 Sqmm FRLS 1100 Volts with copper multi stranded conductor and drawing in existing concealed conduits , all as specified and directed by Engr-in-Charge.
S&F SS braided pipe of 12 mm ((internal) suitable for hot/cold water, 60 cm long with brass nuts and rubber washers complete.
S&F in replacement heating element of 1.5 KW any type with nut bolt washer complete all as directed.
S&F thermostat suitable for 25/35/50 ltr capacity of geyser complete all as directed.
Supply only replacement of capacitor 3.15 Mfd, 240 V complete all as specified and directed.
Supply only replacement of capacitor 1.5 Mfd, 240 V complete all as specified and directed.
supply only hole fastner madeup of MS 6" long with complete nut bolt all as specified.
Schedule of Credit
M/S Sunil Steel Works
ANSH VANSH CONSTRUCTION COMPANY
M/S Blues Developers Pvt. ltd
V M CONSTRUCTION
VED PRAKASH ARORA
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .