Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹36.3 LAccepted-AOC | L1 | Accepted-AOC lowest | |
| 2 | L2₹37.0 L+₹5,395 (0.15%)Rejected-Finance | L2 | Rejected-Finance RATE HIGH | |
| 3 | L3₹37.4 L+₹41,827 (1.13%)Rejected-Finance | L3 | Rejected-Finance RATE HIGH | |
| 4 | L4₹37.7 L+₹76,785 (2.08%)Rejected-Finance | L4 | Rejected-Finance RATE HIGH | |
| 5 | L5₹39.9 L+₹3.0 L (8.11%)Rejected-Finance 401 SHRINAT HEIGHTS HADAPSAR ROAD SURVEY NO 97 MANJARI BK HAVELI PUNE 412307 | PUNE | MAHARASHTRA | 412307 | L5 | Rejected-Finance RATE HIGH |
| Sl No | Description | Qty | Unit | M/s.BAJRANG CONSTRUCTION L6 | Santosh Pandurang Pise L3 | K S CHADHA AND SONS L4 | GS Associates L5 | MONA ASSOCIATES L2 | PAL CONSTRUCTION L1 | J D Contruction L7 | KANT INFRA L8 |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Scooping & taking out sludge, sullage and foreign materials from septic tank, soak wells of any description & depth including removing & re-fixing of accessories and appliances required for safe disposal of sludge, sullage and foreign materials either by carrying the same in covered van / trolley outside defence land and it should be disposed off at such place which is not determinate to public health, complete all as specified and directed.
Note :- Net depth of sludge shall be measured for payment purpose after bailing out water and the cost of bailing out water shall be deemed to be included in unit quoted rates. | 15 | Cum | 500 ₹7,500 | 95 ₹1,425 Lowest | 900 ₹13,500 | 500 ₹7,500 | 150 ₹2,250 | 123 ₹1,845 | 2,000 ₹30,000 | 450 ₹6,750 |
| 2.00 | S&F in repairs of following bore reinforced concrete pipes, class NP2, laid and jointed complete with rubber ring joints including taking down / dismantling of old unserviceable RCC / SWG or CPVC drain pipes and removing debris from site complete all as specified and directed by Engr-in-Charge :-
(a) 150 mm bore | 460 | RM | 500 ₹2,30,000 | 275 ₹1,26,500 Lowest | 350 ₹1,61,000 | 450 ₹2,07,000 | 310 ₹1,42,600 | 400 ₹1,84,000 | 480 ₹2,20,800 | 423 ₹1,94,580 |
| 2.10 | (b) 200 mm bore | 30 | RM | 900 ₹27,000 | 312 ₹9,360 Lowest | 600 ₹18,000 | 650 ₹19,500 | 510 ₹15,300 | 500 ₹15,000 | 700 ₹21,000 | 549 ₹16,470 |
| 2.20 | (c.) 300mm dia
Note for item nos. 2 to 2.20 :- Laying of sewage line work is to carried out in running sewage water therefore, temporary diversion /plugged of existing sewage line & bailing out of sewage water is the responsibility of contractor and the cost for the same provisions are to be deemed to be included in unit quoted rates. | 30 | RM | 1,000 ₹30,000 | 455 ₹13,650 Lowest | 700 ₹21,000 | 950 ₹28,500 | 850 ₹25,500 | 600 ₹18,000 | 800 ₹24,000 | 801 ₹24,030 |
| 3.00 | Excavation in trenches not exc 1.5m wide and n.exc 1.5m in depth for foundations, manholes etc and getting out in any type of soil, complete all as specified and directed. | 235 | Cum | 150 ₹35,250 | 210 ₹49,350 | 149 ₹35,015 | 325 ₹76,375 | 210 ₹49,350 | 100 ₹23,500 Lowest | 170 ₹39,950 | 225 ₹52,875 |
| 4.00 | Excavation in trenches not exc 1.5m wide and exc. 1.5m but n.exc. 3.0m in depth for foundations, manholes etc and getting out in any type of soil, complete all as specified and directed. | 5 | Cum | 500 ₹2,500 | 245 ₹1,225 Lowest | 1,199 ₹5,995 | 800 ₹4,000 | 300 ₹1,500 | 250 ₹1,250 | 5,000 ₹25,000 | 351 ₹1,755 |
| 5.00 | M&L for concrete bed 1:4:8 type D-2 as in drain pipes including packing under, and haunching against the side of pipes after they are laid and tested, 150mm bore of pipe, complete all as specified and directed. | 420 | RM | 75 ₹31,500 | 105 ₹44,100 | 70 ₹29,400 | 120 ₹50,400 | 50 ₹21,000 Lowest | 70 ₹29,400 | 180 ₹75,600 | 153 ₹64,260 |
| 6.00 | M&L for concrete bed 1:4:8 type D-2 as in drain pipes including packing under, and haunching against the side of pipes after they are laid and tested, 200mm bore of pipe, complete all as specified and directed. | 25 | RM | 250 ₹6,250 | 125 ₹3,125 | 70 ₹1,750 | 220 ₹5,500 | 60 ₹1,500 Lowest | 75 ₹1,875 | 250 ₹6,250 | 207 ₹5,175 |
| 7.00 | M&L for concrete bed 1:4:8 type D-2 as in drain pipes including packing under, and haunching against the side of pipes after they are laid and tested, 300mm bore of pipe, complete all as specified and directed. | 25 | RM | 350 ₹8,750 | 155 ₹3,875 | 70 ₹1,750 Lowest | 350 ₹8,750 | 70 ₹1,750 Lowest | 89 ₹2,225 | 250 ₹6,250 | 306 ₹7,650 |
| 8.00 | Returning, filling in any type of soil, including spreading, levelling, watering and well ramming in layers n.exc 25cm thick, complete all as specified and directed. | 145 | Cum | 55 ₹7,975 | 55 ₹7,975 | 90 ₹13,050 | 120 ₹17,400 | 100 ₹14,500 | 35 ₹5,075 Lowest | 200 ₹29,000 | 108 ₹15,660 |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
6 Nov 2025, 6:00 pmClosed
GE SOUTH PUNE
NO 1 GEN BHAGAT MARG PUNE 40
8745 REPAIR REPLACEMENT AND CLEANING OF MANHOLE SEWAGE LINE SEPTIC TANK SOAKAGE WELL AND CONNECTED MISC BR WORK IN MD ACCN AND OTM ACCN OF MINTSD SAIBABA COMPLEX 4 RMC NO 1 LINE NEPIER ROAD CARRIAPPA ENCLAVE UNDER AGE BR II OF GE SOUTH PUNE
2025_MES_735336_1
8745 GE SOUTH PUNE
Open Tender
Civil Works
Item Rate
270 days
GE SOUTH PUNE
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE SOUTH PUNE
₹90,000
Yes
9 Jan 2026
15 Oct 2025
8 Nov 2025
15 Oct 2025
6 Nov 2025
29 Oct 2025
Amount
Scooping & taking out sludge, sullage and foreign materials from septic tank, soak wells of any description & depth including removing & re-fixing of accessories and appliances required for safe disposal of sludge, sullage and foreign materials either by carrying the same in covered van / trolley outside defence land and it should be disposed off at such place which is not determinate to public health, complete all as specified and directed. Note :- Net depth of sludge shall be measured for payment purpose after bailing out water and the cost of bailing out water shall be deemed to be included in unit quoted rates.
S&F in repairs of following bore reinforced concrete pipes, class NP2, laid and jointed complete with rubber ring joints including taking down / dismantling of old unserviceable RCC / SWG or CPVC drain pipes and removing debris from site complete all as specified and directed by Engr-in-Charge :- (a) 150 mm bore
(b) 200 mm bore
(c.) 300mm dia Note for item nos. 2 to 2.20 :- Laying of sewage line work is to carried out in running sewage water therefore, temporary diversion /plugged of existing sewage line & bailing out of sewage water is the responsibility of contractor and the cost for the same provisions are to be deemed to be included in unit quoted rates.
Excavation in trenches not exc 1.5m wide and n.exc 1.5m in depth for foundations, manholes etc and getting out in any type of soil, complete all as specified and directed.
Excavation in trenches not exc 1.5m wide and exc. 1.5m but n.exc. 3.0m in depth for foundations, manholes etc and getting out in any type of soil, complete all as specified and directed.
M&L for concrete bed 1:4:8 type D-2 as in drain pipes including packing under, and haunching against the side of pipes after they are laid and tested, 150mm bore of pipe, complete all as specified and directed.
M&L for concrete bed 1:4:8 type D-2 as in drain pipes including packing under, and haunching against the side of pipes after they are laid and tested, 200mm bore of pipe, complete all as specified and directed.
M&L for concrete bed 1:4:8 type D-2 as in drain pipes including packing under, and haunching against the side of pipes after they are laid and tested, 300mm bore of pipe, complete all as specified and directed.
Returning, filling in any type of soil, including spreading, levelling, watering and well ramming in layers n.exc 25cm thick, complete all as specified and directed.
Removing excavated materials (Soil) exceeding 50m but n. exc. 250m and depositing where directed at a level n. exc. 1.50m above the starting point, complete all as specified and directed.
S&F in repairs PVC (SWR) gully trap 125x110mm, setting and jointing to waste pipe pipe with solvent cement, complete all as specified and directed.
Attending day to day complaints by deploying 02 Nos of safaiwala for 08 hrs working for cleaning of all blockage of any type of sewage line i.e. branch sewer line, main sewer line etc, manholes of any size and depth, in any situation by way of cleaning / desludging by manually or mechanically or by way of any other suitable means including foreign materials as well as rodding (full through) of sewer lines and between the blocked manholes where required and ordered by Engineer-in-charge and keeping the sewage line all time functional, cleaning traps, water closet, soil waste/vent pipe, gully traps etc complete upto final drop out let into septic tanks and soakage well (working in foul condition with taking precautionary measures with necessary equipment as required or applicable at site complete all as directed by Engr-in-Charge. Note:-(i) The sludge (wet or dry) removed from the manholes and sewage line shall be removed to outside MD land complete all as directed by Engr-in-Charge. (ii) Each Job shall contain various complaints of sewage/cleaning done by 02 Nos of safaiwala for 08 hrs working (per day basis) complete received by the office each day. (iii) Complaint shall be completed on same day (handed over till 1600 hrs) (iv) If Safaiwala not attended complaint within time frame mentioned above, 50% shall be deducted from completed by him per day (v) The contractor shall be responsible for maintain daily job completed by the safaiwala deputed by him in the subject work and obtain the signature of I/C complaint cell / Engr-in-charge daily at 1700 hrs on all working days.
Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B1 smooth finished, and reforming benching as required for the following dia of pipe, complete all as specified and directed:- (a) 150mm bore
(b) 300 mm Bore
M&L for PCC 1:4:8 type D-2 using 40 mm graded stone aggregate as in foundation filling / mass concrete, including demolition of existing unserviceable PCC complete all as specified and directed.
M&L for brick work with fly ash Bricks straight or curved on plan exec 6 mtr mean radius with modular bricks in CM 1: 6 incluidng dismantling of brick / PCC block walling masonary, built in cement mortar including all quoins, arches, pillars etc., complete all as specified and directed.
S&F in repairs vitreous china wash down water closet pan, 'Pedestal' white including fixing bolts etc with and including PVC seat cover white with flat bottom including mild steel CP or aluminium anodised hinges devices etc complete all as specified and directed.
S & F in repairs vitreous china squatting Pan "Orissa" pattern of size 580 mm X 440 mm white with integral foot rests (Excluding flushing cistern and flush pipe) with and including connection to trap & flush pipe, anti-syphonic pipe & provision of cement concrete bedding and making good to floor as per existing complete all as specified and directed.
S & F in repairs 10 ltr capacity PVC valveless, syphonic action type, flushing cistern, low level, white, including flush pipe 32 mm dia, complete all as specified and directed.
Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete using extra cement including forms, moulds mitred / stopped end, complete all as specified and directed.
M & L for 15mm thick rendering in cement mortar 1:4 on fair faces of PCC block walling / brick masonry work or concrete surfaces, finish the surfaces even and smooth with out using extra cement complete all as specified and as directed.
M & L for 15mm thick rendering in cement mortar 1:6 on fair faces of PCC block walling / brick masonry work or concrete surfaces, finish the surfaces even and smooth with out using extra cement complete all as specified and as directed.
M & L for 15mm thick rendering in cement mortar 1:4 on fair faces of PCC block walling / brick masonry work or concrete surfaces, finish the surfaces even and smooth with out using extra cement including taking down of old plaster from brick or block walling complete all as specified and as directed.
S&F 75mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to wall or laid under floors / in earth, including dismantling of breaking drain pipes, complete all as specified and directed.
S&F 110 mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to wall or laid under floors / in earth, including dismantling of breaking drain pipes, complete all as specified and directed.
All as per item no. 23 but fixing only 75mm dia pipes, complete all as specified and directed.
All as per item no. 24 but fixing only 110mm dia pipes, complete all as specified and directed.
S&F in repairs PVC (SWR), 75mm bore junction with access door, single (Single Tee), equal or unequal, complete all as specified & directed.
S&F in repairs PVC (SWR), 110mm bore junction with access door, single (Single Tee), equal or unequal, complete all as specified & directed.
S&F in repairs 110 mm bore PVC (SWR) plain bends, any radius, complete all as specified and directed.
S&F in repairs 75 mm bore PVC (SWR) plain bends, any radius, complete all as specified and directed.
S&F in repairs PVC (SWR) bends with oval access door of 110 mm bore, complete all as specified and directed.
S&F in repairs PVC (SWR) bends with oval access door of 75 mm bore, complete all as specified and directed.
S&F in repairs PVC SWR Branch piece single (Single Y) equal or unequal 110mm dia with door access, complete all as specified and directed.
S&F in repairs PVC SWR Branch piece single (Single Y) equal or unequal 75 mm dia with door access, complete all as specified and directed.
S&F PVC (SWR) vent cowl 110mm bore, complete all as specified & directed.
S&F PVC (SWR) vent cowl 75mm bore, complete all as specified & directed.
M&L for precast RCC, 1:2:4 type B-0, using 12.5 mm size graded crushed stone aggregate as in manhole cover of size 700x700x50mm thick including with angle iron frame made out of 50x50x5mm size angle iron, including reinforcement with 10 mm dia TMT bars in both way, spacing 150 mm c/c, binding with and including mild steel wire, including groove and hook arrangement for lifting and placing in position complete all as specified and directed
M&L for precast RCC, 1:2:4 type B-0, using 12.5 mm size graded crushed stone aggregate as in manhole cover of size 700x1000x50mm thick including with angle iron frame made out of 50x50x6mm size angle iron, including reinforcement with 10 mm dia TMT bars in both way, spacing 150 mm c/c, binding with and including mild steel wire, including groove and hook arrangement for lifting and placing in position complete all as specified and directed
M&L for precast RCC, 1:2:4 type B-0, using 12.5 mm size graded crushed stone aggregate as in manhole cover of size 700x1200x50mm thick including with angle iron frame made out of 50x50x6mm size angle iron, including reinforcement with 10 mm dia TMT bars in both way, spacing 150 mm c/c, binding with and including mild steel wire, including groove and hook arrangement for lifting and placing in position complete all as specified and directed
M&L for PCC 1:3:6 type C-2, (using 40mm graded stone aggregate) of 75mm thick, laid in alternate bays including finishing the surfaces even and smooth using extra cement including demolition of existing unserviceable PCC complete all as specified and as directed
M&L for providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in foot path, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould of required colour & pattern laid over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand complete all as specified and as directed by Engr-in-Charge.
M&L for PCC (1:2:4) type B-1 using 20 mm stone graded aggregate as in coping including weathering and throating including necessary form work etc. complete all as specified and directed
S&F 150mm dia HDPE DWC (Double wall corrugated) pipe, class SN8, ante rodent, laid and jointed including with all fittings & fixtures, including demolition of breaking up RCC, SWG or CPVC drain pipe etc complete all as specified and directed by Engr-in-Charge. Note:- (a). Laying of sewage line work has to be carried out in running sewage water & temporary diversion /plugged of existing sewage line & bailing of sewage water is the responsibility of contractor and the rate for the same shall be deemed to be included in unit quoted rates.
S&F 200mm dia HDPE DWC (Double wall corrugated) pipe, class SN8, ante rodent, laid and jointed including with all fittings & fixtures, including demolition of breaking up RCC, SWG or CPVC drain pipe etc complete all as specified and directed by Engr-in-Charge. Note:- Laying of sewage line work has to be carried out in running sewage water & temporary diversion /plugged of existing sewage line & bailing of sewage water is the responsibility of contractor and the rate for the same shall be deemed to be included in unit quoted rates.
S&F 300mm dia HDPE DWC (Double wall corrugated) pipe, class SN16, ante rodent, laid and jointed including with all fittings & fixtures, including demolition of breaking up RCC, SWG or CPVC drain pipe etc complete all as specified and directed by Engr-in-Charge. Note:- Laying of sewage line work has to be carried out in running sewage water & temporary diversion /plugged of existing sewage line & bailing of sewage water is the responsibility of contractor and the rate for the same shall be deemed to be included in unit quoted rates.
Demolition of cement concrete in existing sunken portion including floor tiles, removing of old unserviceable traps of any description and applying rendering in CM 1:3 in sunken & vertical portion and applying two coats of Dr. Fixit water proofing chemical by brushing as per manufacturer's instructions and S&F 75mm or 110 mm PVC floor / Nahani trap with stainless steel grating including jointing to waste pipe fixed and filling of sunken potion by cement concrete type 1:2:4 type B-1 including M&L for providing floor tiling as per existing type & specification complete all as specified and as directed by Engr-in-Charge. Note:- (i). The contractor shall responsible for any leakage / seepage from sunken slab after carried out above mentioned job. If any, leakage seepage observed within defect liability period, he will be rectified the same at his own cost and no extra payment on this account shall be entertained by the Department. (ii). Area of sunken floor shall not be exceeded 4.0 Sqm in each Job.
S&F in repairs 15mm bore GI pipe "medium grade" including with all fittings & fixtures, fixed to walls / ceiling or laid in floors in any position or location including taking down of old unserviceable pipe complete all as specifed and directed.
M&L for cutting chases, pinning in, concrete block / brick / stone walling & making good to facing where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels etc. and cutting chases for concealed water tubing and making good, cutting n. exc. 10 cm girth, complete all as specified and directed.
S&F in repairs vitreous china wash hand basin, white flat back of size 550x400mm including with PVC waste coupling 32mm and PVC waste pipe, CP angle cock 15mm bore, PVC connection 45cm long including CI brackets / fixing with fasteners etc complete all as specified and directed.
M&L for 75mm thick PCC 1:4:8 type D-2 (Using 40mm graded stone aggregate) as in sub base of floor, finished the surfaces fair & even to receive floor finishes including demolition of existing unserviceable PCC layer complete all as specified and directed.
M&L for precast coloured, chequrred cement concrete tiles, glossy finish of size 300 x 300mm x 25mm thick, conforming to IS-1237 (2006) set jointed and pointed in neat cement slurry in floor laid over and including 20mm thick screed bed in CM (1:6) including demolition of existing floor tiles & bedding layer complete all as specified and directed
S & F in repairs of 15 mm bore bib taps, chromium plated, fancy type, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule, complete all as specified and directed.
S & F in repairs of 15 mm bore two way bib taps, chromium plated, fancy type, cast copper alloy with crutch or butterfly handle, screwed down, with wall flange, complete all as specified and directed.
S&F in repairs stop valves / angular stop cock, cast copper alloy, chromium plated, fancy type, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions of 15mm bore, complete all as specified and directed.
S&F in repairs stop valves / angular stop cock, cast copper alloy, chromium plated, fancy type, concealed, long shank, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions of 15mm bore, complete all as specified and directed.
S&F in repairs CP Wall mixer 3-in-1 for mixing hot & cold water screwed down for iron pipe and fixed for 15mm bore of pipe complete all as specified and directed.
S&F in repairs shower rose, chromium plated brass, fancy type 125mm dia including shower arm with or without swivel any size, including fixing to steel pipe or union, complete all as specified and directed.
S & F in repairs CP health faucet (ABS Body) with 1.0 m long flexible cod complete all aspecified and directed.
S&F in repairs PVC connection pipe 600mm long as suitable with 2 Nos PTMT check nuts suitable for 15mm bore of pipe with washer, complete all as specified and directed.
S&F brass chromium plated tubular towel rail 20 mm dia D type, 60 cm long between flanges complete all as specified and as directed.
S & F in repairs Toilet paper holder with flat recessed type stainless steel complete all as specified and directed
S & F in repairs chromium plated soap dish fixed to plugs with chromium plated brass screws complete all as specified and directed.
S&F in repairs towel ring of CP fixed with and including chromium plated brass screws and wooden/plastic cleats complete all as specified and directed.
S& F in repair 5mm thick sheet glass corner shelf, 250mm radius including CP railing and CP brackets, complete all as specified and directed.
S&F ventilators / louvers with partially gauged shutter using 4 mm thick x10 cm width frosted glass strip with following aluminium powder coated sections confirming to JINDAL catalogue or of equivalent makes as mentioned in list of makes here-in-after with and including necessary rubber beading, cleats and locking arrangements, etc. complete all as specified and directed:- (a) SP-20048 (b) glazing clips-19352
Dismantling posts & struts (Steel or RCC), embeded in concrete, any section, including taking out embedded portion and making good disturbed ground, complete all as specified and directed.
Cleaning of manholes & sewage line of any description and size (wet or dry condition) by using high pressure water jetting machine including plugging of sewage line, removal of waste matter by pump and disposal of the same as directed, necessary arrangement for controlling of traffic etc. complete all as directed by Engr-in-Charge. Note: - (i) Measurement shall be taken from centre to centre of manholes for payment purpose. (ii) The contractor shall submit necessary documentary proof of Jetting machine vehicle viz RC, Drivers Licence copy, Vehicle Insurance copy etc. to Engr-in-Charge.
M&L for PCC 1:2:4 type B-1, (using 20mm graded stone aggregate) as in surface channels and drains, bed blocks and benching of manholes including all moulds and forms complete all as specified and directed.
S&F in repairs mild steel chromium plated grating (round) 125 mm dia fixed over floor / nahani trap (with hole OR without hole), complete all as specified and directed.
M&L for coloured glazed ceramic designed tiles in vertical surface 600x 300x 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match laid over and including 10 mm thick backing coat in CM 1:4 with and including triangular filleting on top edges in CM 1:4 including dismantling wall tiling including taking down backing coat, removing rubbish off the premises complete all as speicified and directed.
M&L for coloured glazed ceramic designed tiles in vertical surface 300x 200x 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match laid over and including 10 mm thick backing coat in CM 1:4 with and including triangular filleting on top edges in CM 1:4 including dismantling wall tiling including taking down backing coat, removing rubbish off the premises complete all as speicified and directed.
M&L for non-skid ceramic coloured tiles 7 to 8 mm thick area of each tiles exceeding 0.06 Sqm but not exceeding 0.11 as in floors, set and jointed in neat cement slurry and pointed in white or coloured cement to match including laid over and including 15 mm thick screed bed in CM 1:6 including taking down of old existing unserviceable tiles of any type including screed bed and removing of debries & dismantled materials and rubbish off the premises complete all as specified and as directed
Dismantaling fencing wire mesh, any type, complete all as specified and directed.
Supply only chain link MS galvanized fencing of any size & shape complete all as specified and directed
Fixing only chain link fencing including line wires any mesh size and type to any type of standards rails straining bolts including provision of binding wire etc. complete all as specified and directed
Supply and fixing mild steel work as in posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc. and similar work conforming to Fe 290 Gde E-165, complete all as specified and directed.
M&L for TMT bars up to 10 mm dia, cut to length, bent to shape required including cranking, bending spirally for hooping for column, hooking ends and binding with and including MS wire (annealed) not less than 0.9 mm dia complete all as specified and directed.
S&F in repairs galvanised, 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossing with and provision of galvanised mild steel wire, staples or steel pins, etc. as directed (each line wire to be measured), including taking down of old unserviceable barbed wire of any type complete all as specified and directed.
S&F framed work such as in hunge gate including pintal hinges, stops handmade sliding bolt grills, gratings, etc. with ends of bars shouldered and / or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; including ornamental and intricate design, walk ways; railings; framework of water tanks and similar work conforming to Fe.290. Gde-E-165, including dismantling of old existing steel / iron articles etc. complete all as specified and directed
M&L for framed work as in portions framed and hung as gates, including pintle hinges, stop, hand made sliding bolts etc. conforming to Fe 410-0 or Fe 310-0, including dismantling old existing steel work including doors, gates etc, complete all as specified and directed
M&L for two coats of synthetic enamel paint over a coat of red oxide primer on new steel surface of any description exc. 10 cm width or girth, including preparation of new steel surfaces, complete all as specified and directed.
S&F in repairs high density 40mm bore polythylene pipes (HDPE) of pressure rating 6 kg/cm² fixed complete to wall or in floors with necessary socket, elbow & bend etc complete fixed to wall or in floors etc complete all as specified and as directed.
MONA ASSOCIATES (BID ID -3469596)
Santosh Pandurang Pise (BID ID -3468285)
K S CHADHA AND SONS (BID ID -3473845)
GS Associates (BID ID -3468434)
M/s.BAJRANG CONSTRUCTION (BID ID -3468116)
J D Contruction (BID ID -3465880)
KANT INFRA (BID ID -3468768)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.60 MB
BOQ_823423.xls
BOQ • 0.75 MB
8745TD.pdf
Tender Documents • 0.94 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .