Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.0 LAccepted-AOC | L1 | Accepted-AOC being L1 | |
| 2 | L2₹23.8 L+₹1.2 L (5.35%)Rejected-Finance KHEMASULI P S KHARAGPUR LOCAL DIST PASCHIM MEDINIPUR WEST BENGAL | KHARAGPUR | PASCHIM MEDINIPUR | WEST BENGAL | L2 | Rejected-Finance Not being L1 | |
| 3 | L3₹24.1 L+₹1.5 L (6.41%)Rejected-Finance | L3 | Rejected-Finance Not being L1 | |
| 4 | L4₹24.8 L+₹2.2 L (9.83%)Rejected-Finance | L4 | Rejected-Finance Not being L1 | |
| 5 | L5₹26.5 L+₹3.9 L (17.2%)Rejected-Finance | L5 | Rejected-Finance Not being L1 |
Tender Value
Refer Docs
EMD Value
₹40,000
Closing Date
13 Oct 2020, 6:00 pmClosed
GE (AF) KALAIKUNDA
GE (AF) Kalaikunda PO Kalaikunda Air Field Dist Paschim Medinipore St West Bengal Pin 721303
REPAIR/MAINTENANCE OF INTERNAL ELECTRIFICATION WIRINGS INCLUDING ELECTRICAL FITTINGS AND FIXTURES IN CERTAIN MARRIED AND OTM ACCN OF DOMESTIC AREA AT AFS UNDER GE AF KALAIKUNDA
2020_MES_374593_2
8594/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
AF STN KALAIKUNDA
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE (AF) KALAIKUNDA
₹40,000
Yes
22 Mar 2021
22 Sept 2020
14 Oct 2020
22 Sept 2020
13 Oct 2020
28 Sept 2020
Amount
Taking down carefully copper/ aluminium point wiring (light, fan, socket or power) complete including fittings such as switches, ceiling roses, pendent, regulators, sockets, light fittings etc, removing materials from site and making good disturbed surfaces of walls, floors etc., complete all as specified and directed.
Taking down carefully copper/ aluminium submain wirings of any size (2 runs single core including earth continuity) complete including PVC casing capping/ PVC conduit/Steel Conduit with fittings etc, removing materials from site and making good disturbed surfaces of walls, floors etc., complete all as specified and directed.
Materials and Labour for point wiring with 1.50 Sq. mm (nominal area) FRLSH PVC insulated and unsheathed, multi stranded copper conductor cable 1100 Volts grade, single core, laid in and including 25mm wide double locking type PVC casing and capping complete with all fittings and accessories, fixed to walls/ceiling, including sunk type pressed steel terminal boxes 60 mm deep, conforming to IS-5133 (Part-I) with 3 mm thick plastic laminated sheet cover (ISI Marked) for mounting switches/ regulator /bell push etc and including 1.50 Sq. mm (nominal area) FRLHS PVC insulated and unsheathed multi stranded copper conductor cable 1100 Volts grade, single core, earth continuity conductor connected to common earth dolly for :-Note : Wiring to be done as per approved IE rules colour code. (ii) The cable length from switch board to fittings/ fixture should be of 3 x 1.5 Sqmm cable and the length of cable in the case should be of max 3 x 20 mtr from the switch board. Beyond this length it should not be considered as point wiring and the whole length to be measured as sub main wiring..
One light/fan point controlled by one switch
One bell point controlled by one switch
One 3 Pin 5 Amps socket outlet independent
One light point controlled by two Nos of 2 Way Switches.
One 3 Pin 5 Amps socket outlet on the same board with other switch
Materials and Labour for point wiring with 2.50 Sq. mm (nominal area) FRLHS PVC insulated and unsheathed, multi stranded copper conductor cable 1100 Volts grade, single core, laid in and including PVC casing and capping complete with all fittings and accessories, fixed to walls/ceiling, including sunk type pressed steel terminal boxes 60 mm deep, conforming to IS-5133 (Part-I) with 3 mm thick plastic laminated sheet top cover (ISI Marked) for mounting switch socket outlet etc and including 2.50 Sq. mm (nominal area) FRLHS PVC insulated and unsheathed multi stranded copper conductor cable 1100 Volts grade, single core, earth continuity conductor connected to common earth dolly for one 3 Pin 15 Amps socket out let independent, complete all as specified and directed.(i)Wiring to be done as per aproved colour code. (ii) Sub circuit from MCB DB to Switch board should be of 3 x 2.50 Sqmm Cable and the length of cable in this case should be of max 3 x 15 Mtr from the distribution board. Beyond this length it shall not be considered as point wiring and the whole length to be measured in sub main wiring.
Materials and Labour for point wiring with 4.00 Sq. mm (nominal area) FRLHS PVC insulated and unsheathed, multi stranded copper conductor cable 1100 Volts grade, single core, laid in and including PVC casing and capping complete with all fittings and accessories, fixed to walls/ceiling, including sunk type pressed steel terminal boxes 60 mm deep, conforming to IS-5133 (Part-I) with 3 mm thick plastic laminated sheet top cover (ISI Marked) for mounting switch socket outlet etc and including 2.50 Sq. mm (nominal area) FRLHS PVC insulated and unsheathed multi stranded copper conductor cable 1100 Volts grade, single core, earth continuity conductor connected to common earth dolly for one 3 Pin 15 Amps socket out let independent, complete all as specified and directed.Note : (i)Wiring to be done as per approved IE rules colour code. (ii) Sub circuit from MCB DB to Switch board should be of 3 x 4.00 Sqmm Cable and the length of cable in this case should be of max 3 x 15 Mtr from the distribution board. Beyond this length it shall not be considered as point wiring and the whole length to be measured in sub main wiring.
Materials and Labour for point wiring with 1.50 Sq. mm (nominal area) FRLSH PVC insulated and unsheathed, multi stranded copper conductor cable 1100 Volts grade, single core, laid in and including 25mm wide double locking type PVC casing and capping complete with all fittings and accessories, fixed to walls/ceiling, including PVC box for mounting switches/ regulator /bell push etc and including 1.50 Sq. mm (nominal area) FRLHS PVC insulated and unsheathed multi stranded copper conductor cable 1100 Volts grade, single core, earth continuity conductor connected to common earth dolly for :-Note : Wiring to be done as per approved colour code IE rules. (ii) Sub circuit from MCB DB to Switch board should be of 3 x1.5 Sqmm Cable and the length of cable in this case should be of max 3 x 15 Mtr from the distribution board. Beyond this length it shall not be considered as point wiring and the whole length to be measured in sub main wiring.
One 3 Pin 5 Amps socket outlet independent
All as per item. 06 herein before but wiring with 2.5 Sq mm FRLSH mutistranded copper conductor cable for 5/15 amp switch socket combination on independent board and with 2.5 Sqmm, FRLSH insulated multi-stranded single core earth wire for earth continuity, connected to common earth dolly complete all as specified and directed. .Note : Wiring to be done as per aproved colour code. (ii) Sub circuit from MCB DB to Switch board should be of 3 x 2.5 Sqmm Cable and the length of cable in this case should be of max 3 x 15 Mtr from the distribution board. Beyond this length it shall not be considered as point wiring and the whole length to be measured in sub main wiring. Note : Wiring to be done as per aproved colour code.
M & L for concealed point wiring with and including single core PVC insulated, unsheathed flexible conductor FR-LSH cables 1.5 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through & including medium mechanical stresses class PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20 mm nominal size including all accessories/ fittings/ junction boxes/ inspection cover etc. ISI marked and sunk terminal boxes flush galvanised metal boxes suitable for fixing with 1.5 sqmm copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable as continuous earth wire connected to metallic body at one end and common earth dolly to other end complete all as specified and as directed. (Note: (i) The chases in the wall shall be cut with elect cutter and rates of the same will deemed to be included in quoated rates (ii) The disturbed surfaces of wall shall be made good with cement plaster 1:4 including matching the surfaces with as per existing finishes and to the entire satisfaction of Engineer in Charge):- (iii)Wiring to be done as per approved colour code in IE rule. (iv) The cable length from switch board to fittings/ fixture should be of 3 x 1.5 Sqmm cable and the length of cable in the case should be of max 3 x 20 mtr from the switch board. Beyond this length it should not be considered as point wiring and the whole length to be measured as sub main wiring
One light/fan point controlled by one switch
One 3 Pin 5 Amps socket outlet independent
One 3 Pin 5 Amps socket outlet on the same board with other switch
One bell buzzer point controlled by one switch
Materials and Labour for concealed type point wiring with 4.00 Sq. mm (nominal area) FRLHS as per IS 694: 2010, ISI marked PVC insulated and unsheathed, multi stranded copper conductor cable 1100 Volts grade, single core, drawn in and including medium mechanical stresses class PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20 mm nominal size including all accessories/ fittings/ junction boxes/ inspection cover etc including sunk type pressed steel terminal boxes 60 mm deep, conforming to IS-5133 (Part-I) with 3 mm thick plastic laminated sheet top cover (ISI Marked) for mounting switch socket outlet etc and including 4.00 Sq. mm (nominal area) FRLHS PVC insulated and unsheathed multi stranded copper conductor cable 1100 Volts grade, single core, earth continuity conductor connected to common earth dolly for one 3 Pin 15 Amps socket out let independent, complete all as specified and directed.(Note: (i) The chases in the wall shall be cut with elect cutter and rates of the same will deemed to be included in quoated rates (ii) The disturbed surfaces of wall shall be made good with cement plaster 1:4 including matching the surfaces with as per existing finishes and to the entire satisfaction of Engineer in Charge):- (iii)Wiring to be done as per approved colour code in IE rule. (iv) The cable length from switch board to fittings/ fixture should be of 3 x 4.00 Sqmm cable and the length of cable in the case should be of max 3 x 20 mtr from the switch board. Beyond this length it should not be considered as point wiring and the whole length to be measured as sub main wiring
Materials and Labour for concealed type point wiring with 2.5 Sq. mm (nominal area) FRLHS as per IS 694: 2010, ISI marked PVC insulated and unsheathed, multi stranded copper conductor cable 1100 Volts grade, single core, drawn in and including medium mechanical stresses class PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20 mm nominal size including all accessories/ fittings/ junction boxes/ inspection cover etc including sunk type pressed steel terminal boxes 60 mm deep, conforming to IS-5133 (Part-I) with 3 mm thick plastic laminated sheet top cover (ISI Marked) for mounting switch socket outlet etc and including 2.50 Sq. mm (nominal area) FRLHS PVC insulated and unsheathed multi stranded copper conductor cable 1100 Volts grade, single core, earth continuity conductor connected to common earth dolly for one 3 Pin 15 Amps socket out let independent, complete all as specified and directed.(Note: (i) The chases in the wall shall be cut with elect cutter and rates of the same will deemed to be included in quoated rates (ii) The disturbed surfaces of wall shall be made good with cement plaster 1:4 including matching the surfaces with as per existing finishes and to the entire satisfaction of Engineer in Charge):- (iii)Wiring to be done as per approved colour code in IE rule. (iv) The cable length from switch board to fittings/ fixture should be of 3 x 2.5 Sqmm cable and the length of cable in the case should be of max 3 x 20 mtr from the switch board. Beyond this length it should not be considered as point wiring and the whole length to be measured as sub main wiring
M & L for concealed point wiring with and including single core PVC insulated, unsheathed flexible conductor FR-LSH cables 1.5 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through existing old serviceable concealed PVC conduit retrived from item no.01 here -in before including all accessories/ fittings/ junction boxes/ inspection cover etc. ISI marked and sunk terminal boxes flush galvanised metal boxes suitable for fixing with 1.5 sqmm copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable as continuous earth wire connected to metallic body at one end and common earth dolly to other end complete all as specified and as directed. (Note: (i) The chases in the wall shall be cut with elect cutter and rates of the same will deemed to be included in quoated rates (ii) The disturbed surfaces of wall shall be made good with cement plaster 1:4 including matching the surfaces with as per existing finishes and to the entire satisfaction of Engineer in Charge):- (iii)Wiring to be done as per approved colour code in IE rule. (iv) The cable length from switch board to fittings/ fixture should be of 3 x 1.5 Sqmm cable and the length of cable in the case should be of max 3 x 20 mtr from the switch board. Beyond this length it should not be considered as point wiring and the whole length to be measured as sub main wiring-
One light/fan point controlled by one switch
One 3 Pin 5 Amps socket outlet independent
One bell buzzer point controlled by one switch
All as per item.10 herein before but wiring with 2.5 Sq mm FRLSH mutistranded copper conductor cable for 5/15 amp switch socket combination on independent board and with 2.5 Sqmm, FRLSH insulated multi-stranded single core earth wire for earth continuity, connected to common earth dolly complete all as specified and directed. .
All as per item.10 herein before but wiring with 4.0 Sq mm FRLSH mutistranded copper conductor cable for 5/15 amp switch socket combination on independent board and with 4.0 Sqmm, FRLSH insulated multi-stranded single core earth wire for earth continuity, connected to common earth dolly complete all as specified and directed. .
Supply and fix sub main wiring complete with and including two Nos single core PVC insulated, unsheathed flexible conductor FR-LSH cables 4 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through and including medium mechanical stresses class PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 25 mm nominal size including all accessories and fixed on walls and 4.00 sqmm one No single core copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable for earthing and connected to common earth dolly complete all as specified and directed by Engineer-in-charge. Note - Two runs of 4 sqmm cable, one run of 4 sqmm cable and one run of conduit will be measured and paid as one unit length. (Note: Cost of cutting chase and making good deemed to be included in quoated rates)
Supply and fix sub main wiring complete with and including two Nos single core PVC insulated, unsheathed flexible conductor FR-LSH cables 6 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through and including medium mechanical stresses class PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 25 mm nominal size including all accessories and fixed on walls and 6.00 sqmm one No single core copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable for earthing and connected to common earth dolly complete all as specified and directed by Engineer-in-charge. Note - Two runs of 6 sqmm cable, one run of 6 sqmm cable and one run of conduit will be measured and paid as one unit length. (Note: Cost of cutting chase and making good deemed to be included in quoated rates)
M&L for Sub main wiring with two runs of single core PVC insulated unsheathed cable 1100 volts grade, multistranded copper conductor FRLS cable of 4.0 Sqmm as per IS 694: 2010, ISI marked (with colour code), drawn in but including PVC casing caping not less than 25 mm width, ISI marked, double locking type including one run of PVC insulated unsheathed, multistranded copper conductor FRLS cable of 4.0 Sqmm (Green colour) as contineous earth conductor cable connected to earth dolly in surface complete all as specified and directed .
M&L for Sub main wiring with two runs of single core PVC insulated unsheathed cable 1100 volts grade, multistranded copper conductor FRLS cable of 6.0 Sqmm as per IS 694: 2010, ISI marked (with colour code), drawn in but including PVC casing caping not less than 25 mm width, ISI marked, double locking type including one run of PVC insulated unsheathed, multistranded copper conductor FRLS cable of 6.0 Sqmm (Green colour) as contineous earth conductor cable connected to earth dolly in surface/ recess complete all as specified and directed
M&L for Sub main wiring with two runs of single core PVC insulated unsheathed cable 1100 volts grade, multistranded copper conductor FRLS cable of 10.0 Sqmm as per IS 694: 2010, ISI marked (with colour code), drawn in but including PVC casing caping not less than 38 mm width ISI marked double locking type including one including one run of PVC insulated unsheathed, multistranded copper conductor FRLS cable of 10.0 Sqmm (Green colour) as contineous earth conductor cable connected to earth dolly in surface/ recess complete all as specified and directed
M&L for Sub main wiring with Four single core (3 phase) PVC insulated unsheathed cable 1100 volts grade, 6.0 Sqmm sizeas per IS 694: 2010, ISI marked with multistranded copper conductor, FRLS cable drawn in but including PVC casing capping not less than 38 mm ISI marked including all accessories of casing caping as approved by EIC including two run of PVC insulated unsheathed 6.0 Sqmm cable with multistranded copper conductor green PVC insulated as contineous earth conductor cable connected to earth dolly complete ( 4 x 6.0 sqmm + 2 x 6.0 Sqmm earth wire) complete all as specified and directed
M&L for Sub main wiring with Four single core (3 phase) PVC insulated unsheathed cable 1100 volts grade, 10 Sqmm size with multistranded copper conductor, FRLS cable drawn in but including PVC casing capping not less than 40 mm ISI marked including all accessories of casing caping as approved by EIC including two run of PVC insulated unsheathed 10.0 Sqmm cable with multistranded copper conductor green PVC insulated as contineous earth conductor cable connected to earth dolly complete ( 4 x 10.0 sqmm + 2 x 10.0 Sqmm earth wire) . complete all as specified and directed
Supply and fix switch piano, flush button, single pole, one way, 5 Amps, complete all as specified and directed.
Supply and fix switch piano, flush button, single pole, two way, 5 Amps, complete all as specified and directed.
Supply and fix Polycarbonate angular lamp holder with back plate, suitable for batten fittings complete all as specified and directed.
Supply and Fix,switch socket combination 2 in 1, 5A,flush type, complete all as specified and directed.
Supply and Fix,switch socket combination 3 pin 5A/16A, 5 in 1 flush type, complete all as specified and directed.
Supply and Fix stepped type electronic fan regulator, flush type, on existing phenolic laminated sheet etc. as required , complete all as specified and directed.
Supply and fix Ceiling Rose, three terminal, PVC/ Polycarbonate insulated body, complete all as specified and directed.
S&F, Buzzer, Ding Dong AC. 230 volts, single poleomplete all as specified and directed.
Supply and fix ,bell push, flush type, single pole, 5 Amps, complete all as specified and directed.
Supply and Fix in repairs, Modular Switch, one way, 6 Amps, 1 Module, complete all as specified and directed.
Supply and Fix in repairs, Modular Switch, one way, 16 Amps, 1 Module, complete all as specified and directed.
Supply and Fix in repairs, Modular Bell Push, 6 Amps, 1 Module, complete all as specified and directed.
Supply and fixing in repair switch socket combination 5-in-1, 5A/15 Amps, 6 pin, 240 volts controlled by one switch, flush type including PVC mouting box complete all as specified and directed Make Anchor Penta Cat No. 39593 or equivalent make havells
S&F in repair modular switch socket combination 16A , 6 Pin combined -3 module including whole modular fittings and frame with new one as per existing complete all as specified and directed
S&F in repair modular socket 6A/16A 2/3 Pin combined -2 module including repairing/replacement of whole modular fittings and frame with new one as per existing fittings complete all as specified and directed
Supply and Fix in repairs, Modular Fan step regulator, 120W - 2 module,complete all as specified and directed.
Supply and Fix in repairs, Bell Ding Dong, AC 230 volts, single pole, complete all as specified and directed.
Supply and Fixing in repair Modular white cover plate with frame for 1 Module complete all as specified and directed
Supply and Fixing in repair Modular white cover plate with frame for 2 Module including complete all as specified and directed
Supply and Fixing in repair Modular white cover plate with frame for 4 Module including complete all as specified and directed .
Supply and Fixing in repair Modular white cover plate with frame for 6 Module including complete all as specified and directed .
Supply and Fixing in repair Modular white cover plate with frame for 8 Module including complete all as specified and directed
Supply and Fixing in repair Modular metal flush box of 1/2 module including including make good to match with existing surface complete all as specified and directed
Supply and Fixing in repair Modular metal flush box of 4 module ncluding make good to match with existing surface complete all as specified and directed
Supply and Fixing in repair Modular metal flush box of 6 module including make good to match with existing surface complete all as specified and directed
S&F in repairs PVC/ bakelite sheet 3mm thick ISI marked of size 13'' X 11'' inches including cutting of sheet for fixing switch / socket etc. (Make : Heylam or equivalent) complete all as specified and as directed.
S&F in repairs PVC/ bakelite sheet 3mm thick ISI marked of size 9'' X 11'' inches including cutting of sheet for fixing switch / socket etc. (Make : Heylam or equivalent) complete all as specified and as directed.
S&F in repairs PVC/ bakelite sheet 3mm thick ISI marked of size 5'' X 8'' inches including cutting of sheet for fixing switch / socket etc. (Make : Heylam or equivalent) complete all as specified and as directed.
S&F in repairs PVC/ bakelite sheet 3mm thick ISI marked of size 5'' X 5'' inches including cutting of sheet for fixing switch / socket etc. (Make : Heylam or equivalent) complete all as specified and as directed.
M&L for repairing distribution box(DB's) of any rating, any size by proper dressing of wirings,providing lugs, screw, nuts , cleaning of the burned surfaces etc, tightening of all the connections of incoming and outgoings from the MCB's/ DB, connecting Earthing connection to each earth dolly including fixing of DB cover by providing screws etc complete all as specified and directed by Engr-in-Charge.
S & F LED bulkhead light with pressure die-cast housing light fittings nominal power 12 watt LED of Make Osram; Everlight; Philips; Nicha; Cree; Samsung, LED wattage of minimum 1 watt each and Maximum 3 watt each, operational voltage of 170 volts to 270 volts. frequency of 50 Hz, lumen output of minimum 1100, lumen , , integrated electronic driver (SMP based constant current supply) with output short circuit protection and surge protection upto 3 KV, protection grade IP 65, CRI greater than 80%, ITHD below or less than 15%, CW available CCT of 6500K, power factor of minimum 0.95 polycarbonate housing with aluminium, life span of minimum 50000 working hours as per catalogue No. CENTURY - HWAR012C OR equivalent of CG/Philip/Wipro complete all as specified and as directed.
Supply and fixing earth continuity conductor or main earthing lead of 4 mm GI wire laid in pipe/ fixed to wall on batton or recess or chases or buried in ground or drawn in conduit / pipe or any other indicated situation for loop earthing etc including jointing by using suitable size lugs, GI nuts, bolts and washer complete and all as specified and directed .
S&F galvanised steel tubing light grade 15 mm dia for protection of GI wire fixed/ laid on floor/wall fixed with and including G I clamps complete all as specified and directed
S & F LED tube light fittings(T8 TYPE) with LED tube lamp nominal power 20 Watt, LED of Make Osram; Everlight; Philips; Nicha; Cree; Samsung, LED wattage of minimum 1 watt each and Maximum 3 watt each, operational voltage of 170 volts to 270 volts. frequency of 50 Hz, lumen output of minimum 2100Lumen efficacy of minimum 110 lumens per watt, integrated electronic driver (SMP based constant current supply) with output short circuit protection and surge protection upto 3 KV, protection grade IP 20, CRI greater than 80%, bema angle of 1200 clear, THD below or less than 15%, CW available CCT of 6500K, power factor of minimum 0.95 polycarbonate housing with aluminium, life span of minimum 50000 working hours as per Make :- Century (Batten Cat No.KCCF0200 box type batten suitable for 18/20 watt retofit LED tube single side connection type). LED lamp : Make : Century Cat No. TWPP020C (retrofit LED tube lamp 20 Watt, Single end connection) OR CROMPTON (Batten Cat No. IGP161LT8-16 box type batten suitable for 20 watt retofit LED tube ). LED lamp : Make : Crompton Cat No. LTT8-20 LED (retrofit LED tube lamp 20 Watt with AL Heat sink),) OR equivalent of CG/Philip/Wipro complete all as specified and as directed. Note : Make of batten and LED tube lamp shall be same make.
S & F in repair LED tube lamp nominal power 20 Watt, LED of Make Osram; Everlight; Philips; Nicha; Cree; Samsung, LED wattage of minimum 1 watt each and Maximum 3 watt each, operational voltage of 170 volts to 270 volts. frequency of 50 Hz, lumen output of minimum 2100Lumen efficacy of minimum 110 lumens per watt, integrated electronic driver (SMP based constant current supply) with output short circuit protection and surge protection upto 3 KV, protection grade IP 20, CRI greater than 80%, bema angle of 1200 clear, THD below or less than 15%, CW available CCT of 6500K, power factor of minimum 0.95 life span of minimum 50000 working hours as per Make :- Century . : Make : Century Cat No. TWPP020C (retrofit LED tube lamp 20 Watt, Single end connection) OR CROMPTON Make : Crompton Cat No. LTT8-20 LED (retrofit LED tube lamp 20 Watt with AL Heat sink),) OR equivalent of Philips, Wipro complete all as specified and as directed.
S&F in repair LED 10 Watt tube light fitting intergated type, 240 v, PF > 0.90, colour Temp 6500 K, suitable for surface mounting on wall, complete fitting including connecting with PVC insulated multistranded copper flexible cable 0.5 sqmm three core, and PVC round block white colour x 2 Nos for mounting of fitting complete all as specified & directed. Make :- Century Model No. BWUL010C or CG/Philip/Wipro as approved by GE.
S&F in repair LED lamp 18 Watt 4 Pin type, colour Temp 6500K, retrofit type in existing fitting with necessary change in wiring complete all as specified and directed by Engineer in charge. Make : Century/ Bajaj/ Crompton/Philips/Wipro as approved by GE.
S&F in repair LED light with pressure die-cast housing along with prismatic polycarbonate diffuser and LED's with secondary optics and IP-65 protection of 25 watt,PF>0.9 for building security light complete all as specified and directed by Engineer in charge. Make : Century Cat Part No. SPS 025C or Crompton /CG/Philip/Wipro as approved by GE.
Taking down existing u/s CFL light fitting any type (600 mm x 600 mm) recess mounting/surface and S&F LED light fitting 36 watt recess mounting of size 600 mm x 600 mm , white powder coated CRCA housing with LEDs, seam less front frame with flat white high transmission diffisuer, classic design with glare free soft illumination, cool white,including making electric connection from source with PVC sheathed copper conductor wire complete all as specified and directed. . Make : Century Cat No. PCA C 036C or equivalent in CG/Philip/Wipro
Supply and Fixing in repair Glitter LED lamp 7 watt with base GU - 10, CCT 2700K, 560 Lumen, with 2.5K surge protection complete all as specified and directed . Make : Century Cat Part No : LUGL007C equivalent in CG/Philip/Wipro
S&F in repair Polycarbonate angular lamp holder with back plate, suitable for batten fittings including LED bulb 10 watt complete all as specified and directed Make Anchor/ Havells/ Cona/ Leader (white colur) Make of LED Lamp : Century/ Bajaj/ Philips/ Crompton.
S&F in repair PVC casing caping of min 25 mm dia exclusive of boxes (junction/ terminals) but inclusive of all tees, bends, elobows, reducers, bell mouth tube ends and fixing accessories such as coupler, lock nuts, saddles , pipe hook etc to be fixed on surface for dressing of wiring in neat presentable condition by proper relaying of existing PVC cables including removing of cables/ wires and relaying after fixing of new casing capping complete all as specified and directed .
Supply and fixing in repair PVC insulated multistranded Copper conductor, sheathed round cable ISI marked 2.5 sqmm x 3 core complete all as specified and directed by Engr-in-charge. Make : Finolex/ Havells
Supply and Fix, Double Door, Sheet Metal Enclosure for DBs for mounting of MCB for 240 Volts, 4 way, with 200 Amps rated bus bar, Single Pole & Neutral, fixed in repairs including blanking plate , complete all as specified and directed. [Cat No. 5076 10 of Make Legrand or equivalent Model of Make L&T/ Seimens]
Supply and Fix, Double Door, Sheet Metal Enclosure for DBs for mounting of MCB for 240 Volts, 8 way, with 100 Amps rated bus bar, Single Pole & Neutral, fixed in repairs including blanking plate , complete all as specified and directed. [Cat No. 5076 11 of Make Legrand or equivalent Model of Make L&T/ Seimens]
Supply and Fix, Double Door, Sheet Metal Enclosure for DBs for mounting of MCB for 240 Volts, 12 way, with 100 Amps rated bus bar, Single Pole & Neutral, fixed in repairs, including blanking plate complete all as specified and directed. [Cat No. 5076 12 of Make Legrand or equivalent Model of Make L&T/ Seimens]
Supply and Fix, Single Door, Sheet Metal Enclosure for DBs for mounting of MCB for 240 Volts, 2 way, with 100 Amps rated bus bar, Single Pole & Neutral, fixed in repairs, including blanking plate complete all as specified and directed. [ Make Legrand or equivalent Model of Make L&T/ Seimens]
S&F DB Box, in sheet metal enclosure VT DB TPN, MCCB DB TPN 6 way, double door with 100 Amp,25 KA,TP MCCB as incomer (Vertical type double door, 100 Amps, TP, 25 kA MCCB rate inclusive) and suitable for SP/TP DB in outgoing, enclosure made up of CRCA sheet steel, RAL 9003 powder coated, IP 54, IK 09, As Per IEC 61439-3, with 250 Amp copper bus bar for each phase, with 2 Neutralbar, 2 Earth bar and cable ties for cable management, with fully insulated busbar and shrouded neutral bar, reversible door provision, with colour coded interconnecting wire set, including flushing and fixing DB box in neaty in wall complete all as specified and directed by Engr-in-charge. : Make- Legrand Cat Part No. 507751 Model: (Ekinox-3) , MCCB 100 Amp Cat No. Model : DPX -3 or equivalent in Seimens/ Schinder. Note : (i) MCCB and DB box shall be of same make.
S&F DB Box, in sheet metal enclosure VT DB TPN, MCCB DB TPN 4 way, double door with 63 Amp,25 KA,TP MCCB as incomer (Vertical type double door, 63 Amps, TP, 25 kA MCCB rate inclusive) and suitable for SP/TP DB in outgoing, enclosure made up of CRCA sheet steel, RAL 9003 powder coated, IP 54, IK 09, As Per IEC 61439-3, with 250 Amp copper bus bar for each phase, with 2 Neutralbar, 2 Earth bar and cable ties for cable management, with fully insulated busbar and shrouded neutral bar, reversible door provision, with colour coded interconnecting wire set, including flushing and fixing DB box in neaty in wall complete all as specified and directed by Engr-in-charge. : Make- Legrand Cat Part No. 507751 Model: (Ekinox-3) , MCCB 63 Amp Cat No. , Model : DPX -3 or equivalent in Seimens/ Schinder. Note : (i) MCCB and DB box shall be of same make.
S&F DB Box, in sheet metal enclosure VT DB TPN, MCB DB TPN 4 way, double door, with MCB as incomer, enclosure made up of CRCA sheet steel, RAL 9003 powder coated, IP 54, IK 09, As Per IEC 61439-3, with 100 Amp copper bus bar for each phase, with 2 Neutralbar, 2 Earth bar and cable ties for cable management, with fully insulated busbar and shrouded neutral bar, reversible door provision, with colour coded interconnecting wire set, with provision for FP MCB as incomer and SP/TP MCB`s as out going, including flushing and fixing DB box in neaty in wall complete all as specified and directed by Engr-in-charge. : Make- Legrand Cat Part No. 507725 or equivalent in Seimens/ Schinder. Note : (i) MCB and DB box shall be of same make.
S & F MCB SP 6-32 Amp , AC , 220 Volt , breaking capacity 10 kA , C-curve , ISI marked, as per IS 60898-1 2002 complete all as specified & directed.
S & F MCB SPN 6-32 Amp , AC , 220 Volt , breaking capacity 10 kA , C-curve , ISI marked, as per IS 60898-1 2002 complete all as specified & directed.
S & F MCB TP 6-32 Amp , AC , 415 Volt , breaking capacity 10 kA , C-curve , ISI marked, as per IS 60898-1 2002 complete all as specified & directed.
S & F in repair MCB, 4 Pole, 40-63 Amp , AC , 415 Volt , 10 kA , C-curve , ISI marked, as per IS 60898-1 2002 complete all as specified & directed.
S & F in repair single pole and neutral enclosure with two pin and earth, plug and socket , suitable for single phase 240 V,complete with one single pole MCB of capacity 20 amps having `C` charactristic, breaking capacity 10 KA, including industial plug top, complete all as specified and as directed. Make : Legrand cat part No. 607841 or equivelent in Schinder/ L&T.
Materials and Labour for earthing complete with galvanized steel earth plate electrode 600 mm x 600 mm x 6.0 mm thick buried directly in ground vertically to a depth not less than 2.25 meter deep below ground level with top edge earth plate at a depth not less than 1.5M below normal ground level connected to galvanized steel earth lead wire 4 mm dia. by means of bolts, nuts check nuts and washers of galvanized steel and connected to main switch board or main control board as directed and including provision of concrete pit in PCC (1:3:6) type C1, pre-cast RCC (1:2:4) type B1 cover slab 54 cm x 54 cm x 5 cm reinforced 8 mm dia TMT bars @ 150 center to center both ways, with one handle for lifting made out of 8 mm dia MS bar, provision of funnel, wire mesh, 20 mm bore galvanized steel tubing (Medium grade) for watering, charcoal or coke and salt in alternate layers, 15 mm bore galvanized steel tubing light grade for protection of earth lead connection, necessary excavation and earth work in any type of soil and including necessary testing complete all as shown on electrical plate No 3 of SSR Part –I .(Note: (i) Unit rate of earthing deemed to be included with GI wire 4 mm, GI pipe light grade protection pipe 15 mm up to 7.5 RM) (ii) Since the resistivity of soil is high contractor shall bring the agriculture soil from out side defence land to fill the earth pit and rate shall be deemed to be included in quoated rates
Materials and labour for painting of ceiling fans complete, in situ with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dust etc. including writing letters or figures (Block,Roman, Italic or Indian) n exc. 2.5 cm high and stops, commas, short lines, dashes,hyphens, brackets, etc. for writing MES/SM No., complete all as specified and directed.
Materials and labour for painting of exhaust fans complete, in situ with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dust etc. including writing letters or figures (Block,Roman, Italic or Indian) n exc. 2.5 cm high and stops, commas, short lines, dashes,hyphens, brackets, etc. for writing MES/SM No., complete all as specified and directed.
Supply and Fixing LED bulb 10 watt with B22 base, 1100 lumen, 6500 K.complete all as specified and directed. Make : Century Cat Part No : LUGR010C or equivalent make Wipro/Philips/Crompton
S&F in repair single phase direct connection type KWH meter , temper proof, plastic body with LCD display, 230/240V, 5-30 Amp, accuracy class I, 50 Hz, Conforming to IS 13779, IP 54, with ( parameters to show Date, time, current reading, KW, PF) in existing position by providing Polycarbonate box cover, including making complete electric connections complete all specifed and directed Make : Secure (Model Saral) or eqivelent in L&T Note : Old meter to be deposite in AGE E/M store.
Guru Charan Mahata
JEETEN ENTERPRISE
Universal Traders
VICKY ENTERPRISE
M/s Santosh Industrial Corporation
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .