Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.4 CrAccepted-AOC 1 225 5 6 SADAR BAZAR DELHI CANTT 110010 | NEW DELHI | DELHI | 110010 | ₹3.4 Cr Quoted ₹3.5 Cr | L1 | Accepted-AOC Being lowest |
| 2 | L2₹4.0 Cr+₹53.4 L (15.3%)Rejected-Finance 13 29 3RD FLOOR EAST PATEL NAGAR NEW DELHI 110 008 | WEST | DELHI | 110008 | ₹4.0 Cr+₹53.4 L (15.3%) | L2 | Rejected-Finance Being other than lowest |
| 3 | L3₹4.1 Cr+₹57.9 L (16.6%)Rejected-Finance I 910 JAHANGIR PURI NEAR BY ANAND MAYA HOSPITAL NORTH WEST DELHI DELHI 110033 UDYAM DL 06 0040830 | NORTH DELHI | DELHI | 110033 | ₹4.1 Cr+₹57.9 L (16.6%) | L3 | Rejected-Finance Being other than lowest |
| 4 | L4₹4.2 Cr+₹72.1 L (20.6%)Rejected-Finance STREET NO 11 SECTOR NO 04 TILAK NAGAR SAGAR ROAD BIKANER RAJASTHAN 334001 | BIKANER | RAJASTHAN | 334001 | ₹4.2 Cr+₹72.1 L (20.6%) | L4 | Rejected-Finance Being other than lowest |
| 5 | L5₹4.2 Cr+₹73.3 L (21.0%)Rejected-Finance | ₹4.2 Cr+₹73.3 L (21.0%) | L5 | Rejected-Finance Being other than lowest |
Tender Value
₹4.5 Cr
EMD Value
₹5.2 L
Closing Date
12 Nov 2024, 6:00 pmClosed
CWE AF Gwalior
HQ CWE AF Gwalior 474020
IMPROVEMENT TO ELECTRICAL INFRASTRUCTURE IN DOMESTIC AREA AT AF STN GWALIOR
2024_MES_676632_1
86002/E8
Open Tender
Electrical and Maintenance Works
Item Rate
365 days
AF Stn Gwalior
As per tender documents
8 documents required · 8 mandatory
₹2,000
GE (AF) (Adm Area) Gwalior
₹5.2 L
Yes
3 Jan 2025
25 Sept 2024
19 Nov 2024
25 Sept 2024
12 Nov 2024
5 Nov 2024
Amount
Dismantling & taking down of existing worn out / unserviceable aluminium conductor, steel reinforced (ACSR) of any type /size & in any position from existing LT/HT Poles/Lines all as specified & directed.
Dismantling & taking out of old existing unserviceable steel & iron items from poles such as cross arms, bracing, supports, clamps and back plate fabricated from structural steel sections including nuts & bolts, washers of any description and in any position from LT overhead line poles/ street light poles complete all as specified & directed by Engineer -in-Charge.
Dismantling & taking out of old existing unserviceable insulators of any description and in any position from LT/HT poles all as specified & directed.
Dismaintling stay assembly any type and any position complete all as specified and as directed.
Dismantling and taking down street light LED/HPSV fitting of any wattage and any size from LT/HT poles with all accessories clamps etc and refixing the same on existing pole complete all as specified and as directed. Note : Any addn/altn for fixing of above fittings deemed to be included in above quoted rates.
Dismantling and taking down of old u/s LT Cable any type laid in trenches or in pipes fixed on pole / wall / laid under road / path / drain /culvert etc complete all as specified and as directed
Dismantling and taking out u/s earthing of any size / type and any specification with all accessories complete all as specified and ass directed by Engr-in-charge.
Dismantling and taking out old serviceable LT cable any size from existing pole and connected to proposed feeder pillar panel complete all as specified and ass directed
Supply, laying, connecting and testing LT 1100-volt grade electric cable XLPE insulated, screened, PVC bedded, galvanised steel strip armoured (heavy duty) ISI marked with aluminium stranded conductor gross sectional area 400 Sqmm, 3.5 core in trenches/on surface of wall/ in GI pipe including dressing and clamping the cable with MS Zinc Passivated clamps and fixing suitable thimbles/lugs including cable glands of suitable size etc complete all as specified and directed. (Note:- Earthwork & excavation shall be measured & paid separately under respective items)
Supply , laying , connecting and testing LT 1100 volt grade electric cable XLPE insulated, screened, PVC bedded, galvanised steel strip armoured (heavy duty) ISI marked with aluminium stranded conductor gross sectional area 150 Sqmm, 3.5 core in trenches/on surface of wall/ in GI pipe including dressing and clamping the cable with MS Zinc Passivated clamps and fixing suitable thimbles/lugs including cable glands of suitable size etc and including cable path indicators at distance of every 100 m duly marked with "MES LT cable" complete all as specified and directed . (Note:- Earthwork & excavation shall be measured & paid separately under respective items)
Supply , laying , connecting and testing LT 1100 volt grade electric cable XLPE insulated, screened, PVC bedded, galvanised steel strip armoured (heavy duty) ISI marked with aluminium stranded conductor gross sectional area 120 Sqmm, 3.5 core in trenches/on surface of wall/ in GI pipe including dressing and clamping the cable with MS Zinc Passivated clamps and fixing suitable thimbles/lugs including cable glands of suitable size etc and including cable path indicators at distance of every 100 m duly marked with "MES LT cable" complete all as specified and directed . (Note:- Earthwork & excavation shall be measured & paid separately under respective items)
Supply , laying , connecting and testing LT 1100 volt grade electric cable XLPE insulated, screened, PVC bedded, galvanised steel strip armoured (heavy duty) ISI marked with aluminium stranded conductor gross sectional area 95 Sqmm, 3.5 core in trenches/on surface of wall/ in GI pipe including dressing and clamping the cable with MS Zinc Passivated clamps and fixing suitable thimbles/lugs including cable glands of suitable size etc and including cable path indicators at distance of every 100 m duly marked with "MES LT cable" complete all as specified and directed . (Note:- Earthwork & excavation shall be measured & paid separately under respective items)
Supply , laying , connecting and testing LT 1100 volt grade electric cable XLPE insulated, screened, PVC bedded, galvanised steel strip armoured (heavy duty) ISI marked with aluminium stranded conductor gross sectional area 70 Sqmm, 3.5 core in trenches/on surface of wall/ in GI pipe including dressing and clamping the cable with MS Zinc Passivated clamps and fixing suitable thimbles/lugs including cable glands of suitable size etc and including cable path indicators at distance of every 100 m duly marked with "MES LT cable" complete all as specified and directed . (Note:- Earthwork & excavation shall be measured & paid separately under respective items)
Supply , laying , connecting and testing LT 1100 volt grade electric cable XLPE insulated, screened, PVC bedded, galvanised steel strip armoured (heavy duty) ISI marked with aluminium stranded conductor gross sectional area 50 Sqmm, 3.5 core in trenches/on surface of wall/ in GI pipe including dressing and clamping the cable with MS Zinc Passivated clamps and fixing suitable thimbles/lugs including cable glands of suitable size etc and including cable path indicators at distance of every 100 m duly marked with "MES LT cable" complete all as specified and directed . (Note:- Earthwork & excavation shall be measured & paid separately under respective items)
Supply , laying , connecting and testing LT 1100 volt grade electric cable XLPE insulated, screened, PVC bedded, galvanised steel strip armoured (heavy duty) ISI marked with aluminium stranded conductor gross sectional area 35 Sqmm, 3.5 core in trenches/on surface of wall/ in GI pipe including dressing and clamping the cable with MS Zinc Passivated clamps and fixing suitable thimbles/lugs including cable glands of suitable size etc and including cable path indicators at distance of every 100 m duly marked with "MES LT cable" complete all as specified and directed . (Note:- Earthwork & excavation shall be measured & paid separately under respective items)
Supply , laying , connecting and testing LT 1100 volt grade electric cable XLPE insulated, screened, PVC bedded, galvanised steel strip armoured (heavy duty) ISI marked with aluminium stranded conductor gross sectional area 25 Sqmm, 4 core in trenches/on surface of wall/ in GI pipe including dressing and clamping the cable with MS Zinc Passivated clamps and fixing suitable thimbles/lugs including cable glands of suitable size etc and including cable path indicators at distance of every 100 m duly marked with "MES LT cable" complete all as specified and directed . (Note:- Earthwork & excavation shall be measured & paid separately under respective items)
Supply , laying , connecting and testing LT 1100 volt grade electric cable XLPE insulated, screened, PVC bedded, galvanised steel strip armoured (heavy duty) ISI marked with aluminium stranded conductor gross sectional area 16 Sqmm, 4 core in trenches/on surface of wall/ in GI pipe including dressing and clamping the cable with MS Zinc Passivated clamps and fixing suitable thimbles/lugs including cable glands of suitable size etc and including cable path indicators at distance of every 100 m duly marked with "MES LT cable" complete all as specified and directed . (Note:- Earthwork & excavation shall be measured & paid separately under respective items)
Supply , laying , connecting and testing LT 1100 volt grade electric cable XLPE insulated, screened, PVC bedded, galvanised steel strip armoured (heavy duty) ISI marked with aluminium stranded conductor gross sectional area 10 Sqmm, 2 core in trenches/on surface of wall/ in GI pipe including dressing and clamping the cable with MS Zinc Passivated clamps and fixing suitable thimbles/lugs including cable glands of suitable size etc and including cable path indicators at distance of every 100 m duly marked with "MES LT cable" complete all as specified and directed . (Note:- Earthwork & excavation shall be measured & paid separately under respective items)
Supply , laying , connecting and testing LT 1100 volt grade electric cable XLPE insulated, screened, PVC bedded, galvanised steel strip armoured (heavy duty) ISI marked with aluminium stranded conductor gross sectional area 10 Sqmm, 4 core in trenches/on surface of wall/ in GI pipe including dressing and clamping the cable with MS Zinc Passivated clamps and fixing suitable thimbles/lugs including cable glands of suitable size etc and including cable path indicators at distance of every 100 m duly marked with "MES LT cable" complete all as specified and directed . (Note:- Earthwork & excavation shall be measured & paid separately under respective items)
Supply, installation, commissioning and testing of 315 KVA, 11/0.433 KV, 3 phase, 50 Hz, ONAN cooled oil immersed Copper wound outdoor type step down transformer, Level III type confirming to IS 2026 complete with first filling of IS: 335 ISI Marked filtered & dehydrated transformer oil and other standard fittings/ accessories and 7 position off circuit tap changer (tapping range +7.5% in steps of 2.5% each) with vector Group dyn-11. It shall be oil immersed, naturally cooled, copper wound, winding core type MS radiator cooled tank with first fill of transformer oil plus spare oil (five percentage) capacity) as per IS 335 of 1980 with cooling system. The temperature of oil shall not be raised more than 50 degree centigrade to ambient temp and 55 degree centigrade of winding. Transformer shall be painted with two coat of epoxy paint as per IS- 632. The Transformer shall be provided with the following: - (a) Rating and diagram (terminal marking) plate (b) Two earthing terminals for body earthing and two for neutral earthing (c) Cover lifting eye and transformer lifting lugs. (d) Thermometer pocket (e) Air release hole with plug (f) Tap changer with locking provision (g) Plain withdrawal type oil level gauge (h) Dehydrating breathing device which could not permit ingress of rain water and insects. (j) Filter valve with threaded adaptor at top & bottom (k) Oil conservator with filling hole and cap, drain valve magnetic oil level gauge oil level indicator. (l) Silica gel breather with connecting pipe with fill of dehydrating agent and oil seal
Contd..../- (m) Shut off valve between conservator tank and main tank. (n) Explosion relief vent mounted on tank with double diaphragm and equaliser pipe conservator of space (Pressure release valve) (o) Hand hole of sufficient size for access to the interior of tank. (p) Inspection Cover (q) Jockey pads (r) Skids. (s) Extra busing for neutral on LV side (t) Clamping device for clamping the transformer with foundation channel. (u) HV bushing with arcing horn on HV side. (v) Cable end box on secondary side LV side. (w) Winding temperature indication with alarm and trip contacts. Note: Fencing and gate all around the transformer shall be provided as per TD drawing No CEPZ/ 98/TD/6 sh 2/2 and the same shall be measured and paid under respective items of Schedule “A” (BOQ)..
Supply, installation, commissioning and testing of 630 KVA, 11/0.433 KV, 3 phase, 50 Hz, Onan cooled oil immersed Copper wound outdoor type step down transformer, Level III type confirming to IS 2026 complete with first filling of IS: 335 ISI Marked filtered & dehydrated transformer oil and other standard fittings / accessories and 7 position off circuit tap changer (tapping range +7.5% in steps of 2.5% each) with vector Group dyn-11. It shall be oil immersed, naturally cooled, copper wound, winding core type MS radiator cooled tank with first fill of transformer oil plus spare oil (five percentage) capacity) as per IS 335 of 1980 with cooling system. The temperature of oil shall not be raised more than 50 degree centigrade to ambient temp and 55 degree centigrade of winding. Transformer shall be painted with two coat of epoxy paint as per IS- 632. The Transformer shall be provided with the following: - (a) Rating and diagram (terminal marking) plate (b) Two earthing terminals for body earthing and two for neutral earthing (c) Cover lifting eye and transformer lifting lugs. (d) Thermometer pocket (e) Air release hole with plug (f) Tap changer with locking provision (g) Plain withdrawal type oil level gauge (h) Dehydrating breathing device which could not permit ingress of rain water and insects. (j) Filter valve with threaded adaptor at top & bottom (k) Oil conservator with filling hole and cap, drain valve magnetic oil level gauge oil level indicator. (l) Silica gel breather with connecting pipe with fill of dehydrating agent and oil seal
Contd..../- (m) Shut off valve between conservator tank and main tank. (n) Explosion relief vent mounted on tank with double diaphragm and equaliser pipe conservator of space (Pressure release valve) (o) Hand hole of sufficient size for access to the interior of tank. (p) Inspection Cover (q) Jockey pads (r) Skids. (s) Extra busing for neutral on LV side (t) Clamping device for clamping the transformer with foundation channel. (u) HV bushing with arcing horn on HV side. (v) Cable end box on secondary side LV side. (w) Winding temperature indication with alarm and trip contacts. Note: : Fencing and gate all around the transformer shall be provided as per TD drawing No CEPZ/ 98/TD/6 sh 2/2 and the same shall be measured and paid under respective items of Schedule “A” (BOQ).
Contdd... (C) OUTGOING: - (a) MCCB -160 Amps, ICU 36 KA, 3 Pole -01 Nos, with thermal setting. (b) MCCB -100 Amps, ICU 36 KA, 3 Pole -02 Nos, with thermal setting. (c) MCCB - 63 Amps, ICU 36 KA, 3 Pole -01 Nos. (d) MCB TPN 32 Amp -01 No (e) Supply and fixing inside of panel time switches astro type (Having logitude and latitude of Indian cities in memory including air break power contactor) 415 V single phase of 15 Amp rating with cotactor fitted inside steel enclosure. (f) Spare slots for MCCB Maximum capacity of Out going -01 Nos
Supply, install, testing and commission of LT Panel outdoor type IP-54 protection as per IS-2147 CPRI approved (Design approved assembly) suitable for AC supply 3 phase 4 wire, 415 V, 50 Hz having dust and vermin proof MS sheet 3.15 mm thick with suitable appropriate size complete powder coated externally and internally after carrying out pre coating seven tank process, thickness of powder coating shall be not less than 80 micron. Colour shade of powder coating shall be Siemens Gray (RAL 7032) fixed on plateform constructed in C shape of required size all as specified in PS clause 21.5 (xvii) comprising of controlling MCCB/ACB supported on F class DMC/FRP insulator with short circuit withstand capacity 21 MVA for 1 second, the fixing of the doors shall be such that the doors should automatically come to closed and the following accessories :- (A) INCOMING: - (a) MCCB 630 Amps 4 pole, 50 Hz, 415 V with rupturing capacity 36 KA with up to provn of 70% thermal setting -01 No (b) Phase indicating lamps LED type RYB including holder with MCB control of suitable size (set of three) - 01 set (c) Volt meter digital type 0-500 volts -01 No (d) Ammeter digital type0- 1000 Amp - 01 No B: Aluminium bus bar Suitable for 600 Amp load 415 Volt distribution system - 01 set
Contd.... (C) OUTGOING: - (a) MCCB 200 Amps 3 pole, 50 Hz, 415 V with rupturing capacity 35 KA with up to provn of 70% thermal setting -03 No (b) MCCB 150 Amps 3 pole, 50 Hz, 415 V with rupturing capacity 35 KA with up to provn of 70% thermal setting -01 No (c) MCB TPN 32 Amps 3 pole, 50 Hz, 415 V with rupturing capacity10 KA with up to provn of 70% thermal setting -01 No (d) Supply and fixing inside of panel time switches astro type (Having logitude and latitude of Indian cities in memory including air break power contactor) 415 V single phase of 32 Amp rating with contactor fitted inside steel enclosure. (e) Spare slots for MCCB Maximum capacity of Outgoing -01 Nos
Contd.. (C) OUTGOING (a) MCCB - 200 Amps, ICU 36 KA, 3 Pole -01 No. with thermal setting. (b) MCCB - 125 Amps, ICU 36 KA, 3 Pole -01 Nos , with thermal setting (c) MCCB - 100 Amps, ICU 36 KA, 3 Pole -01 Nos, with thermal setting (d) MCB TPN 32 Amp -02 No (e) Supply and fixing inside of panel time switches astro type (Having logitude and latitude of Indian cities in memory including air break power contactor) 415 V single phase of 20 Amp rating with cotactor fitted inside steel enclosure. (f) Spare slots for MCCB Maximum capacity of Out going -01 Nos
Contd... (C) OUTGOING (a) MCCB - 200 Amps, ICU 36 KA, 3 Pole -01 Nos, with thermal setting (b) MCCB -150 Amps, ICU 36 KA, 3 Pole -03 Nos, with thermal setting (c) MCCB - 125 Amps, ICU 36 KA, 3 Pole -01 Nos , with thermal setting (d) MCB TPN 32 Amp -01 No (e) Supply and fixing inside of panel time switches astro type (Having logitude and latitude of Indian cities in memory including air break power contactor) 415 V single phase of 15 Amp rating with cotactor fitted inside steel enclosure. (f) Spare slots for MCCB Maximum capacity of Out going -01 Nos
contdd.. (C) OUTGOING (a) MCCB 200 Amps 3 pole, 50 Hz, 415 V with rupturing capacity 35 KA with up to provn of 70% thermal setting -01 No (b) MCCB 150 Amps 3 pole, 50 Hz, 415 V with rupturing capacity 35 KA with up to provn of 70% thermal setting -01 No (c) MCB TPN 63 Amps 3 pole, 50 Hz, 415 V with rupturing capacity10 KA with up to provn of 70% thermal setting -03 No (d) MCB TPN 32 Amps 3 pole, 50 Hz, 415 V with rupturing capacity10 KA with up to provn of 70% thermal setting -02 No (e) Supply and fixing inside of panel time switches astro type (Having logitude and latitude of Indian cities in memory including air break power contactor) 415 V single phase of 32 Amp rating with contactor fitted inside steel enclosure. (f) Spare slots for MCCB Maximum capacity of Out going -01 Nos
Contd.. (C) OUTGOING (a) MCCB - 150 Amps, ICU 36 KA, 3 Pole -01 No. (b) MCCB - 125 Amps, ICU 36 KA, 3 Pole -02 Nos (c) MCCB - 100 Amps, ICU 36 KA, 3 Pole -01 Nos (d) MCB TPN 32 Amp 3 Pole -01 No (e) Supply and fixing inside of panel time switches astro type (Having logitude and latitude of Indian cities in memory including air break power contactor) 415 V single phase of 20 Amp rating with cotactor fitted inside steel enclosure. (f) Spare slots for MCCB Maximum capacity of Out going -01 Nos
Contd.. (C) OUTGOING (a) MCCB - 150 Amps, ICU 36 KA, 3 Pole -02 No. (b) MCCB - 125 Amps, ICU 36 KA, 3 Pole -02 Nos (c) MCB TPN 32 Amp 3 Pole -01 No (d) Supply and fixing inside of panel time switches astro type (Having logitude and latitude of Indian cities in memory including air break power contactor) 415 V single phase of 20 Amp rating with cotactor fitted inside steel enclosure. (e) Spare slots for MCCB Maximum capacity of Out going -01 Nos
Supply, install, testing and commission of LT Panel outdoor type IP-54 protection as per IS-2147 CPRI approved (Design approved assembly) suitable for AC supply 3 phase 4 wire, 415 V, 50 Hz having dust and vermin proof MS sheet 3.15 mm thick with suitable appropriate size complete powder coated externally and internally after carrying out pre coating seven tank process, thickness of powder coating shall be not less than 80 micron. Colour shade of powder coating shall be Siemens Gray (RAL 7032) fixed on plateform constructed in C shape of required size all as specified in PS clause 21.5 (xvii) comprising of controlling MCCB/ACB supported on F class DMC/FRP insulator with short circuit withstand capacity 21 MVA for 1 second, the fixing of the doors shall be such that the doors should automatically come to closed and the following accessories :- (A) INCOMING (a) MCCB 630 Amps 4 pole, 50 Hz, 415 V with rupturing capacity 36 KA with up to provn of 70% thermal setting -01 No (b) Phase indicating lamps LED type RYB including holder with 0.5 A MCB-01 set (set of three) (c) Volt meter digital type 0-500 volts -01 No (d) Ammeter digital type0- 500 Amp - 01 No B: Aluminium bus bar Suitable for 450 Amp load 415 Volt distribution system - 01 set (set of four)
Contd.. (C) OUTGOING (a) MCCB 200 Amps 3 pole, 50 Hz, 415 V with rupturing capacity 35 KA with up to provn of 70% thermal setting -02No (b) MCCB 150 Amps 3 pole, 50 Hz, 415 V with rupturing capacity 35 KA with up to provn of 70% thermal setting -01 No (c) MCCB 125 Amps 3 pole, 50 Hz, 415 V with rupturing capacity 35 KA with up to provn of 70% thermal setting -01 No (d) MCB TPN 63 Amps 3 pole, 50 Hz, 415 V with rupturing capacity10 KA with up to provn of 70% thermal setting -01 No (e) MCB TPN 32 Amps 3 pole, 50 Hz, 415 V with rupturing capacity10 KA with up to provn of 70% thermal setting -01 No (f)Supply and fixing inside of panel time switches astro type (Having logitude and latitude of Indian cities in memory including air break power contactor) 415 V single phase of 32 Amp rating with cotactor fitted inside steel enclosure. (g) Spare slots for MCCB Maximum capacity of Out going -01 Nos
Note For Item No. 22.00 to 32.00: (a) All type of certificates and design verification with switch gears (ACB/MCB) confirming to IS/IEC 61439/2011 Part I & II with Short Circuit Test 4000 Amp with breaking capacity 65 KA shall be submitted by the contractor before execution of work. (b) All test certificate shall be carried out from CPRI/ERDA. (c) All tests as per IEC should from original OEM manufacturer only. (d) Name plate should mention Serial No., Tender ID, CA No and Name of the contractor with manufacturing year. (e) Makes of ACB and MCCB should be same. (f) Breaking/Making capacity of MCCB should have Ics=100% Icu. (g) Panel shall be fitted with chromium plated brass name plate engraved with current rating of the panel and indicating weather it is transformer control panel or otherwise as applicable. (h) Door shall be hinged along with locking arrangement and fixing shall be such that the doors should automatically come to closed position if not kept open with efforts. (j) Danger Notice board size 150 x 100 mm, 2 mm thick fixed on panel at both front and back side
Supply & Fixing Commisning and testing of modular one side extendible 11 KV 630 Amp, 3 phase,50 Hz , outdoor type, SF 6, insulated Ring Main Unit/HT panel 5 way comprising of 02 Number Load break switch (LBS) and 03 Nos of Vacuum Circuit Breaker, with all required interlocking for functional and safety considerations as per site requirement incl provn of padlocking, suitable for ambient temp -5 degree C to 50 digree C mounted on MS angle platform of size not less than 75x75x6 mm, copper bus bars mounted over epoxy/DMS insulators, copper flat bus bars, (for earthing metal clad, CB, LBS, MS angle ), Air insulated metering module, all live parts of the switchboard like bus bars, LBS etc should be enclosed in robotically laser welded single stainless steel tank min 20 mm thick having IP 67 degree of protection with SF 6 as insulating medium, gas pressure indicator with green and red zone, max leakage rate 0.1 % per year, NRV for fill up of gas, housed in min 2 mm CRCA outer enclosure, IP 54 confirming to IEC-62271-1(2017), IS-12729:1988 incl all latest ammendments, painted in polyurethane based powder paint over thermal spary of Zn alloy, Siemens gary shade RAL 7032 confirming to all relevent IS & IEC standereds including the following items :- Load break Switch (LBS), HT 11 KV, with itegral earth switch & fuse trip confirming to IEC 60127, IS 9920 and IS 9921 indoor type 2.0 mm thick CRCA sheet enclosure, interlocked earth switch with following specification. (aa) Rated system voltage 12 KV (ab) Rated current rating 630 Amos. (ac) Nominal system voltage -11 KV, 50 Hz, 3 pole.
Contd..../- (ad) One minute power frequency voltage withstand level-28 KV RMS (Min). (ae) Impulse voltage withstand level-75 KV peak (min). (af)Type of insulation -SF6. (ag) Rated short time with stand current 21 KA/3 sec (min). (ah) Rated short circuit making capacity as per IEC standard . (aj) Type of operating mechanisam-Quick make, Quick break mannual spring assisted toggle, (ak) Interlocking: to prevent simultaneous switching of earth and main switch, with provn of padlocking in Earth/main position. (b) Vacuum Circuit Breaker : 11 KV, 630 Amps, 3 Phase, 50 Hz, 3 Phase indoor type, totally enclosed/metal clad switch gear, overload earth fault and shortcircuit protection, voltmeter rage (0-15 KV) and Ammeter (0-630 Amp), complete of following specifications mentioned in IS/EC 62271-100 & 200 /IS 13118 : 1991 incl latest amedments /additions. (ba) Push buttons for breaker On/OFF. (bb) SCADA complients self powered microprosser based IDMT Relay (3 O/C + 1 E/F) with rechargeble batery with adjustable O/C and E/F element current setting including 1 No Voltage monitoring relay for under voltage /over voltage protection. (bc) One minute power frequency voltage withstand level-28 KV RMS (min). (bd) Impulse voltage withstand level – 75 KV peak (min) (type tested).
Contd..../- (be) Rated Breaking current :21 KA (min) for 3 s (bf) Rated short circuit making current as per IEC standard. (bg) Mechanical and LED indications fr breaker ON, OFF, Earth, TRIP, spring charged. Note : Necessary provision for above LED indications is required and deemed to be included in unit quoted rate (bh) Dual core dual ratio current transformer (CT) chamber compressing of 3 Nos, single phase resin cast /ring core CTs of 200-100/5+5 Amps (Outgoing) accuracy class 0.5 for metering, having class 5 P10 for protection as per IS:2705. (bj) Potential transformer (PT), 3 phase dry type (resin cast) fixed type 11 KV/110 Volts, Accuracy class 0.5 with HT & LT HRC fuses/MCB for primery and secondry complete all as specified and direcetd as per IS:3156-01 set. (bk) Earthing switch rated for full making capacity with provision for safe & reliable position indicator. (c) Misc Provitions : (ca) Volatge indication lamps for all 3 Phases for earth function of RMU. (cb) LED bulb for illumination. (cc) Space heater with termostat. (cd) One set of mechanical indicator for ON/OFF indication for all LBS/circuit breaker/Earth switch, liveline indicator. (ce) Go-No-Go indication based on SF 6 gas pressure. (cf) Multifunction meter in all circuit breakers, Voltmeter in balance.
Supply & Fixing Commisning and testing of modular one side extendible 11 KV 630 Amp, 3 phase,50 Hz , outdoor type, SF 6 insulated Ring Main Unit/HT panel 4 way comprising of 02 Number Load break switch (LBS) and 02 Nos of Vacuum Circuit Breaker, with all required interlocking for functional and safety considerations as per site requirement incl provn of padlocking, suitable for ambient temp -5 degree C to 50 digree C mounted on MS angle platform of size not less than 75x75x6 mm, copper bus bars mounted over epoxy/DMS insulators, copper flat bus bars, (for earthing metal clad, CB, LBS, MS angle ), Air insulated metering module, all live parts of the switchboard like bus bars, LBS etc should be enclosed in robotically laser welded single stainless steel tank min 20 mm thick having IP 67 degree of protection with SF 6 as insulating medium, gas pressure indicator with green and red zone, max leakage rate 0.1 % per year, NRV for fill up of gas, housed in min 2 mm CRCA outer enclosure, IP 54 confirming to IEC-62271-1(2017), IS-12729:1988 incl all latest ammendments, painted in polyurethane based powder paint over thermal spary of Zn alloy, Siemens gary shade RAL 7032 confirming to all relevent IS & IEC standereds including the following items :- Load break Switch (LBS), HT 11 KV, with itegral earth switch & fuse trip confirming to IEC 60127, IS 9920 and IS 9921 indoor type 2.0 mm thick CRCA sheet enclosure, interlocked earth switch with following specification. (aa) Rated system voltage 12 KV (ab) Rated current rating 630 Amos. (ac) Nominal system voltage -11 KV, 50 Hz, 3 pole.
Contd..../- (ad) One minute power frequency voltage withstand level-28 KV RMS (Min). (ae) Impulse voltage withstand level-75 KV peak (min). (af)Type of insulation -SF6. (ag) Rated short time with stand current 21 KA/3 sec (min). (ah) Rated short circuit making capacity as per IEC standard. (aj) Type of operating mechanisam-Quick make, Quick break mannual spring assisted toggle, (ak) Interlocking: to prevent simultaneous switching of earth and main switch, with provn of padlocking in Earth/main position. (b) Vacuum Circuit Breaker : 11 KV, 630 Amps, 3 Phase, 50 Hz, 3 Phase indoor type, totally enclosed/metal clad switch gear, overload earth fault and shortcircuit protection, voltmeter rage (0-15 KV) and Ammeter (0-630 Amp), complete of following specifications mentioned in IS/EC 62271-100 & 200 /IS 13118 : 1991 incl latest amedments /additions. (ba) Push buttons for breaker On/OFF. (bb) SCADA complients self powered microprosser based IDMT Relay (3 O/C + 1 E/F) with rechargeble batery with adjustable O/C and E/F element current setting including 1 No Voltage monitoring relay for under voltage /over voltage protection. (bc) One minute power frequency voltage withstand level-28 KV RMS (min). (bd) Impulse voltage withstand level – 75 KV peak (min) (type tested). (be) Rated Breaking current :21 KA (min) for 3 s
Contd..../- (bf) Rated short circuit making current as per IEC standard. (bg) Mechanical and LED indications for breaker ON, OFF, Earth, TRIP, spring charged. Note : Necessary provision for above LED indications is required and deemed to be included in unit quoted rate (bh) Dual core dual ratio current transformer (CT) chamber compressing of 3 Nos, single phase resin cast /ring core CTs of 200-100/5+5 Amps (Outgoing) accuracy class 0.5 for metering, having class 5 P10 for protection as per IS:2705. (bj) Potential transformer (PT), 3 phase dry type (resin cast) fixed type 11 KV/110 Volts, Accuracy class 0.5 with HT & LT HRC fuses/MCB for primery and secondry complete all as specified and direcetd as per IS:3156-01 set. (bk) Earthing switch rated for full making capacity with provision for safe & reliable position indicator. (c) Misc Provitions : (ca) Volatge indication lamps for all 3 Phases for earth function of RMU. (cb) LED bulb for illumination. (cc) Space heater with termostat. (cd) One set of mechanical indicator for ON/OFF indication for all LBS/circuit breaker/Earth switch, liveline indicator. (ce) Go-No-Go indication based on SF 6 gas pressure. (cf) Multifunction meter in all circuit breakers, Voltmeter in balance. Note For Item No.33.00 & 34.00 :RMU shall be fixed on the plateform as per manufacturer’s instructions.
Supply and installation & Testing factory made CPRI approved LT feeder pillar box for 3 phase, 4 wire, 415 Volt, AC, 50Hz, outdoor, cubical type, weather, dust and vermin proof, pedestal mounting type front operated applications with and including S&F aluminium bus bar rating capacity 400 Amps and neutral 300 Amps rating capacity mounting of insulators, RYB indicator incoming controlled with fixed type MCCB 3 Pole of capacity 250 Amps and breaking capacity Icu= 36KA and outgoing MCCB 100 Amp 3 pole, 25 KA -04 Nos including canopy on top and gland provision in bottom made out of 3 mm thick shall be powder coated externally & internally after carrying out pre coating seven tank process comprises of degreasing, rising, derusting, rinsing, phosphating, rinsing & passivation thickness of powder coating shall be 80 micron, colour shade of powder coating shall be Siements Gray (RAL-7032) complete including locking arrangement and the fixing of the doors shall be such that the doors should automatically come to closed position if not kept open with effort and using suitable angle iron frame and shall be installed on a brick masonary plinth constructed in the C shape of required size using fly ash old size bricks built in CM 1:6. Brick masonary pedestal shall be constructed on 100 mm thick PCC bedding (1:4:8) type D2 (top of PCC bedding 400mm below GL). Height of PCC pedestal above GL shall be 600 mm. Masonry of pedestal shall be plastered 15 mm thick in CM 1:4, surface finished even & smooth using extra cement. Plastered surface of pedestal shall be painted with two coats of cement base paint over a alkali primer. Mild steel Angle Legs of Feeder Piller Box shall be embedded in PCC (1:3:6) type C1, block 150x150x300 mm deep or base channel shall be grouted in CM 1:3 complete all as specified and directed. Cost of civil work for construction of Pedestal and bus bar of aluminium conductor suitable shape and size with and including necessary excavation and grouting work are included in the quoted rates of Feeder Piller.
Material and labour for earthing complete with galvanized steel earth plate electrode 600mm x 600mm x 6mm buried directly in ground vertically to a depth not less than 2.25 metre below normal ground level (with top edge of earth plate not less than 1.5 metre below ground level) connected to galvanized iron earth strip 32 x 6 mm (main earthing lead) by means of galvanized bolts, nuts and washers all as shown in electrical plate No 3 of MES Schedule Part-I (2009) connected to earth test point & to main switch board with & including adequate quantity of charcoal dust and common salt alround earth plate & 40 mm dia GI pipe medium grade for earth lead protection pipe for suitable length and GI pipe 20 mm dia medium grade for watering pipe with funnel & wire mesh including necessary earth work and PCC (1: 3 : 6) type C-1 for earth pit , internal surface of concrete shall be given 10mm thick plaster in CM 1:4 and 40 mm thick precast RCC cover 1 : 2 : 4 ,type B-1( using 20 mm graded crushed stone aggregare ) reinforced with 8 mm dia TMT bars @ 75 mm c/c both ways with 12mm dia round bar as in handle including taking down of existing earthing complete all as specified & directed. Note: (i) Test result of earthing to be submitted by the contractor for all earthing . (ii) Earth filling shall be done by vegetable soil. (iii) Soil should be free from stone, boulders,aggragates,gravel etc. (iv) The rate quoted by the bidders shall be also be deemed to include :-(a) Supply of charcoal and common salt.
M&L for PCC (1:4:8) Type D-2 using 40mm graded stone aggregate as in foundation/repairs to damaged road/footpath/plinth for panels etc. including necessary formwork complete all as specified and directed.
M&L for PCC (1:2:4) Type B-1 using 20mm graded stone aggregate as in repair to footpath/hard standing/plinth for panels etc. including necessary formwork complete all as specified and directed.
Supplying and fixing in position new PVC (Synthetic) boxes of suitable size, made out with PVC. The box shall be provided with and including 10 cm long aluminium bus bar of size 20x3 mm size 4 Nos mounted on porcelain insulators including one No. MCB SPN of ‘C’ series, 5/6 Amps and connecting the bus bars to cables with using suitable GI nut, bolts and washers and aluminium lugs etc fixed on pole using 30x5 mm GI clamps, nuts, bolts & washers etc complete all as specified and directed.
Demolition for cement concrete/road in ground floor and paving n. exc 15 cm thickness below or above ground level including removal of rubbish to a distance exc 500 mtr etc complete all as specified and directed
Supply laying & testing cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor, 11000 volts grade, of size 3 core 95 Sq mm all as specified and directed.
Supply laying & testing cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty ) with stranded aluminium conductor, 11000 volts grade, of size 3 core 120 Sq mm all as specified and directed.
Supply, installation, Commissioning and testing HV Junction box panel factory fabricated CPRI approved size not less than 1.2 x 1 x 1.2 M (LxBxH ) 3 phase 11000 Volts ,AC , 50 Hz supply, Outdoor cubical type, dust and vermin proof, pedestal mounting type having suitable shape/ size canopy on top, made out of outer shell & canopy shall be 3 mm thick whereas partition and inner door shall be made of 2 mm thick CRCA sheet with using the base frame shall be not less than ISMC 75 x40 mm MS angle used for fabrication of legs shall be 50x50x6 mm supports, shall be powder coated externally & internally after carrying out pre coating seven tank process comprises of degreasing, rising, de-rusting, rinsing, phosphating, rinsing & passivation thickness of powder coating shall be 80 micron, colour shade of powder coating shall be Siements Gray (RAL-7032) complete including locking arrangement and including PCC (1:3:6) type C2 block 150x150x300 mm deep or base channel shall be grouted in CM 1:3 and bus bar of aluminium conductor suitable shape and size for 3 phase rating of 600 amps IP-55 Protection all as specified and directed. Note: (i) Platform will be provided as per PS Clause 21.5 (xvii). (ii) Fencing and gate all around the HT Junction Box will be provided as per direction of EIC and the same shall be measured and paid seperately under respective items of sch ‘A’ (BOQ).
Supply and fixing and testing of Cable jointing kit for 11 KV (Earthed) grade cable for indoor termination heat shrink type joint complete (end joint) with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 Sqmm all as specified and directed.
Supply and fixing and testing of Cable jointing kit for 11 KV (Earthed) grade cable for indoor termination Heat shrink type joint complete (end joint) with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 Sqmm all as specified and directed.
Supply and fixing and testing of Cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination cold shrink type joint complete (end joint) with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 Sqmm all as specified and directed.
Supply and fixing and testing of Cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination cold shrink type joint complete (end joint) with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 Sqmm all as specified and directed.
M&L for disconnecting HT & LT supply, dismantling, taking out, lifting up or down old existing transformer any type and capacity up to 400 KVA from existing plateform or 4 pole structure, transporting to new location not exceeding 6 Km away from the starting point and installation of above transformer on new plateform constructed under relevant item of schedule’ A’ (BOQ), connecting HT & LT connection, commissioning and testing the transformer all as specified and directed.
Boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine including Supply and insertion of HDPE pipe of Suitable dia suitable for 0.4 Mpa working pressure as per site requirement all as specified and directed.
S&F cable route indicators made out from CI round disc duly marked as "MES HT CABLE" etc in specified colour mounted on angle iron frame of size 40mmx40mmx5mm welded to frame and embedded in cast in situ PCC lock of size 150x150x300mm deep of mix 1:3:6 type C-1 (using 20mm graded crushed stone aggregate) including equired earthwork & excavation and painting of MS/iron work with two coats of synthetic enamel paint over a coat of red oxide primer etc complete all as specified & directed.
S&F PVC insulated, sheathed twin core 2.5 Sqmm size copper wire duly passing through the holes of existing steel poles/street light brackets including necessary connection at pole mounted street light junction box and at the street light luminaries all as specified and directed.
Supplying and fixing in position new PVC (Synthetic) boxes of size not less than 1000mm X 500mm X 250mm depth (with thickness not less than 4mm), made out with PVC. The box shall be provided suitable aluminium bus bar of size not less than 32x5 mm size 04Nos mounted on porcelain insulators including one No. MCCB FP of 125 Amps and connecting the bus bars to cables with using suitable GI nut, bolts and washers and aluminium lugs etc fixed on pole using 32x5 mm GI clamps, nuts, bolts & washers etc complete all as specified and directed.
Supply & Erecting of steel tubular pole swaged type 410 SP 55 11 mtr long complete in true vertical position in t to IS: 2713 complete with CI base plate, pole cap bolt nuts & screw with cast iron base plate, pole cap, mild steel bolt, nuts and screws complete all as specified and directed including of following work/scope : (a) M & L for painting of pole externally with one coat of black bituminous paint (up to plating depth) and above plinth block complete collar with two coat of aluminium paint over a coat of red oxide primer including preparation of surface including painting of 30 cm wide bands 3 nos with synthetic enamel paint of appropriate colour in alternate layer up to the height of 1.5 mm above plinth block. (b) M&L for writing letter of figures (black roman, italic as Indian) with thick synthetic enamel paint of apprised shade not exceeding 5 cm height including numbering of pole complete all as specified and directed Note : Excavation earth work and PCC will be measured separately.
Supply & fixing new steel & iron cross arms, bracing, supports, clamps and back plate fabricated from structural steel sections including nuts & bolts, washers of any size and in any position to HT/LT overhead line poles/ street light poles complete all as specified & directed.
Supply, fixing, commissioning and testing of outdoor, gang operated air-break switch, tilting type, 11KV of current rating upto 200 Amps, triple pole, each pole consisting of galvanized steel base, HT insulators as per IS, non-ferrous knife and spray, loaded contacts, arcing horns of adequate section to break magnetizing current of the transformers, horizontal GI pipe of adequate length for phase separation, adequate length of GI pipes for operation from ground level and operating handle with locking arrangement complete in both OFF & ON positions. All ferrous parts hot dripped galvanized and non-ferrous heavily tinned to with stand weather and suitable for vertical mounting complete all as specified and as directed by Engineer-in-Charge.
Supply, fixing, commissioning & testing of transmission class lightening arrestor 11 KV of Discharge capacity 65 KA NDC confirming to EC-99 -41/1990 including brackets, clamps, bolts, nuts and washers complete all as specified and directed by Engineer-in-Charge.
M&L in repair, jointing and testing for provision of outdoor straight through joints, heat shrinkable, suitable for XLPE, LT UG Cable, 1100 Volts grade, of size 25-50 Sqmm (Four core) complete kit all as specified and directed.
Excavation in trenches in soft/loose soil not exceeding 1.5 m deep and not exceeding 1.5 mtr wide and getting out including forming bottom surface to required levels/gradients/slopes for foundations/laying of cable etc. all as specified and directed including taking out existing cable protection brick cover etc.
Returning, filling in, including spreading levelling, watering and well ramming the excavated soil in layers not exceeding 25 cm thick complete all as specified and directed
Removal of surplus excavated soil to a distance not exceeding 50 Mtr distance and depositing as directed at a level not exceeding 1.5 mtr above starting point complete all as specified and directed
M&L for sand filling with clean dry fine sand unwashed including gently punning around cables in trenches for cable protection complete all as specified and directed. Note: Only punned thickness shall be measured and paid.
Supplying & laying un-reinforced precast flat concrete cable protection cover of class HV, type I, size 300mm x 180mm x 40mm, factory made, complete all as specified and directed.
M&L bricks for covering underground cable with one layer of bricks using sub class 'B' bricks (Old size) laid flat across the cable complete all as specified. (Note: Excavation and earth work will be measured separately).
S&F 100 mm bore light grade galvanized iron tubing ISI marked including all fittings etc laid in trenches or fixed on wall protection pipe complete all as specified and directed.
S&F 80 mm bore light grade galvanized iron tubing ISI marked including all fittings etc laid in trenches or fixed on wall protection pipe complete all as specified and directed
Supply & Fix 50 mm bore light grade galvanized iron tubing ISI marked including all fittings etc laid in trenches or fixed on wall protection pipe complete all as specified and directed
Supply & Fix 40 mm bore light grade galvanized iron tubing ISI marked including all fittings etc laid in trenches or fixed on wall protection pipe complete all as specified and directed
Supply & Fix 15 mm bore light grade galvanized iron tubing ISI marked including all fittings etc fixed on pole including clamps, nut and bolts protection pipe for street light cable from junction box to street light complete all as specified and directed
Supply & Fix drop out fuse set 11 KV, 200 Amps mounted on insulators and steel frame complete all as specified and directed.
M&L for concealed point wiring on wall and surface wiring on ceilling/ roof with necessary arrangments with 2.5 sqmm single core 1100 volts grade FRLSH PVC insulated unsheathed multistandred copper conductor cable with and including PVC concealed conduit of medium grade with all fittings and modular metal flux box 4 module including modular switch socket outlet 16 Amps for AC, 240 volts, Modular white cover plate with frame 4 module to accomodate all the accessories complete with internal connections, fixed with chromium plate screws and washers and 2.5 sqmm single core 1100 volts grade FRLSH PVC insulated unsheathed multistandred copper conductor as earth continuity conductor connected to common earth dolly and including cutting chases in walls /floors for concealed conduit and making good the distrubed surface by cement mortor (1:3) and to match with the existing surface /colour by using oil bound distemper of existing color complete all as specified and directed. Note : (i) Cost for cutting chases and making good is deemend to be included in quoted rated. (ii)Cost of fittings/blank plate/fixtures as mentioned under item description is deemed to be included in quoted rate.
M&L for concealed point wiring on wall and surface wiring on ceilling/ roof with necessary arrangments with 4 sqmm single core 1100 volts grade FRLSH PVC insulated unsheathed multistandred copper conductor cable with and including PVC concealed conduit of medium grade with all fittings and single pole and neutral enclosure with a two pin and earth plug and socket complete in metal clad board (Industrial type) with one single pole MCB of capacity 20 Amps, 240 Volts complete fixed on wall by provisioning of suitable sizes of MS strips, nuts, bolts and washers all as required for AC, 240 volts complete including 4 sqmm single core 1100 volts grade FRLSH PVC insulated unsheathed multistandred copper conductor as earth continuity conductor connected to common earth dolly and including cutting chases in walls /floors for concealed conduit and making good the distrubed surface by cement mortor (1:3) and to match with the existing surface /colour by using oil bound distemper of existing color complete all as specified and directed. Note : (i) Cost for cutting chases and making good is deemend to be included in quoted rated. (ii)Cost of fittings/fixtures as mentioned under item description is deemed to be included in quoted rate.
Supply and fixing of sheet metal enclosure Double door for DB’s 4 way 240 volts with 200 Amps rated bus bar for single phase and neutral supply complete fixed properly on in concealed position and to connect their incoming/outgoing electric connections by means of suitable sizes of lugs/thimbles and to provide required sizes of flexible conduit at any open surfaces near DB’s of cables/wires all as directed.
S&F MCB single pole 6 to 32 Amps, 'B' curve 10 KA ,240 Volts complete all as specified & directed.
S&F MCB Single pole and neutral 40 Amps, 'C' curve 240 Volts complete all as specified & directed.
M&L for sub-main wiring using two single core PVC insulated, unsheathed stranded copper conductor cable FRLSH of size 6 Sqmm of voltage rating upto and including 1100 Volts grade in and including concealed PVC conduit medium grade of size not less then 20 mm bore along-with one run of PVC(green colour) insulated , unsheathed, stranded copper conductor FRLSH of size 4 Sqmm as earth continuity conductor all as specified and directed. Note : (i) Two run of single core PVC cable with one run of earth conductor and conduit shall be measured as one unit. (ii) Cost for cutting chases and making good is deemend to be included in quoted rated.
Demolition of Brickwork or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles, complete all as specified and directed.
M & L for rendering 15 mm thick on fair faces of brick wall finished even and smooth (without using extra cement) in CM 1:6 complete all as specified and directed.
S&F Powder coated anodised aluminium frame of size 50mmx40mm, thickness not less than 3.252 Kg/Sqm of 1.20 mm thick of aluminium sheet etc for windows, ventilator of size with one or more rebates including joining cleat for fixing etc. complete all as specified and directed.
M&L for preparing new plaster surfaces of Walls and applying two coats of oil bound distemper complete all as specified and directed.
S&F Powder coated anodised aluminium window and ventilator shutters, sliding type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, ACP clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as sliding rollers ,100mm long (1 no.) suitable handle (1no.), tower bolt 100mm (2 no.) complete all as specified and directed by Engr-in-charge.
Supply and fix 5mm thick ACP sheet etc complete all as specified and directed.
M&L two coat of synthetic enamel paint over one coat of red oxide primer on new steel surfaces of any specifically other wise described over 10 cm width or girth complete all as specified and directed.
M&L framed work as in doors or gates of angles or other section with gusset plates, rails braces etc, complete drilled for fixing of steel sheeting or other covering. Doors etc to be prepared for hanging or sliding with including either hooks and hinges or steel hanging door fittings, Fe 410-W (Gde E-250) quality A (exclusive of steel sheeting or other covering, running rails and guides) and hanging, also fastening and fixing complete all as specified and directed.
Demolition of PCC in ground floor & pavings n.exc 15 cm thickness below or above ground level, complete all as specified and directed.
M&L 75 mm thick type D-2 1:4:8 (using 20mm graded stone agg) as in sub base or floor complete all as specified and directed.
M&L for machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60mm thickness M-35 Grade complete all as specified and directed.
M&L for Sand filling under floor including watering and consolidation complete all as specified and directed.
Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1cement:3 coarse sand) including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete all as specified and directed.
Dismantling old existing transformer plateform, any type and size and removal of deberies to distance exceeding 1.5 Km complete all as specified and directed please
M&L for construction of transformer plateform as per recommendation of manufacturer and suitable for transformer 630 KVA capacity complete including earth work, PCC foundation suitable size platform and mounting channel complete all as per site requirements complete all as specified and as directed.
M&L for construction of transformer plinth as per recommendation of manufacturer and suitable for transformer for 315 KVA capacity transformer complete including earth work, PCC foundation suitable size platform and mounting channel complete all as per site requirements complete all as specified and as directed
Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm,in any type of soil complete all as specified and as directed
M & L for cement concrete 1:3:6 type C-2 (using 40 mm graded aggregate) in foundation filling and mass concrete complete all as specified and as directed.
M & L for posts and struts in fencing including cutting tops to shape as directed, drilling holes,notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc.,and similar work conforming to Fe-290 Gde E-165 complete all as specified and as directed
Supply only Chain link MS galvanised fencing any size or type complete all as specified and as directed.
Fixing only Chain link fencing including line wires any mesh, size and type of any type of standards, rails, straining bolts, etc including provision of binding wires complete all as specified and as directed
S&F Mild steel screw bolts (machine made) with hexagonal or square heads at one end screwed the other to be fitted with washers and one hexagonal or square nut not exc.5 cm long & dia of neck 5 to 10mm complete all as specified and as directed
M & L for preparation of new steel surfaces n exc. 10 cm in width or girth and applying two coats of synthetic enamel paint over a coat of red odixe primer complete all as specified and as directed
M&L for providing reinforced cement concrete type B-l,1:2:4 (using 20 mm graded aggregate) in precast posts, fencing posts, straining or terminal posts, struts etc. for fencing, average sectional area exc 100 sq. cm, but n. exc. 250 sqcm with or without chamfered angles and flat, splayed, rounded or mitred tops as directed and fixed complete all as specified and as directed.
M&L for R.C.C M-25 nominal mix in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and as directed
M&L for R.C.C M-25 nominal mix in columns, pillars, piers, posts and struts complete all as specified and as directed
M&L for mild steel TMT bars 10mm dia and over, cut tolength, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed.
Ditto all as item No. 103, but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders complete all as specified and as directed.
Excavating in trenchesfor soft/loose soil n exc1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. nexc 10 sq m on plan and n exc 1.5 m in depth and getting out complete all as specified and as directed.
S & F galvanised 2 stand mild steel barbed wire 2.24 mm dia barbed with 2mm bars at 75mm spacing and straining and fixing to any stand and mils straining bolts incl securing or tying at crossing with & inc galvanised mild steel wire staples pins etc complete all as desired (each line of wire to measured.) complete all as specified and as directed.
M&L for rendering 5mm thick on brick work or concrete surfaces in cement mortar 1:4 finished even and smooth without using extra cement complete all as specified.
M & L for preparation of new plastered surface of walls and applying two coats of cement base paint over one coat of primer. complete all as specified and as directed.
Leo Air and Power Solution pvt Ltd. (BID ID -3163472)
SATISH AND CO (BID ID -3163410)
FRIZO INDIA PVT LTD (BID ID -3162928)
M/s Kohli Builders (BID ID -3163702)
Sant Construction Co. (BID ID -3163490)
GEPS PROJECTS (BID ID -3163670)
SAGGI ELECTRIC COMPANY (BID ID -3163497)
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tenderdocument.pdf
Tender Documents • 1.58 MB
BOQ.xls
BOQ • 0.44 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .