| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.2 LAccepted-Finance SADASHIV PHUGE NAGAR OPP SANDVIK FACTORY RADHIKA RESIDENCY F WING FLAT NO 7 PHUGEWADI PUNE 411 012 | PUNE | MAHARASHTRA | 411012 | L1 | Accepted-Finance Being Lowest (L1) | |
| 2 | L2₹19.6 L+₹2.4 L (13.8%)Rejected-Finance | L2 | Rejected-Finance Not Being Lowest | |
| 3 | L3₹19.6 L+₹2.4 L (13.9%)Rejected-Finance | L3 | Rejected-Finance Not Being Lowest | |
| 4 | L4₹23.0 L+₹5.7 L (33.3%)Rejected-Finance GATE NO 454 01 TAPKIR NAGAR PUNE NASIK HIGHWAY NEAR GANDHARV NAGARI MOSHI PUNE 412 105 | PUNE | MAHARASHTRA | 412105 | L4 | Rejected-Finance Not Being Lowest | |
| 5 | L5₹23.2 L+₹5.9 L (34.4%)Rejected-Finance SHOP NO 259 LOHOGAON ROAD KALWAD KHANDVE NAGAR PUNE 411032 | PUNE | MAHARASHTRA | 411032 | L5 | Rejected-Finance Not Being Lowest |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
21 Mar 2025, 6:00 pmClosed
Shri Vikas Tanwar, IDSE, GE (CME) Khadki
Garrison Engineer (CME) Khadki, Phugewadi, Dapodi, Pune - 411 012
REPAIR/MAINTENANCE OF EARTHING WITH MAINT FREE CHEMICAL EARTHING, LIGHTENING PROTECTIONS AND OTHER CONNECTED WORK AT CME UNDER GE (CME) KHADKI
2024_MES_687672_2
8569/E8
Open Tender
Electrical and Maintenance Works
Item Rate
210 days
Garrison Engineer (CME) Khadki, Phugewadi, Dapodi
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Garrison Engineer (CME) Khadki
₹50,000
Yes
27 Mar 2025
21 Feb 2025
24 Mar 2025
21 Feb 2025
21 Mar 2025
8 Mar 2025
22 Feb 2025 - 7 Mar 2025
Amount
M&L for taking out old unsv earthing and material and labour for maintenance free grounding Solution set earthing comprising of Earthing rod , outer pipe in GI and having minimum diameter of 76mm, 3m in length and inner pipe to have minimum diameter of 32mm, both end properly welded to make them airtight. GI terminal size of 100x50x6mm with 2 Nos M8 holes for termination area in between two pipes filled with dry type chemical powder having high conductivity and make sure no air pockets are left. Electrode must be tested for short circuit test of minimum 40 KA at CPRI/NABL. The earthing electrode will be placed in the ground after a bore is drilled to the depth of 3.5 Mtr. The bore drilling will be done with the help of Pneumatic boring machine, 50 Kgs BFC will be placed in the bore to cover the earthing rod from all sides. BFC will be poured in Slurry form in properly mixed condition. The Earth pit cover Square 300x300x240 mm to be provided to cover the earth Pit and shall be made of reinforced FRP and should be capable of carrying the weight of 5 Tons. Make : U-PROTEC or equivalent in Ashlok earthings/JEF technology NOTE :- (a) Rates of boring 3 Mtr for earth electrode, GI strip 20x3 mm & 40 mm dia protection pipe upto 7.5 Mtr from earth electrode is deemed to be included in the quoted rate. (b) On testing, after, after completion, if the earth resistance <3 ohms is not obtained, earthing will be rejuvenated at no extra cost till the desired earth resistance is obtained. (c ) Test certificate from the OEM has to be produced by the contractorfor the material used in earthing
M&L for taking out old unsv earthing and material and labour for maintenance free grounding Solution set earthing comprising of 17.2 mm Pure copper earthing rod, 3m long, Copper terminal size of 100x50x6mm with 2 Nos M8 holes for termination. Electrode must be tested for short circuit test of minimum 40 KA at CPRI/NABL. The earthing electrode will be placed in the ground after a bore is drilled to the depth of 3.5 Mtr. The bore drilling will be done with the help of Pneumatic boring machine, 50 Kgs BFC will be placed in the bore to cover the earthing rod from all sides. BFC will be poured in Slurry form in properly mixed condition. The Earth pit cover Square 300x300x240 mm to be provided to cover the earth Pit and shall be made of reinforced FRP and should be capable of carrying the weight of 5 Tons. Make : "U-PROTEC" or equivalent in Ashlok earthings/JEF technology NOTE :- (a) Rates of boring 3 Mtr for earth electrode, copper strip 20x3 mm & 40 mm dia protection pipe upto 7.5 Mtr from earth electrode is deemed to be included in the quoted rate. (b) On testing, after, after completion, if the earth resistance <3 ohms is not obtained, earthing will be rejuvenated at no extra cost till the desired earth resistance is obtained. (c ) Test certificate from the OEM has to be produced by the contractorfor the material used in earthing
Supply and fix in replacement Air termination, single pointed aluminium rod 12mm dia and 300mm long end threaded all as specified and as directed.
Supplying and fixing in replacement Copper strip 20 x 3.15mm with saddles and fixing screws etc. for roof conductors and down conductors above ground complee all as specified and directed.
Supplying and fixing in replacement aluminium strip 25 x 3.15mm with saddles and fixing screws etc. for roof conductors and down conductors above ground complee all as specified and directed.
Supplying and fixing in replacement Galvanised iron strip 32 x 6mm buried in ground complee all as specified and directed.
M&L for Test point terminal block made of gun metal or phosphorus bronze size 75 x 75 x 25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex head screw complete all as specified and directed.
Supply and fix in replacement post insulator epoxy LV type suitable for aluminium/GI/copper strip 25 x 4 mm lightening conductor fixed on wall/roof/pole including screw and taking out existing insulator complete all as specified and as directed.
Excavation in trenches n exc 1.5m wide and n exc 1.5m deep and making good surface for laying /removing of cable all as specified and directed by Engr in charge as in
(a) Soft/loose soil
(b) Hard/dense soil
Returning filling in excavated soil in trenches, watering and well ramming in layers n exc 25 cm complete all as specified.
Removal of surplus excavated spoil to distance n exc 50 metre all as specified and directed
Supply & Laying in replacement of Telerex DWC (Double Wall corrugated) HDPE pipe ISI marked of outer dia of 50 mm and inner dia 38 mm polythylene with smooth internal and profiled external surface for non pressure under ground cable incl couplers & bends complete all as specified.
M & L for bituminous road cutting to a width of 45 cm and depth 50 cm for laying of pipe for laying of UG cables and making good with PCC (1:3:6) type cI (using 20mm grade stone aggregate)
Supply , laying and testing cable XLPE insulated screened PVC bedded galvanised steel strip or wire armoured , electric power cables ( heavy duty) with stranded aluminium conductor 1100 volts grade in trenches/ passing through pipe/fixing on walls, floors etc incl using suitable clamp of cross sectional area 2 core 10 Sqmm in and including taking out old one all as specified and directed.
Supplying and laying GI tubing light grade 50 mm dia incl all accessories for encasing cables for mechanical protection , laid under Plinth / Floors/ Paths Culverts or fixed on wall or concealed in wall/floor or along poles with complete accessories such as bends/sockets/reducers/saddles incl necessary threading/drilling works including taking down old tubing . all as specified and directed.
S&F in replacement MCCB 4 pole, 400 Amps, 415 V, 50 kA thermal magnetic release adjustable type complete all as specified and directed. Make : Indoasian/L&T/Legrand/Havells
S&F in replacement MCCB 4 pole, 250 Amps, 415 V, 36 kA thermal magnetic release adjustable type complete all as specified and directed.
S&F in replacement MCCB 4 pole, 160 Amps, 415 V, 25 kA thermal magnetic release adjustable type complete all as specified and directed.
Material and labour for fixing aluminium terminals (thimbles) in 1100 volt LT XLPE cable upto size 50 sqmm incl dismantling old thimbles of any type.
Taking out old unserviceable LT panel and supply, installation, testing & commissioning, dust, weather & vermin proof L.T feeder pillar box (approx size 1.2m x 0.5m x 1.0m) factory fabricated (penal shall be got manufactured from any manufacturer duly approved by CPRI) outdoor cubicle/KIOSK type totally enclosed outer cage fabricated with 3.15mm thick MS sheet with frame made of MS angle iron 50x50x5 mm suitable for operation on 3 phase 4 wire, 440V 50 Hz system, with hinged panel doors on two sides with handles, bottom gland plate and locking arrangement consisting of sufficient Nos of circular cable entry holes at bottom only with suitable PVC/ rubber/ wooden bushes to prevent ingress of water/ vermin etc, inside the enclosure. All the holes shall be fixed with chromium plated brass cable glands for cable entry/exit with & including necessary internal wiring with stranded PVC insulated FRLS copper conductor cables of adequate size. The kiosk/ box shall be powder coated internally /externally of approved colour. Quoted unit rate shall be deemed inclusive of PCC foundation, angle iron legs of 50cm above ground level made of angle iron 50x50x5mm & the following accessories:-
Taking out old unserviceable LT panel and supply, installation, testing & commissioning, dust, weather & vermin proof L.T feeder pillar box (approx size 1.5m x 0.5m x 1.0m) factory fabricated (penal shall be got manufactured from any manufacturer duly approved by CPRI) outdoor cubicle/KIOSK type totally enclosed outer cage fabricated with 3.15mm thick MS sheet with frame made of MS angle iron 50x50x5 mm suitable for operation on 3 phase 4 wire, 440V 50 Hz system, with hinged panel doors on two sides with handles, bottom gland plate and locking arrangement consisting of sufficient Nos of circular cable entry holes at bottom only with suitable PVC/ rubber/ wooden bushes to prevent ingress of water/ vermin etc, inside the enclosure. All the holes shall be fixed with chromium plated brass cable glands for cable entry/exit with & including necessary internal wiring with stranded PVC insulated FRLS copper conductor cables of adequate size. The kiosk/ box shall be powder coated internally /externally of approved colour. Quoted unit rate shall be deemed inclusive of PCC foundation, angle iron legs of 50cm above ground level made of angle iron 50x50x5mm & the following accessories:-
(a) Copper bus bar rectangular 800 Amps full for phase and half for neutral and interconnection of MCCBs to Bus bar mounted on epoxy insulators with colour coding PVC sleeves.-01Job (b) MCCB 400 Amps, 4 pole 415 Volts, 50 Hz ,50 KA, thermal magnetic release adjustable type- 01 No ( Incoming) (c) MCCB 315 Amps, 4 pole 415 Volts, 50 Hz , 36 KA, thermal magnetic release adjustable type- 01 No ( Outgoing) (d) MCCB 200 Amps, 4 pole, 415 Volts, 50 Hz ,25 KA, thermal magnetic release adjustable type - 01 No ( Outgoing) (e) MCCB 160 Amps, 4 pole, 415 Volts, 50 Hz ,25 KA, thermal magnetic release adjustable type - 01 Nos ( Outgoing) (f) MCCB 100 Amps, 4 pole, 415 Volts, 50 Hz ,25 KA, thermal magnetic release adjustable type - 01 Nos ( Outgoing) (g) 3 pole Power contactor 415 Volts, ML - 4, 70 Amps cap - 01 (h) Digital street light timer type - 1 No
Supply, installation, testing and commissioning in replacement weather and vermin proof factory made CPRI approved LT feeder pillar box, out door cubicle/KIOSK type totally enclosed outer cage made out of 3.15 mm thick sheet metal and inner compartments of 2.0 mm thick sheet metal enclosure with angle iron frame of MS angle 50x50x6 mm grouted in CM, 45 cm below ground level and 60 cm above round suitable for operation on 3 phase 4 wire, 440 volts 50 HZ system, with hinged panel doors (covers) on two sides with handles, bottom gland plate and locking arrangement consisting of sufficient Nos of circular cable entry holes at bottom only with suitable PVC/rubber /wooden bushes to prevent ingress of water/vermin etc, inside the enclosure, the required nos of holes to be fixed with chromium plated brass cable glands for cable entry and exit complete with necessary internal wiring with stranded copper conductor PVC insulated cables of adequate size, duly powder coated internally/ externally of approved colour with PCC foundation and aluminum bus bar for 3 phase & neutral mounted on epoxy insulator-01 Set, size 1.8 x 1.5 x 0.6 Mtr (approx) including connecting the following:-
(a) Copper bus bar rectangular 800 Amps full for phase and half for neutral mounted on epoxy insulators with colour coding PVC sleeves.-01 job (b) MCCB 4 pole 630 A thermal magnetic release, adjustable type, 36 kA - 01 No (I/C) (c) MCCB 4 pole 200 A thermal magnetic release, adjustable type, 25 kA- 01 No (d) MCCB 160 Amps 4 pole, 25 KA Make (e) MCCB 4 pole 100 A thermal magnetic release,adjustable type, 16 kA-01 No (f) MCCB 4 pole 63 A thermal magnetic release, adjustable type, 16 kA-01 No (g) Three pole Contactor 63 A Current Rating 70A General use 10A, 415V with coil - 01 No
(h) Digital timer switch with inbuilt backup operated on 415 volts AC 50Hz, - 01 No (i) Digital volt meter 0-500 V -1 No (j) Digital ammeter 0-600 Amps - 1 No (k) Phase indicator lamp LED Type - 1 Set (l) MCB SP 6-32A - 03 No (for street light phase separation) (m) Provision of cubicle to accommodate the above mentioned accessories. (n) Internal wiring of panel board, metering equipment with suitable size PVC insulated, unsheathed, 1100 V grade cable with multistranded copper conductor, including provision of lugs/thimbles on either ends of cable.
Priyanka Power line (BID ID -3262966)
Pritam Electro Mechanical Services (BID ID -3261716)
ONKAR ELECTRIC AND GENERAL STORE (BID ID -3268097)
Rama Electricals (BID ID -3268128)
Sachin Electricals (BID ID -3262760)
metro electrical services (BID ID -3261002)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .