Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.8 LAccepted-AOC | L1 | Accepted-AOC Lowest | |
| 2 | L2₹5.1 L+₹31,812 (6.59%)Rejected-Finance | L2 | Rejected-Finance Highest | |
| 3 | L3₹5.5 L+₹64,891 (13.4%)Rejected-Finance | L3 | Rejected-Finance Highest |
Tender Value
₹4.8 L
EMD Value
₹5,000
Closing Date
30 Sept 2021, 1:00 pmClosed
SE EDC-I, Mathura
Near Kali Mandir, Mathura Cantt, Mathura
The Work for Construction of HT/LT Line and other work at various Village under Business Plan at the area of EDSD-Barsana in the jurisdiction of E.D.D.-IV, Goverdhan, Mathura
2021_DVVNL_621836_1
37/EDC-I(M)/2021-22
Open Tender
Electrical Works
Item Rate
180 days
Mathura
Please refer Tender documents.
2 documents required · 2 mandatory
₹590
Dvvnl Portal (dvvnl.org)
₹5,000
Yes
20 Oct 2022
20 Sept 2021
30 Sept 2021
20 Sept 2021
30 Sept 2021
20 Sept 2021
Amount
Carriage of 8.5 Mtrs. long PCC pole from 132 KV Store Center Mathura to site of work through the Kacha and Pakka road including the work of its loading and unloading at the respective ends including the cost of arrangement of labour, T&P, carrier etc. required for proper completion of work.(Distance 00-70 Kms.)
Carriage of 9/11 Mtrs. long ST pole from 132 KV Store Center Mathura to site of work through the Kacha and Pakka road including the work of its loading and unloading at the respective ends including the cost of arrangement of labour, T&P, carrier etc. required for proper completion of work.(Distance 00-70 Kms.)
Carriage of Line material i.e. conductor, G.I. wire TPMO stay rod, disc insulator, cross arm, Angle channel and other required material from Store Center at 132 KV substation Mathura to the site of work including loading and unloading of material at both ends.
Replacement of 8.5 Mtrs. Long damaged PCC pole by opening of all existing accessories and conductor from damaged pole properly and removal of damaged pole and erect the new pole at same place including fixing of all existing accessories and conductor on the new pole etc. as per direction of supervising engineer. It including the cost of all labour, T&P etc. (including carriage of damaged pole to other place) required for proper completion of work.
Replacement of 9/11 Mtrs. long ST/9 Mtrs. long PCC damaged pole by opening of all existing accessories and conductor from damaged pole properly and removal of damaged pole and erect the new pole at same place including fixing of all existing accessories and conductor on the new pole etc. as per direction of supervising engineer. It including the cost of all labour, T&P etc. (including carriage of damaged pole to other place) required for proper completion of work.
Removal of Arial Bunch Conductor 3x50 sq mm. existing conductor from damaged line/Pole including opening of jumpers etc as per requirement of site and as per direction of Supervising Engineer.
Removal of Arial Bunch Conductor 3x95 sq mm. existing conductor from damaged line/Pole including opening of jumpers etc as per requirement of site and as per direction of Supervising Engineer.
Laying, sagging and stringing and jumpering / binding etc. of new & old Arial Bunch Conductor 3x50 sq mm. in LT lines as per RESPO manual and as per direction of supervising engineer including the cost of arrangement of labour, T&P, carrier etc. required for proper completion of work
Laying, sagging and stringing and jumpering / binding etc. of new & old Arial Bunch Conductor 3x95 sq mm. in LT lines as per RESPO manual and as per direction of supervising engineer including the cost of arrangement of labour, T&P, carrier etc. required for proper completion of work
Dismentling of Existing Distribution Box for removal of Existing Arial Bunch Conductor and Re-Fixing of Distribution Box after laying of New Conductor as per RESPO Norms.
Fixing of New 3 Phase/Single Phase Distribution Box on erected pole as per RESPO Norms.
Cutting of CC Road for making depth foundation for erection of pole.
Replacement of Dameged 11 KV/LT Jumphers
Re-sagging of loose 11 KV as per direction of supervising engineer. It includes the cost of labour, T&P etc required for proper completion of work.
Re-sagging of loose Arial Bunch Conductor as per direction of supervising engineer. It includes the cost of labour, T&P etc required for proper completion of work.
Re-nuzzling of old stay set by opening old binding for better straightening of pole and re-sag the existing conductor of H.T/L.T line properly as per direction of supervising engineer.
Straightening of 8.5/9 Mtr. Long PCC/ST/Rail Pole tilted pole at various places by straightening of pole including the cost of labour ,T&P charges required for proper completion of work.
Removal/Dismantling of consumer’s cable service connection from existing line feeding consumer supply.
Re-installation of consumer’s cable service connection from existing line feeding consumer supply.
Grouting of PCC/ST pole in ratio 1:4:8 cement, sand and brick ballast as per standard norms, including cost of all grouting material.
Chopping of Tree branches to Clear the line route to give 02 meter horizontal and vertical clearance to the line including cost of labour T&P etc.
Carriage of 9/11 Mtrs. long Damaged ST pole from Site to J.E. Store through the Kacha and Pakka road including the work of its loading and unloading at the respective ends including the cost of arrangement of labour, T&P, carrier etc. required for proper completion of work.(Distance 00-70 Kms.)
Carriage of Arial Bunch Conductor 3x50/95 sq mm. from site to J.E. Store including its binding and loading and unloading at both ends as per direction of Supervising Engineer.
GIRDHAR LAL AND SONS
LARK INDUSTRIES
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .