Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.3 LAccepted-AOC | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹36.5 L+₹1.1 L (3.18%)Rejected-Finance | L2 | Rejected-Finance Other than Lowest | |
| 3 | L3₹39.4 L+₹4.0 L (11.4%)Rejected-Finance | L3 | Rejected-Finance Other than Lowest | |
| 4 | L4₹39.5 L+₹4.1 L (11.6%)Rejected-Finance HOUSE NO 01 B JANANA DODI OPP AKSHAY HOTEL RAI KA BAGH JODHPUR RAJASTHAN 342010 | 342010 | L4 | Rejected-Finance Other than Lowest | |
| 5 | L5₹41.4 L+₹6.1 L (17.2%)Rejected-Finance | L5 | Rejected-Finance Other than Lowest |
Tender Value
Refer Docs
EMD Value
₹97,000
Closing Date
5 Mar 2024, 6:00 pmClosed
GE NASIRABAD
Garrison Engineer, Military Engineer Services, Nasirabad, Pin - 305601
SPL REPAIR/REPLACEMENT OF GEYSERS AND DESERT COOLERS AGAINST BER AND SPL REPAIR TO FEEDER PILLAR BOX AT NASIRABAD MIL STN
2024_MES_640910_1
8407/E8
Open Tender
Electrical and Maintenance Works
Item Rate
183 days
GE Nasirabad
MES Contractor enlisted as Class D and above and category b(i) having deposited Standing Security of Rs 1,00,000.00 with dept. Contractors not enlisted in MES should meet the MES enlistment criteria corresponding to appropriate class and category.
6 documents required · 6 mandatory
₹500
Yes
GE NASIRABAD
₹97,000
Yes
13 Mar 2024
6 Feb 2024
7 Mar 2024
6 Feb 2024
5 Mar 2024
20 Feb 2024
6 Feb 2024 - 20 Feb 2024
Amount
S&F installation, testing and commissioning of new water heater storage type, electric suitable for single phase ,50HZ, AC supply, 2 KW heating element, with safety fusible plug confirming to relevant IS of 25 ltrs capacity 05 Star rated fixed with fastner of 6 inches set of 4 and with connection pipes of stainless steel SS 304 grade pack of with PTMT nuts of length 24 Inches and testing complete all as specified and directed. Make:- Havells Monza DX/ Venus Splash Copper 25 CU /Racold Omnis Lux Plus.
S&F installation, testing and commissioning of new water heater storage type, electric suitable for single phase ,50HZ, AC supply, 2 KW heating element, with safety fusible plug confirming to relevant IS of 50 ltrs capacity with not less than 4 star rated fixed with fastner of 6 inches set of 4 and with connection pipes of stainless steel SS 304 grade pack of with PTMT nuts of length 24 Inches and testing complete all as specified and directed. Make:- Havells Monza DX/Racold Platinum Eco.
Supply and fix desert cooler of Standard Size & having Steel Body of at least 24 guage sheet and electric driven single phase having nominal air flow capacity of 5000 CuM per hour or nearest size complete all as specified and directed. (Steel Body) Make of Motor and kit:- khaitan 3 Step.
Taking down carefully copper /aluminium point wiring (light, fan, socket or power) complete, including fittings such as switches, ceiling roses, holders, regulators, sockets etc,removing materials from site and making good disturbed surface of walls, floors etc. complete all as specified and directed.
M & L for point wiring of 2.5 sqmm single core multi stranded copper conductor PVC insulated, sheathed, flame retardent, One 3 pin socket outlet independent, cable 1100 volts grade in PVC caping & casing ISI marked fixed on roof/cielling/wall all as per site requirement with all fixing arrangement like screw, tee, socket,bend etcas per IS including sunk type steel terminal boxes and PVC laminated top sheet covers 3 mm thick complete with earth continuity conductor of size 1.5 sqmm single core copper conductor multistranded cableconnected to common earth dolly complete all as specified and directed.
S & F Sheet metal enclosures ac box with socket plug top and MCBs single pole and neutral enclosure with a two pin and earth plug with socket complete with one single pole 20 Amp MCB complete all as specified and directed. Make: havells or equilent
Supply & fix GI Tubes 15 mm dia medium grade with all fittings and fixed complete to walls/floors/trenches complete all as specified and directed by Engr-in-charge.
S&F of Bib tap brass CP screwed for iron pipe of size 15 mm bore complete all as specified and directed by Engr-in-charge.
S&F in stop valve brass CP high pressure both ends screwed for iron pipe of size 15 mm dia complete all as specified and directed by Engr-in-charge.
M&L in repair for earthing complete with galvanised steel earth plate electrode 60cm X 60cm X 6mm thick, burried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of plate not less than 1.5 mtr below normal ground level connected to galvanized strip 32 X 6mm by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical plate No 3 of SSR Part-I connected to OH conductor on pole/ Panel/ main switch board etc all as specified or indicated and testing on completion including provision galvanized strip protected by 40 mm bore, light grade pipe and watering pipe shall be 20 mm bore medium grade GI pipe including excavation & earth work, PCC pit with RCC cover, charcoal, salt, funnel, GI strip and protection pipe upto 7.5 mtr complete all as specified and directed.
S&F in repairs installation, connecting, commissioning and testing of LT panel with CPRI approved main factory fabricated LT distribution panel board, outdoor type, both side openable including locking arrangement with sliding door bolt , cubical type, 3 phase, 4 wire, 415V, factory made free standing, floor mounting, dust and vermin proof, cubical type, fabricated from 3.15 mm thick MS sheet with anticorrosive coating and finally epoxy polyster powder coating of flint grey shade fully compartmentalised design with 4Nos insulated bus bar each made of high conductivity aluminium suitable for 600 Amps, prewired with suitable size of copper cable/insulated copper strip including PCC work and Iron work for fixing arragement at site suitable earth strips conforming to IS, cable glands, lugs etc suitable for and comprising of the following including taking down old LT panel, complete all as specified and directed by Engr-in-charge. Make of CT - AE, CT Ratio:400/5 Amp
Supply and fix in repairs installation, connecting, commissioning and testing of LT panel with CPRI approved main factory fabricated LT distribution panel board, outdoor type, both side openable including locking arrangement with sliding door bolt , cubical type, 3 phase, 4 wire, 415V, factory made free standing, floor mounting, dust and vermin proof, cubical type, fabricated from 3.15 mm thick MS sheet with anticorrosive coating and finally epoxy polyster powder coating of flint grey shade fully compartmentalised design with 4Nos insulated bus bar each made of high conductivity aluminium suitable for 500 Amps, prewired with suitable size of copper cable/insulated copper strip including PCC work and Iron work for fixing arrangement at site suitable earth strips conforming to IS, cable glands, lugs etc suitable for and comprising of the following including taking down old LT panel, complete all as specified and directed by Engr-in-charge. Make of CT - AE, CT Ratio:400/5 Amp.
Supply fix in repairs installation, connecting, commissioning and testing of LT panel with CPRI approved main factory fabricated LT distribution panel board, outdoor type, both side openable including locking arrangement with sliding door bolt , cubical type, 3 phase, 4 wire, 415V, factory made free standing, floor mounting, dust and vermin proof, cubical type, fabricated from 3.15 mm thick MS sheet with anticorrosive coating and finally epoxy polyster powder coating of flint grey shade fully compartmentalised design with 4Nos insulated bus bar each made of high conductivity aluminium suitable for 500 Amps, prewired with suitable size of copper cable/insulated copper strip including PCC work and Iron work for fixing arragement at site suitable earth strips conforming to IS, cable glands, lugs etc suitable for and comprising of the following including taking down old LT panel complete all as specified and directed by Engr-in-charge.
Supply fix in repairs installation, connecting, commissioning and testing of LT panel with CPRI approved main factory fabricated LT distribution panel board, outdoor type, both side openable including locking arrangement with sliding door bolt , cubical type, 3 phase, 4 wire, 415V, factory made free standing, floor mounting, dust and vermin proof, cubical type, fabricated from 3.15 mm thick MS sheet with anticorrosive coating and finally epoxy polyster powder coating of flint grey shade fully compartmentalised design with 4Nos insulated bus bar each made of high conductivity aluminium suitable for 300 Amps, prewired with suitable size of copper cable/insulated copper strip including PCC work and Iron work for fixing arragement at site suitable earth strips conforming to IS, cable glands, lugs etc suitable for and comprising of the following including taking down old LT panel complete all as specified and directed by Engr-in-charge.-:
Supply, install, testing and commissioning of Bus bar chamber of size 60 cm x 60cm x 40 cm outdoor type suitable for LT 415 volts 3 phase 4 wire system factory made cubical complete materialised dust and vermin proof (protection class IP 54), made out of 3.15mm thick MS sheet (CRCA) including factory made hinged type door both side opening with locking arrangement duly painted with two coats of synthetic enamel paint with powder coated finish over a coat of zinc chrome primer complete all as specified and directed by Engineer-In-Charge. the panel board shall be comprising of the following accessories
Notes:(For item No 11.00 to 15.00)- (i) Rates are deemed to be inclusive of PCC platform of suitable size and 45cm height and 4 Nos legs of 50mmx50mmx6mm and 60 cm in height for fixing the panel (ii) Make of MCCB :-HPL/HAVELLS (iii) Make :-Universal (iv) Make of Voltmeter, Ammeter:- L&T (v) Danger notice plate (02 Nos)in Hindi and English of size 20cmx 15cm shall be fixed on the panel (vi) Contractor provided power coated finish paint on panel and test certificate /CPRI Approval certificate.
S & F in repairs following capacities of MCCBs complete all as specified & directed :- Make :- Havells/L & T/LEGRAND Notes: The Item No 16.01 to 16.07 should be comprises with thermal magnetic release type, Ics=100 % Icu, with adjustable overload setting and adjustable short circuit setting , with thermal release range as per manufacture capacity, Amp including spreader terminals and phase barriers including complete all as specified and directed by Engr-in-charge.
All as per item No.16.00 here in before but MCCB, 415 Volts, 4 pole, adjustable type, 400 Amp, breaking capacity 36 KA as per site requirement on existing LT panel board complete all as specified and as directed .
All as per item No.16.00 here in before but MCCB, 415 Volts, 4 pole, adjustable type, 200 Amp, breaking capacity 36 KA as per site requirement on existing LT panel board complete all as specified and as directed .
All as per item No.16.00 here in before but MCCB, AC, 415 Volts, 4 pole adjustable type, 250 Amps, breaking capacity 36 KA as per site requirement on existing LT panel board complete all as specified and as directed .
All as per item No.16.00 here in before but MCCB, 415 Volts, 4 pole, adjustable type, 160 Amp, breaking capacity 36 KA on existing LT panel board complete all as specified and as directed .
All as per item No.16.00 here in before but MCCB, AC, 415 Volts, 4 pole, adjustable type, 100 Amp, breaking capacity 16 KA on existing LT panel board complete all as specified and as directed .
All as per item No.16.00 here in before but MCCB, AC, 415 Volts, 4 pole, adjustable type, 63 Amp, breaking capacity 16 KA on existing LT panel board complete all as specified and as directed .
All as per item No.16.00 here in before but MCCB, AC, 415 Volts, 4 pole, adjustable type, 25 Amp, breaking capacity 16 KA on existing LT panel board complete all as specified and as directed .
S & F in replacement of 1100 Volts grade Cable with 25 sqmm single core copper conductor PVC round sheathed (flexible) industrial cable complete all as specified & directed.
S & F Aluminium lugs thimple/bottle type of following size including taking down old one complete all as specified & directed.
All as per item No.18.00 here in before but 400 sqmm
All as per item No.18.00 here in before but 240 sqmm
All as per item No.18.00 here in before but 95 sqmm
S&F of danger notice plate 1.6 mm thick mild steel sheet, viterous enamelled white, with letters , figures and conventional skull and bones in signal red colour and fixed with MS clamps, bolts and nuts of approved size for LT of size 20cm x15 cm complete all as specified and directed by Engr-in Charge.
S&F in replacement of damaged LT panel section of front/back/side /top and bottom portion of any size MS sheet with new of required size or thickness and fixing on existing LT panel board including necessary bracing/welding work and drilling works including necessary hinges and two coat of sunthetic thick enamel paint over a coat of red oxide primer complete all as specified and directed by Engr-in Charge.
S & F framed work as in doors or gates of angle made out of Fe 410-W Gde E-250 quality -A or other section with gusset plates, rails, hooks, hinges for sliding arrangement, etc., complete all as specified and as directed by Engr-in Charge.
Cleaning and upkeeping of sub station area, surrounding area of LT Panel/Bus Bar/Feeder pillar box and clearing away all grass vegetation, sapplings,shrubs,bushes under growth roots and trees not exc 30 cm girth ( Measured 1 mtr above the ground level) and removing of rubbish to a distance of 50 mtr out side periphary complete all as specified and directed by Engr-in Charge.
M&L for painting feeder pillar box/LT panels of inside, outside and all six sides including all angle iron legs after preparation of old painted surfaces with one coat of synthetic enamel paint of existing colour complete all as specified & directed by Engr-in Charge.
Supply, fabricating , fixing in repair structural mild steel channel angle iron, flat iron and brackets etc for fabrications of cross arms, bracings, supports, D-clamps, stiffeners, eye hooks, bolts, pole clamps and back plates including nuts, bolts and washers, welding bending cold , or hot drilling holes for insulators bolts in any shape or size as indicated or directed and inclusive of one red oxide primer coat ,one under coat and one finishing coat of aluminium paint complete all as specified and directed by Engr-in-charge. (Note:- Insulators to be measured and paid for separately)
Taking out old unserviceable indicating lamp and S&F R Phase LED indicating lamp complete all as specified and directed.
Taking out old unserviceable indicating lamp and S&F Y Phase LED indicating lamp complete all as specified and directed.
Taking out old unserviceable indicating lamp and S&F B Phase LED indicating lamp complete all as specified and directed.
KIRTIMAN ENTERPRISES
M/s SUNIL ENTERPRISES
Nvimal Engineers and Contractor
M/S JAGDISH PRASAD AIRUN
ENGINEER CORPORATION OF INDIA
PANKAJ ENTERPRISES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .