Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Accepted-Technical 1853 2ND FLOOR BHAGIRATH PALACE SURYA BAZAR CHANDI CHOWK NORTH DELHI DELHI 110006 | NORTH | DELHI | 110006 | Accepted-Technical Accepted |
| 2 | Accepted-Technical G 1 1154A MANSAROVER PARK SHAHDARA DELHI DELHI 110032 | SHAHDARA | DELHI | 110032 | Accepted-Technical Accepted |
| 3 | Accepted-Technical | Accepted-Technical Accepted |
| 4 | Accepted-Technical C 344 GALI NO 2 BLOCK C WEST KARAWAL NAGAR DELHI 110094 | NORTH EAST | DELHI | 110094 | Accepted-Technical Accepted |
| 5 | Not Admitted-Fee/PreQual/Technical | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
₹56.0 L
EMD Value
₹1.1 L
Closing Date
3 Nov 2026, 11:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer (E)
EE(E), PWD EMD (M-251) Ramesh Park Delhi
SH- Operation and Watch and ward of pump installed at various underpasses of Shahdara district Delhi during non-monsoon season under sub division-3/M2533.)
2026_PWD_300556_1
88/EE(E)/PWD NES ED/2026-27
Open Tender
Electrical Works
Percentage
240 days
M-2533
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
₹1.1 L
Yes
5 Nov 2026
27 Oct 2026
3 Nov 2026
27 Oct 2026
3 Nov 2026
27 Oct 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Sub Head-I (Labour)
Providing Pump Operator-cum-Watchman for operation, watch and ward of all electrical installations and accessories installed at various underpasses, including all types of dewatering pumps, DG sets, portable diesel engines, etc., along with cleaning of all electrical accessories, on all days including Sundays and holidays, as per the terms and conditions of the work.
Pump Operator cum Watchman – 05 Nos. (on all days i/c Sunday & Holiday including as & when required(at the time of rain) in non monsoon season.
Note: The Contractor shall be solely responsible for any loss, theft, damage or misplacement of electrical installations, equipment, tools and accessories at site, including pumps, motors, cables, starters, DG sets and other related items. In case of any such loss, theft or damage, the Contractor shall be liable for the same and shall bear all costs and expenses arising therefrom, without any additional financial liability on the Department. | 8 | P/Month | 1,80,818 | ₹14,46,544 |
| 2 | Providing the services of Security Guards at various underpasses on all days, including Sundays and holidays, as per the terms and conditions of the work, for the night shift from 10:00 PM to 6:00 AM.
Security Guards – 05 Nos. (on all days i/c Sunday & Holiday) in non monsoon season.
Note: The Contractor shall be solely responsible for any loss, theft, damage or misplacement of electrical installations, equipment, tools and accessories at site, including pumps, motors, cables, starters, DG sets and other related items. In case of any such loss, theft or damage, the Contractor shall be liable for the same and shall bear all costs and expenses arising therefrom, without any additional financial liability on the Department. | 8 | P/Month | 1,80,590 | ₹14,44,720 |
| 3SH:- II (Material) LED Flood Light, powder coated pressure die cast aluminium (System lumen efficacy ≥120 and<135 lm/Watt). Supplying, of Flood Light, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%, THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66, IK-10, CRI >70, under voltage and over voltage protection, EMI-EMC as per CISPR-15, lenses for beam angle 30 deg-120deg as per the application and the project requirement, suitable tilt able fitting, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 and <135 lm/Watt output. LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C) | |||||
| 3.1 | 200 Watt | 100 | Each | 4,386 | ₹4,38,600 |
| 4LED Street light fixture, powder coated pressure die cast aluminium body (System lumen efficacy ≥120 <135 lm/Watt)Supplying, installation, Testing & Commissioning of Street light LED fixture powder coated pressure die cast aluminium body with driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMIEMC As per CISPR 15 , lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc.as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output. LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). | |||||
| 4.1 | 150 Watt | 300 | Each | 3,152 | ₹9,45,600 |
| 4.2 | 200 Watt | 280 | Each | 4,728 | ₹13,23,840 |
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 3.15 MB
BOQ_401184.xls
BOQ • 0.28 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .