Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance D 55 HAKIKAT RAI RD ADARSH NAGAR DELHI 33 | Admitted-Finance |
| 3 | Admitted-Finance INDEX NO E 108 HQ CWE NO 2 DELHI CANTT J 636 SECTOR 23 SANJAY NAGAR GHAZIABAD UTTAR PRADESH 201002 | GHAZIABAD | UTTAR PRADESH | 201002 | Admitted-Finance |
| 4 | Admitted-Finance | Admitted-Finance |
| 5 | Admitted-Finance | Admitted-Finance |
Tender Value
Refer Docs
EMD Value
₹29,800
Closing Date
28 Sept 2020, 6:00 pmClosed
GE AF FARIDABAD
Garrison Engineer AF Faridabad Dabua Colony Faridabad Haryana Pin-121005
REPAIR REPLACEMENT OF LT CABLES STREET LIGHTS LT PANELS WITH ALLIED WORKS SERVICES AT AF STN DADRI
2020_MES_375848_1
GE (FBD)/AF-20/2020-2021
Open Tender
Civil Works
Item Rate
180 days
AF STATION DADRI
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE AF FARIDABAD
₹29,800
Yes
20 Oct 2020
8 Sept 2020
30 Sept 2020
8 Sept 2020
28 Sept 2020
15 Sept 2020
9 Sept 2020 - 14 Sept 2020
Amount
Removing of surplus excavated soil to a distance not exceeding 50 Mtr from starting point and depositing where directed at a level not exceeding 1.5 Mtr above the starting point all as specified and directed by Engineer-In-Charge.
M&L for sand cushoning with a layer of sand 80mm thick before laying of cable and 150mm thick after laying of cable to trenches complete all as specified and directed by Engineer-In-Charge.
Excavation in trenches in soft/loose soil not exceeding 1.5 Mtr wide and not exceeding 1.5 Mtr depth for laying of cables/poles or foundation etc and getting out all as specified and directed by Engineer-In-Charge.
Returning, filling, including spreading levelling and well ramming in layers not exceeding 25cm apart all as specified and directed by Engineer-In-Charge.
M&L for sub class `B` bricks for cable protection all as specified and directed by Engineer-In-Charge.
M&L for auguring of holes in true horizontal position under road by means of mechanical rig after doing ultrasound to prevent any damage to existing cable/pipe line coming in route 1.5 Mtr deep and not exceeding 50 Mtrs long incl laying HDPE pipe not less than 150mm dia complete all as specified by Engr-in-Charge.
Taking out old UNSV LT UG cable from trench/wall all as per site required any type and size complete all as specified by Engr-in-Charge.
Laying only and connecting of cable XLPE insulated screened PVC bedded galvanised steel strip or wire armoured LT 1100 Volts grade aluminium conductor of cross sectional area 120 Sqmm 3.5 core incl thimbles as required with suitable size of calmps on wall/under trenches etc all as specified and directed by Engr-In-Charge. (Note : Item No 08 to 15 UG cable will be issued under Sch "B" free for fixing only. Item will be issued from MES store Yard AF Stn Dadri)
All as above item ser No 8 but 95 Sq mm 3.5 core complete all as specified and directed by Engr -in-Charge
All as above item ser No 8 but 70 Sq mm 3.5 core complete all as specified and directed by Engr -in-Charge
All as above item ser No 8 but 50 Sq mm 3.5 core complete all as specified and directed by Engr -in-Charge
All as above item ser No 8 but 35 Sq mm 3.5 core complete all as specified and directed by Engr -in-Charge
All as above item ser No 8 but 25 Sq mm 3.5 core complete all as specified and directed by Engr -in-Charge
All as above item ser No 8 but 16 Sq mm 4 core complete all as specified and directed by Engr -in-Charge
All as above item ser No 8 but 10 Sq mm 4 core complete all as specified and directed by Engr -in-Charge
S&F galvanised iron tubing light grade size 40 mm dia for protection of cables or mechanical protection of earth strip laid under plinths/floors, road, paths, culverts, or fixed on walls, or along poles by means of MS clamps with necessary bolts, nuts and washers etc complete all as specified and directed by Engr-in-Charge.
Al as item ser No 16 above but size 50 mm dia.
Al as item ser No 16 above but size 80 mm dia.
Al as item ser No 16 above but size 100 mm dia.
Supply & fixing MCCB TPN 63 Amps 16 KA complete all as specified and directed by Engineer-in-Charge. Make :- Legrand/Havells/L&T/Hagger/Schnider/Indoasian/HPL
All as item ser No 20 above but 100 Amps 16 kA .
All as item ser No 20 above but 125 Amps 415 Volts 16 kA
All as Item ser No 20 but TPN 160 Amps 415 Volts 36 kA .
All as per item No 20 above but TPN 200 Amps 415 volts 36 kA.
All as per item No 20 above but TPN 250 Amps 415 volts 36 kA.
All as per item No 20 above but TPN 400 Amps 415 volts 36 KA.
Supply and fixing LED Post top fitting 40 Watt 5700 K CCT IP 65 powder coated aluminium die cast and spun aluminium with clear diffuser suitable for landscape lighting inclmaking necessary arrangement for mounting fitting as reqd on site and testing complete all as specified and directed by Engr -in-Charge Make cat Part No PGCLPT 01 40 C of Pllycab or equivalent model of Bajaj/Halonx.
M&L for LT/HT pole painting two coated anti corrosive synthetic enamelled silver paint as per existing condition incl rubbing old surface with emery paper alternate black and yellow 30 cm wide strip upto 1.5 mtr of pole above ground level and marking pole numbers complete as directed and specified by engineer in charge.
Clearing surrounding area street lights poles,subs stn, pump house area clear distance required with trimming of tree branches, trunk not exceeding 20cm girth including disposal of trimmed material to a distance of 60 mtr complete all as specified and directed by Engr -in-Charge
Supply and fixing LED Bollard light fitting IP 54 powder coated PDC aluminium body with opal diffuser suitable for landscape lighting incl making necessary arrangement for mounting fitting as reqd on site and testing complete all as specified and directed by Engr -in-Charge Make cat Part No PGR0201003 of Pllycab or equivalent model of Bajaj/Halonx.
Demolition of cement concrete (unreinforced) in ground floor and pavings exceeding 15cm thickness but above ground floors all as specified and directed by Engr-In-Charge.
M&L for PCC 1:3:6 type C-2 using 40mm graded stone aggregate as in foundation for LT pole / foundation mass filling or path/hard standing etc as reqd on site complete all as specified and directed by Engr-In-Charge.
M&L for PCC 1:2:4 type B-2 using 20mm graded stone aggregate for coping of pole using extra cement for smooth finish including form work / foundation mass filling or path/hard standing etc as reqd on site complete all as specified and directed by Engr-In-Charge.
M&L for PCC 1:4:8 type D-2 (Using 40mm grade stone aggregate) as in bed for pole in foundation filling and mass concrete/ foundation mass filling or path/hard standing etc as reqd on site complete all as specified and directed by Engr-In-Charge.
Supply and fix cable jointing kit for 1.1 KV grade cable for straight through joint complete with Jointing material heat Shrink type and accessories suitable for 3 ½ / 4 core XLPE, armoured, Al conductor cable of size 25 to 50 sqmm,Indoor/Outdoor type complete all as specified and directed by Engr-In-Charge.
All as item ser No 35 above but for cable of size 70 to 95 sq mm.
All as item ser No 35 above but for cable of size 120 to 150 sq mm.
All as item ser No 35 above but for cable of size 185 to 240 sq mm
All as item ser No 35 above but for cable of size 300 to 400 sq mm.
M&L for overhauling of battery by disconnecting battery from GI pole and removel of suphation, cleaing of plate and all parts painting of poles Bty box etc with two coats of aluminium silver paints and fill up distil water full as required and testing after reassembling all as directed and specified by Engr in Charge.
Supply and fixing in replacement Battery suitable for Solar light 43 Watt 12 V as per existing specification complete all as specified and directed by Engr-In-Charge.
Supply, Fixing and testing solar street light LED fitting suitable solar light 43 Watt as per existing specification complete all as specified and directed by Engr-In-Charge.
Supply and fixing in replacement Charge controller/drive circuit suitable for solar light upto 43 Watt as per existing specification complete all as specified and directed by Engr-In-Charge.
Supply & Fixing in repair of Four Pole Contactor, 415V AC, 2 NO+NC, Make = GE/Schneider/ABB/Legrand complete all as specified and directed by Engr-In-Charge. (a) 250 Amp
All as per item No 44 but 160 Amps
All as per item No 44 but 100 Amp
All as per item No 44 but 48 Amps
All as per item No 44 but 32 /36Amps
S & F OFF load Change Over Switch 250 Amps 4 pole 415 Volt complete all as specified and directed by Engr-In-Charge. make Havells/L&T/Legrand
Surface cleaning/site clearance n exc 15 cm in depth execept in Sub stations area, trenches,sub station rooms two pole/ foure structure surroundings to make a over all presentable condition all as directed by Eng In charge. (Note : Item will be Executed twice in Contract period for Area cleaning of Sub Stn/Pump houses etc)
M&L for painting of old LT panels of any size and descreption with two coat anti corrosive synthetic enamelled smoke gray paint or as per existing condition required on site incl rubbing old surface with emery paper complete as directed and specified by engineer in charge.
Supply & filling in Bty distil water suitable for Bty Charging any type complete all as specified and directed by Engr-In-Charge. Note : To be carry out twice in contract period
Supply and Fixing including repair/replacement of LED driver 230 volt single phase of 45/48 watt, driver life >= 25000 Hrs efficiency - 85%, with out put short circuit protection all as specified and directed by Engr-in-Charge.Make – Havells/Halonix/Polycab
M&L for taking down/ disconnecting old street light fitting any capacity and deposit to MES yard complete all as specified and directed by Engr-In-Charge.
M&L for LED energy saving and environmental friendly long life versatile pressure diw cast aluminium IP 66 roadway luminaire with high power LEDs and electronic diver complete set of 45 wattage 6000K, with PF-=>0.95, THD-<=10%, driver should be same make as of LED fitting, with operating range of 140 V to 280 V, isolation of driver facility as directed Make - Havells or equevalent in CG/Halonix/Polycab as per site requirment
S & F in replacement of hot pressed moulded SMC boxes with hinged door fixing of size 230 mm x 170mmx105 mm complete with suitable aluminium busbar 4 Nos fixed in side the box Make :- Sintex /Hensel or equivalent model complete all as specified and directed by Engineer-in Charge.
M & L for replacement of cable PVC insulated unarmored for connection 2.5 sqmm x 3 core Copper conductor duly drawn MS conduit 20 mm dia from cut out junction box to street light fittings on poles including PVC flexible pipes complete all as specified and directed by Engineer-In - Charge.
M&L for cross arms (MC 75), bracings, supports, clapms and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one prime coat, one under coat and one finishing coat paint complete all as spoecified and directed by Engr-in-Charge.
M&L for replacement of LED FLOOD light fitting powder coated PDC aluminium body with toughened glass visior of 120 wattage 5700K IP 66 all as specified and directed by Engr in charge. Havells/Hallonix/Philips/Jaquar
M&L for replacement of LED FLOOD light fitting powder coated PDC aluminium body with toughened glass visior of 180 wattage 5700K IP 66 all as specified and directed by Engr in charge. Polycab/Havells/Hallonix/Philips/Jaquar
M&L for replacement of LED FLOOD light fitting powder coated PDC aluminium body with toughened glass visior of 100 wattage 5700K IP 66 all as specified and directed by Engr in charge. Polycab/Havells/Hallonix/Philips/Jaquar
M&L for earthing with galvanized mild steel earth plate electrode 60cmx60cmx6mm thick buried directly in ground (earth pit not less than 2.25 Mtr below ground level) with top edge of earth plate not less than 1.5 Mtr below ground level connected to galvanized strip 32X6 mm by means of nuts, bolts, thimbles, chuck nuts, washers of GI or steel, PCC (concrete chamber) 1:2:4 type B-1 using 20mm graded stone aggregate , internal surface of concrete chamber shall be given 15mm thick plaster in CM 1:4 funnel with wire mesh of 22 gauge (0.68mm) 8 mesh per liner inch, 50 mm thick cover of RCC 1:2:4 type B-1 using 20 mm graded stone aggregate reinforced with 8 mm four MS bars @ 80mm centre to centre both ways and charcoal dust and common salt all as shown in electrical plate No 5 of MES SSR Part-I (1991) and specified including provision of earth strip upto 7.5 Mtrs protected by 40 mm dia medium grade pipe and watering pipe shall be 20mm bore medium grade, all excavation and earth work & connectiing the earthing as specified & directed by Engr-in-Charge.
All as above item No 62 but with earthing lead 25 x 4 mm GI strip complete all as specified and directed as required on site bu engr-in-charge.
S & F Earthing lead 25 x 4 mm GI strip complete all as specified and directed as required on site by engr-in-charge.
All as Item ser No 64 above but earting lead 32 x 6 mm GI strip complete all as specified and directed as required on site by engr-in-charge.
M/S V.D.ENTERPRISES
36SHRI RADHEY ASSOCIATES
KRISHANA ELECTRIC WORKS
M/S Parshant Associates
GARG CONSTRUCTION CO
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .