GEMC-511687782891981
Awarded to MASTER LABS
₹2.3 L
Products
| Product | Brand / Model | HSN | Quantity | Unit Price | Amount |
|---|---|---|---|---|---|
| Digit Multimeter | Fluke 8846a | - | 2 NOS | ₹1.2 L | 233,572 |
Loading…
| # | Company | Offered Item | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹2.3 LQualified Make: FLUKE
Model: Fluke 8846a | Make: FLUKE
Model: Fluke 8846a | L1 | Qualified | |
| 2 | L2₹2.5 L+₹15,428 (6.61%)Qualified Make: FLUKE
Model: Fluke 8846a 506 701 SIDDARTH BUILDING 96 NEHRU PLACE NEW DELHI 110019 | NEW DELHI | NEW DELHI | DELHI | 110019 | Make: FLUKE
Model: Fluke 8846a | L2 | Qualified | |
| 3 | ₹2.3 L E 20 SHAM NAGAR TILAK NAGAR SHAM NAGAR WEST DELHI DELHI 110018 | WEST DELHI | DELHI | 110018 | - | - | - |
Tender Value
Refer Docs
EMD Value
Exempted
Closing Date
24 Aug 2018, 5:00 pmClosed
digital multimeter Digital Multimeter ( 2 ) Technical Specifications * As per GeM Catalogue. Specification Specification Name Values Allowed Values FEATURES Type Benchtop Hand Held
Benchtop Display (Digits) 6.5 6.5 Measurement Type True RMS Average
True RMS Counts 200000 4000
6000
50000
200000 (or higher) MEASUREMENTS DC Voltage Range 600 600
1000 DC Voltage Accuracy 0.005 0.005
0.05
0.1
0.5
1 DC Voltage resolution 0.001 0.001
0.01
1
10
100 AC Voltage Range 600 600
1000 AC Voltage Accuracy 0.08 0.08
1 AC Voltage resolution 0.001 0.001
100 DC Current Range 10 3
10 DC Current Accuracy 0.005 0.005
1.5 DC Current resolution 0.001 0.001
100 1/5 AC Current Range 10 3
10 AC Current Accuracy 0.5 0.5
1.5 AC Current resolution 0.01 0.001
100 Resistance Range 100 40
50
60
100
500 Resistance Accuracy 0.08 0.08
1.5
2
2.5
3
3.5 Resistance resolution 0.001 0.001
100 Capacitance Range ( Micro farad ) .01 to 1000 1 to 100
1 to 200
.01 to 1000
NA Capacitance Accuracy ( % ) 1.5 1.5
3.5
5
NA Capacitance resolution ( nF ) 1 0.001
NA Frequency Range ( KHz ) 300 50
200
300
NA Frequency Accuracy ( % ) 0.1 0.1
NA Frequency resolution ( Hz ) 0.001 0.001
NA Temperature Range ( Degree C ) -40 to 400 -40 to 400
50 to 1000
NA Temperature Accuracy ( % ) 1.5 1.5
NA Temperature resolution ( Degree C ) 0.01 0.001
NA OTHER FEATURES Continuity test and Diode test Available * Data logging Available * If Data Logging Feature is Available
Internal Memory min. 5000 points/200 readings * Computer Interface along with software Available * Dimensions ( mm X mm X mm ) 88 X 217 X 297 mm * Weight 3600 * Other Features 2 x 4 ohms 4-wire measurement technique * SAFETY Safety Rating Category II 600 V of IEC 61010. Category II 600 V of IEC 61010.
Category II 1000 V of IEC 61010.
2/5 Category III 600 V of IEC 61010.
Category III 1000 V of IEC 61010.
Category IV 600 V of IEC 61010
Category IV 1000 V of IEC 61010 Safety Certification UL
CE
CSA
VDE * POWER REQUIREMENTS Power Requirements 230 V +/-10% AC
50 Hz +/- 3% through Adaptor * if Battery Operated
then Type of Battery NA * if rechargeable
then chemistry of the battery NA * if Non-rechargeable
then size of the battery cell NA * number of non- rechargeable the battery/cell NA * Voltage of rechargeable Battery 0 * capacity of rechargeable battery(milli Ampere Hour) 0 * Suitable charger adaptor provided NA * ACCESSORIES Standard Accessories Supplied with the Equipment 6.5 digit Precision Multimeter
24 ppm USB mem Includes: TL71 Test Lead Set
Premium DMM LCI Line Cord USB to RS232 Cable Adapter Statement of Calibration Practices WEEE Information Sheet Warranty Information Programmer
Users and Service Manuals (CD- ROM) FlukeView Forms – Basic for 8845/8846 * WARRANTY Warranty 3 1
5 OPERATING CONDITION Minimum Operating Temperature -20 * Maximum Operating Condition 55 * 3/5 Operating Humidity (RH) 95 * TEST REPORT DETAILS The equipment supplied with calibration certificate YES * conformity to Dry Heat for 16 hrs at a specified maximum temp in accordance with IS:900 0/part-3/section-5/1977 latest true * conformity to Cold Test for 4 hrs at a specified minimum temp in accordance with IS:900 0/part-2/section-4/1977 latest true * conformity to Damp Heat (Cyclic)Test for 2 Cycles of 24 hrs each at a temp of 40 degree C & 95% RH true * Availability of Test Reports from Central Govt/NABL/ILAC approved accredited lab to prove conformity to the specification true * Test Report Number and date for the specification test 369721 25 OCT 2017 * Name and address of the Lab for the specification test NABL * * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Manjunatha K S 560058
Laboratory for Electro-Optics Systems (LEOS) First Cross
First Phase Peenya Industrial Estate 2 15
483197
GEM/2018/B/68296
GeM Contract
digital multimeter
GeM Contract
15 days
Karnataka; Bengaluru Urban
PRODUCT
Awarded to MASTER LABS
₹2.3 L
| Product | Brand / Model | HSN | Quantity | Unit Price | Amount |
|---|---|---|---|---|---|
| Digit Multimeter | Fluke 8846a | - | 2 NOS | ₹1.2 L | 233,572 |
| Item | Delivery Location | Qty | Delivery |
|---|---|---|---|
| digital multimeter Digital Multimeter ( 2 ) Technical Specifications * As per GeM Catalogue. Specification Specification Name Values Allowed Values FEATURES Type Benchtop Hand Held | - | - | - |
| Benchtop Display (Digits) 6.5 6.5 Measurement Type True RMS Average | - | - | - |
| True RMS Counts 200000 4000 | - | - | - |
| 6000 | - | - | - |
| 50000 | - | - | - |
| 200000 (or higher) MEASUREMENTS DC Voltage Range 600 600 | - | - | - |
| 1000 DC Voltage Accuracy 0.005 0.005 | - | - | - |
| 0.05 | - | - | - |
| 0.1 | - | - | - |
| 0.5 | - | - | - |
| 1 DC Voltage resolution 0.001 0.001 | - | - | - |
| 0.01 | - | - | - |
| 1 | - | - | - |
| 10 | - | - | - |
| 100 AC Voltage Range 600 600 | - | - | - |
| 1000 AC Voltage Accuracy 0.08 0.08 | - | - | - |
| 1 AC Voltage resolution 0.001 0.001 | - | - | - |
| 100 DC Current Range 10 3 | - | - | - |
| 10 DC Current Accuracy 0.005 0.005 | - | - | - |
| 1.5 DC Current resolution 0.001 0.001 | - | - | - |
| 100 1/5 AC Current Range 10 3 | - | - | - |
| 10 AC Current Accuracy 0.5 0.5 | - | - | - |
| 1.5 AC Current resolution 0.01 0.001 | - | - | - |
| 100 Resistance Range 100 40 | - | - | - |
| 50 | - | - | - |
| 60 | - | - | - |
| 100 | - | - | - |
| 500 Resistance Accuracy 0.08 0.08 | - | - | - |
| 1.5 | - | - | - |
| 2 | - | - | - |
| 2.5 | - | - | - |
| 3 | - | - | - |
| 3.5 Resistance resolution 0.001 0.001 | - | - | - |
| 100 Capacitance Range ( Micro farad ) .01 to 1000 1 to 100 | - | - | - |
| 1 to 200 | - | - | - |
| .01 to 1000 | - | - | - |
| NA Capacitance Accuracy ( % ) 1.5 1.5 | - | - | - |
| 3.5 | - | - | - |
| 5 | - | - | - |
| NA Capacitance resolution ( nF ) 1 0.001 | - | - | - |
| NA Frequency Range ( KHz ) 300 50 | - | - | - |
| 200 | - | - | - |
| 300 | - | - | - |
| NA Frequency Accuracy ( % ) 0.1 0.1 | - | - | - |
| NA Frequency resolution ( Hz ) 0.001 0.001 | - | - | - |
| NA Temperature Range ( Degree C ) -40 to 400 -40 to 400 | - | - | - |
| 50 to 1000 | - | - | - |
| NA Temperature Accuracy ( % ) 1.5 1.5 | - | - | - |
| NA Temperature resolution ( Degree C ) 0.01 0.001 | - | - | - |
| NA OTHER FEATURES Continuity test and Diode test Available * Data logging Available * If Data Logging Feature is Available | - | - | - |
| Internal Memory min. 5000 points/200 readings * Computer Interface along with software Available * Dimensions ( mm X mm X mm ) 88 X 217 X 297 mm * Weight 3600 * Other Features 2 x 4 ohms 4-wire measurement technique * SAFETY Safety Rating Category II 600 V of IEC 61010. Category II 600 V of IEC 61010. | - | - | - |
| Category II 1000 V of IEC 61010. | - | - | - |
| 2/5 Category III 600 V of IEC 61010. | - | - | - |
| Category III 1000 V of IEC 61010. | - | - | - |
| Category IV 600 V of IEC 61010 | - | - | - |
| Category IV 1000 V of IEC 61010 Safety Certification UL | - | - | - |
| CE | - | - | - |
| CSA | - | - | - |
| VDE * POWER REQUIREMENTS Power Requirements 230 V +/-10% AC | - | - | - |
| 50 Hz +/- 3% through Adaptor * if Battery Operated | - | - | - |
| then Type of Battery NA * if rechargeable | - | - | - |
| then chemistry of the battery NA * if Non-rechargeable | - | - | - |
| then size of the battery cell NA * number of non- rechargeable the battery/cell NA * Voltage of rechargeable Battery 0 * capacity of rechargeable battery(milli Ampere Hour) 0 * Suitable charger adaptor provided NA * ACCESSORIES Standard Accessories Supplied with the Equipment 6.5 digit Precision Multimeter | - | - | - |
| 24 ppm USB mem Includes: TL71 Test Lead Set | - | - | - |
| Premium DMM LCI Line Cord USB to RS232 Cable Adapter Statement of Calibration Practices WEEE Information Sheet Warranty Information Programmer | - | - | - |
| Users and Service Manuals (CD- ROM) FlukeView Forms – Basic for 8845/8846 * WARRANTY Warranty 3 1 | - | - | - |
| 5 OPERATING CONDITION Minimum Operating Temperature -20 * Maximum Operating Condition 55 * 3/5 Operating Humidity (RH) 95 * TEST REPORT DETAILS The equipment supplied with calibration certificate YES * conformity to Dry Heat for 16 hrs at a specified maximum temp in accordance with IS:900 0/part-3/section-5/1977 latest true * conformity to Cold Test for 4 hrs at a specified minimum temp in accordance with IS:900 0/part-2/section-4/1977 latest true * conformity to Damp Heat (Cyclic)Test for 2 Cycles of 24 hrs each at a temp of 40 degree C & 95% RH true * Availability of Test Reports from Central Govt/NABL/ILAC approved accredited lab to prove conformity to the specification true * Test Report Number and date for the specification test 369721 25 OCT 2017 * Name and address of the Lab for the specification test NABL * * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Manjunatha K S 560058 | - | - | - |
| Laboratory for Electro-Optics Systems (LEOS) First Cross | - | - | - |
| First Phase Peenya Industrial Estate 2 15 | - | - | - |
Exempted
17 Sept 2018
20 Aug 2018
contract_GEMC-511687782891981.pdf
GEM_CONTRACT • 0.02 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_483197.pdf
GEM_BID
termsCondition.pdf
OTHER
2657c7ca70287299b5181580fdb5a7ab.pdf
OTHER
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .