| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹41.0 LAccepted-AOC SAI LEELA MAHAVIR COLONY BIRLA HOUSE GOLA KA MANDIR MORAR GWALIOR 474005 | GWALIOR | GWALIOR | MADHYA PRADESH | 474005 | L1 | Accepted-AOC Being lowest bidder | |
| 2 | L2₹42.2 L+₹78,344 (1.89%)Rejected-Finance ANAND BHAVAN GHASMANDI MORAR GWALIOR MP 474006 | GWALIOR | GWALIOR | MP | 474006 | L2 | Rejected-Finance Not lowest | |
| 3 | L3₹49.8 L+₹8.4 L (20.2%)Rejected-Finance | L3 | Rejected-Finance Not lowest | |
| 4 | L4₹51.7 L+₹10.2 L (24.7%)Rejected-Finance | L4 | Rejected-Finance Not lowest | |
| 5 | L5₹53.1 L+₹11.7 L (28.2%)Rejected-Finance | L5 | Rejected-Finance Not lowest |
Tender Value
Refer Docs
EMD Value
₹93,800
Closing Date
12 Jun 2021, 6:00 pmClosed
GE (AF) ADM AREA GWALIOR
AF STATION GWALIOR
SPECIAL REPAIRS TO NO 1 AIRMEN MESS AT AF STATION GWALIOR
2021_MES_435113_1
8996/E8
Open Tender
Civil Works
Item Rate
180 days
AF STATION GWALIOR
AS PER TENDER DOCUMENT
7 documents required · 7 mandatory
₹500
GE AF ADM AREA GWALIOR
₹93,800
Yes
2 Sept 2021
17 Apr 2021
14 Jun 2021
17 Apr 2021
12 Jun 2021
10 May 2021
17 Apr 2021 - 24 Apr 2021
Amount
Demolition of brick work or stone/ boulder masonry, built in cement mortar including all quoins, pillars etc. and segregation serviceable bricks, keep them staking for re use complete all as directed.
M&L for Brickwork with subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius built in cement mortar 1:6 etc,complete all as specified.
S&F Dholpur sand base stone 300 mm wide of thickness 30 mm, laid over and including 20 mm thick screed in cement mortar 1:6 complete all as specified and directed.
S&F Dholpur sand stone jallies 25 to 30 mm thick with cement mortar 1:4, machine cut edge, uniform colour of eac stone jallies of size 3'x2' fixed in between the post, design as approved by GE complete all as specified and directed.
S&F Dholpur sand stone carving post of section not less than 3"x3" of design as approved by GE of length 0.70 M to 1.00 M fixed in base stone by providing a recess for locking arrangement complete all as specified and directed.
S&F for 16 to 18 mm thick Dholpur sand stone cladding, gang saw cut with machine cut edges and of uniform colour, size of each stone not exceeding 0.20 Sqm including making V groove on all sides of stone and drilling hole for hold fastener, rubbing, polishing etc and including silicon treatment, over and including 10 mm thick rendering in cement mortar 1:4 complete all as specified and directed.
Taking down chowkhats or frames with shutters ( without taking off shutters from the frames) of area exceeding 1.50 Sqm but not exceeding 4.0 Sqm each including cutting holes for taking out hold fast or dismantling brick work & removing from site complete all as specified and directed.
Taking down chowkhats or frames with shutters ( without taking off shutters from the frames) of area not exceeding 1.50 Sqm each including cutting holes for taking out hold fast or dismantling brick work & removing from site complete all as specified and directed.
Demolition of PCC in ground floors and pavings not exc 15 cm thickness below or above ground level and removing the debris to a distance not exc 2.5 Km from the starting point. Complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as directed.
M&L 25 mm thick cement concrete 1:2:4 (12.5 mm graded stone aggregate ) type B-0 as in levelling course in floors, complete all as specified.
M&L for Granite of 18mm to 20mm thick (of any type) work (table rubbed/moulding and polished) in steps, jambs, pillars and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite over and including 15mm screed bed in Cement Mortar 1:4 complete all as specified.
M&L for mirror polished machine cut kota stone slab flooring 20-25 mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing and polishing over and including 15mm thick screed bed in cement mortar (1:3) complete all as specified and as directed Note:- The size of kota stone slab not less than 550mmx550mm (cut size except the location where balanced.)
M&L for premium quality non skid, coloured ceramic tiles 7-8 mm thick desined/digital & approved colour (square/rectangular) area of each tiles exc 0.06 but not exceeding 0.11 Sqm in floor etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of coloured tiles over & includind 15 mm thick screed bed or bedding layer in Cement Mortar (1:6) complete all as specified.
M&L for 10mm thick Glazed Vitrified ceramic tiles, light shade (square/rectangular), in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including screed bed or bedding layer of 15mm thick in CM (1:4) for laying floor finishes, area of each tile not exceeding 0.36 Sqm complete all as specified and directed:-
M&L for premium quality non skid, coloured ceramic tiles 7-8 mm thick desined/digital & approved colour (square/rectangular) area of each tiles exc 0.11 but not exceeding 0.18 Sqm in floor etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of coloured tiles over & includind 15 mm thick screed bed or bedding layer in Cement Mortar (1:6) complete all as specified.
M & L for premium quality coluored Glazed ceramic tiles of size 450 x 300 x 7 mm thick designed/digital/ Printed of approved colour, as in vertical surfaces such as skirting, dados etc. set and jointed in neat cement slurry and pointed in coloured cement to match coloured tiles, ver and including 10mm thick screed bed in cement mortar (1:3) complete all as specified.
M&L for 75 mm thick PCC (1:3:6), type C-2, using 40mm graded stone aggregate as in plinth protection, surface finished even & smooth without using extra cement, with and including joint filling complete all as specified and directed.
Supplying, fabricating and fixing of aluminium powder coated (minimum thickness of powder coating shall be 50 micron) for door/ window/ ventilator frames, shutters, partitions etc including necessary jointing cleats, glazing clips, aluminium snap beading having minimum weight 100 gram per RM, rubber neoprane gasket, screws, dash fasteners, rawl plug etc complete all as specified and directed. Note: Only weight of aluminium section shall be measured for payment purpose.
S&F in repair fancy type decorated PVC sheathed GI curtain rod, 20 mm dia, including brackets and fixing arrangement and all other fittings complete all as specified and directed.
S&F for aluminium grills of size exc 5mm x 7.5mm and aperture n. exc 80mm incl fixing with aluminium channel 1mm thick with stainless steel screw and tint match with existing complete all as specified.
S&F powder coated aluminium barrel tower bolts of extruded section of size 200mm complete all as specified and directed.
S&F powder coated aluminium handles cast type of size 150mm complete all as specified and directed.
S&F double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty and fixed complete all as specified and directed.
Supply Only 6.30 mm thick sheet glass ordinary quality, frosted one side for aluminium doors/ partitions etc complete all as specified and directed.
Supply Only 4.80 mm thick plain sheet glass ordinary quality, for aluminium windows/ ventilators etc, in square not exc 0.50 Sqm each pane complete all as specified and directed.
S&F stainless steel wire cloth, 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with tinned tacks, or stainless steel wire staples etc. in wooden door / window, completed all as specified and directed.
S&F in repair mild steel mortice lock, 100 mm in size, double handle, vertical type, 06 levers for door complete all as specified and directed.
S&F pressed steel frames made out of 1.25mm thick mild steel sheets for door with one or more rebates including necessary fixing lugs, hinges, lock strike plate etc including one shop coat of red oxide primer including cutting holes and making good in PCC 1:2:4 type B-1 using 20 mm graded stone aggregate, of size 105x60 mm complete all as specified and as directed:- Note : 10mm deformed bar shall be provided in bottom portion in each frame. The rate for the same is included in rate quoted against this item.
S&F pressed steel frames made out of 1.25mm thick mild steel sheets for door with one or more rebates including necessary fixing lugs, hinges, lock strike plate etc including one shop coat of red oxide primer including cutting holes and making good in PCC 1:2:4 type B-1 using 20 mm graded stone aggregate, of size 165x60 mm complete all as specified and as directed:- Note : 10mm deformed bar shall be provided in bottom portion in each frame. The rate for the same is included in rate quoted against this item.
M&L for PCC (1:3:6) type C0 (using 12.50mm graded stone aggregate) as in back filling of door frame/ hold fast etc complete all as specified and directed.
Fixing only mild steel butt hinges of size 100 mm, medium weight, cold rolled mild steel complete all as specified and directed.
S&F solid PVC door frame of size 50x47mm made out of 5mm wood grain printed PVC sheet reinforced with MS Square tube fixed with 75mm long MS screws with PVC fasteners to wall all including painting edges to match with printed sheet and repair of james of wall & finishes as required complete all as specified and directed .
S&F factory made solid panel PVC door shutter 30mm thick (Style) consisting of frame made out of MS tubes for top, bottom and side rails, MS frame shall be covered with heat molded plain colour PVC “C” channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and both side prelaminated PVC sheet, stiles and rail feathered at edge for top rail lock rail & bottom rail on either side and as gap insert for top rail and bottom rail paneling of plain colour PVC sheet to be fixed in the MS frame welded /sealed to the stiles and rails with suitable PVC sheet beading and jointed together with solvent cement and fixing in the frame at site complete all as specified and directed.
All as per item No. 34 here-in-before but wire gauze shutter. The wire shall be wrapped on additional square 8 mm mild steel solid tube and this tube shall be welded to MS tubes. The wire gauze shll be stretched to tighten firmly complete all as specified and directed.
S&F anodised aluminium sliding door bolt with hasp, staple ( bolt type ) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections of size 300mm complete all as specified and directed.
S&F 250mm mild steel helical door springs fixed by welding to steel frame or by screwing to wooden frame complete complete all as specified and directed.
S&F anodised aluminium barrel tower bolts of extruded section of size 150mm complete all as specified and directed.
S&F 100 mm long butt hinge, extruded aluminium alloy with galvanized mild steel hinge pin, powder coated of required tint to match shutter and fixed, type C-21 complete all as specified and directed.
S&F anodised aluminium handles cast type of size 150mm complete all as specified and directed.
S&F in repair 18mm thick solid UPVC ply of 1st quality of one side prelaminated of approved colour and one side white colour fixed with screwes, solvent cement /adhesive to make cup board shutters and like complete all as specified and directed. [Make :- Rajshree/Sintex/Polycon]
S & F continuous (Piano) hinges ,mild steel, bright finished or electrogalvanised, width of flap 30 mm (when open), complete all as specified and directed.
S&F 125 mm long, Hasp and staple, safety type, brass with mild steel hinge pin including bolt to hinge plate and fixed with screws, complete all as specified and directed.
Taking down old cement / lime plaster on brick or concrete surfaces etc including racking out joint, hacking for key screbbing down with water etc.complete all as directed.
M&L for 15mm thick rendering on brick work or concrete surface on wall in cement mortar 1:6 finished even and smooth without using extra cement complete all as specified.
M&L for 15mm thick rendering cement plaster in Cement Mortar 1:4 on fair faces of brick work or concrete surface, mixed with water proofing compound as per manufacturers instructions, finished fair & even without using extra cement complete al as specified. Note: Water proofing compound shall be measured and paid separately under respective item of BOQ.
Supply only integral water proofing compound complete all as specified and directed.
M&L for 5 mm thick rendering on fair faces of concrete surfce in Cement Mortar (1:3) as in ceiling finished even and smooth without using extra cement as in ceiling complete all as specified.
M&L for preparing newly plastered or unplastered surfaces of wall and applying two coats of oil bound distemper over and including one coat of primer and a thing layer of JK/ Birla wall care putty complete all as specified and directed.
M&L for preparing newly plastered or unplastered surfaces of wall and applying two coats of exterior emulsion paint (Ace paint from Asian Paints or other equivalent brand from Berger/ Shalimar Paints) over and including one coat of primer and a thing layer of JK/ Birla wall care putty complete all as specified and directed.
M&L for removal of complete existing treatment from old deoreted surfaces of walls and preparing surfaces by rubbing/ sanding and applying two coats of exterior emulsion paint (Ace paint from Asian Paints or other equivalent brand from Berger/ Shalimar Paints) over and including a thin layer of wall care putty and one coat of suitable primer complete all as specified and directed. Make wall care putty : Asian/JK/Birla
M&L for removal of complete existing treatment from old deoreted surfaces of walls and preparing surfaces by rubbing/ sanding and applying two coats of oil bound distemper over and including a thin layer of wall care putty and one coat of suitable primer complete all as specified and directed. Make wall care putty : Asian/JK/Birla
M&L for preparation of old decorated surfaces of ceiling including cornices, plastered or unplastered surfaces by brooming down or steel wire brushing to remove dust, dirt and loose scales of lime wash and other foreign material, scrapping down, smoke soot, moulds, ,ass and effloresent salts and treating out greasy spots and applying two coats of white wash, complete all as specified and directed.
Dismantling old plain or corrugated Asbestos cement sheeting in roof coverings etc and remove materials from site of work complete all as directed.
M&L for Pre-painted galvalume alu. Zinc coating GI based corrugated steel sheet 0.50 mm thick (total coated thickness) of any colour having tensile strength 550 M pa minimum yield strength as in roof covering fixed using hot dip galvanized self drilling and self tapping screws neoprene and EPDM washers. (Note : minimum, yield strength 550 Mpa with hot dip alloy of 55% Aluminium, 43.5 %zinc, 1.5% Silicon and finished with resin coat on both surfaces)
M&L for applying two coats of synthetic enamel paint over a coat of red oxide primer including preparation of new steel/iron surfaces exceeding 10cm width or girth.complete all as specified
S & F in repair Vitreous china counter top wash basin , white, of size 550 x 400 mm including 32 mm dia brass waste coupling, fittings and PVC waste pipe complete all as specified and as directed.
S & F fancy type pillar tap 15 mm dia, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered 'hot' or 'cold' with long screwed shanks and fly nuts, screwed for iron pipe and fixed, complete all as specified and as directed.
Taking up or down 15mm bore steel tubing and connections, including seggregation serviceable pipes cleaning for re-fixing or removal unserviceable pipes from site complete all as specified and directed.
Taking up or down 20mm bore steel tubing and connections, including seggregation serviceable pipes cleaning for re-fixing or removal unserviceable pipes from site complete all as specified and directed.
Taking up or down 25mm bore steel tubing and connections, including seggregation serviceable pipes cleaning for re-fixing or removal unserviceable pipes from site complete all as specified and directed.
Re-fixing of old steel GI tubing, 15mm bore and connections in new or old position (walls, ceiling, floors etc) with and including all new fittings complete all as specified and as directed.
Re-fixing of old steel GI tubing, 20mm bore and connections in new or old position (walls, ceiling, floors etc) with and including all new fittings complete all as specified and as directed.
Re-fixing of old steel GI tubing, 25mm bore and connections in new or old position (walls, ceiling, floors etc) with and including all new fittings complete all as specified and as directed.
S&F GI tubing 15mm dia bore medium grade with and including all fittings ISI marked and fixed to wall, floor and ceiling etc complete all as specified and as directed.
S&F GI tubing 20mm dia bore medium grade with and including all fittings ISI marked and fixed to wall, floor and ceiling etc complete all as specified and as directed.
S&F GI tubing 25mm dia bore medium grade with and including all fittings ISI marked and fixed to wall, floor and ceiling etc complete all as specified and as directed.
S&F 5mm thick beveled edge best quality looking mirror of size 600x450 mm with 30 mm PVC beading all around the glass, mounted over 3mm thick PVC sheet or 4mm thick AC bldg board, complete all as specified and directed.
S&F 5.50mm thick beveled edge best quality looking mirror of size exc 0.60 Sqm but not exc 1.00 Sqm, fixed on wall 30 mm PVC beading all around the glass, mounted over 3mm thick PVC sheet or 4mm thick AC bldg board, complete all as specified and directed.
Disconnecting existing water storage tanks of capacity exc. 500 Ltr but n. exc 1000 Ltrs each for repair works and refixing the same tanks in the same postion after the reapir works is carried out complete all as directed. (Note :- The work also includes making the connections of tanks leak proof by replaceing the damaged /rusted GI fittings, refixing of float valvaus and like).
S&F rotational moulded polythene water storage tank of capacity 1000 litres (Cylindrical/vertical with closed top), double layer construction, ISI marked, hoisted & fixed in position with and including light grade over flow pipe 450mm, waste pipe 600mm long with fitting etc. including of 20 mm dia, ball/ float valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball, 20mm bore minimum weight 210 gms including dismantling / taking out of old water tank of capacity of exc. 250 litres but not exc. 500 & removing to where directed complete all as specified and as directed.
S&F rotational moulded polythene water storage tank of capacity 500 litres (Cylindrical/vertical with closed top), double layer construction, ISI marked, hoisted & fixed in position including light grade over flow pipe 450mm, waste pipe 600mm long with fitting etc. including of 20 mm dia, ball/ float valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball, 20mm bore minimum weight 210 gms including dismantling / taking out of old water tank of capacity of exc. 500 litres but not exc. 1000 & removing to where directed complete all as specified and as directed.
S&F in repair gunmetal globe or gate valves, 20 mm bore, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed.
S&F in repairs WC squatting pan “Orissa Pattern” of size 580 x 440mm white with integral foot rest and 'S' or 'P' traps (excluding flushing cistern & flush pipe) including connection to trap and to flush pipes etc and lime concrete bedding complete all as specified and directed.
Supply and fix in repair PVC flushing cistern 10 ltr capacity valve less syphonic action type low level with and incl ball valve float & handle, waste pipe & brackets complete set complete all as specified and directed.
Supply only flush pipe of PVC, 32 mm dia for low level flushing cistern complete all as specified and directed.
S&F chromium plated brass tubular towel rail, 20mm dia, D type, 60 cm long between flanges complete all as specified and directed.
S&F vitreous china urinal half stall type urinal complete including providing and fixing plugs bedding urinal against wall in CM 1:2 securing urinal to plugs with & including 60 mm brass screws pointing around urinal back in cement fixing automatic flushing cistern with brackets flush pipe grating and union for discharge pipe complete all as specified and directed.
S&F in repair of fancy type overhead shower of 125 mm size with arm swivel joint chromium plated screwed down of 15mm bore complete all as specified and directed. Make: Prayag/ Jaquar/Hindware
S & F in repair Bib taps, 15 mm dia, cast copper alloy, fancy type, long body, chromium plated, screwed down , screwed for iron pipe or for brass ferrule and fixed, complete all as specified and as directed.
S & F in repair fancy type angle stop cock, 15 mm dia, cast copper alloy, with chromium plated, screwed down , high pressure, with capstan head, screwed both ends for iron pipe or for unions and fixed, complete all as specified and as directed.
S&F in repairs PVC connections 15mm size of PTMT of 450mm long. complete all as specified and directed.
S&F PVC (SWR) floor trap, out let dia 100 mm, plain with grating including jointing with solvent complete all as specified and as directed.
S&F in repair sinks with drainage board made of stainless steel 1mm thick kitchen or laboratory with plugs, washers and waste; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm bowl size 410mm x 330mm x 160mm, complete all as specified and directed.
Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for and removing the debris to a distance not exc 2.5 Km from the starting point complete all as specified and directed.
M&L for formwork for rough finish to chullah hoods, chajjas, troughs and similar items including edges complete all as specified and directed.
M&L for mild steel TMT bars 6 to 10mm dia bars as in stirrups cut to length, bent to shape required including cranking, bending hooking ends and binding with mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
M&L for mild steel TMT bars as in reinforcement, 10mm dia and over cut to length, bent to shape required including cranking, bending hooking ends and binding with mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
M&L for RCC 1:1.5:3 mix, Type A1 (using 20 mm graded stone aggregate) as in Chajjas, lintels, shelves, fins, fascias and like complete all as specified and directed.
M&L for 50 mm thick louvres and jallies of precast cement concrete (1:2:4) type B0 (12.5mm graded aggregate), measured solid, including all mouldings but excluding frame (Pre cast frame shall be measured separately) set in CM (1:4) complete all as specified and directed.
Demolition of cement concrete of any description and in any position not otherwise specifically provided for and removing the debris to a distance not exc 2.5 Km from the starting point complete all as specified and directed.
M&L for PCC 1:2:4 mix, type B1 (using 20 mm graded stone agg) as in lavelling course to maintain true roof slope, finished even and smooth without using extra cement complete all as specified and directed.
M&L for 10mm thick screed bed or bedding layer in CM (1:3) mixed with water proofing compound as per manufacturers instructions on concrete roof surface finished fair and even to maintain the proper slope of roof surface etc complete all as specified and directed. Note: Water proofing compound shall be measured and paid separately under respective item of BOQ.
Supply only WPC integral water proofing compound complete all as specified and directed.
M&L for roof treatment with APP based polymeric membrane, 3mm thick (minimum), weighting 3.5 Kg/Sqm reinforced with polyester non woven fabric (weighing not less than 160 gms/sqm) shall be applied over and including applying one coat of hot blown bitumin grade 85/25 confirming to IS-702 @ 1.2 kg per Sqm over a coat of bituminous primer @ 0.3 litre per sqm surface, application of APP modified membrane shall be by torch application. The overlaps shall be minimum 100mm on the transverse direction and 75 mm on longitudinal direction complete all as specified and directed.
M & L for cement concrete type B1 1:2:4 (20mm graded stone aggregate ) on roof kerbs and like rounded or chamferred on edges etc, complete all as specified.
M&L for preparing newly plastered surfaces of wall and applying two coats of white wash complete all as specified and directed.
M&L for POP ceiling by 15 mm thick plaster of paris finishing 10 mm thick lathing and 5 mm thick on ceiling using wire mesh, 0.63 mm nominal dia and aperture 1.40 mm including dome or one step inside the ceiling design as approved by the Geon GI frame work of grid size 605x605 mm for seamless ceiling comprising of GI perimeter channel 0.55 mm thick with two unequal flanges of 20 mm and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/ intermediate channel 0.90 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900mm centre to centre with GI cleat and steel expansion fasteners with and including ceiling section (not exc 1.20 M length) of 0.55 mm thickness having kurled web of 50mm and flange of 26 mm each with lips of 10.5mm fixed to intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre including hangers 6 mm dia GI (upto 1200 mm length) adjusting level fixed to roof slab by means of ceiling cleats made out of GI flat 40x3 mm size 60 mm long and expansion hold fasteners 12.5 mm dia 40 mm long. A triangular design of size 7.5CM x 7.5CM is also to be made with plaster of paris along all the wall under ceiling at junction point of ceiling with wall and applying to the entire ceiling and design with two coats of plastic emulsion paint over a coat of primer complete all as specified and directed.
Taking down eaves gutters and rain water pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fittings and accessories) complete all as specified and as directed.
S&F PVC (SWR) pipes single socketed in any length with rubber ring joints and laid in trenches or in floor of size 110 mm bore complete all as specified and as directed.
S&F PVC (SWR) pipes single socketed in any length with rubber ring joints and fixed to wall of size 110 mm bore complete all as specified and as directed.
S&F PVC (SWR) bends any radius including necessary cutting in brick wall and making good to match with existing surface of size 110mm bore complete all as specified and as directed.
S&F PVC (SWR) junction single, (single T) equal or unequal of size 110 mm bore complete all as specified and as directed.
Taking down old unserviceable aluminium partitions with glass panel or sheet panel complete all as specified and directed.
S&F stainless steel grating of 100 mm dia fixed in position with white cement complete all as specified and directed.
S&F 0.63 mm thick aluminium sheet on crumple joint and fixed in position with wooden planks and screws complete all as specified and directed.
Taking down carefully existing unserviceable aluminum point wiring of any description & in any position with and including pvc/steel conduit all fitting, accessories & fixtures such as switches, ceiling roses, pendants, regulators, socket, light fittings call bell, lamp holders etc and making good the disturbed surface of walls, floors, ceiling etc to match with the existing surfaces complete all as directed. NOTE: Old fittings/fixtures/accessories like switch, sockets, lamp holders, regulators etc found in serviceable condition shall be removed carefully for reuse in the work and shall be paid for separately under appropriate item of Schedule `A’.
Material and labour for point wiring for one light point or one fan point controlled by one switch with using 1.5 Sqmm (nominal area) stranded copper conductor cable FR, single core, PVC insulated & unsheathed cable, 1100 volts grade in and including concealed PVC conduit (Medium grade) of suitable size not less then 20mm dia all as directed with using new sunken type pressed steel box/terminal boxes of suitable size, 2mm thick duly painted with one coat of red oxide primer and two coats of black bituminous paint for mounting fittings/junction boxes with and including all accessories and using 1.5 Sqmm (nominal area) stranded copper conductor cable FR single core. PVC insulated & unsheathed cable as in earth wire connected to common earth dolly complete all as specified and directed.
NOTE : (i) The quoted rates shall be deemed to be inclusive for cutting chases in wall/pillars/columns etc. of any description for concealing the conduits to required depth & making good the disturbed surface in cement mortar 1:4 including finishing the surface to match with the existing colour of surface. The portion of point wiring at ceiling shall be in surface conduit of suitable size fixed on ceiling surface with using PVC rawl plugs and provision of 8covering sunken boards/terminal boxes / junction boxes of any shape and size with 3mm thick laminated sheet fixed with suitable GI screws and cup washers) (ii) Fittings like switches, sockets, regulators, lamp holders, light fittings shall be measured and paid for separately under appropriate item of BOQ (Make of Cable/wire:- : Havells /Finolex/Polycab Make of PVC Conduit:-Finolex/Ess Ess Kay Engineering, Make of Laminated Sheet:-/Hylam/National)
All as per item No 108 hereinbefore but point wiring for 5 pin switch socket outlet combination, 5/6 Amps on independent board.
All as per item No 108 hereinbefore but point wiring for one 5 pin socket outlet, on same board .
All as per item No 108 hereinbefore but point wiring for one six pin socket outlet, 15/5 Amps (independent board) controlled by one switch with using 2.5 Sqmm (nominal area) stranded copper conductor.
M & L for switch flush type single pole one way 5 Amps, 240 volts, white ivory finish complete all as specified. (Make :- Anchor(Panta)/ Cona/ Leader)
Fixing only old retrieved switch flush type single pole one way 5 Amps, 240 volts, white ivory finish complete all as specified.
M&L for socket outlet 2 in 1, 5 pin, 6 Amps flush type white ivory finish complete all as specified. (Make :- Anchor(Panta) , Cona , Leader)
S&F switch socket combination multi purpose, 5 Pin 6 amps, flush typeWith Indicator complete all as specified and directed.Make:-Cat part No 2216 of cona or equivalent of Leader/ Anchor(Panta).
Fixing Only old retrieved switch socket combination multi purpose, 5 Pin 6 amps, flush typeWith Indicator complete all as specified and directed.
S&F for switch socket combination multi purpose, 6 Pin 6/16 amps, flush typeWith Indicator complete all as specified and directed. Make:-Cat part No 2711 of cona or equivalent of Leader/ Anchor(Panta).
Fixing Only old retreived switch socket combination multi purpose, 6 Pin 6/16 amps, flush typeWith Indicator complete all as specified and directed.
M&L for ceiling rose surface Bakelite three terminal, 18 x 50 mm complete all as specified. (Make :- Anchor(Panta) , Cona , Leader)
Fixing Only old retreived ceiling rose surface Bakelite three terminal, 18 x 50 mm complete all as specified. (Make :- Anchor(Panta) , Cona , Leader)
M&L for lamp holder insulated body with back plate for batten fitting complete all as specified. (Make :- Anchor(Panta) , Cona , Leader)
S&F for step type electronic fan regulator single phase ,230 volt, 100/120 watt . Complete all as specified. (Size of PT switch ) Make:-Cat part No 3211 of cona or equivalent of Leader/ Anchor(Panta).
Supply & Fix for decorative slim linear LED T5 AL Batten Tube Light 01x20 watt light with co extruded polycarbonate body, environmental frendly, energy efficient ready to use pack with all accessories and connecting the same to ceiling rose with using copper conductor 23/0.0076 flexible PVC sheathsd and fixing arrangement for fixing the light fitting to wall/ roof surface complete all as specified. (Make-Havell's Cat Part No LUMILINEBS20WLED865SPCWH/Surya Cat No -SLEBT -20 /CG cat No -LCTL 18 CDL)
S&F for LED bulk head fitting 10 watt energy saving new generation IP 65 luminatre with opel diffuser complete with lamp all as specified. (Make-Havell's Cat Part No-HEXAFT10WLED857SSYMBOPC/Surya cat Part No -SLE BH-10/ CG Cart Part No -LBHP-10 CDL)
S& F for Street light fittings 1x15watt new generation energy saving & environmental friendly long life versatile pressure die-cast aluminium IP65 roadway luminaire with high power LED as light source with acrylic cover suitable for pole dia O 40mm(Max) with complete (40 mm GI pipe light grade ),clamp,nut-bolt and washer. Complete all as specified. ( Make : Havells Cat part No - ENDURAPEARLSL15WLED757SASYTOPC /Surya Cat Part No -SLRUL 15W IP 66LXN/CG cart part No -LSTS-15CDL.)
Dismantling & Taking out MCB DBs any size , any type and capacity and remove materials from site of works. Complete all as directed.
S&F for sheet metal enclosure Double door for DB’s 8 way 240 volts with 200 Amps rated bus bar for single phase and neutral supply complete fixed properly on in concealed position and to connect their incoming/outgoing electric connections by means of suitable sizes of lugs/thimbles and to provide required sizes of flexible conduit at any open surfaces near DB’s of cables/wires. Complete all as specified. (Make;ABB,Schneider,Legrand)
S&F for factory made epoxy powder coated distribution board TP & N 4 ways (VTPN MCCB DB) with metal door (IP-43 protection) fabricated from minimum 1.6mm thick CRCA sheet and fixed flush to wall and suitable for universal mounting and including 200 Amps copper bus bar, neutral bar, strandard DIN rail, earth bar and cable ties for cable management, top and bottom removable gland plates with Knockouts and suitable for one TPN-MCCB 100 /125 Amps as incomer and 12 SP MCBs (or any combination of SP/TP MCBs )outgoings complete all as specified . (Make;-Legrand Cat No 507720 or equivalent of ABB/Schneider)
S&F for MCB single pole 6 to 32 Amps, "C" Curve ,240 Volts complete all as specified (Make:Legrand/ABB/Schneider )
S&F for MCB Single pole and neutral 40 Amps 10 KA, 'C' series, 240 Volts complete all as specified. (Make:Legrand/ABB/Schneider )
S&F for MCCB, 3 pole, 125 Amps, 50Hz, 415 Volts with rupturing capacity 35/36 KA with thermal magnetic release and adjustable overload setting having type DPX 125 conforming to IEC-609472 & IS-139473 to be fixed in distribution board, complete all as specified. (Make :-Legrand Cat No 4200 86 or equivalent of ABB/Schneider)
Re-fixing only Retreaved servicabale MCB SP, SPN and TPN any size any capacity obtained from dismantling / taking down items. Complete all as directed.
M&L for sub main wiring using two single core PVC insulated, unsheathed stranded copper conductor cable FR of size 4.0 Sqmm of voltage rating upto and including 1100 Volts grade in and including concealed PVC conduit, med grade of size not less then 20 mm bore along-with one run of PVC(green colour) insulated , unsheathed, stranded copper conductor of size 4 Sqmm as earth continuity conductor cable FR all as specified and directed including taking down old submain wiring with any type of conduit. Complete all as specified. (NOTE : Two run of single core PVC cable with one run of earth conductor and conduit shall be measured as one unit.) incl taking out old sub main wiring with any type of conduit.
All as per item No 133 hereinbefore but 6 Sqmm and 6 Sqmm earth wire with PVC conduit 25mm dia med grade complete all as specified and directed.
M&L for single pole and neutral enclosure with a two pin and earth plug and socket complete in metal clad board (Industrial type) with one single pole MCB of capacity 20 Amps, 240 Volts complete fixed on wall by provisioning of suitable sizes of MS strips, nuts, bolts and washers all as specified. (Make:ABB/Schneider/Legrand)
Taking down carefully ceiling fan/exhaust fan including electric connection complete from site and re-fixing the same in existing position after civil work with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed.
Taking down carefully Water heater (Geyser,s) any capicity any size and disconnecting all electric conection including hot & cold PVC water connection and refixing the same and connecting electric & water connection after the civil work. Complete all as directed.
M&L for earthing complete with MS Galvanised earth plate electrode 600 x 600 x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of plate not less than 1.5 mtr below normal ground level including necessary excavation, earth work ,charcoal, salt etc and connected to GI earthing lead wire 4 mm dia by means of GI bolt nuts check nuts washers etc and 20 mm dia GI light grade watering pipe with funnel, wire mesh etc including PCC (1:3:6) type C-1 using 20 mm graded stone aggregate earth pit with 40x40x6 mm mild steel angle iron frame, RCC cover (1:2:4) type B-0, 50 mm thick reinforced with 8 mm dia round bar @100 mm centre to centre both ways with mild steel handle 12 mm dia, plastering 12 mm thick in cement mortar (1:6) internally and upto 150 mm below ground level externally, and GI earth lead wire 4 mm dia and 15 mm dia GI protection pipe medium grade from earth plate to test point upto 7.5m length all as shown in electrical plate No 3 of SSR Part -I 2009 and connected to earth test point including testing complete all as specified & directed. Note: Earth strip and protection pipe upto and including 7.5m deemed included in unit rate quoted by the contractor.
S&F in replacement 36W LED recess softline luminaire suitable for armstrong/grid ceiling with high brightness LEDs and PMMA extruded diffuser giving glare free light and good aesthetic appeal. Fixture size 595x595x70mm complete with LED tube and all accessories specified. (Make : Havells cat part No PLUTONEO2X2PLR34WLED840S/Surya Cat No- SLEFP36R 22/ CG Cat Part No -LCTLSN36- CDL.)
S&F LED doen light, IP55, surface mounted LED down light, in Engineering plastic housing with clear prismatic diffuser, 6W LED complete with lamp etc and all accessories prewired including connecting up with twin core twisted flexible copper conductor cable with suitable size upto ceiling rose including taking down existing light complete all as specified and directed. Make: C&S/ Havells/ CG/ Surya
S&F for LED mirror light complete with lamp all as specified. (Make : Havells Cat part No LUMILNEBS9WLED865SPCWH/Surya Cat part No -SLE-BT-10/ CG Cat part No -LCTL-9 CDL)
NOTE:- Site clearance of materials- All demolished material obtained from dismantling/demolition items shall be deposited at place shown by Engr-in-charge properly spread and levelled and site to be cleaned to the entire satisfaction of Engr-in-charge otherwise panel recovery to a sum of Rs. 10000.00 be deducted from dues without any prior intimation.
M/s Anjali Construction
Lall Electronics
M/s Sagar Construction
M/S LAKSHYA CONSTRUCTIONS
M/S Rajeev Construction
m/s vikash Engineers
M/s Manish Contractor
RAVINDRA SALES
M/s Bijender Singh
lodhi builders
Achal Construction
stage.html
html • 0.08 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .