Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹22.2 LAccepted-AOC SALGAONKAR HOUSE DRIVERS HILL VASCO DA GAMA GOA 403802 | SOUTH GOA | GOA | 403802 | L1 | Accepted-AOC Accepted | |
| 2 | L2₹27.9 L+₹5.6 L (25.3%)Rejected-AOC PAYYOOR KOTTARATHI HOUSE POST AMAYUR KOPPAM PALAKKAD KERALA 679303 | PALAKKAD | KERALA | 679303 | L2 | Rejected-AOC Rejected | |
| 3 | L3₹28.4 L+₹6.1 L (27.4%)Rejected-AOC | L3 | Rejected-AOC Rejected |
Tender Value
Refer Docs
EMD Value
₹50,000
Closing Date
30 Oct 2020, 5:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE GOMANTAK
GE GOMANTAK VASCO DA GAMA GOA 403802
PRE MONSOON MAINTENANCE TO CERTAIN BLDGS AT ZONE A AND B UNDER AGE BR II IN GE GOMANTAK VASCO
2020_MES_383105_1
8165/E8
Open Tender
Support/Maintenance Service
Item Rate
180 days
VASCO DA GAMA
As per tender documents
8 documents required · 8 mandatory
₹500
Yes
GE GOMANTAK
₹50,000
Yes
16 Nov 2021
3 Oct 2020
31 Oct 2020
3 Oct 2020
30 Oct 2020
13 Oct 2020
60 days
Amount
Taking down cement plastering on brick or stone walls including raking out joints hacking for key scrubbing down with water etc inside shafts all as directed by Engr-in-Charge.
Material and Labour 15 mm thick plastering in CM 1:4, on fair faces of stone masonry surfaces finished even and smooth, including mixed with water proofing compound as per manufacturers instructions) on wall of shafts all as directed by Engineer-n-Charge. (Note : Water proofing compund shall be measured and paid separately)
M&L for applying two coats of Anti fungal painting over a coat of primer to match the existing colour including preparation of newly plastered surface of wall all as specified.
Taking down existing treatment along with PCC padding of any thickness and roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust etc complete.
Material and Labour for repair to cracks by cutting by machine, chasing pinning in on brick walls and making good to facing where required and pointing in CM 1:3 with water proofing compound not exc 10 CM girth, in 'V' shape as directed by Engr in Charge.
M & L PCC 1:2:4 type B-0 (using 12.5 mm graded crushed stone aggregate) mixed with and including integral waterproofing compound in cement as per manufacturer's instructions as in padding on roof surface for correcting / making proper slope on roof, surface finished fair and even without using extra cement complete all as specified & directed by Engr-in-Charge.
Material and labour for rendering 10 mm thick on brick or concrete surfaces in CM 1:4 finished even and fair with out using extra cement. including mixed with water proofing compound as per manufacturers instructions) on concrete surfaces all as specified and directed by Engineer-n-Charge. Note : Water proofing compund shall be measured and paid for separately
Suppy only liquid water proofing Compound
M&L for laying water proofing treatment using 4mm thick APP modified membrane consisting fiver layers membrances with features as specified weighing not less than 3.5 kg per sqm reinforced with non woven polyester fiber @ 160gm/Sqm laid over a coat of cold applied bituminous primer @ 0.40 kg/sqm by torching the membrance and sealing the over lap by 100mm length side and 150mm width side all as per manufacturer instructions including joints and changes in direction be curved with cement mortar 1:3 mixed with SBR latex @ 200 ml/bag of cement curved well before laying membrance, all as per manufacturer's instructions and as directed by Engr-in-Charge. Note: (i) Irrespective of lap the net covered area shall only be measured for payment. (ii). Rate is inclusive of APP membrane, SBR Latex (iii) Applying a coat of bituminius aluminium paint @200 gm /sqm (minimum ) in two coats.
Material and Labour for cleaning of bushes/plants/vegetations on walls/roof/chajjas/ceilings and removing/digging out the roots filling the hole and including applying antigrowth chemical and making good surfaces with cement concrete type, B1, 1:2:4, using 20 mm graded stone aggregate all as directed by Engr-in-Charge.
Disconnecting existing tanks Exc 250 & n exc 500 capacity , setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position all as directed by Engr-in-Charge.
Disconnecting existing tanks Exc 500 & n exc 1000 , setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in positionall as directed by Engr-in-Charge.
Dismantling of PVC existing water tank of exc 500 ltrs & n. exc 1000 ltr capacity and removing from site
Dismantling PVC water tanks Exc 250 ltrs & not exceeding 500 ltrs capacity and removing from site
S & F 1000 Ltrs capacity rotational moulded polyethylene water storage tanks, (cylindrical vertical with closed top) hoisted and fixed in position, all as specified in SSR part I-1991and complete.
S & F 500 Ltrs capacity rotational moulded polyethylene water storage tanks, (cylindrical vertical with closed top) hoisted and fixed in position, all as specified in SSR part I-1991complete.
Taking up or down 20 mm dia steel tubing and connection including cleaning for re-fixing or removal from site complete all as specified and directed
All as per item No 17 here-in-before but 25 mm dia.
Refixing old 20mm dia steel tubing and connection in new or old positions (walls, ceilling, floors etc.)
Refixing old 25mm dia steel tubing and connection in new or old positions (walls, ceilling, floors etc.)
Supplying,& fixing, jointing and testing galvanised 20mm dia steel water tubing medium grade with all fittings such as bend, elbow, socket reducer etc fixed to walls and ceilings or laid in floors, complete all as specified and directed
Supplying and laying of 20 mm dia. CPVC pipes SDR 11 & Plain CPVC SDR 11with all fittings on walls/ceiling or laying in floors complete all as specified.
Supplying and laying of 25 mm dia. CPVC pipes SDR 11 & Plain CPVC SDR 11 with all fittings on walls/ceiling or laying in floors complete all as specified.
Supply & Fixing in repair Ball brass valves20mm dia , high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed all as directed by Engr-in-Charge.
Supply & Fixing in repair Ball brass valves 25mm dia , high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed all as directed by Engr-in-Charge.
S&F PVC (SWR) 110 mm dia pipe in repair for roof drain pipe and fixed to wall with bracket including proper packing with CM 1:3
S & F in repair PVC (SWR) bend, 110mm dia complete all as specified and as directed by Engr-in-charge.
S & F in repair PVC sintex cover for 500 ltr / 1000 ltr PVC tank complete all as specified and as directed by Engr-in-charge.
S & F in repair PVC sintex cover for 300 ltr PVC tank complete all as specified and as directed by Engr-in-charge.
Cleaning of water storage tanks and removing all scale and dirt, etc, from tanks and from mouths of circulating pipes etc, exc 250 & n. exc 500 ltr capacity.
All as per item No-30 above but Exc 500 & n. exc 1000 ltr capacity.
Dismantling timber scantlings 40 sq. cm and over in any position complete all as specified and directed
Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete Fe 290 Gde- E-165)
M&L preparation of new steel surfaces of any description not otherwise described over 10 cm width or girth and applying two coats of synthetic enamelled paint over one coat of red oxide Zinc chrome primer complete all as specified.
Dismantling of Plain or corrugated steel sheeting , any gauge, thickness, including Nainital or similar pattern roof coverings etc. complete all as specified and directed. (Taking down of existing MS wind tie ( where required) to dismantle the mild steel sheet shall be deemed to be included in the quoted unit rates)
S&F Pre-painted galvalume( hot dip alloy of 55% Aluminium 43.5% Zinc 1.5% Silicon, AZ 150 gm/sqm both side) , Zincalume (steel) based corrugated sheet 0.50mm thick ,of an approved colour, having tensile strength of 550 Mpa, and finished with resin coat on both surfaces as in roof covering/ cladding to wall,including flashings , ridges, valley etc fixed with self tapping screws complete all as specified.
pk janardhanan
CVs CONSTRUCTIONS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .