| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.3 LAccepted-AOC SHIV BARI ROAD NEAR KASUMAL HOTEL BIKANER 334003 RAJASTHAN | BIKANER | BIKANER | RAJASTHAN | 334003 | ₹27.3 L Quoted ₹27.7 L | L1 | Accepted-AOC L1 Bidder |
| 2 | L2₹27.9 L+₹14,737 (0.53%)Rejected-Finance BEHIND POWER HOUSE WARD NO 6 UDASAR BIKANER RAJASTHAN 334022 | BIKANER | RAJASTHAN | 334022 | ₹27.9 L+₹14,737 (0.53%) | L2 | Rejected-Finance Other than lowest bidder |
| 3 | L3₹29.3 L+₹1.5 L (5.54%)Rejected-Finance 270 ADARSH NAGAR ROORKEE HARIDWAR 247667 | HARIDWAR | UTTARAKHAND | 247667 | ₹29.3 L+₹1.5 L (5.54%) | L3 | Rejected-Finance Other than lowest bidder |
| 4 | L4₹32.3 L+₹4.6 L (16.6%)Rejected-Finance | ₹32.3 L+₹4.6 L (16.6%) | L4 | Rejected-Finance Other than lowest bidder |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
16 Dec 2020, 6:00 pmClosed
GE (N) Bikaner
GE (N) Bikaner Mil Stn Bikaner
REPAIR / REPLACEMENT OF LT PANEL, APFC PANEL WITH ACCESSORIES AND CONNECTED WORKS AT MIL STATION BIKANER
2020_MES_395817_1
GE (N) BKN-Token/48/2020-21
Open Tender
Electrical and Maintenance Works
Item Rate
330 days
GE (N) Bikaner
Class D category b (i)
7 documents required · 7 mandatory
₹500
GE(N) Bikaner
₹60,000
Yes
27 Apr 2021
17 Nov 2020
18 Dec 2020
17 Nov 2020
16 Dec 2020
2 Dec 2020
Amount
NOTES FOR ALL ITEMS:- 1.All BOQ Items are considered for fault repair and maintanace of LT panel , APFC panel ,servo stabilizer and connected infrastucture at Bikaner Mil station and different ASCON nodes located at 200 KMs away from Bikaner City. No extra cost for fault finding at ASCON nodes will be given to contractor AND CONTRACTOR 'S QUOTED RATE INCLUDES FOR THE SAME. 2.Repair and maintanace intimated to the contractor or his rep at any time day or night, through complaint slip or telephonically and compliant must be rectified by the contractor within 8 Hrs. 3. Material required for the repair and matainance work considered in the CA will be made available by the contractor with in 3 Hr for rectifying the complaint. Supply and fixing in Bus Bar Chamber cubical type of size 80x50x40 cm (Box size), with bus bar chamber having 4 wire 415 Volts, factory made dust proof vermin proof for out door using made out of CRCA sheet 2 mm thick powder coated, machine pressed, both side opening in two halves with provision of rubber beadings and locking system, including aluminium bus bar of 400 Amp capacity, 4 strip mounted on DMC/Epoxy insulator, bus bar chamber shall be provided with inspection covers, each MCCB/ cubical switch shall have independent opening , panel shall be mounted on angle iron frame and legs made from angle of size 40x40x6mm , frame and legs duly spray painted internally and externally with two coats of synthetic enamel paint over a coat of red oxide primer, legs grouted in PCC (1:2:4) type B-1(using 20 mm graded stone aggregate) complete including the following accessory complete all as directed by Engineer-in-charge.(i) MCCB, 200 Amps, 4 pole, 415 Volts, rupturing capacity not less than 36 KA, Icu=100% Ics, thermal magnetic trip with built in protection function for overload, short circuit and double break fast tripping mechanism complete withspreader link (incoming) -01 No.
All as per item No. 1 here-in-before but using aluminium bus bar of 300Amp capacity and including following accessory (i) MCCB, 160 Amps, 4 pole, 415 Volts, rupturing capacity not less than 25 KA, Icu=100% Ics, thermal magnetic trip with built in protection function for overload, short circuit and double break fast tripping mechanism complete withspreader link (incoming) -01 No.
All as per item No. 1 here-in-before but using aluminium bus bar of 200Amp capacity and including following accessory (i) MCCB, 100 Amps, 4 pole, 415 Volts, rupturing capacity not less than 25 KA, Icu=100% Ics,thermal magnetic trip with built in protection function for overload, short circuit and double break fast tripping mechanism complete withspreader link (incoming) -01 No.
Dis-connecting the ACB ( Air Circuit Breaker) panel capacity ranging from 600 to 2000 Amp of Make : CG/ABB /L&T /Simens /Schnider, Over hauling of complete bearker panel by taking out the trolley of the breaker, opening the total mechanism of breaker checking its contact, baffle plates and other minor parts, cleaning the complete accessories carefully. Minor repairs shall be rectified, Parts/accessories shall be cleaned, the tank, baffle plates, rotating contact, upper supports, lower supports, drive assembies and all other spare parts all as directed by Engineer-in-Charge. Reassembled Breaker after repair/ replacement of the faulty parts, testing and calibration of ACB realy settings complete.
Supply only spring charging motor 220 V AC/DC supply.
Su pply onlyShunt Release EA1 415V AC
Supply only Under-voltage Release 415V AC
Supply only Closing Preventer 415V AC
Supply only Jaw contact Assy. 630/1000A S1
Supply only Jaw contact Assy. 800/1000A C/H & 1250A S1
Supply only Jaw contact Assy. 1250/1600A C/H, 1600/2000A S1
Supply only Pole Assy. 630-1250 S1 D/O
Supply only Pole Assy. 1250/1600 C & 1600 S1 D/O
Supply only Pole Assy. 2000 C & 2500 S1 D/O
Supply only Arc Chute 800-2000 E, 800-1600 C/H, 1600/2000S1 (440V)
Supply only Arc Chute 2000 C/H, 2500 C/H/S1 (440V)
M& L for programming, repairing and rewiring of LT panel with two/three source incomer ACBs of capcity 600 to 2000 Apms with interconnection and inter locking arrangement for handling both the source supply complete, including wiring, programming of any type of relay relay, replacement of minor parts are connectors, copper wire for wiring, timing relays, indicators etc complete all as specified and directed by Eng-in-charge. Note : Spares like relay MCB, MCCB and power contactors are measured and paid separatly.
Taking out old underground LT Cable of size 10 sqmm to 120 Sqmm of 3.5 core from LT Panelstrenches/floors /road/wall/ pipe/pole/including taking out loop from trenches upto 1.5 mtrs depth, cutting the faulty end of cable and refixing the cable in original position by using flat aluminium sockets/ thimble/ and insulating the all nacked wires of any size including making connection with MCCB's/ Switches complete all as directed by Engineer-in-Charge. Note : Exacavation for taking out LT cable from will measured and paid separatly.
All as per item No. 18 here-in-before but 150 Sqmm to 630 Sqmm 3.5 core
Excavation in trenches not exceeding 1.5 mtr wide, and not exceeding 1.5 mtr in depth; for laying of cables, pipes in soft/loose soil etc and not exceeding 10 Sqm on plan and getting out including trimming of sides all as specified and directed by Engineer-in-Charge
Returning filling in, including spreading , levelling, watering and well ramming in layers each not exceeding 25cm in soft/loose soil complete all as specified.
Removing surplus spoil to distance not exceeding 50metre and depositing where directed at level not exceeding 1.5metre above the starting point complete all as specified.
Laying only bricks for protection to cable with one layer of old bricks retrieved from item No 04 laid flat abutting to each other in such a way that the length of the brick is at right angle to the central axis of the cable complete all as specified and as directed by Engr-in-Charge.
Local tibba dry sand cushioning and cover (8 cm thick layer of sand before laying of cable and 15 cm thick layer of sand after laying of cable) for protection of cable, material and labour complete all as specified and as directed by Engineer-in-Charge.
Dis connecting the LT panel of any size and Cap and repair of complete panel by taking out the cable ,Bus -bar , Voltmtr , Amp mtr ,including wiring and other minor parts, cleaning the complete accessories carefully. Minor repairs shall be rectified Parts/accessories shall be cleaned properly and refixing the parts at its original locations, checking and repair of the internal panel wiring with suitable size of wire and remove the carbon deposited inside the contact, cleaning all other spare parts all as directed by the Engineer-in-charge and reassembled after repair/replacement of following parts. Note: Spare parts as required for replacement of existing worm out parts shall be measured and paid separately under appropriate items Nos a to here-in-after as supply only of make Crompton greaves and seimen.
Supply and fixing in replacement Cable indoor/outdoor end terminal jointing kit for LV/LT 1100 V cable heat shrinkable type joint kit complete with jointing material, 04 Nos coloured sleeves(Red, Blue, Yellow and black) each 45 cm long and accessories thimbles etc suitable for 25 sqmm to 50 sqmm 3.5 core XLPE armoured aluminium conductor cable including testing after jointing fixing in replcement complete all as specified and as directed by Engineer- in - charge.
Ditto All as per Srl Item No.26 Here in above but 70 Sqmm to 150 sqmm 3.5 core
Ditto All as per Srl Item No.27 Here in above but 185 Sqmm to 300 sqmm 3.5 core
Ditto All as per Srl Item No.28 Here in above but 400 Sqmm 3.5 core
Ditto All as per Srl Item No.29 Here in above but 500 Sqmm 3.5 core
Ditto All as per Srl Item No.30 Here in above but 630 Sqmm 3.5 core
Supply and fixing in replacement Cable jointing kit for LV/LT 1100 V cable for straight through , heat shrinkable type joint kit complete with jointing material and accessories suitable for 25 Sqmm to 50 Sqmm 3.5 core XLPE armoured aluminium conductor cable including testing after jointing, fixing in replacement complete all as specified as directed by Engineer-in-Charge.
Ditto All as per Srl item No 32 here in above but 70 Sqmm to 150 sqmm 3.5 Core
Ditto All as per Srl item No 32 here in above but 185 Sqmm to 300 sqmm 3.5 Core
Supply and fixing in replacement Cross linked poly-ethylene (XLPE) insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables ( heavy duty) with aluminium conductor, 1100 volts LT grade of cross-sectional area 10 Sqmm 02 core laid in trenches/through pipe in road crossings/ paths /drains /ducts /floors /along poles/walls/ceilings/ equipments etc supplied, fixed/ laid in repair including commissioning and testing complete all as specified and as directed by Engineer-in-Charge.(Note: :- (i) Necessary excavation and earth work, brick protection, sand cushioning and cover and GI pipe shall be measured and paid for separately.(ii) Road manually cutting/floor cutting/cutting holes etc in wall required for laying /fixing of cable etc shall be made good as per existing site condition. Nothing extra shall be admissible on this account and quoted rate for this item shall be deemed to include for the same) Make : Gloster/Havells/CCI/Polycab
Ditto All as per Srl item No 35 here in above but size of cable 25 Sqmm 4 core
Ditto All as per Srl item No 35 here in above but size of cable 35 Sqmm 3.5 core
Ditto All as per Srl item No 35 here in above but size of cable 50 Sqmm 3.5 core
Ditto All as per Srl item No 35 here in above but size of cable 95 Sqmm 3.5 core
Supply and fixing in replacement GI pipe light grade 40 mm bore (ISI marked) laid in trenches/ road crossings/ fixed to poles/ceiling / along walls/ path /drain/floors with and including all necessary clamps, nuts, bolts, washers etc and all fittings as required, complete all as specified and as directed by the Engineer-in-Charge. (Note :- Necessary excavation, earth work and same work shall be measured and paid for separately.)
Ditto All as per Srl item No 40 here in above but dia of pipe 50 mm
Boring of holes under road 100 mm dia, pavement, hard standing by trench less technology(manually) with out disturbing the top surface of roads for laying of cables/GI pipes complete all as specified and as directed by the Engineer-in-Charge.
Taking out old LT underground cable from trench depth upto 1.5 mtrs and laying after removing of defects any type/size laid in trenches including testing complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing in replacement shutters made out of 2.00 mm thick mild steel sheet, bent to shape, including taking out old damaged unservicable shutter complete with hinges, handle etc. complete all as directed by Engineer-in-Charge.
Supply and fixing in replacement mild steel medium weight Butt Hinges 100 mm long and fixed with steel screws complete all as specified.
Supply and fixing in replacement mild steel medium weight Butt Hinges 75 mm long and fixed with steel screws complete all as specified.
Supply and fixing in replacement mild steel pressed handles, size 75mm,complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing in replacement mild steel pressed handles, size 100 mm,complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing in replacement indicator lamp in diffrent colour code LED/Neon type complete (RYBW) including wiring with copper conductor cable of suitable size complete all as specified and as directed by Engineer-in-charge.
Supply and fixing in replacement Aluminium bus bar of size 50 mm X 10 mm with aluminium thimbles nuts, bolts, washers etc complete all as specified and as directed by Engineer-in-charge Note- Aluminium bus bar strips shall be covered with PVC insulation tape of red , yellow, blue and black colour for proper colour coding as per IE rules. Cost of nuts ,bolts, washers, insulation etc. shall be inclusive in the quoted rates.
All as per item No. 52 here-in-before but Aluminium bus bar of size 50 mm x 6 mm
Supply and fixing in replacement Bakelite sheet 10 mm thick, ISI marked complete all as specified and as directed by Engineer-in-charge.
Supply and fixing in replacement Isolator 4 Pole 100 Amp Make : ABB/Simens/Scheider/Legrand
Supply and fixing in replacement MCB 4 Pole 63 Amp Make : ABB/Simens/Scheider/Legrand
Material & labour wiring with PVC insulated stranded copper conductor cable 4.00 sqmm complete all as specified and as directed by Engineer-in-charge.
Material & labour wiring with PVC insulated stranded copper conductor cable PVC wire 6 Sqmm single core copper conductor
Material & labour wiring with PVC insulated stranded copper conductor cable 16 sqmm single core complete including suitable size of Luxes/thimble all as specified and as directed by Engineer-in-charge.
Supply and fixing in replacement for danger notice plate of 1.6 mm thick mild steel sheet, vitreous enameled white, with letters figures and conventional skull and bones in signal red colour and fixed with MS clamps, bolts, nuts or approved size for LT 20 x 15 cm size all as specified.
Cleaning and preparation of old painted surface of LT panel board complete and spray painting with two coat of synthetic enamel paint with appoved paint all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement MCCB, 63 Amps, 4 pole, 415 Volts, rupturing capacity not less than 25 KA, Icu=100% Ics, thermal magnetic trip with built in protection function for overload, short circuit and double break fast tripping mechanism complete withspreader link including thimbles, nuts, bolts, washers etc. making including incoming and outgoing connection complete all as specified.
Supply and fixing in replacement MCCB, 100 Amps, 4 pole, 415 Volts, rupturing capacity not less than 25 KA, Icu=100% Ics, thermal magnetic trip with built in protection function for overload, short circuit and double break fast tripping mechanism complete withspreader link including thimbles, nuts, bolts, washers etc. making including incoming and outgoing connection complete all as specified.
Supply and fixing in replacement MCCB, 160 Amps, 4 pole, 415 Volts, rupturing capacity not less than 25 KA, Icu=100% Ics, thermal magnetic trip with built in protection function for overload, short circuit and double break fast tripping mechanism complete withspreader link including thimbles, nuts, bolts, washers etc. making including incoming and outgoing connection complete all as specified.
Supply and fixing in replacement MCCB, 200 Amps, 4 pole, 415 Volts, rupturing capacity not less than 36 KA, Icu=100% Ics, thermal magnetic trip with built in protection function for overload, short circuit and double break fast tripping mechanism complete withspreader link including thimbles, nuts, bolts, washers etc. making including incoming and outgoing connection complete all as specified.
Supply and fixing in replacement MCCB, 320 Amps, 4 pole, 415 Volts, rupturing capacity not less than 36 KA, Icu=100% Ics, thermal magnetic trip with built in protection function for overload, short circuit and double break fast tripping mechanism complete withspreader link including thimbles, nuts, bolts, washers etc. making including incoming and outgoing connection complete all as specified.
Supply and fixing in replacement MCCB, 400 Amps, 4 pole, 415 Volts, rupturing capacity not less than 36 KA, Icu=100% Ics, thermal magnetic trip with built in protection function for overload, short circuit and double break fast tripping mechanism complete withspreader link including thimbles, nuts, bolts, washers etc. making including incoming and outgoing connection complete all as specified.
Supply and fixing in replacement MCCB, 630 Amps, 4 pole, 415 Volts, rupturing capacity not less than 50 KA, Icu=100% Ics, thermal magnetic trip with built in protection function for overload, short circuit and double break fast tripping mechanism complete withspreader link including thimbles, nuts, bolts, washers etc. making including incoming and outgoing connection complete all as specified.
Supply and fixing in replacement MCCB, 800 Amps, 4 pole, 415 Volts, rupturing capacity not less than 50 KA, Icu=100% Ics, thermal magnetic trip with built in protection function for overload, short circuit and double break fast tripping mechanism complete withspreader link including thimbles, nuts, bolts, washers etc. making including incoming and outgoing connection complete all as specified.
Repair of manual operated PF control panel / micro processor based automatic power factor control panel capacity of 21 KVAR to 500 KVAR fixed on various locations including testing, checking and repair and after removing deposited dust/seals/sludge and including taking out burnt/defective items and after fixing required necessary new items ie capacitor, MCBs, circuit wiring etc all as directed by Engr-in-Chaerge.
Supply only MPP type heavy duty power factor improvement capacitor (H/D ) with connector suitable for indoor/out door operation and provided with discharge resistors of rated voltage 440 v 50 HZ 3 phase with delta connection of rating 1 KVAR to 35 KVAR all as specified Make : L/T , SIEMEN Epcos
Supply only Push botton switch 6 A capacity 240 volts Make RAAS/Alfa/ Veeco
Supply only Miniature circuit breaker triple pole 40 Amp (C curve) 10 KA of capacity
Supply and fixing in replacement MCCB, 63 Amps, 3 pole, 415 Volts, rupturing capacity not less than 25 KA, Icu=100% Ics, thermal magnetic trip with built in protection function for overload, short circuit and double break fast tripping mechanism complete withspreader link including thimbles, nuts, bolts, washers etc. making including incoming and outgoing connection complete all as specified.
Supply and fixing in replacement MCCB, 100 Amps, 3 pole, 415 Volts, rupturing capacity not less than 25 KA, Icu=100% Ics, thermal magnetic trip with built in protection function for overload, short circuit and double break fast tripping mechanism complete withspreader link including thimbles, nuts, bolts, washers etc. making including incoming and outgoing connection complete all as specified.
Supply and fixing in replacement MCCB, 160 Amps, 3 pole, 415 Volts, rupturing capacity not less than 25 KA, Icu=100% Ics, thermal magnetic trip with built in protection function for overload, short circuit and double break fast tripping mechanism complete withspreader link including thimbles, nuts, bolts, washers etc. making including incoming and outgoing connection complete all as specified.
Supply and fixing in replacement LT current transformers of capacity 100/5,200/5,300/5,500/5, Amps Make Alfa/ AE/ Veeco
Panel mounted 3 Pole contactor of suitable rating operational voltage 500 volts, AC 50 HZ, inbuilt aux. contacts- 1 No + 1 NC or 2 NO + 2 NC with standard coil voltage 220 volts the surge resistor contract shall be post break type and damping resistances after closing be cut of current rating cap 15 Amp. Make :ABB/BCH/ Siemens/L&T
All as per item No. 78 here in before but rating of capacity 25 Apms.
All as per item No. 78 here in before but rating of capacity 40 Amps.
All as per item No. 78 here in before but rating of capacity 63 Amps.
All as per item No. 78 here in before but rating of capacity 100 Amps.
Supply and fixing in replacement APFC Relay 8 stage with built in multifuction meter for basic, THD and energy with 1 CT/3 CT sensing Option, smart switching, auto setup, THD protection, dual target PF, RS 485 communication, remote monitiring software complete all as directed by Eng-in-charge
All as per item No. 83 here in before but for 12 stage.
Dis connecting the LT servo stablizer of cap 25 KVA to 200 KVA of any Make and repair of completeservo steblizer by taking out the main circuit plate, servo motors with gears, micro servo voltage controller, cable ,cable terminals etc ,including wiring and other minor parts, cleaning the complete accessories carefully. Minor repairs shall be rectified Parts/accessories shall be cleaned properly and refixing the parts at its original locations, checking and repair of the main circuit panel wiring with suitable size of wire and remove the carbon deposited inside the contact, cleaning all other spare parts all as directed by the Engineer-in-charge and reassembled after repair/replacement of following parts. Note: Spare parts as required for replacement of existing worm out parts shall be measured and paid separately under appropriate items Nos a to here-in-after as supply only.
Supply only servo motor for automatic voltage controller 220 Volts, 50 Hz 10 Kg cap
Supply only automatic voltage controller 220 Volts, 50 Hz
Supplying and filling new mineral grade transformer oil conforming to IS 3357 of 1983 for filling and for topping up in transformer duly filtered with filtration plant to obtain high dielectric strength not less than 40 KV (gap 2.5mm) complete all as specified and as directed by Engineer in charge.
Taking down carefully the defective street light fittings any kind any type from the poles/walls and refixing the same on poles/walls after repair complete all as directed by Engineer in Charge. ( Note:- A Team of workers for emergency are available inside the camp for 24 Hours) 1. T&P i.e, ladder and vehicle will provided by the contractor.2. The contractor/his rep will collect the complaint from JE every day 9.00 hrs , the same will be rectified before sunset on same day,If the contractor fail to rectify the defect mentioned in the complaint slip on same day, he will be charged Rs 500/per complaint and same will be recovered from the contract amount.
S&F in replacement tube rod for energy efficient street light 24W. Make : Cat Pt Nos T5 24W 6500K (ENERGYLUX) in CG or equivalent to Bajaj/Philips
S&F electronic ballast 2 X 24 Watt suitable for 4x24W street light fitting. Make :Cat Pt Nos EB224T5-A/I in CG or Bajaj/Philips
Supply and fixing in replacement Bipin holder for tube light fittings. Make – Bajaj/Philips/Crompton Greaves
S&F in replacement CFL 36watt 04 PL suitable for street light fitting ‘L’ type.Cat Pt Nos 36W CFL 4P 6500K/2700K/4000K in CG or equivalent to Bajaj/Philips
Supply and fixing in replacement choke/ballast electronic 36/40 watt 230 volt for tube light /CFL fitting. Make – Cat Pt Nos EBN136-A/Sin CG or equivalent to Bajaj / Philips
Supply and fixing in replacement Bipin holder for tube light / CFL fittings. Make – Bajaj/Philips/Crompton
Supply and fixing in replacement for Multistranded single core PVC insulated FRLS copper conductor cable of size 2.5 sqmm (nominal area), & drawing into hollow street light pole from fitting to distribution box or fitting to over head line all as specified including taking out old existing unserviceable cable.
Supply and fixing in replacement for two core PVC insulated weather proof cable with aluminum conductor size 4 sqmm (nominal area), & drawing into hollow street light pole from fitting to distribution box or fitting to over head line all as specified including taking out old existing unserviceable cable.Make Paragone ,finolex , Gloster
Ditto all as per Srl Iem No 97 here in before but size of cable 6 Sqmm 2 core.
BIDAWAT ENTERPRISES
A.S. CONSTRUCTION COMPANY
ALPHA ENGINEERING COMPANY
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .