Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹31.1 LAccepted-AOC FLAT NO 601 TOWER NO 30 SECTOR NO 21 AMANORA PARK TOWN HADAPSAR PUNE 411028 | PUNE | MAHARASHTRA | 411028 | ₹31.1 L Quoted ₹33.3 L | L1 | Accepted-AOC LOWEST |
| 2 | L2₹33.9 L+₹64,328 (1.93%)Rejected-Finance | ₹33.9 L+₹64,328 (1.93%) | L2 | Rejected-Finance RATE HIGH |
| 3 | L3₹34.4 L+₹1.1 L (3.42%)Rejected-Finance 02 NERLE NERLE YEWALEWADI ROAD NERLE SANGLI MAHARASHTRA 415406 | SANGLI | MAHARASHTRA | 415406 | ₹34.4 L+₹1.1 L (3.42%) | L3 | Rejected-Finance RATE HIGH |
| 4 | L4₹36.7 L+₹3.4 L (10.2%)Rejected-Finance SHOP NO 11 18 CITY CENTRE 930 931 SYNAGOGUE STREET PUNE 01 | ₹36.7 L+₹3.4 L (10.2%) | L4 | Rejected-Finance RATE HIGH |
| 5 | L5₹36.9 L+₹3.6 L (10.8%)Rejected-Finance 3RD FLOOR BHAKTAMAR RESIDENCY SOMNATHNAGAR ROAD PUNE 411014 | PUNE | PUNE | MAHARASHTRA | 411014 | ₹36.9 L+₹3.6 L (10.8%) | L5 | Rejected-Finance RATE HIGH |
Tender Value
₹49 L
EMD Value
₹98,000
Closing Date
9 Sept 2023, 6:00 pmClosed
GE South Pune
GE south, 1- General Bhagat Marg, Pune-40
PERIODICAL MAINT OF DG SETS AND REPAIR MAINT OF PANELS, CABLES, PROTECTIVE SYSTEM, APFC PANEL, MCCB, CAPACITORS AND OTHER MISC WORK IN CHSC AND OTHER CONNECTED AREA OF AGE EM-II UNDER GE (SOUTH) PUNE
2023_MES_613571_1
8467 PERIODICAL MAINT OF DG SETS AND REPAIR MAINT
Open Tender
Electrical and Maintenance Works
Item Rate
333 days
GE South Pune
As per tender documents
8 documents required · 8 mandatory
₹500
GE South Pune
₹98,000
Yes
7 Dec 2023
12 Aug 2023
11 Sept 2023
14 Aug 2023
9 Sept 2023
28 Aug 2023
Amount
Servicing of DG sets by carryout inspection / checking of cylinder assembly, piston system, piping system, cylinder liners, radiator function and cleaning thoroughly with cleaning agents, repair any mechanical and electrical fault etc. including replacement of defect / unserviceable spare parts with new one (if any) complete all as directed for the following capacities of DG sets located at different locations: - (i) 1010 KVA DG sets model Cummins at New CHSC - 6 nos. Note for item nos 01 to 04: - (a) Spares parts (if any) shall be measured and paid separately under item nos.20 to 31 & 25 to 37 of BOQ as “Supply only”. (b) The cost of labour & T & P required for servicing of DG Sets shall be deemed to be included in unit quoted rates of this item. The contractor is responsible to provide 24x7 call back service and repair facility through skilled, competent and well experienced technician. No DG Set will be left unserviceable more than 4 hrs. If DG set found unserviceable for more than 04 hrs from the time it was reported to the contractor during the term of this contract recovery @ Rs.1000.00 per such Non-functional DG Set per day will be imposed and will be recovered from the amount due to the contractor. Regarding this the decision of Accepting Officer shall be final and binding. (c) All dismantled old unserviceable items, except those listed in schedule of credit, retrieved from any DG set shall be deposited to MES store yard.
All as per item No 1 above but 380 KVA DG Set model Cummins at MDTC - 2 nos.
All as per item No 1 above but 320 KVA DG set modet Greaves cotton at new CMDC - 1 nos
All as per item No 1 above but 30 KVA DG set model Ashoka Leyland at 20 Single Officers and 17 MNS - 2 nos
S&F in replacement V belt for fan / water pump assembly etc suitable for 1010 KVA DG set, complete all as directed.
S&F in replacement V belt for fan/water pump assembly etc suitable for 320/380 KVA DG set, complete all as directed.
S&F in replacement V belt for fan/water pump assembly etc suitable for 30 KVA DG sets, complete all as directed.
S&F in replacement neoprene rubber gaskets of suitable size, complete all as directed.
S&F in replacement gasket for Exhaust manifold for 1010 KVA DG set, complete all as directed.
S&F in replacement gasket for Exhaust manifold 320/380 KVA DG set, complete all as directed.
S&F in replacement Air hose set for 1010 KVA DG set, complete all as directed.
S&F in replacement Air hose set for 380/320 KVA DG set, complete all as directed.
S&F in replacement water hose set for 1010 KVA DG set, complete all as directed.
S&F in replacement water hose 380/320 KVA DG set, complete all as directed.
S&F in replacement water hose for 30 KVA DG sets, complete all as directed.
S&F in replacement hose clamp set for 1010 KVA DG set, complete all as directed.
S&F in replacement hose clamp set for 380/320 KVA DG set, complete all as directed.
S&F in replacement hose clamp set for 30 KVA DG sets, complete all as directed.
S & F in replacement water temperature gauge including sensor and cable complete as per site requirement suitable for DG set of capacity 1010 / 380 / 320 / 30 KVA including taking down existing one, complete all as directed.
Supply only Air filter elements suitable for 1010 KVA DG set, complete all as directed.
Supply only Air filter elements suitable for 380/320 KVA DG set, complete all as directed.
Supply only Air filter elements suitable for 30 KVA DG sets, complete all as directed.
Supply only oil filter suitable for 1010 KVA DG set, complete all as directed.
Supply only oil filter suitable for 380/320 KVA DG set, complete all as directed.
Supply only oil filter suitable for 30 KVA DG sets, complete all as directed.
Supply only Diesel filter suitable for 1010 KVA DG set, complete all as directed.
Supply only Diesel filter suitable for 380/320 KVA DG set, complete all as directed.
Supply only Diesel filter suitable for 30 KVA DG sets, complete all as directed.
Supply only By-pass filter suitable for 1010 KVA DG set, complete all as directed.
Supply only By-pass filter suitable for 380/320 KVA DG set, complete all as directed.
Supply only By-pass filter suitable for 30 KVA DG sets, complete all as directed.
S&F in replacement solenoid valve for 1010 KVA DG set including taking down existing one, complete all as directed.
S&F in replacement solenoid valve for 380/320 KVA DG set including taking down existing one, complete all as directed.
S&F in replacement solenoid valve for 30 KVA DG sets including taking down existing one, complete all as directed.
Supply and toping up of engine oil of grade SAE 15 W 40 as directed in standard packings / sealed container including taking out existing one, complete all as directed.
Supply and toping up of distilled water in standard packing /sealed container including taking out existing one, complete all as directed.
Supply and toping up of coolant in standard packings / sealed container including taking out existing one, complete all as directed.
Supply and applying Petroleum jelly on battery terminals , complete all as directed.
M &L Lifting loading and transportation of lead acid battery to work shop and repair to lead acid battery of 12 volt of 90/150/180 AH by filling up of distilled water, changing of worn out cells, changing of unseviceble electrode / electrolyte etc, complete all as directed.
Supply and fix in repairs battery terminal made out of brass / bronze heavy duty suitable for 150 AH/180 AH 12 Volt Battery, complete all as directed.
S&F in replacement PVC insulated multisranded, copper conductor single core 70 sqmm multistranded of 1.25 mtr long each duly fixed with brass clamps, copper lugs suitable for DG sets installed at different locations from battery to starter as battery leads, complete all as directed.
Overhauling, repairing, calibartion of FIP set as per manufacturer's instruction and replacement of unserviceable component by providing new ones as per existing size and make all as required at site suitable for DG Set 1010 KVA, complete all as directed.
All as per item no 42 above but DG Set 380/320 KVA
All as per item no 42 above but DG Set 20 KVA
Disconnecting all incoming and outgoing rubber hose & drain out checking radiator assembly of the following various capacities of DG sets and taking down the radiator assembly transporting the same to civil workshop for carrying out servicing, cleaning thoroughly the choke pipe, soldering / brazing the leakage pipe after completion of said activities, re-fixing the same to its original position of 1010 KVA capacity DG sets complete all as directed by Engineer-in-charge.
All as per item no 45 above but DG set 380/320 KVA
All as per item no 45 above but DG set 20 KVA
S&F in repair AMF controller suitable for DG set 1010 KVA including taking down existing one, complete all as directed.
S&F in repair AMF controller suitable for DG set 380/320 KVA including taking down existing one, complete all as directed.
S&F in repair AMF controller suitable for DG set 30 KVA including taking down existing one, complete all as directed.
Supply and fix in repair automatic voltage regulator suitable for 380/320 KVA DG set with facility of auto / manual mode as per existing capacity and make suitable for DG sets complete as per existing DG sets all as directed by Engineer-In-Charge.
Supply and fix in repair automatic voltage regulator for 1010 KVA DG set with facility of auto / manual mode as per existing capacity and make suitable for DG sets complete as per existing DG sets all as directed by Engineer-In-Charge.
S&F in replacement self starter suitable for 24 Volt DC operation Make - Lucas including disconnecting and taking down the existing unserviceable self starter & depositing to MES store yard, complete all as directed.
Supply, fixing, testing in replacement of Speed control unit suitable for 1010 KVA as per exising make, complete all as directed.
Supply,fixing, testing in replacement of Speed control unit suitable for 380/320 KVA as per exising capacity /make, complete all as directed.
Supply and fix in repair fuel steel braided pipe with benjo bolt and washers etc of length 60cm long, complete all as directed.
Supply and fix in repair pressure guage 0 to 7 Kg/sqcm along with sensor and cable complete all as directed by Engineer-In-Charge.
Supply and fix in repair lead acid battery 12 Volts 150 AH with initial charging and having indicators to know the status of level of electrolyte , complete all as directed. Make-Exide/AMCO/Amaron.
S & F in replacement Reverse Power relay suitable for DG panel of 1010/380/320 KVA DG set as per site requirement including taking down existing one complete all as specified and directed. Make L&T MRP11 or equivalent in Legrand / ABB/ Havells
S&F in repair electronic timers including taking down exsiting one, complete all as directed.
S&F in repair single phase preventer including taking down existing one, complete all as directed.
S&F in replacement of Digital Multifunction Meter 4410 Series LED, Accuracy Class 1, with RS 485 Parameters V, A, F, PF, kW, kVA, kVAR, kWh, kVAh, kVARh, Runhours etc. without disturbing other accessories and taking down old unserviceable meters etc complete all as specified and directed at site.
Supply & Installation in replacement of DC Ammeter / Voltmeter and taking down old unserviceable meters etc complete all as specified and directed at site.
Supply & Installation in replacement of under voltage / over voltage proection relay including taking down existing one complete all as specified and directed at site.
S&F in repair Indicating lamp (Red/Yellow/Blue) LED type including taking down existing one, complete all as directed.
S&F in repair Push botton including taking down existing one, complete all as directed.
S & F in replacement emergency stop button push and turn type as per site requirement including taking down existing one complete all as specified and directed.
S & F control wiring of 1.5 Sqmm size single core stranded FRLS PVC insulated copper conductor cables of suitable size properly tagged and secured for indicators/ Meters etc. including suitable size of copper lugs, PVC CABLE ducts , suitable size of galvanised or cadmium plated high tensile nuts, bolts and washers etc complete all as specified and directed.
S & F control wiring of 2.5 Sqmm size single core stranded FRLS PVC insulated copper conductor cables of suitable size properly tagged and secured for indicators/ Meters including suitable size of copper lugs, with galvanised or cadmium plated high tensile nuts, bolts and washers etc complete all as specified and directed.
S & F in replacement Aux contactor block and add on block 2no+2nc suitable for DG panel of 1010 KVA DG set as per site requirement including taking down existing one complete all as specified and directed. Make:- L&T MO 0 or equivalent in Legrand / ABB / Havells
S & F in replacement Aux contactor block and add on block 2no+2nc suitable for DG panel of 380/320 KVA DG set as per site requirement including taking down existing one complete all as specified and directed. Make- L&T MO 0 or equivalent in Legrand / ABB / Havells
S & F in replacement 12 window Annunciator as per site requirement including taking down existing one complete all as specified and directed. Make- Minilec or equivalent in Legrand/L&T/Havells
S & F in replacement Panel hooter as per site requirement including taking down existing one complete all as specified and directed.
S&F in replacement Micro PLC for Auto Load Management (Allen Bradley / Siemens) as per Logic mentioned in specifications, comprising required Auxiliary relays, (24V DC, indication lights, Push button, Emergency stop, A/M position switch 1 Pole, Battery charger (230V A/C / 24V DC), PLC - CPU - 226, 24V DC of Siemens make or equivalent, Digital I/O card, analogue card, 24V DC power supply as required, complete all as directed.
S&F Fuel level pipe of 10 mm dia including taking down existing one complete all as specified and directed.
M&L for repair of Space Heater circuit including replacment of thermostat 0-180 °C as per site requirement including taking down existing one complete all as specified and directed.
S&F in replacement of fan of existing make, suitable for Panel Ventilation as per site requirement including taking down existing one complete all as specified and directed.
M&L for Preparation of old painted surfaces of the DG Set fuel tank and connected GI Pipe etc painting the same with two coats of approved synthetic enamel paint of approved shade complete all as specified and directed by Engr-in-Charge.
M&L for painting of DG Set Exhaust chimney with two coats of synthetic enamel aluminium paint silver colour paint by scrapping the old surface of exhaust and applying one coat of red oxide primer on the surface and making good complete all as spceified and as directed. Note:- Contracor will be provided all the safety equipments such as safety belt etc. to the labour at his own cost.
M&L for writing SM/MES Number on DG set of approved synthetic enamel paint of approved shade and appropriate size of letters complete all as directed by Engr-in-Charge.
Taking down the unserviceable turbo charger assembly after disconnecting the mechanical connections from DG Set of capacity 1010 KVA of any make / type opening and thoroughly checking to carrying out repairs to the turbo charger assembly and replacing the turbo charger repair kit and mirror spares as required including calibrating, servicing and assembling and re-fixing back the turbo charger assembly to its original position and testing complete all as specified and directed
M&L for earthing complete with galvanised steel earth plate electrode 600x600x6.3 mm thick buried directly in ground vertically to a depth not less than 2.25mtr deep below ground level with top edge of the earth plate not less than 1.5mtr deep below normal ground level, connected with & including galvanised iron strip 32 x 6 mm connected to main test point as directed as earthing lead by means of nuts, bolts and washers of galvanised iron protected by 15 mm dia (medium grade) including concrete pit in PCC (1:3:6) type C-1, RCC cover slab 55 cm x 55 cm x 5 cm with reinforcement of 8 mm dia bar 100 mm c/c both ways including one handle made of 12 mm dia MS bar embedded in pre cast slab and 20 mm bore galvanised iron pipe "medium grade" for watering with GI funnel and wire mess including charcoal and salt in alternate layers of 15 cm including necessary excavation and earth work in any type of soil complete all as specified and as directed and testing on completion
Supply, installation, commissioning and testing of chemical earthing for GI pipes one inside the other with proper galvanization. The outer dia is of 88 mm & inner dia is 48 mm and the cavity filled with highly conductive, non-corrosive material. There is additional copper coating on the outer surface. With supply of fast electrode earth enhancement compound / (2 bags of 25 Kg each) which is highly hygroscopic, non-corrosive & good PH value certified by NABL approved lab and including copper earth plate 90x60 cmx5 mm and copper earth strip 32x6 mm (with nuts, bolts & check nuts) and riveted to earth electrode at one end and connected to metallic bodies of equipment’s etc at the other, earth strip encased in and including 40mm bore GI medium grade pipe with all fittings from top of electrode to body of equipment fixed with and including 40 x 6mm flat iron clamps, bolts, nuts and washer complete with earth pit in PCC 1:2:4 type B-O using 12 mm graded crushed stone aggregate, RCC cover, funnel, wire mesh including necessary excavation and earth work , etc. complete all as specified and directed by Engr-in-charge. Note:- The earthing result should not be less than 1 ohm and testing equipment shall be provided by contractor without any extra cost to the Department.
M&L for Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit / pipe or fixed to poles or any other indicated situation for loop earthing etc as required for 32x6 galvanized iron strip, complete all as specified and directed.
S & F in repair CT cast resin type of ratio 100/5 amps, of suitable VA burden as per site requirement complete all as specified and directed. Make : AE / L&T / Nutech / Amol
S & F in repair CT cast resin type of ratio 200/5 amps, of suitable VA burdena s per site requirement complete all as specified and directed. Make : AE / L&T / Nutech / Amol
S & F in repair CT cast resin type of ratio 500/5 amps, of suitable VA burden as per site requirement complete all as specified and directed. Make : AE / L&T / Nutech / Amol
S & F in repair CT cast resin type of ratio 600/5 amps, of suitable VA burden as per site requirement complete all as specified and directed. Make : AE / L&T / Nutech / Amol
S & F in repair CT cast resin type of ratio 800/5 amps, of suitable VA burden as per site requirement complete all as specified and directed. Make : AE / L&T / Nutech / Amol
S & F in repair CT cast resin type of ratio 1600/5 amps, of suitable VA burden as per site requirement complete all as specified and directed. Make : AE / L&T / Nutech / Amol
S & F in repair CT cast resin type of ratio 3200/5 amps, of suitable VA burden as per site requirement complete all as specified and directed. Make : AE / L&T / Nutech / Amol
Attending the fault in APFC panel including repairing of APFC relay, Contactor of any make/capacity, digital lamp, switch and setting the APFC panel for proper function, testing connection of capacitor bank of any capacity including replacing small spare parts below Rs. 500/Each, repairing and blowing out dust from inside the APFC panel complete all as specified and directed. Note:- Attending of one number complaint / fault and make it functional complete in all respect will be measured as one Job.
S&F in repair APFC controller 14 step for automatic correction of power factor suitable for 415 volt 3 phase power supply complete with necessary fixing complete all as directed by Engr-in-charge. Make- L&T Cat no-etaSMART 14R or equivalent in ABB / siemens.
S&F in repairs digital voltmeter 0-500 volts square type complete with necessary fixing with and including 3 nos. of CTs complete all as specified and as directed by Engr-in-charge. Make: L&T/Siemens/Schneider
S&F in repairs digital ammeter 0-400 amps square type complete with necessary fixing with and including 3 nos. of CTs complete all as specified and as directed by Engr-in-charge. Make: L&T/Siemens/Schneider
S&F in repair ultra heavy duty capacitors bank cylindrical series 25 KVAR for automatic correction of power factor suitable for 415 volts, 3 phase power supply complete with necessary connection and replacing the unserviceable capacitor bank of any type complete as directed by Engr-in-charge. Make- L&T Cat no-LTCCU or equivalent cat part in ABB/Epcos makes.
S&F in repair ultra heavy duty capacitors bank 50 KVAR for automatic correction of power factor suitable for 415 volt 3 phase power supply complete with necessary connection and replacing the unserviceable capacitor bank of any type complete all as directed by Engr-in-charge. Make- L&T Cat no-LTBCU or equivalent cat part in ABB/Epcos makes.
S&F in repair Capacitor duty Contactors sutable for 25 KVAR capacitor bank complete all as specified and directed by Engineer-in-Charge. Make- L&T /Siemens/Schneider
S&F in repair Capacitor duty Contactors sutable for 50 KVAR capacitor bank complete all as specified and directed by Engineer-in-Charge. Make- L&T /Siemens/Schneider
S&F in replacement MCB SP 6-32 Amps, 10KA, 'C' series complete all as specified and as directed.
S&F in replacement MCB SPN 6-32 Amps, 10KA, 240V, 'C' series complete all as specified and as directed.
S&F in replacement MCB SPN 40-63 Amps, 10KA, 240V, 'C' series complete all as specified and as directed.
S&F in replacement MCB TP 25-63 Amps, 10KA, 240V, 'C' series complete all as specified and as directed.
S&F in replacement MCB TPN 16-32 Amps,10KA, 240V, 'C' series complete all as specified and as directed.
S&F in replacement MCB TPN 40-100 Amps, 10KA, 240V, 'C' series complete all as specified and as directed.
M&L for design, supplying, installing, test and commissioning of free standing floor mounted, dust and vermin proof LT Panel of suitable size for outdoor installation factory made both front and rear side double door system, fabricated with 3.15 mm thick CRCA sheet for load bearing members and 2 mm thick for doors and covers and shall be painted with epoxy powder paint by means of electro static gun after rigorous pre treatment comprising of cold phosphating process on all internal and external surfaces after due preparation of surfaces. The panel shall consist of 600 ,Amps rating TPN bus bars of high conductivity aluminium alloy and shall be provided with colour coded heat shrinkable sleeves, with 600 mm depth of the panel.
The panel shall be modular/cubical type with bus chamber cable allyand provided with separate fully compartments for each switch including instrumentation such as Ampere Meter, Volt meter, Phase indicating lamp with double stud hinged door , front and rear openable with locking arrangement and suitable for 1100 Volts grade , 3 phase 415 Volts , 50 cycles , AC Supply and to with stand short circuit fault level of not less than 10 KA and degree of protection shall be IP 54 . The panel shall be fixed with angle iron frame made of angles of size 50x50x6 mm, embedded 200 mm below ground level in PCC 1:2:4, Type B1 using 20 mm grade stone aggregate, 600 mm above ground level and comprising the following including taking out of old panels etc, removing of cables and connecting to new panels with all required material such as glands, lugs etc
INCOMING :- (a) MCCB 4 pole 400 Amps capacity rup cap 36 KA at 415 volt 50 Hz AC fixed thermal magnetic release type and earth leakage protection ICS =100% ICU with rotary handle - 01 No incoming. OUTGOING :- (a) MCCB 4 pole 200 Amps capacity rup cap 25 KA at 415 volt 50 Hz AC fixed thermal magnetic release typewith rotary handle - 02 Nos Out going. (b) MCCB 3 pole100 Amps capacity rup cap 16 KA at 415 volt 50 Hz AC fixed thermal magnetic release type with rotary handle - 02 Nos Out going. (c) MCCB 3 pole 63 Amps capacity rup cap 16 KA at 415 volt 50 Hz AC fixed thermal magnetic release type with rotary handle - 02 Nos Out going. (d) LT Danger notice plate -01 No. (e) Panel Control wiring complete with suitable size copper conductor cable and suitable size gland for LT cables.
Excavation in trenches not exceeding 1.5M wide and not exceeding 1.5M in depth as in cable trench, not exceeding 10 sqm on plan and getting out in hard / dense soil, complete all as specified and as directed.
Excavation in trenches not exceeding 1.5M wide and not exceeding 1.5M in depth as in cable trench, not exceeding 10 sqm on plan and getting out in soft / disintegrated rocks, complete all as specified and as directed.
Returning filling in including spreading leveling watering and well ramming in layers n.exc 25 cm complete all as specified and directed.
Removing excavated surplus soil to a distance n exc 50 m and depositing where directed at a level n exc 1.5 mtr above starting point complete all as specified and directed.
M&L for laying of half round reinforced concrete pipe of dia 150 mm, including half round for bottom and half round for top and before laying excaved area shall be leveled, complete all specified and directed. Note : 01 Half round top and 01 half round bottom together will be considered as one running meter. Make:- Topaz or equivalent
Supply, laying, testing and commissioning of size 400 Sqmm, 3.5 core LT cables 1100 volts grade, XLPE insulated and PVC sheathed, armored, multi stranded aluminum conductor, heavy duty conforming to IS - 1554 part-I, including cable glands, crimping type cable lugs in LT panel / MCCB in bldg etc to suit the cable laid in trenches / fixed to poles / drawn through pipes, complete all as specified and directed.
All as per item No 116 above but 300 sq mm 3.5 core, complete all as specified and directed.
All as per item No 116 above but 240 sq mm 3.5 core, complete all as specified and directed.
All as per item No 116 above but 185 sq mm 3.5 core, complete all as specified and directed.
All as per item No 116 above but 150 sq mm 3.5 core, complete all as specified and directed.
All as per item No 116 above but 120 sq mm 3.5 core, complete all as specified and directed.
All as per item No 116 above but 95 sq mm 3.5 core, complete all as specified and directed.
All as per item No 116 above but 70 sq mm 3.5 core, complete all as specified and directed.
All as per item No 116 above but 50 sq mm 3.5 core, complete all as specified and directed.
All as per item No 116 above but 35 sq mm 3.5 core, complete all as specified and directed.
All as per item No 116 above but 25 sq mm 3.5 core, complete all as specified and directed.
All as per item No 116 above but 16 sq mm 4 core, complete all as specified and directed.
All as per item No 116 above but 10 sq mm 2 core, complete all as specified and directed.
All as per item No 116 above but 6 sq mm 2 core, complete all as specified and directed.
All as per item No 116 above but 6 sq mm 4 core, complete all as specified and directed.
Supply and laying 80mm bore light grade GI pipe fixed to walls / poles or laid in trenches, road crossing etc, for protection of underground cable including sealing ends with hessian cloth impregnated with bituminous compound in ground and with suitable clamps, bolt/nuts etc for fixing on walls, poles etc. including all fitting & fixtures, complete all as specified and directed.
All as per item No 131 above but 50 mm bore, complete all as specified and directed.
All as per item No 131 above but 40 mm bore, complete all as specified and directed.
Material and labour for cutting of existing road/ hard standing by providing suitable T&P to make suitable size bore for fixing 50 mm dia pipe in road crossing etc. with and including the cost of making good the disturbed road surface and matching with existing surfaces (Chequered tiles / Road /PCC) etc complete all as specified and directed by Engr-In-Charge
M&L for providing Cable testing van (Fault Finder) for detecting the location of fault in the LT UG cable 1.1 KV of any size complete all as directed by Engr-in-charge.
S&F in replacement for heat shrinkable Straight through jointing kit suitable for LT 1.1 KV XLPE cables 240 to 400 Sqmm 3.5 core including all accessories required at site, complete all as specified and directed.
S&F in replacement for heat shrinkable Straight through jointing kit suitable for LT 1.1 KV XLPE cables 150 to 185 Sqmm 3.5 core including all accessories required at site, complete all as specified and directed.
S&F in replacement for heat shrinkable Straight through jointing kit suitable for LT 1.1 KV XLPE cables 70 to 120 Sqmm 3.5 core including all accessories required at site, complete all as specified and directed..
S&F in replacement for heat shrinkable Straight through jointing kit suitable for LT 1.1 KV XLPE cables 16 to 50 Sqmm 3.5 core including all accessories required at site, complete all as specified and directed.
Supply & Laying in replacement Synthetic Rubber Insulated Mats 2.5 mm thick suitable for Voltage upto 11 KV working pressure conforms to IS 15652-2006 and applying adhesive to fix before laying the new one complete all as specified and directed. Make : Dozz or equivalent make as approved.
Laying only LT underground cable of 3.5 Core 50 Sqmm size, complete all as specified and directed. Note for item no.141 to 145:- (a). Excavation / earthwork, cable protection covers will be measured and paid separately under respective items of BOQ. (b). Cable will be issued under Sch B free for fixing only.
All as per item No 141 above but 3.5 Core 70 Sqmm, complete all as specified and directed.
All as per item No 141 above but 3.5 Core 95 Sqmm, complete all as specified and directed.
All as per item No 141 above but 3.5 Core 150 Sqmm, complete all as specified and directed.
All as per item No 141 above but 3.5 Core 300 Sqmm, complete all as specified and directed.
Supply, fixing, testing and commissioning of aluminium enclosure of 3200 Amps ratings, TPN, aluminium sandwich bus duct, in repair of IP54, IEC 61439-6 , copper contact, dupont mylar insulation class B covered with 2 layers of myler insulation suitable for indoor installation including connection with terminal with all accessories as required complete , copper laminated flexible connections, phase crossover, bends, adopter box, bus bar supports, insulating materials all mounting accessories as per site requirement complete. All bus bar joints shall have double headed bolt on connection plate, bus bar joints shall have colour coded thermal indicator to indicate any excessive temperature rise at joints and other insulating material as per OEM complete all as specified and as directed by Engr-in-Charge. Make- L&T or equivalent in Legrand/ABB/Schenider
Supply, fix, test and commissioning of aluminium enclosure of 3200 Amps ratings, TPN, aluminium sandwich bus duct, in repair of IP54, IEC 61439-6 , copper contact, dupont mylar insulation class B covered with 2 layers of myler insulation suitable for outdoor installation including connection with terminal with all accessories as required complete , copper laminated flexible connections, phase crossover, bends, adopter box, bus bar supports, insulating materials all mounting accessories as per site requirement complete. All bus bar joints shall have double headed bolt on connection plate, bus bar joints shall have colour coded thermal indicator to indicate any excessive temperature rise at joints and other insulating material as per OEM complete all as specified and as directed by Engr-in-Charge. Make- L&T or equivalent in Legrand/ABB/Schenider
Supply, fix, test and commissioning of aluminium enclosure of 2500 Amps ratings, TPN, aluminium sandwich bus duct, in repair of IP54, IEC 61439-6 , copper contact, dupont mylar insulation class B covered with 2 layers of myler insulation suitable for indoor installation including connection with terminal with all accessories as required complete , copper laminated flexible connections, phase crossover, bends, adopter box, busbar supports, insulating materials all mounting accessories as per site requirement complete. All busbar joints shall have double headed bolt on connection plate, bus bar joints shall have colour coded thermal indicator to indicate any excessive temperature rise at joints and other insulating material as per OEM complete all as specified and as directed by Engr-in-Charge. Make- L&T or equivalent in Legrand /ABB/Schenider
S&F in repair Automatic transfer switch 125 Amps rating in existing panel as per existing and taking out unserviceable ATS complete all as specified and as directed. Make- L&T or equivalent in Legrand /ABB / Schenider
S&F in repair Automatic transfer switch 200 Amps rating in existing panel as per existing and taking out unserviceable ATS complete all as specified and as directed. Make- L&T or equivalent in Legrand/ABB/Schenider
S&F in repair Automatic transfer switch 400 Amps rating in existing panel as per existing and taking out unserviceable ATS complete all as specified and as directed. Make- L&T or equivalent in Legrand/ABB/Schenider
S&F in repair Automatic transfer switch 500 Amps rating in existing panel as per existing and taking out unserviceable ATS complete all as specified and as directed. Make- L&T or equivalent in Legrand/ABB/Schenider
Supply and Fix in replacement of MCCB 63 Amps to 100 Amps,16 KA, 3 Pole, 415V complete all as specified and directed by Engr-in-Charge. Make - Legrand/L&T/Siemens
Supply and Fix in replacement of MCCB 63 Amps to 100 Amps,16 KA, 4 Pole, 415V complete all as specified and directed by Engr-in-Charge. Make - Legrand/L&T/Siemens/schnider
Supply and Fix in replacement of MCCB 125 Amps,16 KA, 3 Pole, 415V complete all as specified and directed by Engr-in-Charge. Make - Legrand/L&T/Siemens/schnider
Supply and Fix in replacement of MCCB 125 Amps,16 KA,4 Pole, 415V complete all as specified and directed by Engr-in-Charge. Make - Legrand/L&T/Siemens/schnider
Supply and Fix in replacement of MCCB 160 Amps, 25 KA, 4 Pole, 415V complete all as specified and directed by Engr-in-Charge. Make - Legrand/L&T/Siemens/schnider
Supply and Fix in replacement of MCCB 200 Amps, 25 KA, 3 Pole, 415V complete all as specified and directed by Engr-in-Charge. Make - Legrand/L&T/Siemens/schnider
Supply and Fix in replacement of MCCB 200 Amps, 25 KA, 4 Pole, 415V complete all as specified and directed by Engr-in-Charge. Make - Legrand/L&T/Siemens/schnider
Supply and Fix in replacement of MCCB 250 Amps, 25 KA, 3 Pole, 415Vcomplete all as specified and directed by Engr-in-Charge. Make - Legrand/L&T/Siemens/schnider
Supply and Fix in replacement of MCCB 250 Amps, 25 KA, 4 Pole, 415V complete all as specified and directed by Engr-in-Charge. Make - Legrand/L&T/Siemens/schnider
Supply and Fix in replacement of MCCB 400 Amps, 36 KA,3 Pole, 415V complete all as specified and directed by Engr-in-Charge. Make - Legrand/L&T/Siemens/schnider
Supply and Fix in replacement of MCCB 400 Amps,36 KA, 4 Pole, 415V complete all as specified and directed by Engr-in-Charge. Make - Legrand/L&T/Siemens/schnider
S & F in replacement of Aluminium Tube terminals (Lugs) suitable for 10 Sqmm cable, heavy duty by opening LT Cable from Panel and Crimping /fixing the Lugs with crimping tools and re-terminated the same LT Cable to existing MCB / MCCB according to existing system including taking down old one, complete all as specified and directed.
All as per item No. 164 Above but 16 Sqmm, complete all as specified and directed.
All as per item No. 164 Above but 25 Sqmm, complete all as specified and directed.
All as per item No. 164 Above but 35 Sqmm, complete all as specified and directed.
All as per item No. 164 Above but 50 Sqmm, complete all as specified and directed.
All as per item No. 164 Above but 70 Sqmm, complete all as specified and directed.
All as per item No. 164 Above but 95 Sqmm, complete all as specified and directed.
All as per item No. 164 Above but 120 Sqmm, complete all as specified and directed.
All as per item No. 164 Above but 150 Sqmm, complete all as specified and directed.
All as per item No. 164 Above but 185 Sqmm, complete all as specified and directed.
All as per item No. 164 Above but 240 Sqmm, complete all as specified and directed.
All as per item No. 164 Above but 300 Sqmm, complete all as specified and directed.
All as per item No. 164 Above but 400 Sqmm, complete all as specified and directed.
S & F in replacement of Copper tube terminals (Lugs), suitable/compatible to 4 to 16 Sqmm Cu stranded LT Power cable including Disconnecting the Power Cable from LT Panel / MDB etc and reconnecting the same according to existing system after change of Cu Lugs etc complete all as specified and directed
S & F in replacement of Copper tube terminals (Lugs), suitable/compatible to 25 Sqmm Cu stranded LT Power cable including Disconnecting the Power Cable from LT Panel / MDB etc and reconnecting the same according to existing system after change of Cu Lugs etc complete all as specified and directed
M&L for Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/ pipe or fixed to poles or any other indicated situation for loop earthing etc as required for 32x6 Copper strip, complete all as specified and directed.
Supply, laying, testing and commissioning of 4 Core x 25 Sq.mm XLPE insulated, and overall PVC sheathed, armoured, (Heavy duty) Copper conductor cables suitable for working voltage up to and including 1100 Volts, laid and tied on overhead cable trays; or laid and tied over MS supports in masonry trenches including providing MS supports and clamps for fixing to supports or buried in ground including termination with single compression brass glands, complete all as specified and as directed. Note:- Excavation & earth work shall be measured and paid separately under respective items of BOQ
All as per item No. 180 Above but 4 Core x 16 Sq.mm "CU"
All as per item No. 180 Above but 4 x 10 Sq.mm "CU", complete all as specified and as directed.
All as per item No. 180 Above but 2 Core x 10 Sq.mm "CU", complete all as specified and as directed.
All as per item No. 180 Above but 2 Core x 6 Sq.mm "CU", complete all as specified and as directed.
Supply only Insulation tape roll size 18mm width and 6.5 Mtr length of superior quality complete all as directed. Make- Anchor / Steelgrip
Supply only Lock for panels with 3 keys of superior quality as per sample approved by engr-in-charge complete all as directed. (Make -Godrej Nav-tal 7 Lever Shut Height 5cm (50mm) (3 Keys))
Supply, laying, testing and commissioning of Single Core 35 Sq.mm "CU" armoured for earthing laid and tied on overhead cable trays; or laid and tied over MS supports in masonry trenches etc. complete all as specified and as directed.
M&L for running welding of thickness n.exc. 6mm in repairs to panels etc complete all as directed by Engr-in-charge.
TULAJA ENTERPRISES
RELIABLE ENTERPRISES
PROLINK COMPUTERS
Adinath Technical Services
PURVA ELECTRICALS AND ENGINEERS
Rama Electricals
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .