EXECUTIVE ENGINEER FTR HQ BSF GUWAHATI
FTR HQ BSF GUWAHATI
Construction of 05 Nos ACP Shelter in AOR of BOPs West Chamta,Dhumerkata,Chitrakoot,Barther,Padma and 02 Nos OP Shelter G1 in AOR of BOPs WestChamta,Chitrakoot and 03 Nos OP Shelter G2 in AOR of BOPs SheeshRam,Nauhati and Chitrakoot in AOR of 75 BN
2023_BSF_743159_1
18/Elect/FTR-GHTY/2022-23
Open Tender
Electrical Works
Item Rate
365 days
ENGG BRANCH SHQ BSF GPR
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹0
₹37,731
ENGG BRANCH SHQ BSF GPR
22 Mar 2023
1 Mar 2023
15 Mar 2023
1 Mar 2023
14 Mar 2023
1 Mar 2023
1 Mar 2023 - 14 Mar 2023
7 Mar 2023
Amount
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required.
Group C
Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required
2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
Supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 2 Nos 3 pin 5/6 amps modular socket outlet and 2 Nos 5/6 amps modular switches, connection etc. as required. (For light plugs to be used in non residential buildings)
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.
Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required.
Supplying and fixing brass batten/ angle holder including connection etc. as required.
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
6 Way double door
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Single pole
Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
40 Amp, Double pole
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required.
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required.
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required.
Jointing copper / G.I. tape (with another copper/ G I tape, base of the finial or any other metallic object) by riveting / nut bolting/ sweating and soldering etc as required.
Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required. (For horizontal run)
Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required. (For vertical run)
Providing and fixing testing joint, made of 20 mm X 3 mm thick G.I. strip, 125 mm long, with 4 nos. of G.I. bolts, nuts, chuck nuts and spring washers etc. complete as required.
Supplying and laying of 63 mm dia (OD-63 mm & ID-51 mm nominal) size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc. , complete as required.
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 2 X25 sq. mm (22mm)
Providing and laying one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of following size direct in the existing RCC/ HUME/ METAL pipe as required. 2 X 25 Sq mm.
Providing, laying and fixing 50 mm dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc as required
Providing and fixing LED lamp, 9/10W suitable for single phase, 50 Hz AC , including connection (Make- Havells-Havells, LED ADORE PLUS 9W E27 CDL 3 STAR LAMP or equivalent specification of Make-Philips/Crompton) on existing lamp holder etc as required.
Supplying, Installation, testing & Commissioning of 18/20 W LED Tube Light (Make-Havells-Havells-LUMILINE PLUS NEO or equivalent specification of Make- Crompton/Philips/ SYSKA /Wipro) directly on ceilling / wall including connection with 1.5 sq mm FRLS PVC insulated copper conductor single core cable, earthing etc. as required.
Supplying, Installation, testing and commissioning of pre-wired, 10 WATT LED MIRROR LIGHT, 6500 K, Make-HAVELLS- E-LITE LED PRIDE PLUS NEO or equivalent specifications of make- Philips/Crompton) , complete with all accessories and tube etc. directly on ceiling/ wall, including connection with 1.5 sq. mm FR PVC insulated, copper conductor, single core cable and earthing etc. as required.
Supplying, Installation, testing and commissioning of 1200 mm sweep, White, double ball bearing ceiling fan, including wiring the down rods of standard length (upto 30 cm) including providing and fixing phenolic laminated sheet cover on the fan box etc. as required.(Make-Orient Electric, Rapid Air or equivalent specification of Make-Havells/Khaitan/Polar/Usha/C&G).
Supplying and installation of Exhaust fan, Light Duty Type, 300 mm sweep, Single Phase 240 V AC including making the hole by cutting the wall to suit the size of the above fan , connection, testing, commissioning etc. as required. (Make-Orient-Spring Air Exhaust or equivalent specification of Make-Havells/Usha/Philips/Luminous)
Providing and fixing LED Surface Light, 18 W, 6500 K suitable for single phase, 50 Hz AC , including connection (Havells-Trim Clipon LED Panel Round, Model No.LHEAABP7IN1W018) or equivalent specification of Make-Philips/Crompton) etc as required.
Providing & fixing 1440 Watt, 24 Volt single phase PWM SOLAR power package consisting of 1.5 KVA capacity, 24 V rated solar power conditioning unit, 4x360 Wp Solar PV Module having niminal voltage 24 V, 02 Nos LMCA C-10 rated, 12 V 150 AH tubular solar battery including galvanized iron stand, internal wiring with PVC insulated coppere wire, junction box etc as required. The solar PCU unit should consists of following:- a) Solar charge controller:- Single phase solar charge controllere based on PWM technology, max input PV current 40 A, protection against overcurrent, battery over charge, PV/Battery reverse polarity, reverse current & High temperature b) Invertor : 24 V DC input and 220 V pure sine wave output at rated load 1.5 KVA @ 0.8 PF, efficiency>= 85% c) Grid charger:- I/p voltage range WW 175-285 & NW 190-265+/- 10 V, Grid charging current 13+/-1 A Make- Sukam/Jakson/Tata/UK Solar
Supplying & drawing 2.5 SQMM Flat Three core PVC insulated & PVC sheathed industrial cable 1100 Volts for feeding submersible pump through pump starter ( Havells/Finolex/ Polycab)
Providing, assembling & lowering 1-1/4", 3 meter length upvc column pipe (standard type) suitable for submersible pump including providing O ring at both ends. The upvc column pipe should conform to following specification:- 42 mm OD (1-1/4" DN), Ultimate breaking load>= 2550 kg, safe allowable hydrostatic pressure 25 kg/cm^2 Make- Prakash/Ashirwad/Astral
Supplying & fixing single phase starter in sheet enclosure on surface /recess suitable for 1 HP submersible pump with inbuilt relay range 9-14 A and suitable rating contactor. Make- L&T/Havells/C&S
Providing & fixing suitable size pump guard set between bottom adapter & bottom pipe including SS flange set, PVC SM piece and min 19 mm dia SS rod set with GI nut bolts including O rings etc as required. Make- Astral/ Ashirwad/Prakash
Supplying, fixing & lowering 1 HP Submersible pump, 10 stage having maximum outer dia 98 mm suitable for 4" borewell, 1-1/4" outlet dia with deliuevery capacity >= 45 LPM at hed of 38 meter. Make- Kirloskar KS4 series B10B10/equivalent model in CRI/Crompton greaves
SITC of wall fan 400 mm sweep Usha make Model WF 400 MM MAXX AIR ICY WALL FAN or equivalent make/model Havells/CG/Almonard with all accessories, including wiring with 1.5 Sq.mm FRLSH PVC insulated, copper conductor, single core cable etc as required.
AMIT MAITRA
UJJAL KUMAR BISWAS
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .