Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.7 LAccepted-AOC 02 PADRI SHIV NAGAR SHIV NAGAR MAHARAJGANJ UTTAR PRADESH 273303 | MAHARAJGANJ | UTTAR PRADESH | 273303 | L1 | Accepted-AOC Being overall rate reasonable | |
| 2 | L2₹33.8 L+₹13,060 (0.39%)Rejected-Finance | L2 | Rejected-Finance Not lowest bidder | |
| 3 | L3₹38.5 L+₹4.8 L (14.3%)Rejected-Finance 24 25 MANGAL ARCADE TELCO ROAD OPP HOTEL DOUBLE TREE MOHAN NAGAR CHINCHWAD PUNE 411019 | PUNE | MAHARASHTRA | 411019 | L3 | Rejected-Finance Not lowest bidder | |
| 4 | L4₹39.2 L+₹5.5 L (16.4%)Rejected-Finance GATE NO 454 01 TAPKIR NAGAR PUNE NASIK HIGHWAY NEAR GANDHARV NAGARI MOSHI PUNE 412 105 | PUNE | MAHARASHTRA | 412105 | L4 | Rejected-Finance Not lowest bidder | |
| 5 | L5₹39.8 L+₹6.2 L (18.4%)Rejected-Finance | L5 | Rejected-Finance Not lowest bidder |
Tender Value
₹49 L
EMD Value
₹98,000
Closing Date
1 Jan 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (CENTRAL) KIRKEE
GE (CENTRAL) KIRKEE, RANGE HILLS ROAD KIRKEE PUNE-411003
COMPREHENSIVE REPAIR MAINTENANCE OF LT ELECTRIC DISTRIBUTION LINES PANELS AND ALLIED WORKS AT TB II AND STREET LIGHT SECURITY LIGHTS ALONG WITH CONNECTED ACCESSORIES UNDER AGE EM I UNDER GE CENTRAL KIRKEE
2021_MES_492634_1
8561/E8 OF 2021-2022
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
DIGHI AND KIRKEE
AS PER NIT
7 documents required · 7 mandatory
₹500
Yes
GE (CENTRAL) KIRKEE
₹98,000
Yes
11 Feb 2022
4 Dec 2021
3 Jan 2022
4 Dec 2021
1 Jan 2022
20 Dec 2021
4 Dec 2021 - 18 Dec 2021
60 days
Amount
Excavation in trenches n.exc 1.5m wide and n.exc 1.5m in depth for laying of pipe and getting out in soft loose soil complete all as specified and as directed by Engineer in charge.
Excavation in trenches n.exc 1.5m wide and n.exc 1.5m in depth for laying of pipe and getting out in soft disintegrated rock complete all as specified and as directed by Engineer in charge.
Returning, filling in including spreading, levelling, watering and well ramming in layers n.exc 25cm thick complete all as specified and as directed by Engineer in charge.
Removing of excavated material n.exc 50m and depositing where directed at a level n.exc 1.5m above the starting point complete all as specified and as directed by Engineer in charge.
Material & Labour for PCC (1:3:6) type C-2 using 40mm graded aggregate as in foundation for filling in, mass concrete for foundation of Pole, Transformer, Panel board, stay, post top lantern, repairs to road cutting, drain, path etc complete all as specified and directed by Engineer in charge.
Material & Labour for PCC (1:2:4) type B-1 using 20mm graded aggregate as in coping of new pole / reconstruction old damaged copings etc, including necessary form work complete all as specified and directed by Engineer in charge.
Material & Labour for stone dust for cushioning of UG cable/ at cable trenches inside substation bulding etc. complete all as specified and directed by Engineer in charge.
Material & Labour for brick protection with sub class 'B' brick for UG cable all as specified and directed.
Dismantling taking out carefully old/unserviceable UG cable any type any size from trenches/poles/ducts/LT panels after dismentling ends from OH conductors/MCCBs/joint boxes for relaying/refixing or carrying to store for Sch of Credit complete all as specified and directed by Engineer in charge.
Material and labour for fixing or passing through pipe, laid in trenches or fixed to pole/wall or fixed to LT panel board, 1100 volts grade heavy duty cable with PVC insulated stranded aluminium conductor served with inner sheathing of PVC tape, armoured with galvanised steel wire or tape and overall PVC sheathed 6 sqmm 2 core with required aluminium cable lugs complete all as specified and directed by Engineer in Charge.
All as per item No. 10 here-in-before but 10sqmm 2 core complete all as specified
All as per item No. 10 here-in-before but 16sqmm 2 core complete all as specified
All as per item No. 10 here-in-before but 10sqmm 4 core complete all as specified
All as per item No. 10 here-in-before but 16sqmm 4 core complete all as specified
All as per item No. 10 here-in-before but 25sqmm 3.5 core complete all as specified
All as per item No. 10 here-in-before but 35sqmm 3.5 core complete all as specified
All as per item No. 10 here-in-before but 50sqmm 3.5 core complete all as specified
All as per item No. 10here-in-before but 70sqmm 3.5 core complete all as specified
All as per item No. 10 here-in-before but 95sqmm 3.5 core complete all as specified
All as per item No. 10here-in-before but 120sqmm 3.5 core complete all as specified
Dismantling taking out broken/worn out steel pole of 8.5 to 9.0 mtr long and keeping aside for refixing or carrying to store for credit complete all as specified and directed by Engineer in charge.
Material & Labour for steel tubular swaged pole complete with cast iron base plate , finial taper plug bolts nuts and screws confirming to IS : 2713 and made out of structural steel tube confirming to IS: 1161 and painted internally with a coat of bituminous paint and externally one primer coat, one under coat and one finishing coat of aluminium paint as specified type 410 SP-31 (9 mtr long) complete all as specified and as directed by Engineer in Charge.
Dismantling and taking down old/unsv cross arms, bracing, supports etc complete for reuse at site or carrying to store for sch of credit all as specified and directed by Engineer in Charge.
Matertial & Labour for cross arms bracings supports clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding bending cold or hot, drilling holes for bolts in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of aluminium paints complete all as specified and directed by Engineer in Charge.
Dismantling and taking down old/unsv ACSR conductor any size complete for reuse at site or carrying to store for Sch of Credit complete all as specified and directed by Engineer in charge.
Material & Labour for ACSR conductor including jointing with existing conductor and straining on LT pole and proper fastening to pin/shackle insulators with aluminium binding wires and required jumpering connection complete all as specified and directed by Engineer in charge.
Dismantling and taking down old/unsv insulator of any type any size from pole/stay for reuse at site or carrying to store for sch of credit complete all as specified and directed by Engineer in Charge.
Material & Labour for pin type, porcelain, vitreous, brown, including one galvanised mild steel spindle, two galvanised iron washer and one galvanised iron nut, 100mm height and 65 mm dia for 1100 volts grade complete all as specified and directed by Engineer in charge.
Material & Labour for shackle type,porcelian vitreous white, brown or green insulator including galvanised mild steel straps , washers, insulators bolts ,washer and nuts of size 100 mm height and 115 mm dia for 1100 Volts grade complete all as specified and directed by Engineer in Charge.
Material & Labour for Loop type insulator, porcelian vitreous brown of size 65x90mm and clearence hole 16mm complete all as specified and directed by Engineer in Charge.
Material & Labour for Stay assembly using 16mm dia galvanised rod complete all as shown in electrical plate No 1 of SSR Part I incl dismantling unsv one complete all as specified and directed by Engineer in Charge. Note:-Clamps, loop insulator, earth work, PCC required for work shall be measured and paid separately under relevant item of this schedule.
Material & Labour for stay wire using galvanised steel strand of 7/3.15mm complete with necessary binding including dismantling taking down unserviceable one complete all as specified and directed by Engineer in Charge.
Supply & Fix cradle hexagonal /rectangular fabricated with galvanised steel wire not less than 4mm dia on pole including dismantling taking out unsv cradle guard complete all as specified and as directed by Engineer in Charge.
Supply & Fix earth continuity wire using GI wire not less than 4mm dia on pole including dismantling taking out unsv GI wire complete all as specified and as directed by Engineer in Charge.
Material & Labour for Earthing complete with galvanised steel pipe electrode, 40mm bore, medium grade, 6.00 mtr long buried directly and vertically in ground with top edge at ground level after making bore hole of size not less than 300 mm dia and 6.0 Mtr long using suitable mechanical drilling rig (for drilling near the specified location), connected with galvanised steel earthing lead of 25x4 mm all as shown in Plate No-2, connected to the earthing test point, concrete pit in PCC 1:3:6 type C-2with pit cover, funnel, wiremesh, 32 mm dia light grade GI tubing for protection of GI strip 25x4mm, charcoal and salt in alternate 150mm thick layers around GI earth pipe, including necessary returning filling in & removal all as specified or indicated in SSR Part-I, including testing to achieve earth resistance value as per IS specification on completion complete all as specified and as directed by Engineer in Charge.
Material & Labour for restraining of overhead ACSR conductor of any size of 4 wire 35-45 meter span on pole after disconnecting all jumpering connection & binding of insulators and redoing all jumpering connection and insulator binding with aluminium conductor including providing required T&P complete all as specified and directed by Engineer in Charge.
Material & Labour for restraining of ACSR conductor of any size of 2 wire 35-45 meter span on pole after disconnecting all jumpering connection & binding of insulators and redoing all jumpering connection and insulator binding with aluminium conductorincluding providing required T&P complete all as specified and directed by Engineer in Charge.
Material & Labour for restraining of GI Cradle guard hexagonal/rectangular of any size 35-45 meter span on pole after disconnecting all binding on cross arms and redoing all bindings providing required T&P complete all as specified and directed by Engineer in Charge.
Material & Labour for restraining of GI earth wire of any size 35-45 meter span on pole after disconnecting all binding on cross arms and redoing all bindings providing required T&P complete all as specified and directed by Engineer in Charge.
Material & Labour for Cutting/Trimming of tree branches arround 3.00 meter distance from conductors of HT over head line of span up to 50 meters including removing of creepers etc from poles complete all as specified and directed by Engineer in Charge.
Material & Labour Cutting/Trimming of tree branches arround 3.00 met distance from conductors of LT over head line of span up to 40 meters including removing of creepers etc from poles complete all as specified and directed by Engineer in Charge.
Supply & Fix sheet metal enclosure of size 40cmx30cmx40cm made out of 3mm thick MS sheet hinged door and locking arrangements and painting (inside and outside) with epoxy powder coated including fixing in position with and including following accessories internally pre wired and testing complete all as specified and as directed by Engineer in Charge.:- (a) Time switch, MaxiRex 4QT-daily, 240V, AC, base mounting, Legrand 6499-15 – 01 No. (b) 3 pole power contactors, type ML-3 of L&T or equivalent – 01 No. (c) Toggle switch, single pole 2 way - 01 No. (d) bakelite base brass terminal connector block 8 way 40 amps cap-1 No, (e) MCB TP 40 amps of Legrand/L&T-1No and fixed to pole/wall with clamp, nuts, bolts washers and testing complete including dismantling taking down unserviceable switch fuse complete all as specified and directed by Engineer in Charge.
Supply & Fix Heat shrink end joint indoor/outdoor LT 1100 volts grade 10-16 sqmm, 4 core, make-Raychem, Cat No-EPKT0003 or equivelent of M-Seal/3M as approved by GE.
Supply & Fix Heat shrink end joint indoor/outdoor LT 1100 volts grade 25-50 sqmm, 3.5 core, make-Raychem, Cat No-EPKT0019 or equivelent of M-Seal/3M as approved by GE.
Supply & Fix Heat shrink end joint indoor/outdoor LT 1100 volts grade 70-150 sqmm, 3.5core, make-Raychem, Cat No-EPKT0035 or equivelent of M-Seal/3M as approved by GE.
Supply & Fix Heat shrink end joint indoor/outdoor LT 1100 volts grade 185-300 sqmm, 3.5 core, make-Raychem, Cat No-EPKT0051 or equivelent of M-Seal/3M as approved by GE.
Supply & Fix Heat shrink straight through joint out door type LT 1100 volts grade 10-16 sqmm, 4 core, make-Raychem, Cat No-EPKJ0123 or equivelent of M-Seal/3M as approved by GE.
Supply & Fix Heat shrink straight through joint outdoor type LT 1100 volts grade 25-50 sqmm, 3.5 core, make-Raychem, Cat No-EPKJ0130 or equivelent of M-Seal/3M as approved by GE.
Supply & Fix Heat shrink straight through joint outdoor type LT 1100 volts grade 70-150 sqmm, 3.5 core, make-Raychem, Cat No-EPKJ0137 or equivelent of M-Seal/3M as approved by GE.
Supply & Fix Heat shrink straight through joint outdoor type LT 1100 volts grade 185-300 sqmm, 3.5 core, make-Raychem, Cat No-EPKJ0144 or equivelent of M-Seal/3M as approved by GE.
Material & Labour for Painting of steel pole any type up to 7.5 met height above ground level including cross arms,clamps,stay clamps etc with two coats of aluminium paint after surface preparation complete all as specified and as directed by Engr-In-Charge
Material & Labour Numbering of HT/LT poles serially with letter/number size width and height up to 40 mm in situ with white paint on black back ground by Epoxy Paint complete all as specified and as directed by Engr-In-Charge
Material & Labour GI tubing light grade 40mm bore,on pole /wall with necessary clamps,nuts,bolts and washers/under road cross ISI marked, for cable protection including taking out old pipes complete all as specified and directed by Engineer in Charge.
Material & Labour GI tubing light grade 50mm bore on pole /wall with necessary clamps,nuts,bolts and washers/under road cross ISI marked, for cable protection, ISI marked, for cable protection including taking out old pipes complete all as specified and directed by Engineer in Charge.
Material & Labour GI tubing light grade 80mm bore,on pole /wall with necessary clamps,nuts,bolts and washers/under road cross ISI marked, for cable protection ISI marked, for cable protection including taking out old pipes all as specified and directed by Engineer in Charge.
Material & Labour for jumper connections of length up to 1.50 meter with existing size and guage of ACSR, binding with existing conductors for LT OH lines complete as directed by the Engr-In-Charge.
Material & Labour for Danger notice plate of 1.6mm thick MS sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in singal red colour and fixed with MS clamps, bolts and nuts of approved size, for LT 1100 volts, 25 x 20 cm size including taking out defective danger boards complete all as specified and directed by Engineer in Charge.
Material & Labour for Danger notice plate of 1.6mm thick MS sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in singal red colour and fixed with MS clamps, bolts and nuts of approved size, for HT 11000 volts, 25 x 20 cm size including taking out old danger boards all as specified and directed by Engineer in Charge.
Supply and errect Cast Iron HT/LT cable route indicator round shaped 120 mm dia 8 mm thick duly embossed with MES HT/LT Cable fixed on flat iron 25X3 mm thick 300 mm long and grouted in PCC complete all as specified and directed by Engineer in Charge. Note:- PCC required for work shall be measured and paid separately under relevant item of this schedule.
Taking down defective HP SV/HP MV/MH/LED street light fittings any type,any capacity from 7.5 to 9 met height poles and bringing down to ground,carry out necessary repair work including replacement of defective spares required, testing on ground and refixing in its original position to the entire satisfaction of Engr-In-Charge. Note : i) spares required for the repairs will be measured and paid seperately under relevant items of this schedule. ii) amount towards small items such as clamps,nut,bolts and washers are deemed to be inclusive in quoted rates.
Supply and replacement of ballast-70 watts suitable for HPsv lamps complete all as specified and as directed by Engineer in Charge.
Supply and replacement of ballast-150/250 watts suitable for HPsv lamps complete all as specified and as directed by Engineer in Charge.
Supply and replacement of Porcellin Holder screw type suitable for HP sv lamp 70/150/250 watts complete all as specified and as directed by Engineer in Charge.
Supply and replacement of Ignitor suitable for HP sv lamp 70/150/250 watts complete all as specified and as directed by Engineer in Charge.
Supply and replacement of High pressure sodium vapour lamp 70 Watts complete all as specified and as directed by Engineer in Charge.
Supply and replacement of High pressure sodium vapour lamp 150/250 Watts complete all as specified and as directed by Engineer in Charge.
Supply and replacement of PVC flexible twisted cable 1.5 sqmm 2 core stranded copper conductor complete all as specified and as directed by Engineer in Charge.
Supply and fix LED driver suitable for 45 watt LED security light including taking out defective driver any type complete all as specified and as directed by Engineer in Charge.
Supply and fix LED driver suitable for 25 watt LED security light including taking out defective driver any type complete all as specified and as directed by Engineer in Charge.
Supply and fix LED driver suitable for 20/15 watt LED security light including taking out defective driver any type complete all as specified and as directed by Engineer in Charge.
Supply & Fix LED security fitting 45 watt with LED driver and lens complete with bracket made of 25/32 mm GI Pipe Light grade,clamps,nut,bolt and washers. Including taking out defective street light of any type/size complete all as specified and as directed by Engineer in Charge.
Supply & Fix LED security fitting 60 watt with LED driver with lens complete with bracket made of 25/32 mm GI Pipe Light grade,clamps,nut,bolt and washers including taking out defective street light of any type/size complete all as specified and as directed by Engineer in Charge.
Supply & Fix LED security fitting 25 watt with LED driver with lens complete complete with bracket made of 25/32 mm GI Pipe Light grade,clamps,nut,bolt and washers including taking out defective street light of any type/size complete all as specified and as directed by Engineer in Charge.
Supply & Fix LED security fitting 90 watt with LED driver complete complete with bracket made of 25/32 mm GI Pipe Light grade,clamps,nut,bolt and washers including taking defective street light of any type/size complete all as specified and as directed by Engineer in Charge.
Supply & Fix LED post top lantern fitting 20 Watts complete including out defective light of any type/size complete all as specified and as directed by Engineer in Charge.
Supply & Fix LED flood light fitting 50 watt complete make:surya LUMOS MAX Model SLE FL 50 or Equivalent make in Bajaj/HPL/philips out defective light of any type/size complete all as specified and as directed by Engineer in Charge.
Supply & Fix LED flood light fitting 100 watt complete make: surya or Equivalent make in Bajaj/HPL/philips out defective light of any type/size complete all as specified and as directed by Engineer in Charge.
Supply & Fix time switch dial type suitable for pannel mounting including taking out old and unservicable time switch any type any size.
Supply & Fix for 3 pole contactor ML-02 to ML-O5 with auxilary contact 2NO+2NC coil 240 volts,50 HZ up to 415 volt 50/60 HZ make L&T.
Sahara Engineers
metro electrical services
ONKAR ELECTRIC AND GENERAL STORE
MANGAL ELECTRICAL STORES
Adinath Technical Services
ASHWAMEDH ENGINEERS
Mahindra Electric Stores
SOURABH ENGINEERS
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .