Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.2 CrAccepted-AOC | ₹14.2 Cr Quoted ₹14.3 Cr | L1 | Accepted-AOC Being L1 |
| 2 | L2₹14.7 CrRejected-Finance 1095 ELDECO 2 UPHAAR SECTOR 3 RAIBAREILLY ROAD LUCKNOW UP PIN 226002 | LUCKNOW | LUCKNOW | UTTAR PRADESH | 226002 | ₹14.7 Cr | L2 | Rejected-Finance Being other than L1 |
| 3 | L3₹14.9 CrRejected-Finance | ₹14.9 Cr | L3 | Rejected-Finance Being other than L1 |
| 4 | L4₹15.4 CrRejected-Finance | ₹15.4 Cr | L4 | Rejected-Finance Being other than L1 |
| 5 | L5₹15.9 CrRejected-Finance | ₹15.9 Cr | L5 | Rejected-Finance Being other than L1 |
Tender Value
₹13.1 Cr
EMD Value
₹9.8 L
Closing Date
6 Nov 2024, 6:00 pmClosed
Chief Enginner Lucknow Zone , Lucknow
Headquarter Chief Engineer Lucknow Zone, 17 Carriappa Marg Post Dilkusha, Lucknow Cantt PIN -226002
PROVISION OF 12 X JCOS AND 48 X ORS DEFI MD ACCN AT NEW CANTT PRAYAGRAJ
2024_MES_675736_1
CELZ/PRJ/T-02 OF 2024-25
Open Tender
Civil Works
720 days
Prayagraj
AS per NIT
8 documents required · 8 mandatory
₹3,000
GE(West) Prayagraj
₹9.8 L
23 Dec 2024
20 Sept 2024
13 Nov 2024
20 Sept 2024
6 Nov 2024
23 Oct 2024
Amount
Sch 'A' Part-I (Building Work) Note : This schedule is pre-priced by MES and the pre-priced rate indicated are under Col. 5.
Total amount of Sch 'A' Part II (Site clearance, excavation and earth work)
Total amount of Sch 'A' Part III (Internal Water Supply )
Total amount of Sch 'A' Part IV (Internal Electrification)
Total amount of Sch 'A' Part V (Road, Path & Culvert)
Total amount of Sch 'A' Part VI (Area Drainage)
Total amount of Sch 'A' Part VII (Sewage Disposal)
Total amount of Sch 'A' Part VIII (External Water Supply )
Total amount of Sch 'A' Part IX (External Electrification)
Sch 'A' Part - X (Miscellaneous Items for B/R & E/M Works) Note - This Schedule is not pre-priced by MES and the pre - priced rate indicated as "Rs 0.00 under col.5 siginifies this fact only.
Internal Water Supply S&F Angle valves ,15mm, cast copper alloy, fancy type, CP, screwed down, high pressure, with crutch or butterfly handle,screwed both ends for iron pipe or for union and fixed. complete all as specified and directed.
S&F chromium plated wall mixer L band 15 mm , cast copper alloy, fency type, chromium plated, screwed down high pressure with or without lettered ‘Hot’ ot ‘Cold’ with long screwed shanks anf fly nuts screwed for union pipe complete all as specified and directed.
S&F chromium plated central Hole basin mixer 15 mm, cast copper alloy, fency type, chromium plated, screwed down high pressure with or without lettered ‘Hot’ ot ‘Cold’ with long screwed shanks anf fly nuts screwed for union pipe complete all as specified and di-rected.
S&F chromium plated sink mixer 15 mm, cast copper alloy, fency type, chromium plated, screwed down high pressure with or without lettered ‘Hot’ ot ‘Cold’ with long screwed shanks anf fly nuts screwed for union pipe complete all as specified and directed.
S&F health faucent (1.5 m long tube) with hook (hand spray) with CP body of 15 mm bore & fixed, complete all as specified and directed.
S&F swivel CP shower rose of 150 mm dia with arms 15 mm size not less than 150 mm long with bend of 45 degree with flange complete all as specified and directed.
INTERNAL ELECTRIFICATION M&L for Point wiring complete for One light/Fan/Exhaust Fan/Bell point controlled by one switch with PVC insualted and unsheathed FRLSH cable 1.5 Sqmm (nominal area) ISI marked, multi-stranded copper conductor single core including ISI marked 20 mm dia PVC conduit medium grade concealed in wall and heavy duty PVC conduit not less than 20 mm in roof / floor slab and ceiling, suitable for modular switch with modular metal flush box with inner and outer cover plate & frame etc of requied colour complete, including 1.5 Sqmm PVC, FRLSH cable insulated unsheathed copper earth wire to the common earth and connecting to earth dolly, including colour coding of cable shall be Phase-red, Neutral-black and Earth- green with all accessories complete all as specified and directed. Note :-(i) In case of roof/ceiling, heavy duty PVC pipe shall be used without any extra cost.One circuit controlled by max 8 points only. (ii) Modular (switch, Socket,metal box, cover plate ) items measured and paid separately.
M&L for Point wiring complete for One light point controlled by two way switch with PVC insualted and unsheathed FRLSH cable 1.5 Sqmm (nominal area) ISI marked, multi-stranded copper conductor single core including ISI marked 20 mm dia PVC conduit medium grade concealed in wall and heavy duty PVC conduit not less than 20 mm in roof / floor slab and ceiling, suitable for modular switch with modular metal flush box with inner and outer cover plate & frame etc of requied colour complete, including 1.5 Sqmm PVC, FRLS cable insulated unsheathed copper earth wire to the common earth and connecting to earth dolly, including colour coding of cable shall be Phase-red, Neutral-black and Earth- green with all accessories complete all as specified and directed. Note :-(i) In case of roof/ceiling, heavy duty PVC pipe shall be used without any extra cost.One circuit controlled by max 8 points only. (ii) Modular (switch, Socket,metal box, cover plate ) items measured and paid separately.
M&L for power point wiring complete for 5 pin, 5/6 Amps switch socket outlet point on independents board with PVC insulated and unsheathed, FRLSH cable 1.5 sqmm (nominal area), ISI marked, stranded copper conductor single core including ISI marked 20mm dia medium grade PVC conduit concealed in wall and PVC conduit in roof/floor slab, pressed GI concealed terminal boxes not less than 1.6 mm thick of required size and with top cover 3 mm thick of plastic laminated sheets of requied colour complete, including 2.5 Sqmm, FRLS cable PVC insulated unsheathed multi stranded copper earth wire to the common earth and connecting to earth dolly, including colour coding of cable shall be Phase-red, Neutral-black and Earth- green with all accessories and all as specified. Note :- In case of roof/ceiling, heavy duty PVC pipe shall be used without any extra cost.One circuit controlled by max 4 points only.
M&L for Point wiring complete for one 5 Pin 5 Amp switch Socket outlet point on same board, with PVC insualted and unsheathed FRLSH CABLE 1.5 Sqmm (nominal area) ISI marked, multi-stranded copper conductor single core including ISI marked 20 mm dia PVC conduit medium grade concealed in wall and MS conduit not less than 20 mm in roof / floor slab and ceiling, pressed GI concealed terminal boxes not less than 1.6 mm thick of required size and with top cover 3 mm thick of plastic laminated sheets of requied colour complete, including 1.5 Sqmm PVC, FRLS cable insulated unsheathed copper earth wire to the common earth and connecting to earth dolly, including colour coding of cable shall be Phase-red, Neutral-black and Earth- green with all accessories complete all as specified and directed. Note :-In case of roof/ceiling, heavy duty PVC pipe shall be used without any extra cost.
M&L for Point wiring complete for one 15 Amps switch socket outlet point on independents board with PVC insulated and unsheathed, FRLSH cable 2.50 sqmm (nominal area) ISI marked, multi-stranded copper conductor single core including ISI marked 20 mm dia PVC conduit medium grade concealed in wall and heavy duty PVC conduit not less than 20 mm in roof / floor slab and ceiling, pressed GI concealed terminal boxes not less than 1.6 mm thick of required size and with top cover 3 mm thick of plastic laminated sheets of requied colour complete, including 2.5 Sqmm PVC, FRLS cable insulated unsheathed copper earth wire to the common earth and connecting to earth dolly, including colour coding of cable shall be Phase-red, Neutral-black and Earth- green with all accessories complete all as specified and directed. Note :- In case of roof/ceiling, heavy duty PVC pipe shall be used without any extra cost.One circuit controlled by max one points only.
S&F PVC 3 way connector comprising alloy connector on PVC mounting complete all as specified and directed.
S&F modular metal flush box 12 module complete all as specified and directed.
S&F modular metal flush box 08 module complete all as specified and directed.
S&F LED batten Tube light surface / wall mounted with specially designed powder coated aluminum housing, high optically efficient polycarbonate diffuser, in built electronic driver duly wired upto terminal block, power consumption <20W (4 FT 20 W), luminaire lumen >2000 lm, system efficiency of >120 lumens /W, with LED binning as per ANSI Bin C78.377A, photo biological safety report as per IEC624718 & electrical insulation class I, Ingress protection IP 20, colour rendering index CRI>80, temp range 0 to 450C, driver efficency>85%, power factor>0.9, THD <20% as per IEC 61000-3-2, colour temp -6500K, surge protection 2.5 KV, 50000 burning hrs (min) as per L70 criteria, two stages isolated constant current operated driver with range 150-270V AC and seafty extra low voltage safe level <60V DC as per IEC standard with LM79 & LM80 certification.complete all as specified and directed
S&F LED batten Tube Light surface / wall mounted with specially designed powder coated aluminum housing, high optically efficient polycarbonate diffuser, in built electronic driver duly wired upto terminal block, power consumption <10W (2 feet 10 W) luminaire lumen >1000 lm, system efficiency of >120 lumens /W, with LED binning as per ANSI Bin C78.377A, photo biological safety report as per IEC624718 & electrical insulation class I, Ingress protection IP 20, colour rendering index CRI>80, temp range 0 to 450C, driver efficency>85%, power factor>0.9, THD <20% as per IEC 61000-3-2, colour temp -6500K, surge protection 2.5 KV, 50000 burning hrs (min) as per L70 criteria, two stages isolated constant current operated driver with range 150-270V AC and seafty extra low voltage safe level <60V DC as per IEC standard with LM79 & LM80 certification.complete all as specified and directed.
S&F LED Building security light fitting 25 Watt with aluminum pressure die cast housing, high purity PC Fresnel diffuser with silicon gasket for IP-65 protection, power consumption <20 W (24W) & luminaire lumen >2500 lm and system efficiency > 120 lm/W, in built electronic driver prewired upto terminal block with driver efficiency >85% power factor >0.95 as light source with toughened glass including two core flexible copper wire of 1.5 sq mm from ceiling rose to the connector of fitting, connection wires not to be more than 2.5 in length and made out of GI tubing 35/40 mm dia /suitable dia light grade bend to shape security light fitting with necessary MS clamp 25 mm wide and 6 mm in thickness in suitable length not more than 30 CM and max length of pipe 1.5 Mtr long with one code of anti corrosive primer and two coats aluminum paint including nuts, bolts and washers complete all as specified and directed.
Supply, installation, testing and commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with brush less direct current (BLDC) motor, class insulation B, 3 Nos blades, 30/40 Cm long down rod, 2 no canopy, shackle kit, safety rope, copper winding, power factor not less than 0.90 services value (CMM/W) minimum 6.0 Air delivery min 210 CMM, 350 RPM (tolerance as per IS: 3742019) THD less than 10 % without remote and electronic regulator unit for speed control and all remaining accessories including safety pin, nuts, bolts, washers, suitable for 230 V, 50 Hz single phase AC supply earthing etc and connecting up the fan to ceiling rose including PVC insulated three core 23/0.0076 copper cable and suitable size of flexible conduit from celling rose to ceiling fan motor not less than 0.5 mtr long with PVC connector 2 way/3 way for connection and writing MES No. in black synthetic enamel paint/engraving tools etc complete all as specified and directed. Note:- (a) T&P will be provided by the contractor for reaching any height of the building/warehouse/Hanger
M&L Earthing complete with galvanised mild steel earth plate electrode 600 x 600 x 6 mm thick buried directly in ground to a depth not less than 2.25 mtr deep below ground level with top edge of earth plate not less than 1.5 metre below normal ground level surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15 cm all around the plate using GI earth wire 4 mm dia as earth electrode connected to bolts, nuts, check nuts and washers of GI or steel etc at one end and connected to equipment at another end.GI earth wire encased in and including 15 mm dia GI light grade pipe from upper end of earth plate upto equipment 20 dia bore GI pipe light grade as water pipe from earth chamber to upper edge of earth plate, test point, GI funnel with wire mesh fixed on water pipe PCC (1:3:6) type C-1 (using 20 mm graded stone aggregate) as in pit chamber and RCC pit cover slab of 50 mm thick precast RCC (1:1.5:3) type A-1 duly reinforced with MS TMT bars 8 mm dia @ 150 mm c/c both ways with 10 mm dia MS round bar as in lifting handles, excavation earth work including laying the GI pipe concealed in floor/wall all as described in electric plate no 3 of SSR part I complete all as specified and directed and testing on completion. Note:- (i) If the desired earth resistance is not found, earthing shall be redone by the contractor at no extra cost to the department. (ii) Earthing wire beyond 7.5m shall be measured and paid separately.
S&F decorative type wall mounted of LED light 12/15 Watts LED fixture with LED lamp of 15/12 watt and prewaired copper, holder for better light complete all as specified and directed.
Supply and fixing CP connection 450 mm long for hot water outlet supply from geyser complete all as specified and directed.
EXTERNAL WATER SUPPLY Supply, laying, testing and commissioning Ductile Iron pipe, single socket 100 mm bore including Rubber gasket joints, Class K-7 in any length laid in trenches complete all as specified and directed.
Cutting of existing CI tubing of 150 mm dia for alterations or ad-ditions 150x150x100 mm CI tee, CI collar for tapping including necessary excavation and making good the surface complete all as specified and directed.
Construction of fly ash brick masonry valve pit chamber of size 950mm X 950mm X 950mm (internal dimensions) including necessary excavation & earth work, 100 mm thick PCC (1:4:8) type D-2 as in foundation, 230 mm thick fly ash brick work in cement mortar (1:4), 12 mm thick rendering in cement mortar (1:4) on internal surface of valve pit and mild steel sheet cover of 6 mm thick and angle iron of size (50 x 50 x 6) mm frame around of valve pit, sheet welded on all four corners, locking arrangement with pad lock of size 50 mm brass, 6 levers and in duplicate key (Make - Godrej or equivalent make as approved by GE complete) including two coat of approved synthetic enamel paint over one coat of red oxide primer on prepared steel surface complete all as specified and directed.
EXTERNAL ELECTRIFICATION Supply installation, commissioning and testing of transformer copper wound step down 250 KVA outdoor type 11/0.433 KV at no load 3 ph, 4 wire 50 Hz 433 Volts AC with Onan cooled oil immersed copper wounded outdoor type, delta connected on HV side and star connected in LV side in accordance with vector symbol Dyn-11 with neutral brought out on secondary side and having tapping in step + 2.50 % (-) (+) 7.5% to be changed by mean of hand operated OFF load tap changing gear including first fill of transformer oil as per IS 335 and including all fitting accessories as specified in SSR part-I and as per revised (fourth revision) Amendment No -04 Mar 2021 IS-1180, part-I 2014 (level 2) , Energy efficiency level -2 and losses as per IS -1180 Part -I 2014, Revised Amendment No -04 Mar 2021.transformer should have cable end terminal box on LV and HV side, oil temprature gauge, dehydrating breather with first fill of dehydrating agent, oil conservator tank, explosive vent, rating and terminal marking plate, oil level gauge, oil drain and filter valve, providing independent earthing terminal for neutral and body complete with all other standard accessories etc as specified and PCC foundation as per manufauture drawing of transformer all as specified and directed. The transformer shall be complete with the following fittings and accessories:-
Oil conservator tank with filling holes and cap filter type drain valve and oil level gauge- 01 Nos
Silica gel breather with connecting pipe and first fill of dehydrating agent- 01 Nos
Air Release valve plug- 01 Nos
01 No 100mm dia type thermometer vapour pressure type having rating 0-120 degree centigrate with max temp indicator and resetting device incl max reading pointer washers- 01 Nos
Thermometer pocket on tank cover
04 Nos plain solid CI detachable rollers
02 Nos Earthing terminals on tank cover to facilitate GI Earth Strip
Rating plate and terminal marking plate
Two no GI Tubing light grade100 mm dia 60 cm long embedded in brick/wall on LT/HT side for drawing UG Cable
First filling of oil confirming to IS-335 and tested upto 50KV/2.5mm dielectric strength
Lifting lugs/hook
Oil drain valve with plug
Cable end termination boxes on HV and LV sides
Explosive Vent
Name, Rating, Diagram plate- 01 Nos
Off circuit tap changing switch- 01 Nos
Supply and erecting Steel tubular swaged pole complete with cast iron base plate , finial taper plug , bolts , nuts & screws as specified type 410 SP-55, 11.00 mtr long, complete all as specified and shown on drawings including the followings:- (a) Excavation in post holes in any types of soil, returning filling, well ramming and disposal of surplus soil to a distance not exceeding 50 mtr from the starting points. (b) PCC (1:3:6) type C-2 using 40 mm graded stone aggregate as in foundation including form work. (c) PCC (1:2:4) type B-1 using 20 mm graded stone aggregate as in coping including form work. (d) PCC (1:4:8) type D-2 using 40 mm graded stone aggregate as in base. (e) Painting of poles externally with one coat of black bituminous paint (upto planting depth) and above plinth block concrete collar with two coats of aluminium paint over one coat of red oxide primer including preparation of surface including painting of 30 cm wide bands 3 Nos with synthetic enamel paint of appropriate colour in alternate layer upto height of 1.5 m above plinth block. (f) Painting of coping shall be cement base paint complete all as directed. (g) Embeded portion shall be painted with two coat of black bituminous paint complete all as directed. Note:- (i) This item consists of provision of steel pole and work mentioned in para (a) to (g) only. All other connected work, shall be measured and paid separately.
Supply and erecting Steel tubular swaged pole complete with cast iron base plate , finial taper plug , bolts , nuts & screws as specified type 410 SP-31, 9.00 mtr long, complete all as specified and shown on drawings including the followings:- (a) Excavation in post holes in any types of soil, returning filling, well ramming and disposal of surplus soil to a distance not exceeding 50 mtr from the starting points. (b) PCC (1:3:6) type C-2 using 40 mm graded stone aggregate as in foundation including form work. (c) PCC (1:2:4) type B-1 using 20 mm graded stone aggregate as in coping including form work. (d) PCC (1:4:8) type D-2 using 40 mm graded stone aggregate as in base. (e) Painting of poles externally with one coat of black bituminous paint (upto planting depth) and above plinth block concrete collar with two coats of aluminium paint over one coat of red oxide primer including preparation of surface including painting of 30 cm wide bands 3 Nos with synthetic enamel paint of appropriate colour in alternate layer upto height of 1.5 m above plinth block. (f) Painting of coping shall be cement base paint complete all as directed. (g) Embeded portion shall be painted with two coat of black bituminous paint complete all as directed. Note:- (i) This item consists of provision of steel pole and work mentioned in para (a) to (g) only. All other connected work, shall be measured and paid separately.
Supply and fix LED street 70 W IP 66 230 V AC outdoor type are aerodynamically designed with high pressure die cast alluminum housing and heat resistant complete with driver incl bracket of 32 mm dia light grade GI tubing 1.2 m long bend to shape with suitable size nut bolt & washer etc including making cable connection with 3 core PVC insulated copper conductor cable of 1.5 sqmm complete all as specified and directed.
M & L for DK Thermoplastic cable junction boxes IP 65 with metric knockouts for cable entry, weather proof for outdoor installation and including glands and with 4 terminals for terminating one incoming and outgoing UG cable of size 10/16 sqmm 3.5/4 core and fixed to the PSC/Steel Poles by means of suitable size of clamps with nut and bolts and incl provn for fixing 01 nos of single pole MCBs 6-32 amps,10KA inside the box and all as spcd and directed.
Supply and fixing sheet metal enclosure factory made with synthetic enamel painting complete and fixing to suitable plinth protection for PCC, angle iron etc with Astronomical time switches 415 Volts three phase of 32 Amp rating with contractor fitted inside steel enclosure complete panel including locking arrangement complete all as specified and directed.
Earthing complete with GI earth plate electrode 600 x 600 x 6 mm thick burried directly in ground (earth pit not less than 2.25 m deep below GL) with top edge of the plate not less than 1.5 m below the normal ground level connected with GI strip 32x6 mm thick by means of bolts, nuts, check nuts and washers of galvanised iron or steel including necessary excavation & earth work in any type of soil, removing surplus soil to a distance not exc 50 m, with and including PCC chamber in PCC (1:2:4), type B-1 using 20 mm graded stone aggregate, mild steel frame made out of angle iron of size 40 mm x 40 mm x 3 mm thick duly painted with two coats of synthetic enamel paint over one coat of red oxide zinc chrome primer hinged with and including 6 mm thick CI cover with handle, watering arrangement with funnel internally secured with wire mesh with 20mm dia medium grade pipe for watering, 40 mm dia light grade GI pipe for lead protection in and including alternate layer of charcoal dust and common salt complete all as shown in electrical plate No. 3 connected to earthing test point all as specified and indicated including testing on completion as directed. Note :- If the desired earth resistance is not found, earthing shall be redone by the contractor at no extra cost to the department.
Supply, installation commissioning and testing a main LT panel, out door type cubical panel board front and back opening both (Main Panel) an ISO: 9001 factory assembled made out door pedestal type feeder pillar box wheather and vermin proof fabricated of 3.15 mm CRCA MS sheet of Suitable size,3 phase 4 wire 415 Volt ac 50 Hz complete duly painted with powder coating complete with locking arrangement, earthing terminals with suitable rating aluminium strips for incoming/outgoing MCCB's including and mounting measuring instrument such as Volt meter, Ammeter,CT's, Phase indicator lamps including incoming and outgoing cables connections with suitable cable glands, lugs including grouting of feeder pillar box 60 cm above ground level by providing 90 cm long angle iron size 50x50x6mm welded on all four corner embedded in PCC (1:2:4) using 20mm graded upto 30cm complete all as specified and directed by the Engg-in-charge comprising of the following:-
Aluminium bus bars rating with 600 Amps high conductivity aluminium all capacity proper insulated of 1 ½ times of the incoming capacity with provision of extension and mounting on porcelain support
MCCB four pole 400 Amps, 35 KA , 415 volts, Thermal magnetic adjustable type 50Hz = 01 Nos ( Incoming )
MCCB four pole 250 Amps, 35 KA , 415 volts, Thermal magnetic adjustable type 50Hz = 05 No (4 No Outgoing for LT Panel & 01 No spare)
RYB indicating lamp, LED type 01 sets.
Internal wiring with suitable size of PVC insulated stranded copper conductor duly crimped with copper lugs ferruled.
Drawing shall be approved by GE before placing the order.
Aluminium bus bars rating with 400 Amps high conductivity aluminium all capacity proper insulated of 1 ½ times of the incoming capacity with provision of extension and mounting on porcelain support
MCCB four pole 250 Amps, 35 KA , 415 volts, Thermal magnetic adjustable type 50Hz = 01 Nos ( Incoming )
MCB four pole 63 Amps, 25 KA , 415 volts, Thermal magnetic adjustable type :- 04 No (outgoing) (3 No Outgoing building & 01 No spare)
RYB indicating lamp, LED type 01 sets.
Internal wiring with suitable size of PVC insulated stranded copper conductor duly crimped with copper lugs ferruled.
Drawing shall be approved by GE before placing the order.
Shifting of existing LT/HT pole/Over head LT Line from prop site to near suitable site including necessary PCC, ACSR conductor, excavation, RFR etc at required at site complete all as specifed and directed.
PAHELWAN TRADERS (BID ID -3153821)
Rahul Construction India Pvt Ltd (BID ID -3149620)
MD BUILDER (BID ID -3150089)
BD AGARWAL BUILDTECH INDIA PRIVATE LIMITED (BID ID -3153791)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
BOQ.xls
BOQ • 2.10 MB
Tenderdocument.rar
Tender Documents • 30.05 MB
Tenderdocument.pdf
Tender Documents • 2.52 MB
Download all tender documents and submit your bid