| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.8 LAccepted-AOC | L1 | Accepted-AOC DUE TO BEING L1 AND REASONABLE | |
| 2 | L2₹17.5 L+₹1.2 L (7.63%)Rejected-Finance | L2 | Rejected-Finance DUE TO NOT BEING L1 AND REASONABLE | |
| 3 | Rejected-Technical | - | Rejected-Technical ONE TIME VERIFICATION COPY IS NOT UPLAODED | |
| 4 | Rejected-Technical | - | Rejected-Technical ONE TIME VERIFICATION COPY AND ELNISTMENT LETTER NOT UPLOADED, RENEWAL COPY NOT UPLOADED |
Tender Value
Refer Docs
EMD Value
₹30,000
Closing Date
29 Feb 2024, 6:00 pmClosed
GE SOUTH AKHNOOR
GE SOUTH AKHNOOR
REPAIR AND MAINT OF AIR CONDITIONERS, WATER COOLERS AND COOLING APPLIANCES INCLUDING CONNECTED ITEMS AND REPAIR/REPLECEMENT OF INTERNAL WIRING LIGHT FITTINGS, REPAIR TO FAN FOR VARIOUS UNITS WITHIN AOR OF AGE E/M AT UNDER GE (S) AKHNOOR
2023_MES_632564_2
GES/AKH-49/2023-24
Open Tender
Civil Works
Item Rate
180 days
RAKMUTHI AND PALANWALA
MES EN-LISTED CONTRACTOR WITH CLASS E AND ABOVE WITH CATEGORY b(i)
9 documents required · 9 mandatory
₹500
GE SOUTH AKHNOOR
₹30,000
18 Apr 2024
8 Feb 2024
8 Mar 2024
8 Feb 2024
29 Feb 2024
15 Feb 2024
Amount
S&F in replacement of PVC insulated FRLS flexible cable with PVC insulated, sheathed, multi-stranded copper conductor 1100 volts grade, size 1.50 Sqmm, 3.0-core for connection, complete all as specified and as directed by Engineer-In-charge.
Disconnecting all electric connections and taking down of air conditioner of any capacity, split type, installed at the site or mounting at any height and transport to MES store yard/ workshop for servicing, cleaning/ removing the dust internally and externally, replacement of defective spare parts, as required including washing/ cleaning the outer surfaces, evaporator, condensor, air filters, ground chassis including making dry after washing, lubrication to rotatory parts, testing after repairs including making necessary connection to the power point (if required), complete all as specified and as directed by Engineer-In-Charge. Note: (i) New spare parts/ items required in replacement of old defective spare parts/ items shall be measured and paid separately under respective items. (ii) Cost of transportation from site to workshop for repair and workshop to site after repair, labour required for repairs/ replacement of spare parts being repair/ replaced, shall be deemed included in quoted rate.
Description all as per serial item No- 2.00 here-in-before but for air conditioner of any capacity, window type.
Supply only following new spare parts required to replacement for repairs of air conditioner (capacity as mentioned) :- (a) Motor for condensor of air conditioner, capacity 1.50 ton, window type, complete all as specified and as directed by Engineer-In-Charge.
(b) Condensing coil for air conditioner of 1.50 Ton capacity, complete all as specified and as directed by Engineer-In-Charge.
(c) Thermostat switch for air conditioner, capacity 1.50/ 2.0 ton, window type, complete all as specified and as directed by Engineer-In-Charge.
(d) Starting relay for air conditioner, capacity 1.50 Ton, window type, complete all as specified and as directed by Engineer-In-Charge.
(e) Over load protection relay, air conditioner, capacity 1.50 Ton, window type, complete all as specified and as directed by Engineer-In-Charge.
(f) Wiring kit for air conditioner, window type, capacity 1.50 Ton and as per existing specifications, including internal wiring, complete all as specified and as directed by Engineer-In-Charge.
(g) Front grill for air conditioner of 1.50 Ton capacity as per existing specifications, complete all as specified and as directed by Engineer-In-Charge.
(h) Air filter for air conditioner mettalic type), capacity 1.50 ton, window type, complete all as specified and as directed by Engineer-In-Charge.
(j) Gas/ refrigerant filter for air conditioner mettalic type), capacity 1.50 ton, window type, complete all as specified and as directed by Engineer-In-Charge.
(k) Cooling coil for air conditioner of 1.50 Ton capacity, complete all as specified and as directed by Engineer-In-Charge.
(l) Condensor fan blade for air conditioner of 1.50 Ton capacity, complete all as specified and as directed by Engineer-In-Charge.
(m) Operating knob for air conditioner of 1.50 Ton capacity, complete all as specified and as directed by Engineer-In-Charge.
(n) Fan for blower motor of air conditioner of 1.50 Ton capacity, complete all as specified and as directed by Engineer-In-Charge.
(o) Hermetic sealed unit (compressor) suitable for window type, uncut, for air conditioner of 1.50 Ton capacity, complete all as specified and as directed by Engineer-In-Charge.
(o) Hermetic sealed unit (compressor) suitable for window type, uncut, for air conditioner of 2.0 Ton capacity, complete all as specified and as directed by Engineer-In-Charge.
(p) Hermetic sealed unit (compressor) suitable for split type, uncut, for air conditioner of 1.50 Ton capacity, complete all as specified and as directed by Engineer-In-Charge.
(r) Printed Circuit Board for air conditioner, split type, capacity 1.50 Ton and as per existing specifications, including internal wiring, complete all as specified and as directed by Engineer-In-Charge.
(s) Blower motor for air conditioner, capacity 2.0 ton, split type, complete all as specified and as directed by Engineer-In-Charge.
(t) Copper tubes, size ¼ inches with insulation rubber, suitable for air conditioner of any capacity, split type, and as per existing specifications, fixing in repairs at any levels including clamps and screws, complete all as specified and as directed by Engineer-In-Charge.
(u) Copper tubes, size ½ inches with insulation rubber, suitable for air conditioner of any capacity, split type, and as per existing specifications, fixing in repairs at any levels including clamps and screws, complete all as specified and as directed by Engineer-In-Charge.
(v) Copper tubes, size 3/8 inches with insulation rubber, suitable for air conditioner of any capacity, split type, and as per existing specifications, fixing in repairs at any levels including clamps and screws, complete all as specified and as directed by Engineer-In-Charge.
(w) Copper tubes, size 5/8 inches with insulation rubber, suitable for air conditioner of any capacity, split type, and as per existing specifications, fixing in repairs at any levels including clamps and screws, complete all as specified and as directed by Engineer-In-Charge.
Replacement of old/ damaged base tray with new base tray of mild steel 1.60mm thick, duly painted with powder coated paint, suitable for air conditioner, capacity 1.50 Ton, by removing and re-fixing compressor, condensor coil, copper tube, complete all as specified and as directed by Engineer-In-Charge.
Recharging/ replacement/ filling of refrigerant (R-134a), suitable for air conditioner of any capacity and any specifications including testing and repairing against any leakage by welding, soldering, complete all as specified and as directed by Engineer-In-Charge.
Disconnecting all electric connections and transporting water coolers of any type and of any capacity, to MES store yard/ workshop for repairing and servicing, by cleaning/ washing the water storage tank, compressor and outer body, tightening the hinges/ screws and replacement of defective spare parts including testing after repairs and making necessary connection to the power points, complete all as specified and as directed by Engineer-In-Charge. Note: (i) New spare parts/ items required in replacement of old defective spare parts/ items shall be measured and paid separately under respective items. (ii) Cost of transportation from site to workshop for repair and workshop to site after repair, repair/ replacement and minor spare parts required of water coolers, shall be deemed included in quoted rate.
Supply only following new spare parts required to replacement for repairs of water coolers (capacity as mentioned) :- (a) Hermetic sealed unit, for water cooler capacity 40/80 liters, complete all as specified and as directed by Engineer-In-Charge.
(b) Hermetic sealed unit, for water cooler capacity 60/120 liters, complete all as specified and as directed by Engineer-In-Charge.
(c) Hermetic sealed unit, for water cooler capacity 150/180 liters, complete all as specified and as directed by Engineer-In-Charge.
(d) Condensor fan motor of 1/35 HP for water cooler of any capacity, complete all as specified and as directed by Engineer-In-Charge.
(e) Automatic thermostat suitable for water cooler any descriptions and of any capacity, complete all as specified and as directed by Engineer-In-Charge.
(f) Condensor fan blade for water cooler, capacity 40/80, 60/120 and 150/150 liters, complete all as specified and as directed by Engineer-In-Charge.
(g) Condensor coil for water cooler, capacity 40/80, 60/120 and 150/150 liters, complete all as specified and as directed by Engineer-In-Charge.
(h) Strainer (Micro filter) for ¼ gas (refrigerant) for condensor coil for water cooler, capacity 40/80, 60/120 and 150/150 liters, complete all as specified and as directed by Engineer-In-Charge.
(j) Evaporator coil for water cooler, capacity 40/80, 60/120 and 150/150 liters, complete all as specified and as directed by Engineer-In-Charge.
Recharging/ replacement/ filling of refrigerant (R-134a), suitable for water cooler any descriptions, capacity 40/80 Litres including testing and repairing against any leakage by welding, soldering, complete all as specified and as directed.
Recharging/ replacement/ filling of refrigerant (R-134a), suitable for water cooler any descriptions, capacity 60/120 Litres including testing and repairing against any leakage by welding, soldering, complete all as specified and as directed.
Recharging/ replacement/ filling of refrigerant (R-134a), suitable for water cooler any descriptions, capacity 150/150 & 180/180 Litres including testing and repairing against any leakage by welding, soldering, complete all as specified and as directed.
S&F in replacement of old unserviceable push button bib tap with new push button bib tap, long shank, cast copper alloy, chromium plated, fancy type, screwed down, screwed for iron pipe or for brass ferrule and fixed for 15mm bore pipe, fixing in repairs, complete all as specified and as directed by Engineer-In-Charge.
Spray painting of water cooler capacity 40/80 Litres with two coats of synthetic enamel paint of approved colour by spraying machine including filling cavities with filler, after cleaning all dusts and removing of dent from surfaces including writing of MES Nos. with synthetic enamel paint of black colour on lateral side of water cooler, complete all as specified and as directed by Engineer-In-Charge.
Spray painting of water cooler capacity 60/120 Litres with two coats of synthetic enamel paint of approved colour by spraying machine including filling cavities with filler, after cleaning all dusts and removing of dent from surfaces including writing of MES Nos. with synthetic enamel paint of black colour on lateral side of water cooler, complete all as specified and as directed by Engineer-In-Charge.
Spray painting of water cooler capacity 150/150 & 180/180 Litres with two coats of synthetic enamel paint of approved colour by spraying machine including filling cavities with filler, after cleaning all dusts and removing of dent from surfaces including writing of MES Nos. with synthetic enamel paint of black colour on lateral side of water cooler, complete all as specified and as directed by Engineer-In-Charge.
Disconnecting all electric connections and transporting refrigerator/deep Freezer of any capacity and any type, to MES store yard/ workshop for repairing and servicing, by cleaning/ washing the internal surfaces and racks, compressor and outer body and lubrication of movable parts, tightening the hinges and replacement of defective spare parts including testing after repairs and making necessary connection to the power points, complete all as specified and as directed by Engineer-In-Charge. Note: (i) New spare parts/ items required in replacement of old defective spare parts/ items shall be measured and paid separately under respective items. (ii) Cost of transportation from site to workshop for repair and workshop to site after repair, repair/ replacement and spare parts such as lubricating oil/ grease of refrigerator required being repair/ replaced, shall be deemed included in quoted rate.
Supply only following new spare parts required to replacement for repairs of refrigerator (capacity as mentioned) :- (a) Thermostat with auto defrost button for refrigerator of any descriptions, capacity 165 to 340 litres, complete all as specified and as directed by Engineer-In-Charge.
(b) Hermetic sealed unit uncut, capacity 1/8 HP, suitable for refrigerator of 165 to 210 liters capacity, complete all as specified and as directed by Engineer-In-Charge.
(c) Hermetic sealed unit uncut, capacity 1/6 HP, suitable for refrigerator of 210 to 285 liters capacity, complete all as specified and as directed by Engineer-In-Charge.
(d) Hermetic sealed unit uncut, capacity 1/6 HP, suitable for refrigerator of 300 to 340 liters capacity, complete all as specified and as directed by Engineer-In-Charge.
(e) Hermetic sealed unit, capacity 1/6 HP, suitable for deep freezer of 300 to 405 liters capacity, complete all as specified and as directed by Engineer-In-Charge.
(f) De-frost timer TMDE706 SC cycle time 6H35M, 60 Hz/ 7H54M, 50 Hz, single phase, 220- 240 Volts, suitable for deep freezers, complete all as specified and as directed by Engineer-In-Charge.
(g) Bimotel component of 4/3 wire for freezer/ refrigerator, capacity 285 to 340 liters, complete all as specified and as directed by Engineer-In-Charge.
(h) Relay, PTC of any type, suitable for refrigerator of 165 to 310 liters capacity, complete all as specified and as directed by Engineer-In-Charge.
(j) Refrigerator door seal of rubber gasket including proper insulation, for refrigerator of 165 to 280 liters capacity, complete all as specified and as directed by Engineer-In-Charge.
(k) Refrigerator door seal of rubber gasket including proper insulation and magnetic system, for refrigerator of 280 to 340 liters capacity, complete all as specified and as directed by Engineer-In-Charge.
(l) Lamp suiatble for refrigerator, pin/ screw type, for refrigerator of any capacity, complete all as specified and as directed by Engineer-In-Charge.
(m) Evaporator coil for refrigerator, capacity 165 to 180 liters, complete all as specified and as directed by Engineer-In-Charge.
(n) Evaporator coil for refrigerator, capacity 180 to 340 liters, complete all as specified and as directed by Engineer-In-Charge.
(o) Drain/ Ice tray suitable for refrigerator, capacity 165 to 280 liters, complete all as specified and as directed by Engineer-In-Charge.
(p) Drain/ Ice tray suitable for refrigerator, capacity 280 to 340 liters, complete all as specified and as directed by Engineer-In-Charge.
(q) Wiring kit for refrigerator, capacity 280 to 340 liters and as per existing specifications, including internal wiring, complete all as specified and as directed by Engineer-In-Charge.
Supply only Printed Circuit Board, three phase, suitable for deep freezer, any type, and as per existing specifications, complete all as specified and as directed by Engineer-In-Charge.
Supply only Condensor fan motor of 1/8 HP for Deep freezer, capacity 250 to 350 liters, complete all as specified and as directed by Engineer-In-Charge.
Replacement of old unserviceable/ damaged PVC staging/ plastic stand with new PVC staging stool/ plastic stand of different sizes, for refrigerator of 165 to 340 liters capacity, complete all as specified and as directed by Engineer-In-Charge.
Recharging/ replacement/ filling of refrigerant (R-134a), suitable for refrigerators/ deep freezers, any capacity including testing and repairing against any leakage by welding, soldering, complete all as specified and as directed.
Sheet metal enclosures with socket plug top and MCB suitable for single pole and neutral including a two pin and earth plug and socket complete with one single pole MCB, single pole, 40 Amps, 240 Volts, complete all as specified and as directed.
Disconnecting all electric connections from mains and transporting voltage stabilizer of any type and 1.0 to 5.0 KVA capacity, to MES store yard/ workshop for repairing/ servicing, by cleaning the outer body and replacement of defective spare parts including testing after repairs and making necessary connection with power points, complete all as specified and as directed by Engineer-In-Charge. Note: (i) New spare parts/ items required to replaced shall be measured and paid separately under respective items. (ii) Cost of transportation from site to workshop for repair and workshop to site after repair, repair/ replacement and minor spare parts required being replaced of voltage stabilizer, shall be deemed included in quoted rate.
Supply only following new spare parts required to replacement for repairs of voltage stabilizer (capacity as mentioned) :- (a) Voltmeter, rating 0-300 Volts, analog type, round shap, 2.50 inches dia, complete all as specified and as directed by Engineer-In-Charge.
(b) Power relay, 24 Volts, 260 Ohms, 30 Amps (set of three) suitable for voltage stabilizer, complete all as specified and as directed by Engineer-In-Charge.
(c) Power relay, 18 Volts, 500 Ohms, 30 Amps (set of three) suitable for voltage stabilizer, complete all as specified and as directed by Engineer-In-Charge.
(d) Bakelite terminal strip, (bakelite connector), 4-way, suitable for voltage stabilizer capacity 1.0 KVA to 5.0 KVA, complete all as specified and as directed by Engineer-In-Charge.
(e) Printed Circuit Board with 15 Volts IC, with internal wiring, suitable for voltage stabilizer capacity 1.0 KVA to 2.0 KVA, complete all as specified and as directed by Engineer-In-Charge.
(f) Printed Circuit Board with 24 Volts IC, with internal wiring, suitable for voltage stabilizer capacity 3.0 KVA to 5.0 KVA, complete all as specified and as directed by Engineer-In-Charge.
(g) Trigger transformer (control step down transformer), 24 Volts, 260 Ohms, suitable for voltage stabilizer, complete all as specified and as directed by Engineer-In-Charge.
(h) Trigger transformer (control step down transformer), 18 Volts, 260 Ohms, suitable for voltage stabilizer, complete all as specified and as directed by Engineer-In-Charge.
Rewinding of main transformer of voltage stabilizer capacity 1.0 KVA, single phase, with super enameled copper winding wire of existing insulation, gauge and specifications, complete all as specified and as directed by Engineer-In-Charge Note: Rewinding of transformer shall have same number of turns of winding wire and with matching to manufacturer design.
Rewinding of main transformer of voltage stabilizer capacity 2.0 KVA, single phase, with super enameled copper winding wire of existing insulation, gauge and specifications, complete all as specified and as directed by Engineer-In-Charge Note: Rewinding of transformer shall have same number of turns of winding wire and with matching to manufacturer design.
Rewinding of main transformer of voltage stabilizer capacity 4.0 KVA, single phase, with super enameled copper winding wire of existing insulation, gauge and specifications, complete all as specified and as directed by Engineer-In-Charge Note: Rewinding of transformer shall have same number of turns of winding wire and with matching to manufacturer design.
Rewinding of main transformer of voltage stabilizer capacity 5.0 KVA, single phase, with super enameled copper winding wire of existing insulation, gauge and specifications, complete all as specified and as directed by Engineer-In-Charge Note: Rewinding of transformer shall have same number of turns of winding wire and with matching to manufacturer design.
Taking down existing desert cooler of any capacity, mounting in any locations and transporting to MES store yard/ workshop for carrying out necessary repairs, servicing, oiling/ lubricating, cleaning the water tank, motor, blades and testing, return the same after carrying out necessary repair work installation at site or other location, including repairs of defective cable connections and making connections of indicating lamps, PVC water pipes and elbow etc, complete all as specified and as directed by Engineer-In-Charge. Note: (i) Spare parts shall be measured and paid separately under respective items of BOQ but cost of transportation to workshop and back to site, repairs shall be deemed included in quoted rate. (ii) Cost of minor spare parts such as PVC elbows, flexible pipes, lubricants, rubber pads and wire mesh shall be deemed included in quoted rate.
Supply only following new spare parts required to replacement for repairs of desert cooler (capacity as mentioned) :- (a) Fan motor, AC operated, single phase, three wires, capacity 1/7 HP, 240 volts suitable for desert cooler and making necessary electric connection and fixing mild steel arms, complete all as specified and as directed by Engineer-In-Charge.
(b) Fan motor, AC operated, single phase, three wires, capacity 1/6 HP, 240 volts suitable for desert cooler and making necessary electric connection and fixing mild steel arms, complete all as specified and as directed by Engineer-In-Charge.
(d) Submersible water pump (tullu pump), AC operated, single phase, capacity 1/20 HP, 240 volts suitable for desert cooler and making necessary connection to power supply including flexible PVC tubing of required size, complete all as specified and as directed by Engineer-In-Charge.
(e) Wooden wool/ grass pads for three sides including binding with GI wire tightly, for desert cooler of any specifications, complete all as specified and as directed by Engineer-In-Charge.
(f) Fan blade (Set of three), mild steel, existing size, with fixing screws with motor, suitable for dessert cooler, complete all as specified and as directed by Engineer-In-Charge.
(g) Mild steel wire mesh, made with 2.0mm dia gi wire powder coated paint, suitable for fixing wood wool pads, for desert cooler of any descriptions, complete all as specified and as directed by Engineer-In-Charge.
(h) Mild steel side, back grill including louvers fins, powder coated paint, suitable for fixing wood wool pads, for desert cooler of any descriptions, complete all as specified and as directed by Engineer-In-Charge.
(j) Supply only High density polythene pipe 15 mm dia complete all specified and directed
(k) Supply only Three way water distributor, heavy duty, PVC, including necessary nuts and bolts complete and taking out old distributor complete all specified and directed
Dismanting and taking out Old, Unservicable fan motor from the desert cooler and Rewinding with super enameled copper winding wire of suitable size, varnishing etc including replacement of bushes, assembling testing and refixing at the existing site complete all as specified and directed
M& L for fabrication of desert cooler stand made out of MS angle iron 40x40x6mm thick all as per existing size suitable at site incl painting ith two coats of synthetic enameld paint over a coat of red oxide primer coat .
Re-wiring of desert cooler with suitable size of copper conductor PVC insulated cable and providing main lead three metre long of 3 core PVC insulated copper conductor of size 23/ .0076 complete all specified and directed.
Supply and fixing in replacement Complete steel body of desert cooler of capacity 3000 cfm duly painted with two coats of synthetic enamel hammer tone paint over one coat of red oxide primer . The body of desert cooler shall be fabricated as under :- ( a ) The top and bottom made out of 1.25 mm thick GI sheet. ( b ) side panels (set of three) made out 1.00 mm thick GI sheet. ( c ) Front grill of suitable size and of approved quality.
S&F in replacement of old unserviceable ball valves with new ball valve, PVC, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed for 15mm bore pipe, complete all as specified and as directed by Engineer-In-Charge.
Replacement of old unserviceable/ damaged PVC connections with new PVC connections 15mm size, length 600mm with PTMT nuts at both ends, for inlet water supply, complete all as specified and directed by Engineer-In-Charge.
S&F in replacement of old unserviceable/ damaged capacitor with new capacitor, capacity 4.0mfd, suitable for electric equipments, complete all as specified and as directed by Engineer-In-Charge.
S&F in replacement of old unserviceable/ damaged capacitor with new capacitor, capacity 10.0mfd, suitable for electric equipments, complete all as specified and as directed by Engineer-In-Charge.
S&F in replacement of old unserviceable/ damaged capacitor with new capacitor, 36mfd, suitable for electric equipments, complete all as specified and as directed by Engineer-In-Charge.
Replacement of old unserviceable/ damaged capacitor with new capacitor, 45mfd, suitable for electric equipments, complete all as specified and as directed by Engineer-In-Charge.
S&F in replacement of old unserviceable/ damaged starting capacitor with new starting capacitor, 40/ 60mfd, suitable for electric equipments, complete all as specified and as directed by Engineer-In-Charge.
S&F in replacement of old unserviceable/ damaged starting capacitor with new starting capacitor, 100/ 120mfd, suitable for electric equipments, complete all as specified and as directed by Engineer-In-Charge.
Preparation of old painted surfaces of desert cooler metallic body by scrapping old paint with emery/ sand paper and spray painting with one coat of red oxide on internal surfaces and one coat of synthetic enamel paint on external surfaces in colour as approved and writing MES No. on body of dessert cooler, complete all as specified and as directed by Engineer-In-Charge.
Sub main wiring for circuits/ submain wiring alongwith earth wire with two run of 6.0 Sqmm of fire resistance, PVC insulated copper conductor, single core cable, multi-stranded, FRLS, ISI marked, 1100 Volts grade and one run of 6.0 Sqmm, FRLS, PVC insulated copper conductor, single core cable, multi stranded, ISI marked, 1100 Volts grade as earth wire connected to earth terminal, drawn in and including non metallic medium grade rigid PVC conduit, fire resistance, ISI marked, 25mm dia including all accessories, concealed by chasing/ cutting grooves in the surface of walls/ floors/ ceilings and making good the disturbed surface matching to existing descriptions/ specifications incl taking down old sub main, complete all as specified and as directed by Engineer-In-Charge. Note: Two runs of 10.0 sqmm copper wires and one run of 6.0 Sqmm copper wires including PVC conduit shall be measured as one unit.
Sub main wiring for circuits/ submain wiring alongwith earth wire with two run of 4.0 Sqmm of fire resistance, PVC insulated copper conductor, single core cable, multi-stranded, FRLS, ISI marked, 1100 Volts grade and one run of 4.0 Sqmm, FRLS, PVC insulated copper conductor, single core cable, multi stranded, ISI marked, 1100 Volts grade as earth wire connected to earth terminal, drawn in and including non metallic medium grade rigid PVC conduit, fire resistance, ISI marked, 25mm dia including all accessories, concealed by chasing/ cutting grooves in the surface of walls/ floors/ ceilings and making good the disturbed surface matching to existing descriptions/ specifications taking down old sub main, complete all as specified and as directed by Engineer-In-Charge. Note: Three runs of 4.0 Sqmm copper wires including PVC conduit shall be measured as one unit.
S&F in replacement of old unserviceable/ damaged MCCB with new MCCB, three pole, 415 Volts, adjustable thermal and fixed magnetic setting, 100 Amps with breaking capacity 16 KA, having indicating lamp, Ics=100% Icu and as per IEC 60947-2, complete all as specified and as directed by Engineer-In-Charge. Make: Schneider cat part No- LV426157 or equivalent in in L&T/ Legrand/ ABB/ Merlin Gerin/ Siemens.
S&F in replacement of Sheet metal enclosures for Single Pole and Neutral distribution boxes with double door glazed for incorporating MCBs, IP-43, 8-way with 200 amps rated busbar, 240 volts, as per IS-8623, complete all as specified and as directed by Engineer-In-Charge.
S&F in replacement of old unserviceable MCB with new MCB, Single pole and Neutral, 40 Amps, 240 Volts, having breaking capacity of 10 KA, ‘C’ series, conforming to IS/IEC: 60898, complete all as specified and as directed by Engineer-In-charge.
S&F in replacement of MCB, single pole, 6 to 32 Amps, 240 Volts, 50 Hz, including necessary incoming and out going electric connection with suitable size of copper lugs, complete all as specified and as directed by Engineer-In-Charge.
Supplying and fixing in replacement of 1100 Volts grade, heavy duty, multi-stranded cable, PVC insulated aluminium conductor, multi-stranded, cross sectional area 10.0 Sqmm, 2-core, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1.0 metre apart Including 4.0mm suspension wire, one twin core cable flat or circular, complete all as specified and as directed by Engineer-In-Charge.
Supplying and fixing in replacement of PVC insulated FRLS flexible cable with PVC insulated, sheathed, multi-stranded copper conductor 1100 volts grade, size 4.0 Sqmm, 3-core for connection, complete all as specified and as directed by Engineer-In-charge.
Supplying and fixing in replacement of PVC insulated FRLS flexible cable with PVC insulated, sheathed, multi-stranded copper conductor 1100 volts grade, size 2.50 Sqmm, 3-core for connection, complete all as specified and as directed by Engineer-In-charge.
Supplying and fixing in replacement of Sheet metal enclosures with socket plug top and MCB suitable for single pole and neutral including a two pin and earth plug and socket complete with one single pole MCB, single pole, 20 Amps, 240 Volts, complete all as specified and as directed by Engineer-In-Charge.
Supplying and fixing in replacement of old unserviceable/ damaged plug top with new plug top, 15 Amps, 3-pin, 240 volts, complete all as specified and as directed by Engineer-In-Charge.
Supplying and fixing in replacement of old unserviceable/ damaged plug top with new plug top, 5 Amps, 3-pin, 240 volts, complete all as specified and as directed by Engineer-In-Charge.
Supplying and fixing in replacement of PVC insulated flat twin core aluminium stranded cable 1100 volts grade, size 4.0 Sqmm, complete all as specified and as directed by Engineer-In-charge.
Supplying and fixing in replacement of PVC insulated flat twin core aluminium stranded cable 1100 volts grade, size 6.0 Sqmm, complete all as specified and as directed by Engineer-In-charge.
Supplying and fixing in replacement of PVC insulated flat twin core aluminium stranded cable 1100 volts grade, size 10.0 Sqmm, complete all as specified and as directed by Engineer-In-charge.
Supplying and fixing in replacement of PVC insulated flat twin core aluminium stranded cable 1100 volts grade, size 16.0 Sqmm, complete all as specified and as directed by Engineer-In-charge.
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc., complete all as specified and as directed by Engineer-In-Charge.
Point wiring (in existing conduits) for one light/ fan/ bell point controlled by one switch with 1.50 Sqmm, PVC insulated, unsheathed, single core, multi-stranded, copper conductor cable, 1100 Volts, using colour coding, drawn in existing conduit of any type and any dia including making good the disturbed surface matching to existing descriptions/ specifications, with and including sunken type pressed steel/ welded mild steel terminal box 1.20mm thick coated with anti corrosive paint and with bakelite laminated sheet top cover 3.0mm thick and including FRLS PVC green insulated unsheathed 1.50 Sqmm copper earth continuity wire connected to earth dolly, complete all as specified and as directed by Engineer-In-Charge.
Description all as per serial item No- 121.00 here-in-before but for one 3-pin socket outlet 5-Amps on the independent board.
Description all as serial item No- 121.00 here-in-before but for one 3- pin, 5-Amps, socket outlet on same board.
Point wiring (in existing conduits) for 3-pin, 15 Amps, switch socket combination on independent board with 2.50 Sqmm, PVC insulated, unsheathed, single core, multi-stranded, copper conductor cable, FRLS, 1100 Volts, using colour coding, drawn in existing conduit of any type and any dia including making good the disturbed surface matching to existing descriptions/ specifications, with and including sunken type pressed steel/ welded mild steel terminal box 1.20mm thick coated with anti corrosive paint with bakelite laminated sheet top cover 3.0mm thick and including FRLS PVC green insulated unsheathed 2.50 Sqmm copper earth continuity wire connected to earth dolly, complete all as specified and as directed by Engineer-In-Charge.
Point wiring (concealed to surfaces) for one light/ fan/ bell point controlled by one switch with 1.50 Sqmm, PVC insulated, unsheathed, single core, multi-stranded, copper conductor cable, 1100 Volts, using colour coding, drawn in and including non metallic medium grade rigid PVC conduit, fire resistance, ISI marked, 20mm dia including all accessories concealed by chasing/ cutting grooves in the surface of walls/ floors/ ceilings and making good the disturbed surface matching to existing descriptions/ specifications, with and including sunken type pressed steel/ welded mild steel terminal box 1.20mm thick coated with anti corrosive paint and with bakelite laminated sheet top cover 3.0mm thick and including FRLS PVC green insulated unsheathed 1.50 Sqmm copper earth continuity wire connected to earth dolly, complete all as specified and as directed by Engineer-In-Charge.
Description all as serial item No- 125.00 here-in-before but for one 3- pin, 5-Amps, socket outlet on same board.
Description all as per serial item No- 125.00 here-in-before but for one 3-pin socket outlet 5-Amps on the independent board.
Point wiring (concealed to surfaces) for 3-pin, 15 Amps, switch socket combination on independent board with 2.50 Sqmm, PVC insulated, unsheathed, single core, multi-stranded, copper conductor cable, FRLS, 1100 Volts, using colour coding, drawn in and including non metallic medium grade rigid PVC conduit, fire resistance, ISI marked, 20mm dia including all accessories concealed by chasing/ cutting in the surface of walls/ floors/ ceilings and making good the disturbed surface matching to existing descriptions/ specifications, with and including sunken type pressed steel/ welded mild steel terminal box 1.20mm thick coated with anti corrosive paint with bakelite laminated sheet top cover 3.0mm thick and including FRLS PVC green insulated unsheathed 2.50 Sqmm copper earth continuity wire connected to earth dolly, complete all as specified and as directed by Engineer-In-Charge.
Switch piano, flush type, single pole, one way, 5 Amps, complete all as specified and as directed by Engineer-In-Charge.
Socket outlet, 5-pin, 5-Amps, flush type, complete all as specified and as directed by Engineer-In-Charge.
Switch socket combination, 2-in-1, 3-pin, 5-Amps, flush type, complete all as specified and as directed by Engineer-In-Charge.
Switch socket combination 2-in-1, 3-pin and 5 pin, 5 and 15 Amp flush type universal type, complete all as specified and as directed by Engineer-In-Charge.
Electronic dimmers, 450W, 250V flush type on the exiting phenolic laminated sheet etc. as reqd, complete all specified and as directed by Engineer-In-charge.
Ceiling rose, three phase/ PVC/ polycarbonate, isolated body, complete all as specified and as directed by Engineer-In-Charge.
Lamp holder, PVC Polycarbonate type with back plate suitable for batten fittings inlcuding retrofit LED lamp of 9 Watt, complete all as specified and as directed by Engineer-In-Charge.
S&F 4 feet highly engineered wall mounted LED 20W batten with polycarbonate housing & integrated electronic driver and basic all purpose surface .. The luminaire should have a color consistency SDCM < 5, CRI > 80 and CCT of 6500K. The luminaire shall be compliant with IP20 and IK02 classification. Luminaire shall be designed to emit at least 2000 nominal lumens and an outstanding solution efficacy of atleast 100 lumen/watt and maximum system wattage of 20 Watts. The electronic driver used shall have a power factor >0.95 and THD <20% with 4 KV internal surge protection. Manufacturer shall have inhouse lab approved by NABL or ministry of science of govt of India. LM 79 and LM80 reports need to be submitted from a NABL/UL accredited lab to verify above parameters and including suitable size and length of flexible copper wire and making the connection, complete all as specified and as directed by Engineer-In-Charge. Make : Crompton Model No Trimline Neu cat part CCS-103-20-40-SL-DP-NWH or Equivalent makes in Philips/Wipro/GE/C&S. Warranty certficate for 2 years to be provided by Employee of Organization of Terittory.
S & F Inverter LED Batten with opal diffuser, IP20, battery back-up & functioning as per product TDS, 20 Watt, complete with all accessories with twin core twisted flexible copper conductor cable with suitable size all as specified and directed. Havells cat part No- PRIDE PLUS INVERTER BATTEN LHEXACP7FN1W020 or Equivalent Makes in Crompton/Philips/Osram.
S&F in replacement of Recess LED 2x2 luminaire with CRCA housing suitable with fully diffused diffuser for general lighting in office areas. The luminaire should have a color consistency SDCM < 5, CRI > 80 and CCT of both 4000K / 6500K. The luminaire shall be compliant with IP20 and IK02 classification. Luminaire shall be designed to emit at least 3600 nominal lumens and an outstanding solution efficacy of atleast 100 lumen/watt and maximum system wattage of 36 Watts.The luminaire shall be designed so as to ensure lumen depreciation of up to 30% over 50k burning hours @ design ambient temp 45 deg C. The electronic driver used shall have a power factor >0.95 and THD <10% with 3 KV internal surge protection. Manufacturer shall have inhouse lab approved by NABL or ministry of science of govt of India. LM 79 and LM80 reports need to be submitted from a NABL/UL accredited lab to verify above parameters and including suitable size and length of flexible copper wire and making the connection, complete all as specified and as directed by Engineer-In-Charge. Make : Crompton cat part No- LCTRS-36-WW or Equivalent makes in Philips/Wipro/GE/C&S. Warranty certficate for 2 years to be provided by Employee of Organization of Terittory.
Sub main wiring in repair (concealed conduits to surfaces) for circuits/ sub main wiring alongwith earth wire with two run of 4.0 Sqmm of fire resistance, PVC insulated copper conductor, single core cable, multi-stranded, FRLS, ISI marked, 1100 Volts grade and one run of 2.50 Sqmm, FRLS, PVC insulated copper conductor, single core cable, multi stranded, ISI marked, 1100 Volts grade as earth wire connected to earth terminal, drawn in and including non metallic medium grade rigid PVC conduit, fire resistance, ISI marked, 25mm dia including all accessories concealed by chasing/ cutting grooves in the surface of walls/ floors/ ceilings and making good the disturbed surface matching to existing descriptions/ specifications, complete all as specified and as directed by Engineer-In-Charge.
Sub main wiring in repair (concealed conduits to surfaces) for circuits/ submain wiring alongwith earth wire with two run of 6.0 Sqmm of fire resistance, PVC insulated copper conductor, single core cable, multi-stranded, FRLS, ISI marked, 1100 Volts grade and one run of 4.0 Sqmm, FRLS, PVC insulated copper conductor, single core cable, multi stranded, ISI marked, 1100 Volts grade as earth wire connected to earth terminal, drawn in and including non metallic medium grade rigid PVC conduit, fire resistance, ISI marked, 25mm dia including all accessories concealed by chasing/ cutting grooves in the surface of walls/ floors/ ceilings and making good the disturbed surface matching to existing descriptions/ specifications, complete all as specified and as directed by Engineer-In-Charge.
Sheet metal enclosures in repair for Single Pole and Neutral distribution boxes with double door glazed for incorporating MCBs, IP-43, 8-way with 200 amps rated busbar, 240 volts, as per IS-8623, complete all as specified and as directed.
Sheet metal enclosures in repair for Single Pole and Neutral distribution boxes with double door glazed for incorporating MCBs, IP-43, 12-way with 200 amps rated busbar, 240 volts, as per IS-8623, complete all as specified and as directed.
MCB, Triple Pole and Neutral, 63 Amps, 240 volts, 50 Hz, 'C' curve including necessary incoming and outgoing electric connection with suitable size of copper lugs, complete all as specified and as directed by Engineer-In-Charge.
MCB, Single Pole and Neutral, 40 Amps, 240 volts, 50 Hz, 'C' curve including necessary incoming and outgoing electric connection with suitable size of copper lugs, complete all as specified and as directed by Engineer-In-Charge.
MCB, single pole, 6 to 32 Amps, 240 Volts, 50 Hz, including necessary incoming and outgoing electric connection with suitable size of copper lugs, complete all as specified and as directed by Engineer-In-Charge.
Supply and fixing in replacement, 1100 Volts grade, heavy duty, multi-stranded cable, PVC insulated aluminium conductor, multi-stranded, cross sectional area 10.0 Sqmm, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1.0 metre apart Including 4.0mm suspension wire, one twin core cable flat or circular, complete all as specified and as directed by Engineer-In-Charge.
M & L for disconnecting electric supply, taking down fan, celing cable ends, dismantling blades carefully after unscrewing nuts and bolts of ceiling fan of any make from existing position and bringing to AGE E/M store yard for repairs, overhauling, oiling, greasing and cleaning all dusts all as specified and as directed by EIC. complete all as specified and as directed by EIC. Note : Store like ball bearing, gun metal bush, capacitors and canopy required for repair/over hauling shall be measured and paid separately under relevant item of this schedule.
Dismantling of worn out/burnt out ceiling fans 1200 mm sweep and re-winding the ceiling fan with the same size of super enamelled copper wire , varnishing with approved quality insulating varnish complete including replacement of split/safety pins, locking nut, check nut , complete all as specified and directed by Engineer in charge
Description all as per serial item No 148.00 above but for Ceiling fans of 1400 mm sweep.
Supply and fixing in replacement of ball bearing suitable for ceiling fans of any make, type and size. Make: - SKF, NBC, and TATA
Supply and fixing in replacement of capacitors 4.0 MFD suitable for exhasut fans of any make, type and size. Make: - Usha, Universal, Tipcon, Epcos.
Supply and fixing in replacement of capacitors 2.5 MFD suitable for ceiling fans of any make, type and size. Make: - Usha, Universal, Tipcon, Epcos.
Supply and fixing in replacement of fan blade made of ms sheet duly powder coated of approved make and colour suitable for ceiling fan of 1200 mm sweep incl all accessories, complete all as specified and directed by Engr-in-Charge.
Taking down carefully existing exhaust fans of any make and sizes from wall , cleaning externally, opening for examination and overhauling complete by opening , cleaning of bearing ,stator ,rotor winding , providing new fresh clean proper grade lubricants oil/grease and re assembling after replacement of split/safety pins, MS nuts and bolts , including replacement of old existing flexible cord connected from ceiling rose to fan including re-writing MES/ SL No. with black synthetic enamel paint , refixing the same in position complete all as specified and directed by Engineer in charge. Note:-Store like ball bearing, gun metal bush and capacitors required for repair/overhauling shall be measured and paid separately under relevant item of this schedule complete all as specified and directed by Engr-in-Charge.
Dismantling of worn out/burnt out Exhaust fans 275 mm to 375 mm sweep and re-winding the exhaust fan with the same size of super enamelled copper wire , varnishing with approved quality insulating varnish complete including replacement of split/safety pins, rusted nut ,bolt and washer complete all as specified and directed by Engineer in charge.
Description all as per serial item No 155.00 above but for Exhaust fans of size above 375 mm but up to 450 mm sweep complet all as specified and directed by Engr-in-Charge.
Supply and fixing in replacement of ball bearing suitable for exhaust fans of size from 275 mm to 375 mm sweep. Make: - SKF, NBC, and TATA.
Supply and fixing in replacement of ball bearing suitable for exhaust fans of size above 375 mm to 475 mm sweep. Make: - SKF, NBC, and TATA.
Supply only Blade assembly of Exhaust fan with fixing hexagonal nut of size 300 to 450mm of existing make and colour of product, complete all as specified and as directed by Engineer-In-Charge.
Supply only iron Frame of exhaust fan 4 way with welded and painted, complete all as specified and as directed by Engineer-In-Charge.
Supply only Gun metal bush of exhaust fan of any sweep, complete all as specified and as directed by Engineer-In-Charge.
Supply only rubber reel with a pair of clamp, nuts, bolts, split pins etc suitable for ceiling fan down rods of any size and make as required , complete all as specified and as directed by Engineer-In-Charge.
Supply only PVC canopy suitable for ceiling fan of any size and make as required , complete all as specified and as directed by Engineer-In-Charge.
Supply only PVC insulated and sheathed flexible 3 core cable with copper conductor of size 0.5 sqmm , complete all as specified and as directed by Engineer-In-Charge.
Supply only down rod of ceiling fan made of GI pipe medium grade 15 mm bore of length upto 600 mm including cutting, threading, painting etc as required.
Disconnecting the inlet and outlet connections of the existing Geyser 25/50 Ltr, taking down carefully, cleaning/descaling the blocks both in GI pipes and water heater refixing the bolts by proper grouting in the wall and refixing the water heater in the same or in other places as directed.
Replacement of unserviceable heating element of geyser 2KW/1.5 KW of any pattern all as specified. Make: Dasspass/Recold/Bajaj.
Replacement of unserviceable thermostat of geyser 2KW/1.5 KW of any pattern all as specified. Make: Dasspass/Recold/Bajaj
Replacement of unserviceable PVC flexible pipe inlet 16mm outer dia and 450 mm long for hot/cold water heavy duty with brass nuts & bolts, complete all as specified and directed
Repairs to voltage stabilizer of any make, single phase with input voltage 135 - 190 V and out put voltage 200-240 volt, capacity 5 KVA by dismantling and taking out burnt main transformer and rewinding with super enamelled copper wire of suitable size including varnishing and insulation material etc.complete all as specified and directed
All as per item No-170.00 above but of capacity 03 KVA
All as per item No- 170.00 above but of capacity 01 to 02 KVA
Dismantling and servicing of cooling appliances including cleaning, painting, necessary test of leakage by nitrogen gas, brazing, compressed air wash and make the system functional complete all as specified for split type AC of any capacity.
Dismantling and servicing of cooling appliances including cleaning, painting, necessary test of leakage by nitrogen gas, brazing, compressed air wash and make the system functional complete all as specified for Window type AC of any capacity.
All as per item No 174.00 above but of Water Cooler of any capacity
All as per item No 174.00 above but for Refrigerator of any capacity
Disconnect the suction and discharge line to the unserviceable compressor, replace with the new compressor brought from the factory of the same make connect the refregerent lines systems flushing vacuumising of the entire system arrest all leakages including testing and commissioning for split AC 1.5 ton capacity
Disconnect the suction and discharge line to the unserviceable compressor, replace with the new compressor brought from the factory of the same make connect the refregerent lines systems flushing vacuumising of the entire system arrest all leakages including testing and commissioning for window AC 1.5 ton capacity
All as per item No-178.00 above but for Water Cooler above 60 ltrs upto 150 Ltrs capacity
All as per item No-178.00 above but for Water Cooler 40 to 80 Ltrs capacity
All as per item No-178.00 above but for Refrigerator 165 to 320 Ltrs capacity
Replacement of unserviceable thermostat of AC up to 1.5 Ton, complete all as specified and directed
All as per item No 182.00 above but for Water Cooler upto 150 Ltrs capacity
All as per item No 182.00 above but for Refrigerator up to 320 Ltrs capacity
Remove the unserviceable fan blade from the condenser cooling motor and replace with new fan blade of same size and type for Water Cooler any capacity, complete all as specified and directed
All as per item No 185.00 above but for Air conditioners up to 1.5 Ton.
Replacement of unserviceable float valve with new brass Float valve of water cooliers/ desert coolers complete 15 mm dia , complete all as specified and directed
Flushing & vacuumising the system and charging of necessary refrigerent at required quantity for Window AC cap 1.5 Ton, complete all as specified and directed
All as per item No-188.00 above but for Refrigerators of any capacity.
All as per item No-188.00 above but for Water coolers of any capacity.
All as per item No-188.00 above but for Water coolers of any capacity.
Fushing, vaccumising of the entire system and charging of necessasy refrigerent of required quantity for split AC 1.5 ton capacity
Remove the unserviceable fan motor from Split AC 1.5 Ton capacity removing the burnt out winding wire from slots, clean slots with emery paper and rewind the same with superior quality copper wire insulate properly and bringing back and fixing in position and testing and commissioning:-
Remove the unserviceable fan motor from window AC any capacity removing the burnt out winding wire from slots, clean slots with emery paper and rewind the same with superior quality copper wire insulate properly and bringing back and fixing in position and testing and commissioning:-
All as per item No 193.00 above but for Water Cooler upto 150 Ltrs capacity
Replacement of unserviceable air filter for window AC of any capacity, complete all as specified and directed
Remove the unserviceable fan blade from the condenser cooling motor and replace with new fan blade of same size and type for Split Air conditioners up to 1.5 Ton capacity, complete all as specified and directed
S&F in replacement of Earthing complete with galvanised steel earth plate electrode 60 cm x 60cmx6mm thick buried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) with top edge of plate not less than 1.5 meters below normal ground level. connecting to the GI wire 4 mm dia by means of bolls, nuts, check nuts and washers of galvanised iron and earth wire protected by provision of GI light grade pipe 15 mm bore including provision of concrete pit in PCC (1:2:4) type B-1 using 20mm graded stone aggregates with 40mm thick cover of RCC (1:2:4) reinforced with XPM weight not less than 4 Kg/Sqm) and frame of angle iron 25x25x6mm with lugs 02 Nos and handle of 6mm dia MS bar made to shape, GI medium grade 20mm bore pipe for watering , perforated at bottom. 1.75 metre long placed on top edge of earth plate. charcoal and common salt filling with fixing arrangement, funnel wire mesh and earth work in soft soil returning filling in and removal of surplus soil to a distance not exceeding 50 meters all as per electrical plate 3 of SSR-2009 Part-I and connecting to earth test point all as specified or indicated including testing on completion. NOTE :- (i) Item of earthing includes cost of 7.5 m long GI wire of size 4 mm dia with protection pipe of 15mm dia GI medium grade, any variation in length shall be adjusted through deviation order based on SSR rates reduced by (-20)%. (ii) On testing after completion of earthing if the desired earth resistance is not obtained earthing will be re-done by the contractor at his own risk and cost.
SPECIAL NOTE FOR APPLIANCES REPAIRS : The contractor will submit a copy of Memorandum of under standing from OEMs ( or authorized dealers) to the Engr-in-Charge for the respective E/M equipments before start of repair work. The details of OEMs are as under:- (a) AIR CONDITIONER (i) HITACHI (ii) BLUE STAR (iii) VOLTAS (iv) DAIKEN (b) FREEZER/DEEP FREEZER (i) LG (ii) SAMSUNG (iii) VOLTAS (iv) BLUE STAR (C) EXHAUST FANN & CEILING FAN (i) BAJAJ (ii) CROMPTON (iii) HAVELLS (iv) ORIENT (D) WATER HEATERS/GEYSER (i) BAJAJ (ii) HAVELLS (iii) RACOLD (E) WATER COOLER (i) VOLTAS (ii) BLUE STAR (iii) SHRI RAM (USHA)
Amount of Schedule of credit of for Rs 1,50,800.00 shall be deducted from quoted amount.
M/S CJ CONSTRUCTIONS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .