| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹10.0 LAdmitted-Fee/PreQual/Technical/Finance | L1 | Admitted-Fee/PreQual/Technical/Finance | ||
| 2 | L2₹11.5 L+₹1.5 L (15.2%)Admitted-Fee/PreQual/Technical/Finance | L2 | Admitted-Fee/PreQual/Technical/Finance | ||
| 3 | Not Admitted-Fee/PreQual/Technical/Finance | - | Not Admitted-Fee/PreQual/Technical/Finance Others-CDR not in the name of Bidding firm,Treasury chalan not in the name of bidding firm ,GST registered with different bidding firm same with GST-3B ,bank account linked with GSTIN either not linked or not authenticated | ||
| 4 | Not Admitted-Fee/PreQual/Technical/Finance | - | Not Admitted-Fee/PreQual/Technical/Finance Others-CDR already submitted for NIT 106,Treasury chalan either not submitted or provided with wrong details |
Tender Value
₹12.8 L
EMD Value
₹25,557
Closing Date
19 Aug 2026, 4:00 pmClosed
EXECUTIVE ENGINEER RNB ELECTRIC DIVISION KASHMIR
RNB ELECTRIC DIVISION KASHMIR ENGINEERING COMPLEX RAJ BAGH
Upgradation of FnV Market at Prichoo, Pulwama Phase II B.W.O Electric work
2026_PWDJK_319527_1
NIT No.107//2026-27 Dt/05/08/2026
Open Tender
Electrical Works
Percentage
Prichoo
Please refer Tender documents.
5 documents required · 5 mandatory
₹600
EXECUTIVE ENGINEER RNB ELECTRIC DIVISION KASHMIR
₹25,557
31 Aug 2026
5 Aug 2026
20 Aug 2026
5 Aug 2026
19 Aug 2026
5 Aug 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 2X 1.5 sq.mm FRLS PVC insulated copper conductor ( Havell/Polycab/ Apar/ paraflex/ Anchor/equivalent as directed by engineer incharge.) single core cable in surface / recessed (cutting the wall and making good the same in case of recessed conduit ) medium class PVC conduit/ duct( Anchor/ Polycab /Ravindra/equivalent make as directed by engineer incharge.), with modular switch ( Legrand Mylinc /SSK NV/schneider Zencelo /Crabtree athena make.), modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.The job also includes providing and laying of circuit wiring with 3x2.5 sqmm FRLS PVC insulated copper conductor ( Havell/Polycab/ Fenolex/Anchor/ eq. make.) single core cable in surface / recessed medium class PVC conduit. Sample to be approved by EIC | 150 | Point | 1,250 | ₹1,87,500 |
| 2 | Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor ( Havell/Polycab/ Apar/ paraflex/ Anchor/equivalent as directed by engineer incharge.) single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required. | 25 | Point | 649 | ₹16,225 |
| 3 | Wiring for light/ power plug with 2X4 sq. mm + 1X 4 sq. mm earth wire , FRLS PVC insulated copper conductor ( Havell/Polycab/ Apar/ paraflex/Anchor make ) single core cable in surface/recessed (cutting the wall and making good the same in case of recessed conduit ) medium class PVC conduit ( Anchor/ Polycab /Ravindra/equivalent make as directed by engineer incharge.) | 350 | Mtr | 285 | ₹99,750 |
| 4 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. Modular Switch & Socket:- ( Legrand Mylinc /SSK NV/schneider Zencelo /Crabtree athena/ eq. make.) Sample to be approved by EIC | 40 | Each | 450 | ₹18,000 |
| 5 | Wiring for 6- 10 amp power plug with 2X2.5 sq. mm FRLS PVC insulated copper conductor ( Havell/Polycab/ Apar/ paraflex/Anchor make) single core cable in surface/recessed (cutting the wall and making good the same in case of recessed conduit ) medium class PVC conduit ( Anchor/ Polycab /Ravindra/equivalent make as directed by engineer incharge.) alongwith 1 No. 2.5 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. | 850 | Mtr | 220 | ₹1,87,000 |
| 6 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings). Modular Switch & Socket:- ( Legrand Mylinc /SSK NV/schneider Zencelo /Crabtree athena/ eq. make.). Sample to be approved by EIC | 40 | No. | 550 | ₹22,000 |
| 7 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. Sample to be approved by EIC | 15 | No. | 401 | ₹6,015 |
| 8 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor ( Havell/Polycab/ paraflex/Anchor make/) equivalent as directed by engineer incharge.), single core cable in surface/ recessed (cutting the wall and making good the same in case of recessed conduit ) medium class PVC conduit as required. | - | - | - | - |
| 9 | (a) 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire | 150 | Mtr. | 195 | ₹29,250 |
| 10 | (d)2 X 6 sq. mm + 1 X 6 sq. mm earth wire | 250 | Mtr. | 350 | ₹87,500 |
stage.html
html • 0.02 MB
finance_1058777.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.50 MB
BOQ_1058777.xls
BOQ • 0.27 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .