Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Infra Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹49.9 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹54.0 L+₹3.9 L (7.71%)Rejected-Finance | L2 | Rejected-Finance Not being L1 | |
| 3 | L3₹55.5 L+₹5.4 L (10.8%)Rejected-Finance | L3 | Rejected-Finance Not being L1 | |
| 4 | L4₹55.9 L+₹5.8 L (11.6%)Rejected-Finance | L4 | Rejected-Finance Not being L1 | |
| 5 | Rejected-Technical AKULA STREET BHAPUR BAZAR BERHAMPUR DISTT GANJAM ODISHA 760001 | GANJAM | ODISHA | 760001 | - | Rejected-Technical Not enlisted in required category |
Tender Value
Refer Docs
EMD Value
₹94,000
Closing Date
29 Dec 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GARRISON ENGINEER I GOS
GARRISON ENGINEER I GOPALPUR MILITARY STATION PO GOLABANDHA DIST GANJAM ODISHA 761052
ADDN ALTN TO TOILET NEAR BLDG NO P 64 AND ALLIED WORKS FOR CENTRALISED CLASS ROOM UNDER GE I GOS
2023_MES_619110_3
8000/83/2023-24/0982/E8
Open Tender
Civil Works
Item Rate
180 days
GOS
As per Tender documents
6 documents required · 6 mandatory
₹500
GARRISON ENGINEER I GOS
₹94,000
Yes
16 Mar 2024
16 Dec 2023
30 Dec 2023
16 Dec 2023
29 Dec 2023
23 Dec 2023
Amount
Demolition of Cement Concrete (unreinforced) in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified & directed.
Taking down chowkhat or frames exc 1.50 Sqm and n exc 4 Sqm each with shutters (without taking off shutters from the frame) and removing to store complete all as specified and directed
Demolition of brick work or stone/boulder masonry built in cement mortar including all quoins, arches, pillars etc complete all as specified and directed.
S&F solid PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet re-inforced with MS square tube in opening as per specification and shown on drawing SSR Part-II 2020 complete all as specified and directed.
S&F, factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tubes for top & bottom rails MS frame shall be covered with heat moulded plain cover PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for styles and plain colour PVC sheet for top rails lock rail and bottom rail on either side & as gap insert for top rail and bottom rail paneling of plain colour PVC sheet to be fitted in MS frame welded/sealed to the styles and rails with suitable PVC sheet beading and jointed together with solvent cement , as per specification and shown on drawing in SSR Part-II 2020 complete all as specified and directed.
S&F 150 mm long aluminium anodised, barrel tower bolts of extruded section and fixed etc complete all as specified and directed.
S&F 100 mm Butt hinges, extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed, type C-21 complete all as specified and directed.
S&F 150 mm dia extruded aluminium alloy handles, fabricated type, anodised complete all as specified and directed.
M&L for Brick work with fly ash bricks straight or curved on plan exceeding 6 m mean radius complete built in cement mortar 1:6 complete all as specified and directed.
M&L for Brickwork with flyash bricks, straight or curved on plan to any radius in half brick thick walls, built in cement mortar 1:4 complete all as specified and directed.
Taking down cement plaster on brick or concrete surface including racking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed.
M&L for Rendering 15 mm thick in cement mortar 1:6 on fair faces of brick work or concrete surfaces, finished even and smooth (without using extra cement) complete all as specified and directed.
M&L for preparation of newly plastered surfaces of walls and apply three coat of white wash complete all as specified and directed.
M&L Rendering 15 mm thick in cement mortar 1:4, in two layers (1st layer 10 mm thick rendering coat and 2nd layer 5 mm thick finishing coat) on brick work or concrete surfaces, second layer (finishing coat) mixed with liquid water proofing compound @ 200 ml / 50 Kg bag of cement as per manufacturer's instructions and finish the surfaces even and smooth without using extra cement complete all as specified and directed. Note : Liquid WPC will be measured and paid separately.
Supply only water proofing compound (liquid), ISI marked complete all as specified and directed.
M&L Rendering 5 mm thick in cement mortar 1:3 on concrete surfaces of ceiling and finishing the surfaces even and smooth complete all as specified and directed..
M&L preparation of newly plastered surfaces and applying three coats of white wash but on ceiling complete all as specified and as directed.
S&F 75mm PVC (SWR) floor trap, plain with grating,jointing with solvent cement as per site requrement all as specified and directed.
M&L for non skid ceramic coloured tiles of design as approved 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm in floor etc set and jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles complete all as specified and directed.
M&L for PCC 1:2:4 type B-0 using 12.5 mm graded stone aggregate as in sub base flooring average 25 mm thick surface finished even and rough (as in levelling course) to receive the topping layer complete all as specified and directed.
M&L for screed bed or bedding layer of mortar 15 mm thick for laying floor finishes in CM 1:6 for laying of floor tiles complete all as specified and directed.
M&L for Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m depth for foundation etc or for shafts, wells cesspits manholes pier holes etc not exceeding 10 Sqm on plan and not exceeding 1.5 m depth in soft /loose soil etc complete all as specified and directed.
M&L for salt glazed stoneware (SGSW) drain pipes laid in trenches of 150 mm internal diameter of pipe and jointed in CM 1:1 complete all as specified and directed.
M&L for cement concrete bed to drain pipes including packing under and haunching against the sides of pipe after they are laid & tested for 150 mm bore of pipe with cement concrete 1:3:6 type C-2 using 40mm graded stone aggregate complete all as specified and directed.
M&L Salt glazed stone ware gully traps size 150 x 150mm, square or round mouthed, type ‘P’ including setting and jointing to drains with CM 1:1 including demolition of existing traps complete all as specified and directed. (Note: CI grating will be meaured separately).
M&L for Returning, filing in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in any type of soil etc complete all as specified and directed
M&L for Removing excavated material (Soil) exc. 250 m but n exc. 500 m and depositing where directed complete all as specified and directed.
M&L for pre cast cement concrete 1:1.5:3, type A-1, using 20mm graded stone aggregate as in cover slabs (for manholes etc) and similar articles with plain faces, set in CM 1:4 complete all as specified and directed.
M&L for Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as speified and directed.
M&L for PCC 1:2:4 type B-1 using 20 mm graded stone aggregate as in lintels upto 1.5 m clear span, coping, benching, bed block, lintel band, plinth courses etc and similar work including weathering,slightly rounded or chamfered angles and throating including necessary form work complete all as specified and directed.
S&F mild steel framed work such as grills, gratings etc with ends of bars shouldered and / or riveted or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walkways, railings,frame work of watertanks and similar work conforming to Fe -290 Gde E-165 complete all as specified and directed.
M&L Excavating over areas in soft/ loose soil , n exc 1.5 m deep and getting out complete all as specified & directed.
M&L for hard core of gauge n exc 63 mm, deposited, spread and levelled in layers n exc 15 cm thick, watered and rammed to a true surface all as specified and directed.
M&L for 100 mm thick cement concrete 1:4:8 type D-2 using 40 mm graded stone aggregate as sub base of floor complete all as specified and directed.
M&L for Chequered cement concrete tiles 20cm x 20cm x 25mm thick, set, jointed and pointed in neat cement slurry in floors and pointed with grey pigment cement and pigments complete all as specified and directed.
M&L for screed bed or bedding layer of mortar 15 mm thick in CM 1:4 for laying floor finishes complete all as specified and directed.
M&L for 8 mm Seamless calcium silicate ceiling made out of 600 x 600 mm size board of siliceous and calcareous material reinforced with cellulose fibre fixed to the ceiling section with 25 mm long self drilling and tapping screws having phillips head with under head cutter at 200 mm centre to centre, including finshing the joint of face board with specially formulated jointing compound and 48 mm wide fibre tape to provide seam less finish (Frame work for ceiling shall be measured and paid separately
S&F Gl frame work for seamless ceiling comprising of Gl perimeter channnel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre complete all as specified .
S&F Hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specified
M&L for preperation & priming clearcolle on plastered and other surface , preparatory to distempering and apllying one coat of oil bound distemper on ceiling , complete all as specified
Taking down carefully copper/aluminium point wiring (light,fan,bell, socket or power) complete,including fixtures and fittings such as switches, ceiling roses, holders,regulators, sockets, tube light fittings i.e removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made for conditions separately ) and including making good the disturbed surfaces to match with existing surface and colour shade with proper putty for smooth finishing without andulations complete all as specified and directed.
Material and labour for point wiring complete with 1.5 sqmm, PVC insulated, FRLSH type, ISI marked,conforming to IS-694/1990(as amended) unsheathed, multistranded, single core, copper conductor cable 1100 volts grade using approved colour coding drawn through and including PVC concealed conduit 20/25 mm dia medium grade (MMS) and incliding all accessories such as bend,tee,elbows,reducers,bell mouth tube ends,short pieces & junction boxes with PVC covers etc in walls / roofs / floors / ceiling etc and including cutting, chasing work at any height with flush mounting GI sunken boxes having top,bottom,side/back side knockout for conduit entry from any direction made out of 1.60mm thick, 60mm deep for housing modular switches,sockets,fan regulators, Indicators,blank plate etc and incl Providing modular white cover plate with inner frame suitable as per switch modules and including PVC insulated multistranded copper conductor 1.5 sqmm FRLSH type unsheathed (Green colour),single core cable as earth wire connecting to common earth dolly for further connection to ceiling rose and earth terminal and including making good the disturbed surfaces to match with existing surface and colour shade with proper putty for smooth finishing with existing wall complete all as specified and directed for One light point controlled by one 10amps switch, one way. (Note:- All necessary accessories such as modular box,top cover plate,inner frame, blank plate,GI sunken boxes,screws,washers and all modular electrical fixtures are used same make/brand only)
All as per item no. 42 but One fan point controlled by one switch 10 amps, and one regulator.
All as per item no. 42 but One exhaust fan point controlled by one switch 10 amps,one way
All as per item no. 42 but One 5 pin 6 amps socket point controlled by one 10 amps switch on independent board .
All as per item no. 42 but One 5 pin 10 amps socket point controlled by one 10 amps switch on same board .
All as per item no. 42 but One bell/buzzer point controlled by one bell push.
All as per item no. 42 but One light point controlled by two 2 way switches.
All as per item No. 42 above,but point wiring with 2.5 sqmm and earth conductor of size 2.5 sqmm complete all as specified and directed for One 6 pin 16/20amps socket outlet point controlled by one 16/20 amps switch on independent board.
All as per item no. 49 One 6 pin 16/20 amps socket outlet point controlled by one 16/20 amps switch on same board.
All as per item No.42 above ,but point wiring with 4.0 sqmm and earth conductor of size 4 sqmm complete all as specified and directed.
Supply & fixing modular type switch 10 Amps, single pole,1way,1 module,240V,AC, with small indicator ISI Marked complete all as specified and directed.
Supply & fixing modular type switch 10 Amps ,2way,single pole,1 module,240V,AC, with small indicator ISI Marked complete all as specified and directed.
Supply & fixing modular type bell push 10 Amps,1 module, single pole, 240 volts,AC, with embosing bell simble & indicator, ISI Marked complete all as specified and directed.
Supply & fixing modular type switch 16/20 Amps, single pole,1way,1 module,240V,with small indicator,AC, ISI Marked complete all as specified and directed.
Supply & fixing modular type socket shuttered type 10 Amps, 2/3 Pin combined 2 module,240V,AC ISI Marked complete all as specified and directed.
Supply & fixing modular type socket 16/20 Amps, 6 Pin combined shuttered socket 2 module,240V,AC ISI Marked complete all as specified and directed
Supply & fixing red color lighting indication lamp switch, single pole,240volts,AC,50 Hz suitable for 1 module ISI Marked complete all as specified and directed.
Supply & fixing modular type step fan speed regulator 120W, 2 module,230volts,AC, 360 degree rotation 1 to 8 steps, ISI Marked complete all as specified and directed.
Supply and fix call bell AC, 230 Volts single pole, multi music type best and superior quality, ISI marked, as approved type complete all as specified and directed.
Supply & fix ceiling rose, 3 terminal ,PVC/polycarbonate body ISI marked, complete all as specified and directed
Supply only fixed in repairs recess mounting 2'x2' LED 36 Watt light fitting slimmest 9 mm thin in class LED ceiling panel with best in class aesthetick white powder coated frame blended seamlessly with ceiling layout suitable for 600X600mm mudular ceiling grid and also can be suspended with provided kit and including connecting up with ceiling rose to fitting and including removing old unserviceable item complete all as specified and directed complete all as specified and directed. Make :-Crompton/Havells/Philips
Supply & fixing and sheet metal enclosure with acrylic door type, double door ,415 volts AC,VTPN DB, 4 way,8+12 modules, flush mounting with 200amps copper busbar, 2 neutral/earth bars links and MCCB incomer, and MCB SPN/SP/TPN as outgoing and complete for IP43&54 DBs protection and including removing old unserviceable DBs and incl making good the disturbed surfaces to match with existing surface and colour shade complete all as specified and as directed.Make:-Legrand or equivalent make in ABB/Havells
Supply & fixing and sheet metal enclosure, with acrylic door type, double door, 240 volts AC,SPN,DB, 8 way, flush mounting with 100amps copper busbar,neutral bar,earth bar links and MCB incomer MCB SPN/DP and MCB SP as outgoing for IP 43& IP54 DBs protection nd including removing old unserviceable DBs and making good the disturbed surfaces to match with existing surface and colour shade acomplete all as specified and as directed. Make:-Legrand or equivalent make in ABB/Havells
Supply & fix MCB SP 6 to 32 Amps 10 KA,"C" series,AC,240Volts,50Hz , ISI marked and including removing old unsv items complete all as specified and directed.Make:- Legrand/ABB/Havells or as approved make
Supply & fix and MCB SPN 32 to 40 Amps 10 KA,"C" series,AC,240Volts,50Hz, ISI marked and including removing old unsv items complete all as specified and directed.Make:- Legrand/Hager/Havells or as approved make
M & L for sub main wiring complete with 2 run of 6 sqmm single core copper conductor (ISI marked)cable 1100 volts grade, ISI marked,FRLSH type (conforming to IS-694/1990 as amended) PVC insulated, unsheathed,flexible,multi stranded colour coded cables drawn through and including rigid PVC conduit concealed ISI marked medium grade(MMS) with all connected accessories such as Bend,Tee,Elbow,Short peices etc concealed in wall/roofs/floors and including one run of 4 sqmm single core copper conductor cable flexible, PVC insulated, unsheathed, multistranded, 1100 volts grade, ISI marked FRLSH type as earth continuity conductor connected to common earth dolly and including removing old unsv sub main wiring and making good the disturbed surfaces to match with existing surface and colour shade and complete all as specified and directed. Note : - Two run of 6 sqmm single core copper conductor cable and one run of 6 sqmm single core copper conductor cable as earth continuity and one run of PVC conduit shall be measured as one unit.
M & L for sub main wiring complete with 2 run of 4 sqmm single core copper conductor (ISI marked)cable 1100 volts grade, ISI marked,FRLSH type (conforming to IS-694/1990 as amended) PVC insulated, unsheathed,flexible,multi stranded colour coded cables drawn through and including rigid PVC conduit concealed ISI marked medium grade(MMS) with all connected accessories such as Bend,Tee,Elbow,Short peices etc concealed in wall/roofs/floors and including one run of 4.0 sqmm single core copper conductor cable flexible, PVC insulated, unsheathed, multistranded, 1100 volts grade, ISI marked,FRLSH type as earth continuity conductor connected to common earth dolly and including removing old unsv submain wiring and making good the disturbed surfaces to match with existing surface and colour shade and complete all as specified and directed. Note : - Two run of 4 sqmm single core copper conductor cable and one run of 4.0 sqmm single core copper conductor cable as earth continuity and one run of PVC conduit shall be measured as one unit.
Supply and fix suitable for flush mounting sheet steel enclosure metal clad plug and socket including MCB SP 20 Amps, 10KA 'C 'series, 230 Volts,50Hz suitable for AC's/Geysers complete all as specified and directed.Make:- Legrand / Hager/ Havells or as equivalent approved make
Supply and fix MCCB, 100 Amps,4 pole,415 Volts , 16/18KA thermal magnetic type with necessary lugs,thimbles, nuts bolts and washers and including removing old unserviceable item complete all as specified and as directed. Make:- Legrand / Hager/ Havells or as equivalent approved
Material and labour for Earthing complete with galvanised steel earth plate electrode 600mmX 600mmX 6mm thick buried directely in ground vertically ( earth pit not less than 2.25 meters deep below ground level) with top edge of plate not less than 1.5 metres below ground level, connected to and including galvanised iron wire 4 mm dia and light grade protection pipe of 15 mm dia from earth electrode up to test point or up to 7.5mtr whichever is less by means of GI bolts, nuts, check nuts and washers all as per electrical plate No 3 of SSR Pt-I and GI watering pipe of 20 mm dia medium grade,GI funnel with wire mesh,including charcoal, salt packed all around the earth electrode plate in layers, PCC earth pit chamber 1:3:6 type C1, of size 45X 45X 45 CM,RCC/(PVC hevy duty cover) cover 1:2:4 type B1 of size 45X45X6 CM, excavation/earth work in any strata and returning filling, removal of surplus soil and testing/test point for required value including removing old item complete all as specified and directed.
Supply and fix PVC casing and caping of size not less than 50X50 mm width with all accessories such as tees,corners,overlaping connector etc for encasing existing telephone cables, LAN cables,Cable wires etc along the wall/ceiling/roof etc complete all as specified and as directed.
S&F for PVC non-metalic rigid conduit incl boxes,junctions boxes 1 to 4 way & terminals but incl of all tees,bends,elbows,reducers,bell mouth tube ends and fixing accessories such as couplers lock nuts,saddles,pipes hookes etc ISI marked heavy duty of size 20/25 mm dia for LAN,telephone and TV connections including cutting,chasses and making good disturbed surfaces to match with existing surfaces with plaster/putty and including removing of old unserviceable item complete all as specified and directed. Make of PVC conduit (HMS)/ & Accessories ISI Marked :-Presto Plast/Finolex/Kalinga Gold/Plaza/AKG Plastics Pvt Ltd
Design,Supply,Install,Commissioning and Testing of 03 Nos X 8.5 TR ( Total 25.5 TR) capacity Air Cooled DPA type floor mounted ductable package type air condition units with micro processor comprising hermatic sealed scroll type compressor with microprocessor based control indipendent compressor housed inside the units independently and including providing necessary refrigerant heavy duty copper piping,electrical inter connections between indoor and out door units with suitable rating copper cables,suitable operating with the refrigerant R-410A in indoor unit. The centralised package type air conditioner for 3 Nos 8.5 TR units designed to work effectively even in ambient temperature as higher as 50 degree centi grade and electrically operated on three phase,AC supply,415 Volts,50Hz and duly mounted on floor, and including providing necessary foundations as per indoor units size, service-friendly design,lower noise levels,blue fin condenser and corrosion-resistant body,wide voltage range,multi-compressor advantage,run-time equalisation,Hydrophilic coating,EPE insulations,DIDW blower design,Efficient Airfilters and vaccumizing gas charging,nitrogen pressure testing and the air cooled package type air conditioner shall have the following fittings/accessories fitted complete all as specified and directed.(Make:-8.5 TR of DPA 1021 R3 Type package air conditioner from any approved brand)(a) (i) Scroll Compressor Driven: Hermatically sealed scroll type compressor with motor of matching capacity,electrically operated on three phase,415 volts,50Hz,AC supply complete with suction and discharged shut off valves, automatic capacity control with thermostart and solenoid valves,built in suction strainer,oil pump,hot gas mufler,oil pressure safety switch etc all as specified and directed.(ii) 03 Nos air cooled type copper tube condenser assembly suitable for 8.5 TR package type air cooled plant complete as as specified and directed.(iii) Cooling coils made up of inner grooved copper tube with aluminium slit fins. The Copper fins on evaporative coil have a hydrophilic or equivalent coating.(iv) Filter made up of non-woven polyster media enclosed by HDPE mesh,filter plenum and by pass dampers as required at site with 90% efficiency to 20 microns.(v) In built blower for weather makers complete for AC plant.(vi) The plant having the provision of high/low voltage protection,phase inbalance voltage,phase loss protection for three units independantly(vii) Expansion valves and pilot solenoids valves for three units independantly.(vii) Three sets of spring anti-vibration serrated pads suitable foundation as per manufacturer's instructions for installation of above three package units independantly.(viii) Necessary copper piping for liquid line complete with fittings,valves,etc for installation of above three package units independantly.(viii) First charging of Non -CFC refrigerant gas and coil for the three units independantly/complete.(b) Intelligant Microprocessor Controller :-All units are controlled by micro processor-based controllers with the following features separately.(i) Seven signal LCD display.(ii) Auto restart after power failure(iii) faulty display(iv) Run-time equalisation(v) Non -volation memory(vi) Touch-key on /off switch(vii) Single-phasing and phase reversal protection(viii) Time delay for compressor operation(ix) Accurate temp.control +/- 10 degree centigrade.(x) Provision for fire alarm input .(c) The package type unit shall be self contained units generally comprising to IS-8148-1976.The plant may have single or multi refrigerant circuit as per designed respective manufacturer.Each compressor shall have a independent condensor,evaporator and Refrigerant system separately.(d) One lot of air distribution system from package units to where necessary insulations for complete supply air duct by providing 19 mm thick nitrile foam and side laminated including suitable supporting as per IS-65 comprising of class VIII galvanised sheet with suitable supporting arrangements and bracing,branching,supply/return/fresh air grills on aluminium frame work duly painted/finished to match with the existing ceiling,fire damper fusible link operated.(e) Supply, install, erection, commissioning and testing of hollow factory fabricated SITC of GI ducting of guage 22 & 24. 80% of GI duct factory fabricated and 20 % of GI duct site fabrication and suitable insulation and weather protected from out side plant room. Supported on steel structure as per standard specifications complete along with provision of aluminium clading for exposed surface of GI ducts and canvas cloth/ insulated material and including providing necessary supports,nuts,bolts,anchor bolts and washers and necessary accessories (f) installation,Testing of copper refrigerant pipe of approved thikcness heavy duty type with fittings,elbows,harden copper pipes with 9 mm nitrel insulation at factory fabrication ducts and site fabrication ducts as per site requirement complete all as specified and directed.(g) Supply and fixing of PVC sheathed electrical copper cable of suitable size and ampere rating for IDU & ODU complete as specified and directed.(h) Supply first filling of Refrigerant 410A for all unitscomplete all as specified and directed.(j) Supply & installation of accoustic insulation with rigid board(48kg density) in factory fabricated ducts and site fabricated ducts complete all as specified and directed.(k) Supply and fixing PVC, 25 MM dia water drain piping work properly fixing at along with the esxisting wall including providing necessary GI clmps,nuts,bolts and washers complete all as specified and directed.(l) Necessary PCC foundation,GI stand for 8.5 TR package type air conditioner out door units complete all as specified and directed.(m) Supply and installation of aluminium powder-coated continuous linear grilles and necessary fixing arrangements as per site requirements complete all as specified and directed.(n) supply and installation of duct volume control dampers/back draft dampers constructed out of GI sheet complete all as specified and directed.(o) supply and fixing vibration rubber pads for 8.5 TR out door unit legs complete all as specified and dircted.(p) Provision of necessary PCC foundation/Civil work for installation of above AC plant and making good the disturbed surfaces,walls,wall surfaces,floors etc complete all as specified and directed.(q) Necessary testings carried out after ianstallation are as followings:-(a) Compressor - High/Low Ampere triping testing(b) Temparature testing.(c ) Air Cooling testing(d) Oil presure testing(e) Vaccumizing gas charging and nitrogen pressure testing Note-1:- Demolition of brick work, Taking down wooden ventilators,exhaust fans,new brick work,plastering,white wash,distember etc items will be measured and paid separately in relavent items
Demolition of bricks or stone/boulders masonry built in cement motor including all quoins,arches,pillars etc complete all as specified and directed.
Taking down wooden ventilator windo with shutter frame n exc 1.5 sqm each with shutters complete all as specified and directed.
M&L for old size brick work with fly ash bricks straight or curved on plan exc 6m mean radius in CM 1:6 complete all as specified and directed.
M&L for rendering 15mm thick on fair face of brick works in CM 1:6 finished even and smooth with out using extra cement complete all as specified and directed.
M&L for preparation of new plastered surface of walls or concrete and applying two coats of oil bounded distemper over a coat of primer complete all as specified and directed
M&L for preparation of old decorated surface of wall and apply two coats of white wash complete all as specified and directed
M&L for applying two coats of oil bound distember on wall or concrete over a coat of primer on prepared surfaces including,rubbing with sand paper after complete removal of existing treatment complete
Supply,install,hi wall split units indoor/outdoor complete with cordless remote control unit and complete indoor and outdoor units and standard accessories with minium 5 star rating of capacity 1.5 TR for complete all as specified and directed
Supply,Install,Testing and Commissioning of step down 11 KV transformer,level-2,Voltage rating 11KV/0.433 Volts,out door type of capacity 160 KVA,,3 Phase,4 Wire,50 Hz, oil cooled, core type, floor mounted, Delta/star connected maximum losses as defined in vector group DYN 11,Double copper wound ONAN manual type off load tap changing facility on HT side to vary secondary voltage from +/- 7.5 % in steps of 2.5 % continuous rating of capacity 160 KVA incl cable end box on both HT & LT side .The transformer shall be completed with all standard fittings and accessories, guages and including providing first fill transformer oil as as per indication level etc and confirming to IS :1180 and fittings and accessories of transformers shall confirm to IS 3639-1996 as amended and duly mounted on rollers as per load bearing capacity of transformer and the transformer shall have the following fittings/accessories fitted complete all as specified and directed.(i) HV Primary side consisting of 03 Nos porcelain insulated bushing with brass bushing rods and nuts,bolts and washersand 01 No cable end box as per OEM guage.(ii) LV Secondary side cosisting of 04 Nos porcelain insulated busthing with brass bushing rods and nuts,bolts and washers and 01 No cable end box as per OEM guage.(iii) Rating plate and terminal marking plate of HT/LT sides(iv) Two earthing terminals for body earthing and two additional for neutral brought out on a bushing(v) One number Thermometer dail type vapour presure type having range 0-120 degree centigrade with maxiumum temperature indicator and re-setting device to maximium tempratur including needle of temprature guage:max reading painted terminal(vi) Lifting Lugs(vii) Dehydrating silicagel breather(viii) Oil level indicator with minium and maximum marking (ix) Cooling Radiator(x) Thermometer pocket(xi) Drain valve with plug or cover plate(xii) Conservator tank(xiii) Oil filling hole with cover including funnel(xiv) Air release device/plug(xv) Thermometer 100 mm dia/stem type with metal guard having maximum temperature indication with resetting devices for transformer (xvi) Winding temperature indicator(xvii) Air release device for transformer(xviii) First fill of suitable grade transformer oil confirming to IS and tested upto 60KV die electric strength.Make:- SEIMENS / SCHNEIDER / ABB or equivalent approved makeNote 1:- Information plate /Technical data plate as laid down in para 15.2 and 15.3 as per IS.Note 2:- Including making PCC foundation for transformer of size of 2.0 mtr X 2.0 mtr X 1.30 mtr (below ground level 0.3 mtr and above ground level 01 mtr and incl providing GI cattle fencing up to 1.50 mtr height all-around up to 2.5 mtr width from the transformer foundation corner to fence and suitable GI gate and locking arrangements complete all as directed by Engr-in-Charge.Note-3:- Exc,RFR,PCC and GI metal fencing with gate items will be measured and paid separately in relavent items
Supply, Install, Testing and Commissioning of 11/12 KV, SF6 Load Break Switch (LBS) , 3 Pole, Rating capacity 630 Amps,50 Hz which confirms to IEC 62271-1 standards Outdoor type in CRCA powder coated steel enclosure, 3 mm thick and the main frame is welded in steel structures fabricated load break switche Panel.The unique arc quenching mechanism makes it capable of breaking normal loads and fault loads.This can be operated on loads up to 1 MVA with epoxy insulators suitable rating, HT three pole busbar of rating 1.5 times capacity of LBS , double switch blades,forged contacts with arc quenching chamber, lagging pin and loop less current path. The nylon/FRP insulaton makes the switch light weight with greater electrical safety and mechanical strength load break switch panel and the contacts are mounted on epoxy insulators and operated the switch is also provided with stored energy tripping device and tripping intiantion by means of fuses rated short circuit making capacity upto 20 KA (RMS) 50 KA (PEAK) and make/break upto 630 Amps and mechanically interlocked earth switch and manually operated mechanical system and incoming and outgoing cable entries with necessarybase foundation in PCC 1:2:4 and the Manufactured shall be CPRI norms followed and drawings/circuit layout approval by Engr-in-Charge.
M&L for galvanised iron metal fencing for 11 KV substation and including providing necessary fabrication work,welding, & drilling work,bending,cutting,nuts,bolts and washers etc for transformer fencing and gate with locking arrangements with 12mm square/round galvanised iron steel bars not exc 12 cm size of apreature and necessary galavanised 100mm GI channels of length 2 meters heigh incl errection of channels 0.5mtr below ground level and 1.5 mtr above ground level with proper foundation and coping two coats of red oxide primer and two coats of anti-corrosive silver paint complete all as specified and directed.
Supply, laying & testing 11 KV grade cable XLPE/PVC insulated, screened, PVC bedded,galvanized steel strip or wire armoured, electric power cables (heavy duty ) with stranded aluminium conductor,11000 volts (Earthed) grade, of cross sectional area 95 sqmm,3 core complete all as specified and directed.Make:-Havells india Ltd/Polycab wires Pvt Ltd/Gloster cables Ltd(Note:-(i) Excavation,Earth work,sand cushioning,cable covers and cable protection pipes shall be measured and paid separately.)(ii) The cable shall be in one length unless otherwise directed by GE.
Supply and fix cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 to185 sqmm complete all as specified and directed.Make: Raychem/M-Seal/Denson
Supply and fix cable jointing kit for 11 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 to185 sqmm complete all as specified and directed.Make: Raychem/M-Seal/Denson
M&L for steel tubular swaged type poles 11 metrs long,pole weight approximately 178 to183 kgs, pole should be in one piece only and smooth finishing,ISI marked complete with all accessories such as cast iron base plate, finial taper plug,bolts, nuts, screws,washers and drilling of holes for continious GI earth wire as specified type 410 SP-55 including applying two coats of aluminium paint over one coat of red oxide zinc chrome primer and embedded portion shall be painted with two coats of black paint after preparation of surface complete all as specified and directed make as approved.Make:- Fabrico(india)Pvt Ltd or any approval make
Supply and fix and in repair 11 KV out door type Air Break gang operated device of rating 200 Amps, triple pole, vertical type,mechanically operated, mounted on HT insulators and steel channel frame with operating machanism worked from ground level with GI tubing 25 mm dia medium grade with operating handle and locking arrangement including seven lever navtal lock and providing ACSR conductor jumpers duly crimped with lugs, connecting to existing 11 KV supply cand testing complete all as specified and directed.Make :- Atlas/Elpro/ECE/Pactil/Oblum
Material and labour for galvanised iron (GI) cross arms, bracings, supports, GI clamps and back plates fabricated from galavanised iron steel structural sections including GI nuts, bolts, washers and necessary fabrications,cutting, welding, bending colt or hot, drilling holes for nuts,bolts, in any shape or size as indicated or directed and inclusive of red oxide primer two coats and two coat of aluminuim anti corrosive paint all as specified and directed.
M&L for in repair aluminium conductor with steel reinforced galvanised wire conductor drawn for overhead lines/jumpers etc for two/four pole structuring/existing connection as per site requirement and complete all as specified and directed
M&L for two -in - series assembly for tension with clamps for conductors, working pressure 11000 volts as per site requirement or and complete all as specified and directed
M&L for single disc assembly for tension with clamps for conductors, working pressure 11000 volts as per site requirement or and complete all as specified and directed
M&L for pin type porcelain ,vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one iron nut ,150 mm height,150 mm dia for 11000 volts grade complete all as specified and directed
M&L for danger notice plate of size 250 x 250mm and 1.6 mm thick galvanised steel plate,vitreous enammelled white, with letters,figures and conventional skull and bones in signal red colour and fixed with GI clamps,bolts and nuts of above size, for HT, 11000 volts grade complete all as specified and directed
Material and labour for GI earth continuity strip of size 32x6 mm complete all as specified and directed.
Material and labour for rubber mat of 1 mtr x 2 mtr x19 mm complete all as specified and directed
Supply, laying & testing PVC insulated armoured, heavy duty electric cable with stranded aluminium conductor,1100 volts of cross sectional area 25 sqmm,4 core including testing complete all as specified and directed.Make:-Havells/polycab/Anchor
Supply, laying & testing PVC insulated armoured, heavy duty electric cable with stranded aluminium conductor,1100 volts of cross sectional area 35 sqmm,4 core including testing complete all as specified and directed.Make:-Havells/polycab/Anchor
Supply, laying & testing PVC insulated armoured, heavy duty electric cable with stranded aluminium conductor,1100 volts of cross sectional area 95 sqmm,4 core including testing complete all as specified and directed.Make:-Havells/polycab/Anchor
Supply, laying & testing PVC insulated armoured, heavy duty electric cable with stranded aluminium conductor,1100 volts of cross sectional area 120 sqmm,4 core including testing complete all as specified and directed.Make:-Havells/polycab/Anchor
Supply, laying & testing PVC insulated armoured, heavy duty electric cable with stranded aluminium conductor,1100 volts of cross sectional area 185 sqmm,4 core including testing complete all as specified and directed.Make:-Havells/polycab/Anchor
Supplying and laying reinforce precast concrete cable cover class HT, Type 1,flat, size 300mm x180 mm x 40 mm for protection under ground HT cable complete all as specified and directed
Supply and laying bricks burnt clay bricks sub class 'B' for cable of size 250 x 115 x 75mm for protection under ground cable complete all as specified and directed
M&L for rough exc not exceeding 1.5 mtr deep and getting out at any places complete all as specified and directed.
Supply and spreading stone agrregate 20 to 40 mm laying,deposited,spreading and levelled in layers n exc 15 cm thick, watered and rammed to a true surface at around the newly installed transformer complete all as specified and directed
Supply and spreading stone agrregate chips of size 10 to 20 mm laying,deposited,spreading and levelled in layers n exc 15 cm thick, watered and rammed to a true surface at around the newly installed transformer complete all as specified and directed
Material & labour for GI pipe 80 mm "light grade" laid in trenches floors/on , pole/road for cable protection with all fittings complete all as specified and directed .Make: Tata/Swastik/Jindal
Boaring holes excavation by trencheless technology across the road,pavement,hard standing by trenche technology using ultra sounding technique and necessary machine and necessary T&P and including providing cable protection HDPE ring pipe 100MM dia heavy duty suitable for 0.4 mpa working for passing of UG cable and without any damages the existing road surfaces and any other UG cables, signal cables, OFC cables and any other assets complete all as specified and as directed.Note:- During excavation/trencheless excavation any other assetes damaged on site the contrator should be responsible for the making good and including replacing the new material/ item incl labour& repair cost etc with out any extra cost from the department.
Supply and providing river sand for cushioning with dry clean sand 15 cm below cable and 8 cm above the under ground cables and necessary fillings in the trenches and punning to provide required cover complete all as specified and directed.
Excavation in trenches soft loose soil exceeding 1.5 mtr depth and not exc 3.0 mtr depth and not exceeding 1.5 mtr wide for foundations etc and getting out in soft loose soil complete all as specified and directed.
Material and labour for PCC 1:4:8 type D2 using (40 mm graded stone aggregate) for making good cutting portion, mass concrete, filling of foundations etc including necessary use and waste of form work complete all as specified and directed
Material and labour for PCC 1:3:6 type C2 using (40 mm graded stone aggregate) for making good cutting portion mass concrete, filling of foundations etc including necessary use and waste of form work complete all as specified and directed
Material and labour for PCC 1:2:4 type B-1 using (20 mm graded stone aggregate) for making foundation/base plinth and pole coping, foundation etc including necessary use and waste of form work complete all as specified and directed.
Material and labour for Earthing complete with galvanised steel earth plate electrode 600mmX 600mmX 6mm thick buried directely in ground vertically ( earth pit not less than 2.25 meters deep below ground level) with top edge of plate not less than 1.5 metres below ground level, connected to and including galvanised iron wire 4 mm dia and light grade protection pipe of 15 mm dia from earth electrode up to test point or up to 7.5mtr whichever is less by means of GI bolts, nuts, check nuts and washers all as per electrical plate No 3 of SSR Pt-I and GI watering pipe of 20 mm dia medium grade,GI funnel with wire mesh,including charcoal, salt packed all around the earth electrode plate in layers, PCC earth pit chamber 1:3:6 type C1, of size 45X 45X 45 CM,RCC cover 1:2:4 type B1 of size 45X45X6 CM, excavation/earth work in any strata and returning filling, removal of surplus soil and testing/test point for required value including removing old item complete all as specified and directed.
Material and labour for earthing complete with galvanised steel earth plate electrode 600mmX 600mmX 6mm thick buried directely in ground vertically ( earth pit not less than 2.25 metres deep below ground level) with top edge of plate not less than 1.5 metres below ground level, connected to and including galvanised iron strip of size 32 X 6 mm from earth electrode to test point or up to 7.5mtr whichever is less by means of GI bolts, nuts, check nuts and washers all as per electrical plate no 3 of SSR Pt-I and GI watering pipe of 20 mm dia medium grade,GI funnel with wire mesh,including char coal, salt packed all around the earth electrode plate in layers,PCC earth pit chamber 1:3:6 type C1,RCC cover 1:2:4 type B1, including excavation,earth work in any strata and returning filling, removal of surplus soil and testing for required value complete all as specified and directed.
M/s Bapujee Builders and Traders
M/s Ats Electricals
M/s TECH TEAM
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .