Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.5 LAccepted-AOC | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹13.7 L+₹16,446 (1.22%)Rejected-Finance 29 108 A STREET NO 10 VISHWAS NAGAR DELHI 110032 | DELHI | SHAHDARA | DELHI | 110032 | L2 | Rejected-Finance Not Lowest Bidder | |
| 3 | L3₹13.9 L+₹40,392 (2.99%)Rejected-Finance | L3 | Rejected-Finance Not Lowest Bidder | |
| 4 | L4₹15.3 L+₹1.8 L (13.0%)Rejected-Finance WZ 346 E IIND FLOOR NEAR SALVAGE PARK NANGAL RAYA NEW DELHI 110046 | NEW DELHI | DELHI | 110046 | L4 | Rejected-Finance Not Lowest Bidder | |
| 5 | L5₹15.5 L+₹2.0 L (14.8%)Rejected-Finance | L5 | Rejected-Finance Not Lowest Bidder |
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
17 Jun 2023, 6:00 pmClosed
GE South Delhi Cantt-10
GE South Delhi Cantt-10
WELCOME MAINT AND OTHER CONNECTING B/R AND E/M ITEMS TO ANUJ VIHAR OFFRS MD ACCN UNDER AGE B/R-I AND AGE E/M OF GE (SOUTH) DELHI CANTT-10
2023_MES_598972_1
GE/DS-23/2023-24
Open Tender
Civil Works
Item Rate
270 days
GE South Delhi Cantt
Please refer Tender documents.
11 documents required · 11 mandatory
₹500
GE South Delhi Cantt
₹70,000
Yes
7 Jul 2023
27 May 2023
19 Jun 2023
27 May 2023
17 Jun 2023
10 Jun 2023
Amount
M&L for preparation of old decorated surfaces of wall (plastered or unplastered) including cornices pillasters and other wall features by brooming down smoke, soot moulds and efflorescent salt and trading oil or greasy spots applying one coat of white wash to obtain uniform surfaces including scafolding arrangement, trestles, ladders etc. complete all as specified and as directed.
All as per Srl No. 1 above but on ceiling surfaces.
M&L for preparing of old decorated surfaces of (Plastered or unplastered) including cornices pillasters and other wall features by washing, rubbing down and stopping of distempered and painted surfaces of walls and applying one coat of oil emulsion distemper white or tinted including scaffolding arrangement, trestles, ladders etc. complete all as specified and as directed.
All as per Srl item No.3 above, but two coats of oil emulsion distemper.
All as per Srl item No.3 above, but in patches of area exc 1.5 Sqm and n.exc 3.00 Sqm each to match the existing surface.
All as per Srl item No.3 above, but on ceiling surfaces
All as per Srl item No.3 above, but two coats of oil emulsion distemper on ceiling.
All as per Srl item No.3 above, but in patches of area exc 1.5 Sqm and n.exc 3.00 Sqm each to match the existing surface/colour on ceiling
Complete removal of existing treatment by mechanical grinder from wall and applying two coat of oil emulsion distemper white or tinted over and incl a layer of wall care putty for smooth surface including scaffolding arrangement, trestles, ladders etc. complete all as specified and as directed.
M&L for preparing of old painted surfaces of wood or wood based materials of any description over 10 cm width or girth and applying one coat of synthetic enamel paint on wooden surfaces complete all as specified and as directed.
M&L for preparing of old painted surfaces of steel of any description over 10 cm width or girth and applying on coat of synethic enamel paint on wooden surfaces complete all as specified and as directed.
Taking down cement plaster on brick walls including raking out joints, hacking for key, scrubbing down with water complete all as specified and as directed.
M&L for 15 mm thick rendering external with ready mix plaster (as manufacturr's instructions) in patches on faces of bricks or concrete surfaces, finished even and smooth without without using extra cement complete all as specified and as directed.
M&L for 10 mm thick rendering internal with ready mix plaster (as manufacturr's instructions) in patches on faces of bricks or concrete surfaces finished even and smooth without without using extra cement complete all as specified and as directed.
M&L 5 mm thick rendering on ceiling with ready mix plaster (as manufacturr's instructions) in patches on faces of bricks or concrete surfaces, finished even and smooth without without using extra cement complete all as specified and as directed. Notes for Srl item No.13 to 15 :- 1. Make of readymix plaster shall be Birla Aerocon/Ultratech Readiplast/ACC Accoplast/Fosroc Chemical (India) Pvt Ltd Renderoc and as approved by GE) 2. The readymix plaster shall be procured directly from the manufacturer or their authorised dealer.
M&L for preparation of newly plastered surfaces of wall and applying applying two coats of oil emulsion distemper white or tinted over and incl wall care putty to make smooth surface including scaffolding arrangement, trestles, ladders etc. complete all as specified and as directed.
M&L for preparation of newly plastered surfaces on external wall/ ceiling, applying two more coats of 100% premium acrylic emulsion paint having VOC less than 50 gm/ litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance eterior paint of required shade(Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 Sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 Sqm complete all as specified and as directed.
M&L for preparation of newly plastered surfaces of ceiling and applying applying two coats of oil emulsion distemper white or tinted over and incl wall care putty to make smooth surface including scaffolding arrangement, trestles, ladders etc. complete all as specified and as directed.
S&F in repairs of 15mm bore PTMT bib tap complete all as specified and as directed.
S&F in repairs brass chromium plated bib tap long body of 15mm bore fancy type fixed to iron pipe complete all as specified and as directed.
S&F in repairs 15mm dia brass chromium plated pillar tap with fly nuts capastan head screwed down high pressure with or without lettered hot or cold with long scewed shank complete all as specified and as directed.
S&F in repairs chromium plated brass stop cock fancy type (concealed type)screwed both ends high pressure for 15mm bore size iron pipe or ferrule complete all as specified and as directed.
S&F in repairs chromium plated brass angle valve fancy type suitable for 15mm bore pipe complete all as specified and as directed.
S&F in repairs chromium plated brass two way angle valve fancy type suitable for 15mm bore pipe complete all as specified and as directed.
S&F in repair chromium plated brass shower rose swival type 50mm with arm fancy type suitable for 15mm bore pipe complete all as specified and as directed.
S&F in repairs PVC connection 450mm long with 2 Nos brass check nuts suitable for 15mm bore of pipe with washer complete all as specified and as directed.
S&F in repairs waste fitting (coupling) brass chromium plated 32mm dia for WHB complete all as specified and as directed.
S&F in repairs 10 ltrs PVC (White) valve less syphonic action type, flushing cistern low level with inlet ball valve float, handle, Aluminium brackets for bottom support fixing with gitties embeded in wall with drilling machine etc. complete all as specified and as directed.
S&F in repairs brass CP kitchen sink mixer swival swan neck type for mixing Hot and cold water screwed down for iron pipe complete all as specified and as directed.
S&F in repairs 15mm dia wash hand basin CP brass mixer as in repair complete all as specified and as directed.
S&F in repairs 32/40mm bore and 75cm long PVC waste pipe suitable for WHB/Sink complete all as specified and as directed.
S&F brass chromium plated health faucet for WC with 1.20 Mtr long PVC flexible pipe complete all as specified and as directed.
S&F in repair soap dish chromium plated brass fixed with brass nuts and screws as in repair complete all as specified and as directed.
M&L for toilet paper holder brass chromium plated as in repair complete all as specified and as directed.
S&F in repairs plastic water closet (EWC) seat cover white closed pattern with flat bottom and cover incl mild steel chromium plated hinging device complete all as specified and as directed.
S&F in repairs viterous china wash down water closet pan (EWC) white incl 'P' or 'S' trap and making good the disturbed surface to match with the existing complete all as specified and as directed.
S&F vitreous china squatting pan (Orissa pattern) long pan including provision of lime concrete bedding fixed in repair size 580x440mm white with intergral footrest with 'P' or 'S' trap complete all as specified and as directed.
S&F in repairs vitreous china wash hand basin, white flat back size 550x400mm (excluding taps, waste, pipe chain and plug) but including porcelain stopper and a pair of MS bracket etc complete all as specified and as directed.
S&F in repairs 3mm thick sheet glass, plain ordinary quality not exc 0.5sqm in each pane complete all as specified and as directed.
S&F in repairs galvanised mild steel wire cloth 0.56 mm nominal dia of wire and average width of aperture 1.18mm and fixed with tied tacks or galvanised wire stapple etc. to wooden/steel doors/windows complete all as specified and as directed.
S&F in repairs Stop/angle valve of PTMT any colour high pressure screwed for iron pipe and fixed (Minimum weight 20mm-112gms) complete all as specified and as directed.
S&F in repairs rotational moulded polythelene water storage tank (cylindrical vertical with closed top) hoisted and fixed in position of 1000 ltr capacity including taking down old with and incl 20mm brass float valve complete all as spd in SSR and complete all as specified and as directed.
S&F in repairs rotational moulded polythelene water storage tank (cylindrical vertical with closed top) hoisted and fixed in position of 500 tr capacity including taking down old with and incl 15mm brass float valve complete all as spd in SSR and complete all as specified and as directed.
S&F in repairs vitreous china wash hand basin, white ovel shape as per existing size fixed in position (excluding taps, waste, pipe chain and plug) but including porcelain stopper and a pair of MS bracket etc. complete all as specified and as directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding ( but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed.
M&L for Non Skid ceramic tiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.06 Sqm but not exceeding 0.11 Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white cement to match over and including 15mm thick screed bed in cement mortar 1:6 for laying floor finish complete all as specified and as directed.
M&L for vitrified ceramic tiles 10mm thick (square/ractangular) polished, area of each tiles not exceeding 0.36 sqm in floor etc set and jointed in neat cement slurry and pointed in white/coloured cement to match over and incl 15mm thick cement mortar 1:6 complete all as specified and as directed.
All as per Srl item No.48 above, but as in vertical surfaces.
M&L for glazed ceramic tiles coloured in vertical surface 300x200x7mm thick set and jointed in neat cement slurry and pointed in white cement to match over and including 10mm thick screed in cement mortar 1:4 complete all as specified and as directed.
S&F in repairs 16 mm outer dia PE-AL-PE pipe of approved make complete all as specified and as directed.
S&F in repairs 32mm outer dia PE-AL-PE pipe of approved make complete all as specified and as directed.
S&F in repairs 40mm outer dia PE-AL-PE pipe of approved make complete all as specified and as directed.
S&F in repairs brass L-bow / Socket / T of size12x16mm fixed to PE-AL-PE pipe of approved make complete all as specified and as directed.
S&F in repairs brass reducer of size12x16mm to 16x20mm fixed to PE-AL-PE pipe of approved make complete all as specified and as directed.
S&F in repairs brass union of size12x12mm fixed to PE-AL-PE pipe of approved make complete all as specified and as directed.
Demolition of brick work built in cement mortar including removal from site complete all as specified and as directed.
M&L for brickwork with subclass `B` bricks, in straight or curved on plan exc 6m mean radius, built in CM 1:6 complete all as specified and as directed.
Taking down aluminium/copper point wiring (light, fan, socket or power and including all fitting) for taking credit and making good disturbed surfaces of walls, floors etc. complete all as specified and as directed.
M&L for point wiring complete, standard copper conductor 1.5 Sqmm nominal area PVC insulated FR-LSH 1100 volts grade electrical cable in and including suitable size of concealed/surface PVC conduit/ casing caping medium grade and sunk in pressed steel terminal boxes of required size with top cover 3 mm thick plastic/laminated sheet of required color with screwed and cup washer complete with all accessories including 1.5 Sqmm standard copper conductor PVC unsheathed cable earth and connected to earth dolly complete all as specified and as directed. Note :- In existing conduit wiring new conduit will be added where there is a burnt/blokage/damage to the existing conduit including bends/elbows/tees/Junction boxes. (a) One light / fan/bell point controlled by one switch SP, one way,
All as above Srl item No.60 above, but one 3 pin socket outlet 5/6 Amps on same board.
All as above Srl item No.60 above, but one socket outlet 5/6 Amps on independent boardwith cable 2.5 Sqmm for phase & neutral and for earth 2.5 sqmm.
All as above Srl item No.60 above, but one power socket 15/16 Amp with cable 4 Sqmm for phase & neutral and for earth 4 sqmm.
S&F switch piano flush type 6 Amps SP one way complete all as specified and as directed.
S&F switch piano flush type 6 Amps SP 2-way complete all as specified and as directed.
S&F bell push, flush type 6 Amps complete all as specified and as directed.
S&F socket outlet 6 Amps flush type 3 pin complete all as specified and as directed.
S&F switch piano type 16 Amps SP one way complete all as specified and as directed.
S&F lamp holder bakelite insulated body with back plate suitable for batten fitting complete all as specified and as directed.
S&F PRCD 16 AMP, 30 mA plug Top complete all as specified and as directed.
S&F in repairs socket outlet 2 in 1 (multipurpose) 6 pin 6 and 16 Amps flush mounted type complete all as specified and as directed.
S&F in repairs switch socket combination 2-in-1, 6 Amps with gang box flush type complete all as specified and as directed.
S&F in repairs switch socket combination 2-in-1 6 & 16 Amps with gang box flush type complete all as specified and as directed.
S&F in repairs switch socket combination 2-in-1, 6 Amps flush type complete all as specified and as directed.
S&F in repairs switch socket combination 2-in-1 6 & 16 Amps flush type complete all as specified and as directed.
S&F fan regulator electronic, stepped type, Switch type, suitable for ceiling fan 1200/1400mm sweep complete all as specified and as directed.
S&F Tee cover of suitable size as per existing complete all as specified and as directed.
S&F bell Ding dong type 230 volts single phase complete all as specified and as directed.
S&F in repairs LED Batten T-5 fitting 20 watt LED White, indoor decorative pvc extruded T5 LED battern -integrated type complete including taking down of old unsv existing 36 Watt tube light fitting complete all as specified and as directed.
S&F in repairs LED Integrated Batten T-5 10 watt - 2 FT White, indoor decorative pvc extruded T-5 LED battern -integrated type complete with including flexible wire including taking down of old unsv existing 18 Watt tube light fitting complete all as specified and as directed.
S&F in repairs LED 10 watt white Bulk head in engineering plastic housing with clear prismatic including all accessories connecting up twisted flexible copper conductor cable of suitable size of 230 V, 50 Hz complete all as specified and as directed.
S&F in repairs surface mounting round/square shaped LED downlighter with PDC pvc housing 6 Watt LED lamp type including taking down of old unsv existing CFL fitting any type from ceiling of stairs/common areas complete all as specified and as directed.
S&F in repairs old unserviceable wall light fixture any type with Wall mounting fitting City-4, Decorative wall light fixture made up of Polycarbonate, of B-22 base including 12 Watt LED Bulb of 6.5K complete all as specified and as directed.
S&F in repairs MCB SP 06 to 32 Amps 240 Volts, 10 KA, `C' curve, all as per site requirement complete all as specified and as directed.
S&F in repairs MCB SPN 40 Amps, 240 Volts, 10 KA, `C' curve, all as per site requirement complete all as specified and as directed.
S&F in repairs MCB SPN 63 Amps, 240 Volts, 10 KA, `C' curve, all as per site requirement complete all as specified and as directed.
S&F in repairs Circuler Hylam/PVC Sheet upto 10 Cm dia of 3 mm thick (for using as Junction box Cover) including screws and cup washer complete all as specified and as directed.
S&F in repairs PVC insulated FRLS single core with stranded copper cable of size 1.5 Sqmm single core for any type of wiring as per site requirement and directed in Red/Blue/Yellow&Black&green colour complete all as specified and as directed.
S&F in repairs PVC insulated FRLS single core with stranded copper cable of size 2.5 Sqmm single core for any type of wiring as per site requirement and directed in green colour complete all as specified and as directed.
S&F in repairs PVC insulated FRLS 3 core with stranded copper cable of size 2.5 Sqmm for any type of wiring as per site requirement complete all as specified and as directed.
S&F in repairs Sub-Main wiring using single run PVC FR-LSH grade Insulated unsheathed, multistrand copper conductor cable 2 runs of 10 Sqm for phase and neutral and 1 run of 10 Sqm for earth wire drawn through concealed PVC conduit wiring in wall not less than 25mm dia with all fittings like tees, bends, junction/ terminal boxes etc as per site requirement and complete all as specified and as directed. Note:- (a) Two runs of main cable and one run of earth cable all-toghter shall be considered as one length. (b) New conduit of suitable size with connected fitting will be laid if there is a damage/blockage in existing conduit including making good to disturb surfaces with CM 1:3, same surface finished with the adjoining surface of disturbed area and the rates are inclusive of quoted rates.
S&F in repairs Sub-Main wiring using single run PVC FR-LSH grade Insulated unsheathed, multistrand copper conductor cable 2 runs of 04 Sqm for phase and neutral and 1 run of 04 Sqm for earth wire drawn through concealed PVC conduit wiring in wall not less than 20 mm dia with all fittings like tees, bends, junction/ terminal boxes etc as per site requirement and complete all as specified and as directed. Note:- (a) Two runs of main cable and one run of earth cable all-toghter shall be considered as one length. (b) New conduit of suitable size with connected fitting will be laid if there is a damage/blockage in existing conduit including making good to disturb surfaces with CM 1:3, same surface finished with the adjoining surface of disturbed area and the rates are inclusive of quoted rates.
Notes for BoQ :- The rates quoted by the tenderer shall be inclusive of the provisions as mentioned under Ser No. 1 to 6 here-in-after. The tenderer are adviced to keep in mind these provisionss while quoting his rate:-. 1. The tenderer has to bring the consumable material which loose their identity like synthetic enamel paint, OBD, cement base paint, plastic emulsion paint, Lime, exterior emulsion paint, etc well in advance along with original purchase voucher as per sample approval by as under. These material when brought by the tenderer shall be checked by BOO as detailed by GE and shall be kept in custody of concerned JE and rep of contractor with double look arrangement in store room. The material shall be issued on daily basis as per site requirement. A Pucca bond register shall be maintained by the contractor showing total quantity in hand, quantity issued and quantity incorporated in the particular quarter which shall be initiated by both the party i.e JE and rep of contractor:- (i) 25% of total reqd material as per CA provision within 10 days from the date of commencement of work. (ii) 25% of the total reqd material as per CA provision within 03 month from date of commencement of the work or earlier as per site requirement. (iii) 25% of the total reqd material as per CA provision within 06 months from the date of commencement of the work or earlier as per site requirement. (iv) Balance 25% of the reqd material as per CA provision within 02 month before the date of completion or earlier as per site requirement. (v) Engineer-in-charge/ JE shall ensure the above provision is followed before commencement of the work at site.
2. The Qtr for welcome maintenance shall be handed over to contractor as per vacation/ allotment of Qtr and users requirement. After handing over the Qtr, the tenderer has to complete the work within 07 days for normal repair and 15 days for major repair as decided by Engineer-in-Charge which includes Sunday/ holiday. Necessary panel recovery shall be made Rs. 1000 per day if the qtr not handed over within the above stipulated time after handing over of Qtr. A Pucca bond register shall be maintained at site showing Qtr No, date of vacation, date of handing over the Qtr, proposed date of completion and actual date of completion which shall be got signed by the Engr-in-Charge. 3. Every stage like preparation of surfaces, first coat, second coat/ final coat of finishes shall be got passed by Engineer-in-Charge. 4. The replaced fitting of fixture which have been replaced under this contract shall be intimated to BSO for incorporating in inventory before handing over the Qtr. 5. The contractor shall cover all the furniture item while doing painting and other repair work, clean the entire house including paint marks on joinery items, glass panes, cupboard etc with entire satisfaction of Engineer-in-Charge before handing over the key back after welcome maintenance. 6. All the above documents shall be produced for verification at the time of payment of each RAR/Bill.
Note :- The contract sum shall be after deducting the amount of Credit shown in Sch of Credit of this Tender.
A N BUILDERS
SABHARWAL CONSTRUCTION CO.
ANAND ASSOCIATES
P R Constructions
bhumica construction co.
Shivam Firetech Engineers
M/S Parmod Johar
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .