Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.1 LAccepted-AOC | L1 | Accepted-AOC Lowest tenderer | |
| 2 | L2₹23.3 L+₹3.3 L (16.3%)Rejected-Finance | L2 | Rejected-Finance Other than lowest tenderer | |
| 3 | L3₹24.2 L+₹4.1 L (20.5%)Rejected-Finance C O SECTOR 02 HOUSING COLONY CHANNI HIMMAT JAMMU J K PIN 180015 | JAMMU | JAMMU AND KASHMIR | 180015 | L3 | Rejected-Finance Other than lowest tenderer | |
| 4 | L4₹25.1 L+₹5.0 L (25.1%)Rejected-Finance | L4 | Rejected-Finance Other than lowest tenderer | |
| 5 | L5₹26.1 L+₹6.1 L (30.3%)Rejected-Finance 180 SECTOR 1 CHANNI HIMMAT CHANNI HIMMAT JAMMU JAMMU JAMMU AND KASHMIR 180015 UDYAM JK 07 0006292 | JAMMU | JAMMU AND KASHMIR | 180015 | L5 | Rejected-Finance Other than lowest tenderer |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
27 Oct 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE NAGROTA
GE NAGROTA C/O 56 APO
REPAIR/MAINTENANCE OF SECURITY LIGHTS, FLOOD LIGHTS WITH OTHER CONNECTED ITEMS AT SECTOR A,B,C,D,E,F,G,H,J AND K UNDER GE NAGROTA.
2021_MES_477754_1
GEN-46/2021-22
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE NAGROTA
Class D and above and Category b(I)
8 documents required · 8 mandatory
₹500
GE NAGROTA
₹80,000
Yes
10 Nov 2021
25 Sept 2021
29 Oct 2021
25 Sept 2021
27 Oct 2021
11 Oct 2021
60 days
Amount
Supply and fixing in replacement of automatic street light switch using Nature Switch for automatic switching of street light based on LUX level of nature light having ON ≤ 30 lux and OFF ≥ 10 Lux . The sensor (Nature Switch) along with suitable power contactor , MCB and support termianl should be enclosure made of rust proof, electric shock proof , termite proof and FR grade SMC junction box conforming to confirmining IS 13947.4-1 & IS 8828, IP 66 including contactors ( 3 Nos each) and incoming- outgoing MCBs ( 3 Nos each) rating of 25-40 amp and Circuit copper wiring of min 10 Sqmm cable incl taking down complete all as specified and directed.
S&F of 60 W LED Street Light luminaire confirmining including all necessary arrangement for fixing on Pole made up SITC of high quality integrated LED street light with a miniumum system lumen of 6600 Lm and system wattage not exceeding 90 W with nominal efficiency 110 lumen/Watt. CCT of 5700K with SDCM of <5 and CRI>70. The houing should be of non- Corrosive high -pressure die cast aluminum with heat resistant toughened clear glass to with stand extreme environments with PF>0.95. Life time of 50K Hrs @L70. The ingress protection should be minimum IP 66 with IK rating of 07. The luminaire should have 5 KV internal 10 KV external surge protection in the luminaire. Manufacturer shall have inhouse lab approved by NABL or ministry of science of govt of india. LM 79 and LM80 reports need to be submitted from NABL/UL accredited lab to verify above parameters .side entry mounted for 40 mm and above OD pipe bracket etc incl taking down old unsv light fittings complete all as specified and directed by Engr in Charge .
S&F of 90 W LED Street Light luminaire confirmining including all necessary arrangement for fixing on Pole made up SITC of high quality integrated LED street light with a miniumum system lumen of 9900 Lm and system wattage not exceeding 90 W with nominal efficiency 110 lumen/Watt. CCT of 5700K with SDCM of <5 and CRI>70. The houing should be of non- Corrosive high -pressure die cast aluminum with heat resistant toughened clear glass to with stand extreme environments with PF>0.95. Life time of 50K Hrs @L70. The ingress protection should be minimum IP 66 with IK rating of 07. The luminaire should have 5 KV internal 10 KV external surge protection in the luminaire. Manufacturer shall have inhouse lab approved by NABL or ministry of science of govt of india. LM 79 and LM80 reports need to be submitted from NABL/UL accredited lab to verify above parameters .side entry mounted for 40 mm and above OD pipe bracket etc incl taking down old unsv light fittings complete all as specified and directed by Engr in- Charge .
S&F of 120W LED Flood Light luminaire made up of Matt black ptextured powder coated pressure Die Cast aluminum housing and frame with heat resistant toughened clear glass fixed with SS screw/ Ant dust exposed lens, sturdiness and embossed brand name/ logo name of manufacturer on fixture . The luminaire should have a minimum system lumen output of 14400 lumens and 120 Watts. The fixture shall have a CRI of minimum 70. The fixture shall be designed for a sysytem life of 50000 hours @ 70 % lumen maintenence , Ingress protection of IP 66 (lamp and gear compartment ) and Mechanical impact resistance ratinfg of IK>=07. The fixture driver should have an operating voltage range of 120-277V, surge protection of internal 4 KV amd external surge protection of 10 KV, PF.0.95, THD<10%. Manufacturer shall have inhouse lab approved by NABL or ministry of science of govt of india .LM 79 and LM80 reports need to be submitted from a NABL/UL accredited lab to verify above parameters including complete electrical connection with fixing arrangenment on pole or wall and taking down unsv light fittings complete all as specified and directed by Engr-in-Charge .
S&F in replacement top Lantern of capacity 15 W energy saving , environmental friendly, long life aesthetically designed with symmetrical light distribution spun aluminium land scape luminaire with high power LEDs as light source . The luminare shall be complete IP65 for optical compartment suitable gor working for input voltage range of 140 V to 270 V Light shall have power factor more than 0.9 with THD less than 10%.having lm of 900w including complete electrical connection with fixing arrangement and taking down old unserviceable complete all as specified and directed by Eng in Charge.
Supply and fix 9 W LED bollard light fitting with opal arylic diffuser and IP 65 protection powder coated square extruded aluminium housing. Mushroom Shape Opal acrylic diffuser is fixed in die cast aluminium frames on four sides for pleasant light output with inbuilt driver with 4.5 kV surge protection.Luminaire is provided with a base plate and fixing holes for directly mounting on the concrete pedestal. LEDs mounted on top die cast aluminium housing and can be separated from base plate for easy maintenance complete all as specified and directed
Dismantling and taking down carefully flood light, street light /perimeter lighting luminaries from its position of any size/wattage from over head line poles or from elevated sentry post for carrying out repair/replacement of burnt/worn out accessories and removing unserviceable items from site and depositing to MES store yard at Nagrota, including material and labour for replacement of worn out wiring in the control gear box and accessories with PVC insulated copper conductor single core cable 1.5 sqmm size, connector block, screws etc. Refixing the fitting after repair to its position compllete all as directed by Engr-in-Charge.(Note- Accessories/components required for replacement shall be measured and paid separately under relative item of Sch 'A' )
Supply only Heavy duty copper wound ballast(choke) for HPSV/MH street light/flood light fitting of 150 watts, complete all as specified and as directed.
Supply only Heavy duty copper wound ballast(choke) for HPSV/MH street light/flood light fitting of 250 watts, complete all as specified and as directed.
Supply only Heavy duty copper wound ballast(choke) for HPSV/MH street light/flood light fitting of 400 watts, complete all as specified and as directed.
Supply only Ignitor 220-240 volts AC suitable for 150/250/400 watts HPSV street light luminaries, complete all as specified and as directed.
Supply only Capacitor 220-240 volts AC suitable for 150/250/400 watts HPSV street light luminaries, complete all as specified and as directed.
Supply only Lamp electric srew type HPSV lamps suitable for 150 watts, complete all as specified and as directed.
Supply only Lamp electric srew type HPSV lamps suitable for 250 watts, complete all as specified and as directed.
Supply only Lamp electric srew type HPSV lamps suitable for 400 watts, complete all as specified and as directed.
Supply only Electronic ballast(choke) suitable for 2x24 Watt T-5, 230V, complete all as specified and as directed.
Supply only Fluorescents tube lamps 24 W T-5 230V, complete all as specified and as directed.
Supply only Lamp LED 30 W GLO watt 230 volts, complete all as specified and as directed.
Supply only Lamp holders suitable for pin type, complete all as specified and as directed.
Supply only Lamp holders suitable for 2x24 watts Lamps, complete all as specified and as directed.
S&F Mounting arm for installation of LED light made from 40mm bore GI pipe, Medium grade, of total length 2.5 m (to be fabricated as per approved design), to be supplied alongwith mounting clamps-02 Nos, fabricated from (65mm x 5mm) MS sheet, complete all as specifed and as directed.
Supply and fixing Junction box made of SMC/FRP sheet ready made of size 300 mm x 200 x 105 mm having 100 A Capacity RYB and neutral aluminium bus bar of 3 mm thick duly fitted on suitable insulator, and MCB SP 6 A 10 KA 240V -01 No. with fixing arrangement fixed properly to pole/fixed on wall with MS Clamps 25x5 mm and nut and bolts complete all as specified and directed by the Engineer-In-Charge.
S & F junction Junction box made from SMC/FRP sheet ready made of size of 195x135x90 mm having MCB SP 6 Amp - 01 10 KA with 4 way connector fixed to pole / in wall with MS Clamp 25x5 mm and nut bolts etc.
M&L in repairs for three run single core zero halogen flame retardant insulated cable 2.5 Sqmm with unilay copper conductor and drawn through pole from junction box to street light throuh conduit pipe properly fixed with pole through clamps ,nut bolts etc , complete all as specified and directed by Engr-in-Charge.
Cleaning, preparing and painting with one coat of aluminium paint to steel tubular pole 9m/11m long complete with cross arms, MS channels, angle iron, frame work, etc including numbering of pole with black enameled paint from stencil, complete all as specified and directed.
Supply and Fixing in replacement of LED security light/Flood light fitting of 25 to 60 W capacity old burnt constant current driver, complete all as specified and directed by Eng in Charge
Supply and Fixing in replacement of LED security light/Flood light fitting of 72 to 100 W capacity old burnt constant current driver, complete all as specified and directed by Eng in Charge
Supply and Fixing in replacement of LED security light/Flood light fitting of 120 to 180 W capacity old burnt constant current driver, complete all as specified and directed by Eng in Charge
Supply and Fixing in replacement of unsv burnt surge protection device of capacity 10 kv complete suitable for security light fitting of any capacity, complete all as specified and directed by Eng in Charge
S & F in repair MCB TPN 16- 32 Amp 415 volts 50 Hz AC 10 KA 'C' series complete all as specified and directed
S & F in repair MCB SPN 6-32 Amp 415 volts 50 Hz AC 10 KA 'C' series ccomplete all as specified and directed
S & F in repair MCB SP 6-32 Amp 415 volts 50 Hz AC 10 KA 'C' series cocomplete all as specified and directed
S & F cable XLPE insulated screened PVC bedded galvanized steel striper wire armoured electric power cables heavy duty with standard aluminium conductor,1100 volts grade,cross sectional area 3.5 core 35 Sqmm , complete all as specified and directed Note : Excavation, returning and refilling will be measured and paid separately.
All as per ser item No 33 here in above but 25 Sqmm 4 core
All as per ser item No 33 here in above 16 Sqmm 4 core
All as per ser item No 33 here in above 10 Sqmm 4 core
Excavating in trenches, in any type of soil not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation, etc or not exceeding 10 Sqm on plan and not exceeding 1.5m in depth for shafts, cesspits, manholes, pier holes, etc and getting out in any type of soil complete all as specified and directed
Excavating in trenches, not exceeding 1.5m wide and exceeding 1.5m but not exceeding 3m in depth for foundation, etc or not exceeding 10 Sqm on plan and exceeding 1.5m but not exceeding 3m in depth for shafts, cesspits, manholes, pier holes, etc and getting out in any type of soil complete all as specified and directed
Returning, filling in excavated approved soil, including spreading, leveling, watering and well ramming in layers not exceeding 25cm each complete all as specified and directed
Removing excavated soil not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed
Cement concrete 1:4:8 type D-2 using 40mm graded stone aggregate in foundations, filling and mass complete all as specified and directed
Cement concrete 1:3:6 type C-2 using 40mm graded stone aggregate in foundations, filling and mass concrete complete all as specified and directed
Providing cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate in copings to poles & the like, etc including weathering, slightly rounded or chamfered angles and throating as directed including necessary form work complete all as specified and directed
Sand cushioning with fine sand to under ground cables in trenches/ducts in layers of 8 cm deep before laying the cable and 15 cm deep after laying and stretching the cable as specified in clause 19.75 of SSR Part-I, complete all as specified and directed by Engr-in-Charge..
M&L for Brick covering with width equal to length of brick as mechanical protection to cables with well burnt sub class ‘B’ (old size) bricks laid dry flat, complete all as specified and directed.
Dismantling of Concrete Poles/Struuts,any size and removing the same from site out side of MOD land complete all as specified and directed. Note:-The item are not reuse in side and carrying to credit.
Supply and fixing steel tubular pole, swaged, complete with cast iron base plate, finial taper plug, bolts, nuts, washer and screws including painting with two coats of aluminium paint over one coat of red oxide primer on all exposed surfaces and tarring with black bituminous paints to portion embedded in PCC including numbering of poles with two coats of synthetic enamel paints, type 410-SP-31 (9 meter long) complete, Including disconnecting and taking out old damage PCC pole complete all as specified and directed.
M & L for Cross arms, bracing, supports, clamps and back plate, fabricated from structural steel section including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as directed including two coats of synthetic enamel paint over a coat of red oxide primer, complete all as directed .Dismantling and taking out damage/rusted cross arms, bracings, supports, clamps and back plates from existing poles / dismantled poles / pole structures complete all as directed.
Deduction to be made from BOQ for schedule of credit (Sch 'A' Part - II) Amount of Rs. 1,16,718.00 during AOC Note:- Tenderers shall not quote for this Schedule
proach associates
MAMTA ENTERPRISES
J S ENGINEERS
Tawi Constructions
M.S Sharma Enterprises
Balbir Enterprises
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .