Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹97.6 LAccepted-AOC | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹1.0 Cr+₹1.7 L (1.66%)Rejected-Finance | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹1.2 Cr+₹16.4 L (16.5%)Rejected-Finance | L3 | Rejected-Finance Other than lowest |
| Sl No | Description | Qty | Unit | M/s Singh Engineering Corporation L3 | M/S MAKHIJA TRADERS L1 | M/S MAMTA CONSTRUCTIONS L2 |
|---|---|---|---|---|---|---|
| 1.00 | Demolition of cement concrete (unreinforced) in ground floor and pavings not exc 15 cm thick (below or above ground level) including floor tiles of any description complete all as specified & as directed. | 85 | Cum | 120 ₹10,200 | 100 ₹8,500 Lowest | 150 ₹12,750 |
| 2.00 | Demolition of brickwork or stone/boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars, etc but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and as directed. | 21 | Cum | 120 ₹2,520 | 100 ₹2,100 Lowest | 100 ₹2,100 Lowest |
| 3.00 | Taking down cement plaster or cement lime plaster, terrazo etc on PCC/stone surface/brick surfaces including raking out joints hacking for key scrubbing down with water etc, complete all as specified and as directed. | 3,875 | Sqm | 25 ₹96,875 | 20 ₹77,500 Lowest | 20 ₹77,500 Lowest |
| 4.00 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) and rubbish off the premises, complete all as specified and as directed. | 535 | Sqm | 20 ₹10,700 | 20 ₹10,700 | 15 ₹8,025 Lowest |
| 5.00 | Dismantling of stone slabs in roofs, suspended floors, chajjas, landings, etc., any description, any thickness, jointed in any mortar, complete all as specified & as directed. | 500 | Sqm | 20 ₹10,000 | 20 ₹10,000 | 15 ₹7,500 Lowest |
| 6.00 | Dismantling wall lining and ceiling boards (fibre, pulp, insulation etc) or insulation boards / slabs / blankets any thickness, including cover fillets complete all as specified and as directed. | 105 | Sqm | 20 ₹2,100 | 20 ₹2,100 | 10 ₹1,050 Lowest |
| 7.00 | M&L for brick work with old size burnt clay sub-class ‘B’ bricks, straight or curved on plan exc 6.00 metre mean radius, built in cement mortar 1:6 complete all as specified and as directed. | 15 | Cum | 4,500 ₹67,500 | 4,000 ₹60,000 Lowest | 4,000 ₹60,000 Lowest |
| 8.00 | M&L for brick work with old size burnt clay sub class 'B' bricks, straight or curved on plan to any radius in half brick thick walls built in cement mortar 1:4 complete all as specified and as directed. | 50 | Sqm | 700 ₹35,000 | 450 ₹22,500 Lowest | 450 ₹22,500 Lowest |
| 9.00 | M&L for 5cm thick sand stone slab in sunshades, chajjas, shelves, cills, landings, cover stones, templates etc not exc 2m in length, punched dressed on face and along exposed edges, self faced on the other side and set and pointed in cement mortar 1:4, complete all as specified and as directed. | 10 | Sqm | 600 ₹6,000 | 500 ₹5,000 Lowest | 600 ₹6,000 |
| 10.00 | M&L for 75mm thick PCC 1:3:6 type C2 using 40mm graded crushed stone aggregate as in plinth protection/path laid in panel surface finished even and smooth without using extra cement complete all as specified.
Note :- Plinth protection shall be of width as directed and shall be laid with an outward slope of 1:30 in alternative bays not exceeding 4 meter in length. Joints of 6 mm wide and 10 mm deep shall be provided along the wall and bays and same shall be filled with bitumen mastic (1:3). | 250 | Sqm | 225 ₹56,250 Lowest | 250 ₹62,500 | 260 ₹65,000 |
Tender Value
₹1.4 Cr
EMD Value
₹2.1 L
Closing Date
26 Dec 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE Mathura
HQ CWE Mathura, Mathura Cantt
As per tender documents
2025_MES_741869_1
8107
Open Tender
Civil Works
Item Rate
270 days
GE Bharatpur
As per NIT documents
7 documents required · 7 mandatory
₹1,000
GE Bharatpur
₹2.1 L
Yes
24 Jan 2026
28 Nov 2025
2 Jan 2026
28 Nov 2025
26 Dec 2025
19 Dec 2025
Amount
Demolition of cement concrete (unreinforced) in ground floor and pavings not exc 15 cm thick (below or above ground level) including floor tiles of any description complete all as specified & as directed.
Demolition of brickwork or stone/boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars, etc but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and as directed.
Taking down cement plaster or cement lime plaster, terrazo etc on PCC/stone surface/brick surfaces including raking out joints hacking for key scrubbing down with water etc, complete all as specified and as directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) and rubbish off the premises, complete all as specified and as directed.
Dismantling of stone slabs in roofs, suspended floors, chajjas, landings, etc., any description, any thickness, jointed in any mortar, complete all as specified & as directed.
Dismantling wall lining and ceiling boards (fibre, pulp, insulation etc) or insulation boards / slabs / blankets any thickness, including cover fillets complete all as specified and as directed.
M&L for brick work with old size burnt clay sub-class ‘B’ bricks, straight or curved on plan exc 6.00 metre mean radius, built in cement mortar 1:6 complete all as specified and as directed.
M&L for brick work with old size burnt clay sub class 'B' bricks, straight or curved on plan to any radius in half brick thick walls built in cement mortar 1:4 complete all as specified and as directed.
M&L for 5cm thick sand stone slab in sunshades, chajjas, shelves, cills, landings, cover stones, templates etc not exc 2m in length, punched dressed on face and along exposed edges, self faced on the other side and set and pointed in cement mortar 1:4, complete all as specified and as directed.
M&L for 75mm thick PCC 1:3:6 type C2 using 40mm graded crushed stone aggregate as in plinth protection/path laid in panel surface finished even and smooth without using extra cement complete all as specified. Note :- Plinth protection shall be of width as directed and shall be laid with an outward slope of 1:30 in alternative bays not exceeding 4 meter in length. Joints of 6 mm wide and 10 mm deep shall be provided along the wall and bays and same shall be filled with bitumen mastic (1:3).
M&L for 100mm thick PCC 1:4:8 type D2 using 40mm graded crushed stone aggregate as in sub floors/sub bases etc complete all as specified and as directed.
M&L for 100mm thick PCC 1:2:4 type B1 using 20mm graded crushed stone aggregate as in floor, pavings etc and finishing even and smooth (without using extra cement) complete all as specified and as directed.
M&L for non skid ceramic tiles (coloured) 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm as in floors, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles over & including 15mm thick screed bed in cement & sand mortar 1:6 complete all as specified and as directed.
M&L for non skid ceramic tiles (coloured) 7 to 8mm thick, area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm as in floors, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles over & including 15mm thick screed bed in cement & sand mortar 1:6 complete all as specified and as directed.
M&L for Vitrified Ceramic tiles 10mm thick (square/rectangular), polished, coloured (light shade & pattern as approved by GE), area of each tile not exceeding 0.36 sqm, in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles over & including 15mm thick screed bed in cement & sand mortar 1:6 complete all as specified and directed.
M&L for glazed ceramic tiles (coloured) 7mm thick, area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm (i.e 450mm x 300mm or as directed), on vertical surfaces such as dado, skirting etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles over & including 10mm thick rendering (as screed bed) in cement & sand mortar 1:4 complete all as specified and as directed.
M&L for machine cut Kota stone slab flooring 20 to 25mm thick laid over & including screed bed or bedding layer of 20mm thick in CM 1:4 and jointed with grey cement slurry mixed with pigment to match the shade of the slab with true & uniform joints including rubbing and mirror polishing complete all as specified & as directed.
M&L for machine cut Kota stone slab 20 to 25mm thick on vertical surfaces such as dado, skirting etc. laid over & including 10mm thick rendering (as screed bed) in cement & sand mortar 1:4 and jointed with grey cement slurry mixed with pigment to match the shade of the slab with true & uniform joints including rubbing and mirror polishing complete all as specified & as directed.
M&L for 20mm thick Granite (of any type) machine cut slab of approved shade (table rubbed and polished) with true & uniform joints as in steps, jambs, pillars, window cills, cooking platforms & like and pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite over & including 15mm thick screed bed (bedding layer) in CM 1:4 with cement slurry @ 3 Kg/Sqm complete all as specified & as directed. Note : The exposed edges of granite stone slab shall be made full round & polished to mirror finish and rate quoted shall deemed to include this provision.
M&L for rounding (making full moulding) to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations including making of hole suitable for gap pipe etc complete all as specified & as directed.
M&L for cutting and grinding of the existing granite/marble/kota stone flooring, skirting, dado, etc by mechanical process using Carborundum stone of appropriate grit, cleaning, making good joints with white cement slurry mixed with pigment to match the shade of the slab and finally mirror polishing by applying wax polish complete all as specified in SSR and as directed.
M&L for factory made 60mm thick machine pressed precast cement concrete coloured designer polished (reflecting type) interlocking paver blocks of Grade M-35 conforming to IS 15658-2006 of shape and size as directed with grey cement and no pigment with coloured top casted in an automatic plant working on vibration and simultaneous hydraulic compression from top, laid over & including 25mm thick sand cushioning, joints of blocks filled with dry sand and compacted with mechanical vibrator complete all as specified & as directed. Note : Shape & colour of paver blocks shall be as approved by the GE.
M&L for Providing and laying at or near ground level factory made kerb stone of size 300x300x150mm, M-25 graded cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement : 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete all as specified & as directed.
S&F Pre-painted galvalume aluminium zinc coating corrugated steel sheet 0.50mm thick with coating AZ-150 gsm of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified & as directed. Note : Colour of sheet shall be as approved by the GE.
S&F Gl frame work for seamless ceiling comprising of Gl perimeter channnel 0.55 mm thick with two unequal flanges of 20 and 30mm and web of 27mm fixed to surrounding wall using nylon sleeves and screws at 450mm centre to centre/intermediate channel 0.90mm thick having two equal flanges of 15mm each and web of 45mm suspended from soffit at approx 900mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.20m length) of 0.55mm thickness having kurled web of 50mm and flange of 26mm each with lips of 10.5mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457mm centre to centre complete all as specified & as directed.
S&F for Hangers 6mm dia GI (upto 1200mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flat 40 x 3mm size 60mm long and expansion hold fasteners 12.5mm dia 40mm long complete all as specified and directed.
M&L for false ceiling with 4mm thick non-asbestos fibre cement building boards fixed including anodized aluminium frame work complete all as per manufacturer’s instructions, all as specified and as directed.
S&F mild steel rolled sections as in roof trusses (framed), trussed, purlins, crane gantries rails and fastenings and havy bracket framing (beam, tee, angle, channel or flat section & MS pipe) including distance pieces, connected to common rafters and running rails and guides for sliding doors, fixed with angle cleats or other connecting plates etc. conforming to Fe-410, grade E-250 quality `A’ complete all as specified and directed.
S&F mild steel work as in hand rails, half round or other stock section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts, posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc., flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Grade E-165 (Fe 290), complete, all as specified & directed.
S&F mild steel framed work such as grills, gratings, etc with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, framed signed boards, walk ways, railings, framework of water tanks and similar work including welding conforming to Grade E-165 (Fe 290), complete all as specified & as directed.
S&F hard drawn steel wire fabric, weight not exc 4 Kg per sqm, cut to lengths, bent to shape required and tying with and including mild steel wire (annealed) not less than 0.9mm in dia, supplied and fixed complete all as specified & as directed.
S&F window guard bars, plain and fixed independently in steel window frames, etc conforming to Fe 290 Gde E-165, complete all as specified and as directed.
S&F 1mm thick mild steel, plain, black sheet in wall cladding, steel gates and similar work, cut to size, holes punched; including round headed screws, clout nails or rivets or welded and fixed to steel framing with plain 40mm lap joints with riveted or welded seams, including bending or turning upmitred angles etc as required complete all as specified and as directed.
M&L for galvanized steel water tubing medium grade of 15mm bore with & including all fittings complete, fixed to walls and ceilings or laid in floors including taking up or down old unserviceable steel water tubing and connections of 15mm bore, complete all as specified and directed.
M&L for galvanized steel water tubing medium grade of 20mm bore with & including all fittings complete, fixed to walls and ceilings or laid in floors including taking up or down old unserviceable steel water tubing and connections of 20mm bore, complete all as specified and directed.
S&F in repair vitreous china squatting pan (Orissa pattern) water closet (white) of size 580x440mm with integral foot rests, ‘P’ or ‘S’ trap, including connection to trap and flushing pipe, antisyphonage pipe etc, complete all as specified and as directed.
S&F in replacement of vitreous china wash hand basin, white, flat back of size 550mm x 400mm with & including a pair of cast iron brackets embedded in PCC 1:3:6 type C1 blocks of size 10x7.5x15cm, 32 mm dia PVC waste pipe and 32mm bore chromium plated brass waste fitting with long screwed shanks and fly nuts, flange end bedded in red lead cement & other end fixed, (excluding tap, waste chain & plug), complete all as specified & as directed.
S&F in repairs PVC valveless symphonic action type low level flushing cistern (ISI marked) of 10 litre capacity including 32 mm dia PVC flush pipe connected to water closet with inlet, ball valve, float and handle complete all as specified & as directed.
S&F PVC connection 450 mm long suitable for 15 mm bore GI pipe including PTMT nuts on both sides complete all as specified & as directed.
S&F in repairs 15mm bore pillar tap, cast copper alloy with capstan heads, chromium plated, fancy type, screwed down high pressure, with or without lettered ‘Hot’ or ‘Cold’ with long screwed shanks & fly nuts, screwed for iron pipes, complete all as specified & as directed.
S&F in repairs 15mm bore bib tap, cast copper alloy, chromium plated, long body, fancy type with capstan head, screwed down, screwed for iron pipe or for brass ferrule complete all as specified & as directed.
S&F in repairs 15mm bore Stop valve, cast copper alloy, fancy type chromium plated, screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for union complete all as specified & as directed.
S&F in repairs 15mm bore Stop valve, cast copper alloy, fancy type chromium plated with long shank and cup (concealed type), screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for union complete all as specified & as directed.
S&F in repairs 20mm bore Stop valve, cast copper alloy, fancy type chromium plated, screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for union complete all as specified & as directed.
S&F in repair chromium plated shower rose 125mm size with 200mm long CP shower arm with swivel joints including fixing to steel pipe of 15mm bore or union complete all as specified and as directed.
S&F in repairs tubular towel rail, brass chromium plated, 20mm dia, ‘D’ type, 60cm long between flanges, fixed to PVC rawl plugs with chromium plated brass screws, complete all as specified and as directed.
S&F in repairs waste coupling of PTMT (half or full threaded) suitable for WHB/Sink, bore dia of discharge pipe 40mm (Minimum weight 60gms) complete all as specified and as directed.
S&F in repairs mild steel chromium plated tubular curtain/drapery rod 20mm dia (in lengths as directed) with & including pair of projecting type fancy mild steel chromium plated brackets fixed at both ends with PVC rawl plug & steel screws on walls/beam complete all as specified & as directed.
S&F in repair Sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long complete all as specified and directed.
Disconnecting & taking down the existing unserviceable water tank and supply and fixing 500 Litre capacity Rotational moulded polyethylene water storage tanks double layered (cylindrical vertical with closed top) ISI marked, hoisted & fixed in position & making necessary arrangements for fixing inlet, outlet & over flow pipe & provision of wash out pipe etc. complete as specified in SSR Part-I and as directed. Note : (i) The water storage tanks shall be 2 layers, HDPE tanks moulded to seem-less perfection of rotational process. The tank shall be manufactured only from FDA approved special grade of polyethylene and shall be certified fit for potable water. (ii) The tanks shall white coloured and ISI marked. Also refer paras 18.6 and 18.6A of MES Schedule Part-I. (iii) Payment for inlet, outlet and over flow pipes and ball valve shall be made separately. Howerver cost of providing necessary GI fittings such as nipples with check nuts for inlet and outlet pipes, GI plug with check nut for over flow pipe and 30cm long wash out pipe, GI 20mm nominal bore, medium grade and check nut for wash out pipes of size as per actual requirements as directed by Engineer-in-Charge shall be deemed to be included in the unit rates of this item.
Supply and fixing PTMT ball valve of 20mm bore high pressure of PTMT with epoxy coated aluminium rod & high denisty plastic ball screwed for iron pipe (minimum weight -210 grams) complete all as specified and as directed.
Taking down chowkats or frames n. exc 1.5 sqm each with shutters (without taking off shutters from the frame) complete all as specified and as directed.
Taking down chowkats or frames exc 1.5 sqm but n exc 4 sqm each with shutters (without taking off shutters from the frame) complete all as specified and as directed.
S&F Plain, framed, panelled shutters 40mm thickness (any number of panels), with panels of timber flat on both sides (feather edged), or of veneered particle board medium density, wood particle board with commercial face veneers, supplied and fitted to chowkats, complete all as specified and directed.
S&F factory made, 35mm thick, 2nd class hardwood glazed and skeleton shutters, open rebated and prepared to receive glass, gauge etc. (without sash bars), edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass, gauge etc., sizes of members of shutters as specified 8.24(a) in SSR Part I complete as as specified and as directed.
S&F for Solid PVC Door Frame of the size 50x47mm made out of 5 mm PVC sheet. The door profiles are to be reinforced with 19x19mm M.S Square tube. The profile shall be cut and mitred at two corners and joined by inserting 2 Nos of 150mm long brackets of 15x15mm M.S. square tube inside the 19mm x 19mm M.S. square tube and suitably screwed complete all as specified and as directed.
S&F factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of MS tubes for top & bottom rails. MS frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded/sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement all as specified & shown on SSR 2020 (Part-II) complete all as specified and as directed.
S&F Factory made uPVC white colour Sliding window, three track made of extruded profiles with wall thickness of 2.3mm (+/- 0.2 mm). area n exc 2 sqm each window profile with hollow section with multi chamber, Frame (88mm x 52mm), sliding sash (42mm x 67mm), Sliding mesh Sash (42mm x 57mm), Sliding interlock (One vertical length in each shutters) (45.5mm x 28mm), Glazing bead (24.5mm x 16mm) will be miterd cut and fusion welded at all corners, including drilling of holes for fixing hardware and drainage of water etc., making arrangement for fixing of hardware. EPDM gasket, 1.2+/- 0.2 mm thick galvanised steel Frame (30mm x 18mm) 2 nos, sliding sash (30mm x 18mm), sliding mesh sash (26mm x 10mm) profile to be inserted in required profile, frame will be fixed to the wall with 8mm x 100mm long fasteners complete all as specified and directed. Hardware : Touch Lock of zinc alloyed (white powder coated), steel roller system. Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and required accessories. Note : The Unit rate quoted by contractor include cost of glass and includes all other connected accessories.
M&L for 18mm thick PVC boarding shutters of density exc 550 Kg per Cum but nexc 600 Kg per Cum one side decorative lamination & other sidebalancing lamination sheet fixed with brackets, screws etc, Panels shall be fabricated using adhesive and screws wherever required all the edges shall be coverd with 18mm x 1mm thick edge bending tape or 90 degree edge bend finish as per manufactrure specification or approved pattern complete all as specified and as directed.
M&L for 18 mm thick PVC boarding shelves of density exc 550 Kg per Cum but nexc 600 Kg per Cum one side decorative lamination & other sidebalancing lamination sheet fixed with brackets, screws etc, Panels shall be fabricated using adhesive and screws wherever required, Supported for three sides with 18 mm x 18 mm PVC Ply fixed with Screw all the edges shall be coverd with 18 mm x 1 mm thick edge bending tape or 90 degree edge bend finish as per manufactrure specification or approved pattern complete all as specified and as directed.
S&F Continuous (piano) hinges, mild steel, bright finish or electrogalvanised with width of flaps (When open) 40mm complete all as specified and as directed.
S&F for stainless steel 125mm handle not less than 12mm dia suitable for cupboard shutters with self tapping stainless steel screw complete all as specified and as directed.
S&F 125mm Butt hinges, heavy weight, cold rolled mild steel (ISI marked) complete all as specified and as directed.
S&F 100mm Butt hinges, medium weight, cold rolled mild steel (ISI marked) complete all as specified and as directed.
S&F 100mm Butt hinges stainless steel (ISI marked) complete all as specified and as directed.
S&F 125mm long aluminium anodized barrel tower bolts of extruded section (ISI marked) fixed complete all as specified and as directed.
S&F 200mm long aluminium anodized barrel tower bolts of extruded section (ISI marked) fixed complete all as specified and as directed.
S&F 125mm aluminium handle, cast type, anodised, complete all as specified & as directed.
S&F 250mm long aluminium alloy, anodized, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy complete all as specified and as directed.
S&F Magnet catch for shutters as per approved sample complete all as specified and directed.
M&L for preparation of old painted surfaces of wood and wood based material of any description over 10 cm in width or girth and applying one coat of synthetic enamel paint of approved tint all as specified & as directed.
M&L for preparation of new surfaces of wood or wood based materials of any description over 10 cm width or girth and applying two coats of synthetic enamel paint of approved tint over a coat of pink primer complete all as specified & as directed.
M&L for preparation of old painted steel and iron surfaces of any description over 10 cm in width or girth and applying one coat of synthetic enamel paint of approved tint all as specified & as directed.
M&L for preparation of new steel and iron surfaces of any description over 10 cm in width or girth and applying two coats of synthetic enamel paint of approved tint over a coat of zinc chrome primer complete all as specified & as directed.
M&L for rendering 10mm thick in cement and sand mortar 1:6 on fair faces of brick masonry or concrete surfaces of walls, finished even & smooth without using extra cement complete all as specified and as directed.
M&L for rendering 10mm thick in cement and sand mortar 1:4 on fair faces of brick masonry or concrete surfaces of walls, finished even & smooth without using extra cement complete all as specified and as directed.
M&L for rendering 15mm thick in cement and sand mortar 1:4 on other than fair faces of brick masonry or concrete surfaces of walls, mixed with integral liquid water proofing compound as per manufacturer’s instructions, finished even & smooth without using extra cement, complete all as specified and as directed. Note : Supply only integral liquid water proofing compound shall be measured and paid for separately.
M&L for rendering 15mm thick in cement and sand mortar 1:4 on other than fair faces of brick masonry or concrete surfaces of walls, finished even & smooth without using extra cement, complete all as specified and as directed.
M&L for rendering 5mm thick in cement and sand mortar 1:3 on concrete surfaces in ceiling, finished even & smooth without using extra cement complete all as specified.
Supply only integral water proofing compound (ISI marked) complete all as specified & as directed.
S&F galvanized mild steel wire cloth 0.56 mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks or galvanized wire staple complete all as specified & as directed.
S&F in replacement of galvanized mild steel wire cloth 0.56 mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks or galvanized wire staple complete all as specified & as directed.
S&F in replacement of 3mm thick sheet glass ordinary quality and glazing with oil putty in square not exc 0.5 sqm in each pane including painting / oiling to new putty to match with the existing/new surfaces, complete all as specified & as directed.
S&F Sheet glass 4mm thick, ordinary quality & glazing with oil putty in squares n.exc 0.5 sqm in each pane including punching or drilling out old glazing pins/spring clips, and providing & fixing new ones complete all as specified and as directed.
M&L for preparation of newly plastered / unplastered surfaces of ceilings and applying three coats of white wash complete all as specified and directed.
M&L for preparation of old surfaces (plastered or unplastered) of ceilings including brooming or steel wire brushing, scrapping down smoke soot, moulds, moss, efflorescent salts, trading oil, greasy spots and applying one coat of white wash complete all as specified & as directed.
M&L for complete removal of existing treatment on ceiling including washing rubbing down and stopping of distempered and painted surface and preparation old surface and applying two coats of white wash including preparation complete complete all as specified & as directed.
M&L for preparation of newly plastered or un plastered surfaces of walls and applying two coats of oil emulsion distemper white or tinted over 1mm thick wall care putty on Wall Surface including all necessary arrangement for execution of work, complete all as specified and as directed.
M&L for preparation of old decorative concrete, plastered surface of wall including cornices, pilasters etc by brooming down, steel wire brushing, scraping down smoke soot, moulds, moss and efflorescent salts and treating oil and greasy spots removing nails and filling small holes by putty and preparation of surface & applying one coat of exterior emulsion paint for external wall surface complete all as specified and as directed.
M&L for preparation of newly plastered or un plastered surfaces of walls and applying two coats of oil emulsion distemper white or tinted over 1mm thick wall care putty on Wall Surface including all necessary arrangement for execution of work, complete all as specified and as directed.
M&L for preparation of new plastered or Gunited surfaces and applying thoroughly wetted surface to ensure better sticking including sand paper gentle rubbing to obtain smooth surfaces, including all necessary arrangement for execution of work and applying two coats of exterior weather proof paint (APEX) in camouflaging pattern with roller application over one coat of water based white pigmented akali resistant priming paint for external wall, complete all as specified and directed.
M&L for complete removal of existing treatment on walls including washing rubbing down and stopping of distempered and painted surface and preparation of old surface applying thoroughly wetted surface to ensure better sticking including sand paper gentle rubbing to obtain smooth surfaces, including all necessary arrangement for execution of work and applying two coats of exterior weather proof paint (APEX) in camouflaging pattern with roller application over one coat of water based white pigmented akali resistant priming paint for external wall over 1mm thick white external wall cement putty complete all as specified and directed.
M&L for preparation of new plastered or Gunited surface and applying two coat of distemper oil emulsion over one coat of water based white pigmented alkali resistant primer paint over 1mm thick internal wall care putty conforming to IS : 109-1968 white or tinted on ceiling & walls complete all as specified and as directed.
M&L for complete removal of existing treatment on walls including washing rubbing down and stopping of distempered and painted surface and preparing old surface and applying two coats of oil bound distemper over 1mm thick internal wall care putty including preparation by rubbing complete with roller application complete all as specified and directed.
M&L for preparation of old distempered surface of wall including cornices etc by brooming down, steel wire brushing, scraping down smoke soot, moulds, moss and efflorescent salts and treating oil and greasy spots removing nails and filling small holes by wall care putty and applying one coat of distemper oil emulsion white or tinted complete all as specified and as directed.
M&L for cutting or uprooting grass including removing old mud phuska/ roof treatment of 100mm thickness and description, removing rubbish off the premises, cleaning surface and preparation to receive new treatment complete all as specified and directed.
M&L for 40mm thick PCC 1:2:4 type B-1 (using 20mm graded stone aggregate) as in sub base of roof/floor complete all as specified and as directed.
M&L for preparing surfaces for roof treatment by removing all loose gravel, dirt, oil, grease and foreign matter by jet of dry air and clean the surfaces mechanically or by grinding to make it smooth before application, repair all cracks by cutting V groove and fill with PMC mortar (Polymer Modified Cement Mortar) prepared in ratio as per manufacturers specification provide 75mm x 75mm coving made out of PMC mortar as above on all joints of vertical upstand to ensure that moisture content in the prepared surfaces does not exceed 5% immediately before application of liquid membrane. Material incorporation & PROTECTION BE PROVIDED AS TERRASHEILD FIRST APPLY WITH WATER (RATIO TERRASHEILD : WATER will be 4 : 1) as primer with coverage area 0.10 Kg per Sqm. After 2-3 hours later, second step apply directly first coat of terrasheild 0.30 to 0.40mm thickness coverage area 0.50 to 0.75 Kg per Sqm with roller. spread non woven geo textile of 40/50gsm with overlap of 50mm in both direction when the surface is still tacky. After 4-6 hours later, apply third step apply directly second coat of terrasheild 0.30 to 0.40mm thickness coverage area 0.50 to 0.75 Kg per Sqm with roller. Final thickness of complete treatment should be min 1.0mm. water tank and khurra location one additional coat of terasheild 0.30 to 0.40mm thickness coverage area 0.50 to 0.75 Kg per Sqm be provided. after complete application will be done authorised applicator from manufacturer and manufacturer's applicatiuon complete all as specified and directed. Make : IWL/STP/Piddilite/Sika/Fosroc
M&L for removal of existing treatment by taking out loose/spalled out waste material by chiselling chippings etc from beam, wall, columns, band, ceiling etc. including use and waste of formwork and providing steel wire fabric mesh of size 75mm x 75mm of dia 3.15mm fixed by L shaped mild steel shear key welded with existing reinforcement and providing 40mm average thickness concrete (1:1.5:3) type A-0 using graded stone aggregate of 10mm maximum size mixed with polymeric admixture with pressure nozzle (guniting) and finishing the surface in CM (1:3) surface finished even and smooth without using extra cement and removing the debris outside MD land complete all as specified and directed. Note : Quoted rates shall deemed to be inclusive of all formwork and scaffolding or other handy T&P required to make up proper shape and size of columns/ Pillars, beam and wall partition etc.
M&L for APP (Atactic Polypropylene polymer) modified prefabricated five layer 4mm thick water proofing membrane,black finished reinforces with nonwoven polyester matt consisting of a coat of bitumen primer of bitumen membrane @ 0.40 litre/sqm by the same membrane manufacturer of density at 25 degree C 0.87-0.89 Kg/litre and viscosity 70--160cps.Over the primer coat the layer of membrane shall be laid using Butane torch and seiling all joints etc and preparing the surface complete. The vitalphysical and chemical parameters of the membarane shall be as under: Joint strength in longitudinal and transvrese direction at 23 degree C as 650/450N/5cm. Tear strength in longitudinal and transverse direction as 300/250N. Softening point of membarane not less than 150 degree C. Cold flexibility shall be upto -2 degree C when tested in accordance with ASTM, D complete all as specified and directed.
M&L for 20mm thick screed bed or bedding layer of cement and sand mortar (1: 4) finished even and smooth without using extra cement complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of PVC (SWR) pipe not less than 6 Kgf/sqcm rating single socketed, in any length with rubber ring joints including clamps of FI 40x3mm fixed bolt 8mm drilled to walls for fixing, type 'B' ISI marked of 110mm bore complete all as specified and as directed.
S&F in replacement of PVC (SWR) pipe not less than 6 Kgf/sqcm rating single socketed, in any length with rubber ring joints including clamps of FI 40x3mm fixed bolt 8mm drilled to walls for fixing, type 'B' ISI marked of 75mm bore complete all as specified and as directed.
S&F 110mm bore PVC (SWR) bends any radius provided with access door complete all as specified and directed.
S&F 75mm bore PVC (SWR) bends any radius provided with access door complete all as specified and directed.
S&F 110mm bore PVC (SWR) single junction (Single 'T') equal or un equal complete all as specified and as directed.
S&F 75mm bore PVC (SWR) single junction (Single 'T') equal or un equal complete all as specified and as directed.
S&F in repair PVC (SWR) floor trap 75mm dia plain with stainless steel grating including jointing with solvent cement complete all as specified and directed.
S&F PVC (SWR) Vent cowl of 75mm bore complete all as specified and as directed.
Taking down existing steel rolling shutters of size not exceeding 3.20m x 4.00 m complete all as specified and directed.
Supply and fixing ball bearing for rolling shutters complete all as specified and as directed.
Supply and fixing safety lever locks mild steel with 4 levers for rolling shutters complete all as specified and as directed.
S&F 1.25mm thick Steel rolling shutters, without ball bearing, as specified including top cover, side guides, anchoring rod, hasp and staple, lock plate of length not less than 2.20m and not more than 4.00m and width not less than 0.15m and not more than 0.20m of riveted construction made out of mild steel sheet 3.15mm thick, reinforced with mild steel angle 35x35x5mm size at bottom and locking arrangement with two 50mm bow handles and flat iron 25x3mm to fix the lath and lock plate, guide channel made out of 2mm thick MS sheet size 75x30mm including taking down the existing guide channel from rolling and fixing with wall/column etc and making good with PCC (1:2:4) type B-1 and cement work (1:3) and one shop coat of primer erected in position as indicated and specified in SSR Part-I complete push pull or manual type complete all as specified and directed.
S&F in repair sinks made of stainless steel lmm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar on to dwarf wall or includingfixing cantilever brackets and connecting union to pipe, overall size 495mm x 420mm bowl size 410mm x 330mm x 160mm including waste pipe of polythelene of low or high density including making holes in any type of wall for brackets and fixed in CM 1:3 or PCC 1:2:4 type B0 complete all as specified and as directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for, complete all as specified and as directed.
M&L for point wiring for one light/fan/bell/buzzer point controlled by one, one way switch with 1.50 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLSH cable 1100 Volt grade (ISI marked) including 1.50 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLSH cable 1100 Volt grade (ISI marked) as continuous earth wire in green colour to common earth and connected to earth dolly laid/drawn into and including non-metallic rigid PVC concealed conduit (medium duty, ISI marked, not less than 20mm dia) with all fittings such as tee, bends, etc all as per IS, terminated in & including new sunk type pressed steel terminal boxes concealed in wall for mounting fittings like switches, sockets, regulators etc with and including 3mm thick phenolic laminated sheet top cover, including taking down old point wiring complete all as specified and as directed. Note : Cost of cutting/leaving forming chases for conduits, sinking for boxes and making good in CM 1:4 shall deemed to be included in quoted rate of this item.
All as per serial item No. 117.00 here-in-before but for one 3 pin 5/6 Amp socket outlet controlled by one 5 Amp switch on same board with other switches complete all as specified and directed.
All as per serial item No. 117.00 here-in-before but for one 3 pin 5/6 Amp socket outlet controlled by one 5 Amp switch on independent board complete all as specified and directed.
All as per serial item No. 117.00 here-in-before but for one 3 pin 15/16 Amps socket outlet controlled by one 15/16 Amps switch on independent board with 2.5 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLSH cable 1100 Volt grade (ISI marked) including 2.5 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLSH cable 1100 Volt grade (ISI marked) as continuous earth wire in green colour complete all as specified and directed.
S&F switch piano, flush type, single pole, one way, 5/6 Amp, 230 Volts, ISI marked, complete all as specified and as directed.
S&F switch piano, flush type, single pole, one way, 15/16 Amp, 230 Volts, ISI marked, complete all as specified and as directed.
S&F socket outlet, 5 pin, 15/16 Amp, flush type, 230 Volts, ISI marked, complete all as specified and as directed.
S&F socket outlet, 2 in 1, 5 pin, 5 and 15/16 Amp, flush type, 230 Volts, ISI marked, complete all as specified and as directed.
S&F ceiling rose, PVC/Polycarbonate insulated body, 65mmx50mm with three terminals, ISI marked, complete all as specified and as directed.
S&F lamp holder, PVC/Polycarbonate insulated body with back plate suitable for conduit/casing caping fittings, ISI marked, complete all as specified and as directed.
S&F electronic fan regulator, flush type, stepped type with 5 step control, 230 Volts, 150 Watt, including making hole in sheet top cover and connecting up, ISI marked, complete all as specified and as directed.
M&L for sub main wiring with two runs of 4 sqmm (nominal area) size main cable & one run of 4 sqmm size earth continuity conductor, single core, PVC insulated, unsheathed, FRLSH with multi-stranded copper conductor, 1100 Volts grade, ISI marked cables, drawn through & including suitable size of heavy duty non-metallic rigid PVC concealed conduit ISI marked not less than 20mm dia & conduit fittings/accessories, fixed concealed in wall/ceiling including dismantling & taking down old unserviceable sub main wiring complete all as specified and directed. Notes : (i) 02 runs of 4 sqmm size main cable, 01 run of 4 sqmm size earth continuity conductor cable & conduit with accessories shall be measured as one run length for payment purpose. (ii) Cost of cutting/leaving forming chases for conduits and making good in CM 1:4 shall deemed to be included in quoted rate of this item.
M&L for sub main wiring with two runs of 6 sqmm (nominal area) size main cable & one run of 6 sqmm size earth continuity conductor, single core, PVC insulated, unsheathed, FRLSH with multi-stranded copper conductor, 1100 Volts grade, ISI marked cables, drawn through & including suitable size of heavy duty non-metallic rigid PVC concealed conduit ISI marked not less than 20mm dia & conduit fittings/accessories, fixed concealed in wall/ceiling including dismantling & taking down old unserviceable sub main wiring complete all as specified and directed. Notes : (i) 02 runs of 6 sqmm size main cable, 01 run of 6 sqmm size earth continuity conductor cable & conduit with accessories shall be measured as one run length for payment purpose. (ii) Cost of cutting/leaving forming chases for conduits and making good in CM 1:4 shall deemed to be included in quoted rate of this item.
M&L for sub main wiring with two runs of 10 sqmm (nominal area) size main cable & one run of 10 sqmm size earth continuity conductor, single core, PVC insulated, unsheathed, FRLSH with multi-stranded copper conductor, 1100 Volts grade, ISI marked cables, drawn through & including suitable size of heavy duty non-metallic rigid PVC concealed conduit ISI marked not less than 20mm dia & conduit fittings/accessories, fixed concealed in wall/ceiling including dismantling & taking down old unserviceable sub main wiring complete all as specified and directed. Notes : (i) 02 runs of 10 sqmm size main cable, 01 run of 10 sqmm size earth continuity conductor cable & conduit with accessories shall be measured as one run length for payment purpose. (ii) Cost of cutting/leaving forming chases for conduits and making good in CM 1:4 shall deemed to be included in quoted rate of this item.
S&F sheet metal enclosure for distribution boards flushed in wall, double door type, suitable for fixing MCBs/MCCBs, 415 Volts with 200 Amps rated bus bar, load line DB fitted with bus bar neutral links blank plates, TPN, 4 way, suitable for frame MCB, fitted complete all as specified and as directed including taking down old existing unserviceable DB with fixtures of any type & capacity. Note : Cost of cutting/leaving forming chases for sinking for DB and making good in CM 1:4 shall deemed to be included in quoted rate of this item.
S&F sheet metal enclosure for distribution boards flushed and surface mounting, double door type (IP-43 IK 09 with metal door), suitable for fixing MCBs, 240 Volts with 200 Amps rated bus bar, with neutral bar, earth bar and cables ties for cable management fully insulated bus bar, DB fitted with bus bar neutral links blank plates, SPN, 8 way, suitable for MCBs, fitted with and accessories, including taking down old existing unserviceable DB with fixtures of any type complete all as specified and as directed. Note : Cost of cutting/leaving forming chases for sinking for DB and making good in CM 1:4 shall deemed to be included in quoted rate of this item.
S&F sheet metal enclosure for distribution boards flushed and surface mounting, double door type (IP-43 IK 09 with metal door), suitable for fixing MCBs, 240 Volts with 200 Amps rated bus bar, with neutral bar, earth bar and cables ties for cable management fully insulated bus bar, DB fitted with bus bar neutral links blank plates, SPN, 4 way, suitable for MCBs, fitted with and accessories, including taking down old existing unserviceable DB with fixtures of any type complete all as specified and as directed. Note : Cost of cutting/leaving forming chases for sinking for DB and making good in CM 1:4 shall deemed to be included in quoted rate of this item.
S&F in replacement of MCB, 6 to 32 Amps, Single Pole (SP), 240 Volts, rupturing capacity not less than 10 kA, ‘C’ Curve, with over load and short circuit protection, complete all as specified and as directed.
S&F in replacement of MCB, 40 to 63 Amps, Single Pole Neutral (SPN), 240 Volts, rupturing capacity not less than 10 kA, ‘C’ Curve, with over load and short circuit protection, complete all as specified and as directed.
S&F in replacement of MCB, 40 Amps, Triple Pole Neutral (TPN), 415 Volts, rupturing capacity not less than 10 kA, ‘C’ Curve, with over load and short circuit protection, complete all as specified and as directed.
Supply and fixing in replacement of LED tube light fitting, 18/20 Watt, 230 Volts, retro fit type 4 feet long with replacable rod complete with all accessories and including connecting up with including three core twisted flexible copper cable with suitable size complete all as specified and as directed.
Supply and fixing in replacement of LED tube light fitting, 20 Watt, 230 Volts, sensor based batten type 4 feet long with rod complete with all accessories and including connecting up with including three core twisted flexible copper cable with suitable size complete all as specified and as directed.
Supply and fixing in replacement LED mirror light fitting with high out put with low energy consumption of capacity 6 Watt, waterproof moisture anti fog anti corrosion anti rust curved LED off white including connection up with three core flexible copper cable conductor cable of suitable size complete all as specified and as directed
Supply and fixing in replacement bracket light fitting wall mounting champagne gold finish fixture with plastic body suitable for 14 Watt LED lamp B22 base complete all as specified and as directed
Supply and Fixing Light Emitting Diode (LED) based street/ security light fitting, 35 Watt with & including LED lamp, housing made up of LM6 pressure die cast aluminium alloy with effective thermal management, sturdiness, monolithic construction, totally enclosed, dust and water proof, minimum system efficiency of more than 100 lumens per watt and a minimum system lumen output of not less than 3000 lumens, correlated colour temperature shall be minimum 5700 degree Kelvin, Colour Rendering Index (CRI) shall not be less than 70, fitting shall be designed for a system life of 50,000 hours @ 70% lumen maintenance, ingress protection of IP-65 (minimum), mechanical impact resistance rating of IK ≥ 07, operating voltage range 140 V to 270 V, AC, frequency 50-60Hz, potted type for humming free operation, driver shall withstand upto 400 V for 08 hours, surge protection not less than 10 KV, Power factor > 0.95, Total Harmonic Distortion (THD) shall be less than 15%, double phase protection, no load, open circuit and short circuit protection, suitable for ambient temperature from (-)10°C to 50°C and humidity level 10% to 90% RH, cool white colour and lamp starting time shall not be more than 10 second, PMMA /polycarbonate /toughened glass heat resistant cover, prewired and connecting up to street light feeder/junction box with & including 2.5 Sqmm 3 core PVC insulated, weather proof, multi stranded copper conductor cable of 1100 Volt grade (ISI marked), fixed including dismantling & taking down old unserviceable LED street/security light complete all as specified and as directed.
S&F in replacement mounting bracket (suitable for fixing/holding street/security light fittings) made of 40mm bore GI pipe ‘light grade’ not less than 0.60m long, bent to shape of 120 degree end welded at required, fixed to Pole/wall with & including mild steel clamps (02 Nos) made out of flat iron 40x6mm with nuts, bolts & washers, matching with section of Pole/suitable for wall, complete all as specified and as directed.
S&F LED recessed full fit luminaire with glare free uniform illumination 2 ft x 2 ft, 35/36 Watt complete with all accessories internally pre-wired and including connecting to ceiling rose with three core flexible copper conductor cable of suitable size including dismantling & taking down old unserviceable light complete all as specified and as directed.
Sypply and fixing metal enclosure of single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amp, 230 Volt, 10 kA, ‘C’ Curve, complete all as specified and as directed.
Supply & fixing Exhaust fan of 300mm sweep, heavy duty, double ball bearing, copper wound, steel body, 900 RPM, Single Phase 230 Volt, 50 Hz AC supply complete with blades, frame and louver shutter and connecting up with & including three core PVC insulated PVC sheathed copper conductor flexible cable 24/0.2 mm drawn into & including flexible PVC conduit and fixed by using 4 Nos, 100mm long 8mm dia bolt nuts and washers and grouted in wall in CM (1:3) with and including making suitable opening in existing wall complete all as specified & as directed
Supply and fixing Exhaust Fan made of sturdy Engineering plastic complete with louvers shutter, 250mm sweep, 230V, 50 Hz, 1200 RPM, Copper winding and connecting with & including 1 Sqmm, three core, flexible multistranded copper conductor cable and connected from ceiling rose to fan complete all as specified & as directed.
Material and labour for cutting suitable holes in existing masonry wall and fixing suitable size hume pipe for fixing of exhaust fan 250/300 mm dia and making good disturbed sufaces with cement mortar (1:4) and finished to match existing surface complete all as specified and directed.
Supply, assembling, hanging, fixing & testing Ceiling Fan of size 1200 mm sweep, minimum air delivery 210 CMM with service value 6.00 BEE, 5 star rated, with brushless direct current (BLDC) motor, single phase, AC supply, 230 Volt, with & including down rod, canopies, three number blades, capacitor 2.5 mfd, hook, rubber reel, safety pins, nuts, bolts, washers, cable connector and making connection with PVC insulated & sheathed 1 Sqmm three core flexible copper multistranded conductor cable (ISI marked) from ceiling rose to connector of ceiling fan including marking of SM / MES number with thick synthetic enamel paint of approved tint complete all as specified and as directed. Note :- The font, style & place of writing SM/ MES number with synthetic enamel paint on ceiling fan shall be as directed by the Engineer-in-Charge and cost thereof shall deemed to be included in quoted rates.
M&L for earthing complete with galvanized steel earth plate electrode 60cmx60cmx6mm thick burried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of plate not less than 1.5 m deep below normal ground level and connected to and including galvanized iron earth wire 4mm dia by means of GI nuts, bolts, check nuts, washers thimbles, etc as shown in electrical plate No 3 of SSR Part-I and connection to main switch board/Test point/panel/equipment and testing on completion including excavation and earth work in any type of soil, returning filling in and removal of surplus spoil to a distance not exc 50 metre, charcoal and salt in alternate layer 15 cm thick all around the earth plate electrode, MS funnel with wire mesh, GI pipe medium grade 20 mm bore for watering and 15 mm bore 7.50 metre long GI pipe light grade for earth wire protection fixed with poles with two clamps, made from MS flat 25 mmx3mm, bolts, nuts and washers, PCC chamber (1:3:6) type C1, 40mm thick RCC pit cover, etc including dismantling & taking out old existing unserviceable earthing complete all as specified & as directed. Note : (i) PCC chamber shall be constructed at least 1.5 mtr away from the earth electrode and pipe for watering shall be provided in slanting manner. (ii) Earth pit cover is to be made 10mm MS plate with the projection to overlap the four side of the road covered upto 10cm with collapsable MS handle.
M&L for Earthing to equipments etc with & including galvanised mild steel earth plate electrode of size 60 cm x 60 cm x 6 mm thick buried vertically in ground (earth pit not less than 2.25 m below normal ground level) with top edge of the earth plate at a depth not less than 1.5 m below ground level, the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides, connected to & including galvanized mild steel strip 32x6 mm as earth lead, including nuts, bolts, check nuts & washers of galvanized iron or steel and riveted/ welded to earth plate at one end and other end of strip connected to equipment body / test point with two Nos nuts bolts or welding with steel structure, GI earth strip encased in and including 40mm bore GI light grade pipe with all fittings from upper edges of earth plate upto 7.5 metre above ground level fixed with and including 25x3mm flat iron clamps, bolts, nuts and washer and also including providing watering pipe 20mm bore GI pipe medium grade from earth pit to top of electrode and including funnel, wire mesh, copper lugs etc complete with earth pit in PCC 1:3:6 type C1 using 20mm graded crushed stone aggregate and 40mm thick RCC (1:2:4 type B1) cover complete all as specified and shown in electrical plate No 3 of SSR Part-I including necessary excavation and earthwork in any type of soil, returning, filling in approved soil and disposal of surplus soil to a distance not exc 50m including dismantling & taking out old existing unserviceable earthing complete all as specified & as directed. Note : PCC chamber shall be constructed at least 1.5 mtr away from the earth electrode and pipe for watering shall be provided in slanting manner.
Taking down old unserviceable aluminium strip from roof and wall of ESHs any size and position including making good to distrubed surface of wall and roof complete all as specified and directed.
Supply and fixing aluminium strip 25mm x3mm complete with insulator/saddles and fixing with screws/accessories etc for fitting the strip for roof conductor & down conductors above ground level complete all as specified & as directed. Note : Rate of insulators shall be deemed to be included in quoted rates.
Supply and fixing Galvanized iron strip 32mm x6mm with saddles and fixing on wall or buried in ground or any other indicated situation including taking down old unserviceable GI strip including making good to distrubed surface complete all as specified & as directed.
Re-fixing of serviceable aluminium strip 25x3mm complete as obtained from serial item No. 151.00 of BoQ here-in-before with on new saddles/ insulators, including straightning and fixing screws/ accessories for roof and down conductor complete all as specified and directed. Note : (i) Fixing of serviceable insulators will be deemed to be included with quoted rates. (ii) Rate of new insulators shall be deemed to be included with quoted rates.
M&L for Air termination, single pointed aluminium rod 12mm dia 300mm long including taking down old unserviceable air termination complete all as specified & as directed.
M&L in replacement of test point terminal block made of gun metal or phosphorus bronze size 75mm x 75mm x 25mm, drilled and screwed including 3 Nos, 8mm dia, 25mm long hexagonal head screws with nuts & washers complete all as specified & as directed.
M&L for Galvanized iron tubing 40mm bore light grade, ISI marked, including all fittings for protection of GI strip including taking up or down existing unserviceable steel water tubing and connections of 40mm bore complete all as specified and directed.
M&L for Galvanized iron tubing 40mm bore medium grade, ISI marked, including all fittings for protection of GI strip including taking up or down existing unserviceable steel water tubing and connections of 40mm bore complete all as specified and directed.
Supply and fixing in replacement old unserviceable porcelain insulator for conductor 25x3/3.15 strip with one metre interval secured with suitable screw complete all as specified and directed.
Supply and fixing in replacement old unserviceable porcelain insulator for conductor 32x6mm strip with one metre interval secured with suitable screw complete all as specified and directed.
S&F Aluminium Conductor Steel Reinforced (ACSR) of any size as directed, stringing for air termination points supported by GI tubing on the roof of the ESHs to inner connect the all termination points including jointing with and including aluminium binding wire 2mm dia, jumpers, tapes, stretching properly, etc including dismantling and taking down old existing unserviceable aluminium conductor steel reinforced (ACSR) of any size/type/ capacity, complete all as specified and as directed. Notes : (i) The ACSR conductors shall conforming to IS-398 (Part-II) and as specified in SSR Part-I. (ii) The unit rate quoted shall also deemed to include for supply and fixing of binding wire, aluminium tapes, etc which shall not be included in the weight of conductors for payment. (iii) Weight of conductors shall be determined by measuring the horizontal distance between centers of two adjacent poles and compounding the weight of conductors of that size and length and 3% extra shall be added for sag, jointing, jumpers etc. (iv) Weight of the conductors shall be calculated from the nominal weights given in tables in the relevant IS code.
S&F for Stay assembly to support GI pipe for air termination by providing 7/4mm dia GI stay strand 15m, 16mm mild steel rod 1.35 RM and PCC block 1:3:6 size of 0.60x0.60x0.15m including earth work in soft loose soil including taking out old unserviceable stay assembly complete all as specified and as directed.
S&F cross arms, bracing, supports, clamps and back plates fabricated from structural steel sections conforming to Grade E-165 (Fe 290) including nuts, bolts, washers, welding, bending cold or hot, drilled holes for bolts, in any shape or size as directed with & including applying two coats of aluminium paint (under & finishing coats) over a coat of red oxide zinc chromate primer on exposed steel surfaces after preparation of surfaces including taking down old cross arms, bracing, supports, clamps and back plates etc complete all as specified and as directed . Note: - (i) Sizes, sections & types of members and shape of the cross arms etc shall be as required at site and all as directed. (ii) Un-exposed steel surfaces shall be given one coat of red-oxide zinc chromate primer only. Cost of the same is included in unit rate of the item and nothing extra shall be paid on this account. (iii) Weight of paint shall not be considered for payment purpose and quoted rate shall deemed to be included this aspect.
Supply, laying, jointing and testing LT XLPE insulated screened, bedded, galvanised steel strip or wire armoured heavy duty electric cable with aluminium stranded conductor 1100 Volt grade cross sectional area 50 sqmm 3.5 core laid in trenches/ducts, through pipe, under floors or roads/ along poles etc including dismantling & taking out old unserviceable cable complete all as specified and directed. Notes :- (i) Sand cushioning, cable protection, GI protection pipe, clamps, jointing kits and excavation & earth work shall be measured & paid for separately. (ii) Road cutting/floor cutting /cutting holes etc in walls required for laying/fixing of cable etc shall be made good as per existing. Nothing extra shall be admissible on this account. Quoted rates shall be inclusive of the above provisions.
Supply, laying, jointing and testing LT XLPE insulated screened, bedded, galvanised steel strip or wire armoured heavy duty electric cable with aluminium stranded conductor 1100 Volt grade cross sectional area 25 sqmm 4 core laid in trenches/ducts, through pipe, under floors or roads/ along poles etc including dismantling & taking out old unserviceable cable complete all as specified and directed. Notes :- (i) Sand cushioning, cable protection, GI protection pipe, clamps, jointing kits and excavation & earth work shall be measured & paid for separately. (ii) Road cutting/floor cutting /cutting holes etc in walls required for laying/fixing of cable etc shall be made good as per existing. Nothing extra shall be admissible on this account. Quoted rates shall be inclusive of the above provisions.
M&L for sand cushioning using unwashed dry river sand for underground cable 8 cm before laying cable and 15 cm after laying and punned to 18 cm after laying of under ground electric cable complete all as specified and as directed. Notes :-(i) Approved local unwashed dry river sand free from vegetations, grass and other deleterious substances shall be used. (ii) For the purpose of payment, only punned thickness shall be measured.
M&L for sub class ‘B’ (old size) burnt clay bricks laid flat and dry abutting each other with gap between adjacent bricks not exc. 10mm for protection of underground electric cable in such a way that the length of brick is at right angle to the central axis of cable complete all as specified and as directed.
Boring of holes of under road, pavement, hard standing, (minimum 1.0m below) by suitable machine / manually without disturbing the top surface suitable for laying of GI pipe upto 80mm bore protection pipe/ cables complete all as specified and as directed.
M&L for Galvanized iron tubing, 50mm bore light grade, ISI marked, including all fittings and laid in trenches/under road/drains, fixed to poles/walls with required size of flat iron (25mmx3mm) clamps, bolts, nuts and washers for protection of LT electric cable complete all as specified and directed.
Excavating in trenches, not exc 1.5 metre wide and not exc 1.5 metre in depth, for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. laying cables, pipes, etc. not exc 10 Sqm on plan & not exc 1.5m in depth and getting out in soft/loose soil complete all as specified and as directed.
Returning, filling in, including spreading, leveling watering and well ramming in layers not exc 25 cm thick in soft/loose soil complete all as specified and as directed.
Removing excavated soil/material to a distance not exc 50 metre and depositing where directed at a level not exc 1.50 metre above the starting point complete all as specified and as directed.
M&L for galvanized steel water tubing medium grade of 40mm bore with & including all fittings complete, laid in trenches, including taking up or down old unserviceable steel water tubing and connections of 40mm bore, complete all as specified and directed. Note :- Excavation & earthwork shall be measured & paid for separately under relevant items of this Schedule.
M&L for galvanized steel water tubing medium grade of 20mm bore with & including all fittings complete, laid in trenches, including taking up or down old unserviceable steel water tubing and connections of 20mm bore, complete all as specified and directed. Note :- Excavation & earthwork shall be measured & paid for separately under relevant items of this Schedule.
M&L for Gun metal globe or gate valve, with iron wheel head, screwed both ends, ISI marked for 15mm bore pipe fixed as in repairs complete all as specified and directed.
M&L of MS clamp/ saddle piece made out of MS flat iron suitable to make ferrule and clamping for branch connections complete with GI socket welded it on one FI strip suitably positioned at the centre of pipe including drilling as per site requirement complete with MS nuts, bolts, washers and rubber packing for complete of size 80/40 mm bore pipe complete all as specified and directed.
M/S MAMTA CONSTRUCTIONS (BID ID -3514239)
M/s Singh Engineering Corporation (BID ID -3507546)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.43 MB
BOQ_830738.xls
BOQ • 0.41 MB
Tender.pdf
Tender Documents • 1.32 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .