| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹17.2 LAdmitted-Finance | -11.11% | ₹17.2 L | L1 | Admitted-Finance |
| 2 | L2₹18.2 L+₹1.0 L (6.00%)Admitted-Finance | -5.78% | ₹18.2 L+₹1.0 L (6.00%) | L2 | Admitted-Finance |
| 3 | L3₹19.7 L+₹2.5 L (14.7%)Admitted-Finance | +1.99% | ₹19.7 L+₹2.5 L (14.7%) | L3 | Admitted-Finance |
| 4 | Rejected-Technical | - | - | - | Rejected-Technical Non Responsive |
Tender Value
₹19.3 L
EMD Value
₹38,640
Closing Date
26 Aug 2026, 6:00 pmClosed
Executive Engineer (Electric)
PWD CAMPUS BHARATPUR
Electrical Utility Shifting Over Head to Under Ground Cabling at Soorwal to Kushtala Distt Sawai Madhopur
2026_CEPWD_591997_1
NIT-14-2026-27
Open Tender
Electrical Works
Percentage
180 days
Sawai Madhopur
Please refer Tender documents.
2 documents required · 2 mandatory
₹500
As per NIT
₹38,640
Yes
Bharatpur
19 Sept 2026
22 Aug 2026
27 Aug 2026
22 Aug 2026
26 Aug 2026
22 Aug 2026
24 Aug 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Providing & Laying XLPE insulated three core Armoured Aluminium cable for working voltage 11 K.V.(E) confirming IS :7098 P - 2 with H4- Grade electrolytic aluminium conductor confirming to IS: 8130 class-2 of purity >99.6 %, Insulation Screening: Extruded Semiconducting Compound followed by helically wrapped Copper Tape, round / flat strip armouring of cables , Inner / outer sheath PVC type ST-2 confirming to IS:5831 in existing RCC pipe / Hume Pipe/ Stoneware Pipe/ PVC pipe/ open duct/cable trench / Cable tray (with cable tie) including testing etc. as required of following size. | - | - | - | - |
| 2 | 3 core 185.0 Sq.mm | 700 | Mtr. | - | - |
| 3 | Providing & making heat shrinkable type indoor/outdoor/straight through terminations/ joint kit suitable for 11 KV / 33 KV (Earthed) cable with required components, prepration of cable ends. Type test report should be as per IS13573:2011 including testing etc. as required of following sizes. | - | - | - | - |
| 4 | 11 KV End Termination Kit Outdoor type | - | - | - | - |
| 5 | 3 core 120/150/185 Sq.mm | 30 | Each | - | - |
| 6 | 11 KV Straight Through Joint Kit | - | - | - | - |
| 7 | 3 core 120/150/185 Sq.mm | 3 | Each | - | - |
| 8 | Supply and installation of spike of M.S. rod 20mm dia 3.0mtr. long for earthing of (tower/pole) drive into earth by mechanical means sturcture connection the spike with cross arm top hamper PCC pole, lattics tower to earth etc. complete as per technical specification of DISCOM. | 10 | Each | 1,618 | ₹16,180 |
| 9 | Supply and fixing of 1.6 mm thick MS 11 kV Danger plates as per IS :2551-1982 & specification of Discom on the existing poles complete in all respectas as required. | 20 | Each | 294 | ₹5,880 |
| 10 | P / L of Double wall corrugated HDPE pipe confirming to IS : 16205 P-24, Stiffness Class 750 N, Externally corrugated and having smooth surface inside with HDPE Coupler, Elbow, Tee at required Depth below the ground for laying cable of following Nominal Outer dia. MFR Test report from NABL accrediated is to be submitted.(Excavation of trench, CC Haunching, Back filling of Earth with compaction is to be Paid Extra). | - | - | - | - |
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 7.79 MB
BOQ_1051073.xls
BOQ • 0.25 MB
Conditions.pdf
Tender Documents • 5.64 MB
UtilityShifting.pdf
Other Document • 6.07 MB
Annexure.pdf
Additional Documents • 1.72 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .