Loading…
Loading…
| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹11.3 LAdmitted-Finance | -48.99% | ₹11.3 L | L1 | Admitted-Finance |
| 2 | L2₹11.3 LAdmitted-Finance 21 10 SHOP NO 1 SECTOR 3 MAHABINI DELHI 110085 | NORTH WEST | DELHI | 110085 | -48.76% | ₹11.3 L | L2 | Admitted-Finance |
| 3 | L3₹11.8 LAdmitted-Finance NONE | -46.75% | ₹11.8 L | L3 | Admitted-Finance |
| 4 | L4₹12.7 LAdmitted-Finance 03 SHRI RAM ARCADE SHRIRAM PARISAR KHAJURI KALAN BHOPAL MADHYA PRADESH 462022 UDYAM MP 10 0000330 | BHOPAL | MADHYA PRADESH | 462022 | -42.42% | ₹12.7 L | L4 | Admitted-Finance |
| 5 | L5₹16.6 LAdmitted-Finance | -24.99% | ₹16.6 L | L5 | Admitted-Finance |
Tender Value
₹22.1 L
EMD Value
₹44,150
Closing Date
20 Jan 2026, 3:00 pmClosed
EE(E)
North Electrical Division, PWD, Dr. BSA Hospital, Sector -6, Rohini, Delhi - 110085
RMO Electro mechanical services in residential quarter in DA flat Sindhora Khurd Gulabi Bagh Delhi. Sh Renovation Repair of electrical work in TypeII III IV and TypeV Flats due to new allotments
2026_PWD_284742_1
91/NED/PWD/M-352/2025-26
Open Tender
Electrical Works
60 days
as per nit
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
₹44,150
Yes
20 Jan 2026
13 Jan 2026
20 Jan 2026
13 Jan 2026
20 Jan 2026
13 Jan 2026
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required. a) Group A
b) Group B
Wiring for light/ power plug with 2X4 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed steel conduit along with 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. a) 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
b) 2 X 6 sq. mm + 1 X 6 sq. mm earth wire
c) 2 X 10 sq. mm + 1 X 6 sq. mm earth wire
Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required. a) Group A
b) Group B
Supplying and drawing following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. a) 3 x 1.5 sq. mm
b) 3 x 4 sq. mm
c) 6 x 4 sq. mm
d) 3 x 6 sq. mm
Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. a) 20 mm
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. a) 5/6 A switch
b) 15/16 A switch
c) 3 pin 5/6 A socket outlet
d) 6 pin 15/16 A socket outlet
e) Bell push
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc. as required. a) 1 or 2 Module (75 mmX75 mm)
b) 3 Module (100 mmX75 mm)
c) 6 Module (200 mmX75 mm)
d) 8 Module (125 mmX125 mm)
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required.
Supplying & fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, "C" curve including connections, painting etc. as required.
Supplying and fixing PVC batten/ angle holder including connections etc. as required.
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) a) 8 way , Double door
b) 12 way , Double door
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator). a) 4 way (4 + 12), Double door
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. a) Single pole
Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32 A 240 V "C" curve DP MCB complete with connections, testing and commissioning etc. as required.
Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top along with 20 A "C" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
Supplying and fixing Cable End Box (Loose Wire Box) suitable for following single pole and neutral, sheet steel, MCB distribution board, 240 Volts, on surface/ recess, complete with testing and commissioning etc. as required. a) For 14 way, Double door SPN MCBDB
Supplying, Installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 °C to 40 °C, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10%, P. F.≥0.95, IP20, CRI >80, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM (Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in- Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm) a) 24 -26watt
S/I/T/C of 1200 mm sweep BEE 3 star rating ISI marked ceiling fan capacitor type with double ball bearing suitable for operation of single phase AC supply with power Consumption of 50W +/- 10% capable to deliver 215 CFM (min.), speed of 320 rpm (min.) i/c wiring the down rod of standard length (upto 30 cm) with 1.5 Sqmm FR PVC insulated copper conductor single core cable etc as reqd.
Supplying and Installation of 300 mm sweep 900 rpm heavy duty exhaust fan alongwith aluminium louvers shutter in the existing opening, i/c making the hole suitable the size of the above fan making good the damage, connection testing commisioning with 1.5 Sqmm FR PVC insulated copper conductor single core cable etc as reqd.
b) 40 Amp DP MCB
Less credit for dismantle material received from the work. Copper Wire assorted
5/15 switch,socket, bellpush, regulator
Holder assorted
DP sheet steel enclosure assorted
DB Assorted
SP, SPN MCB Assorted
Ceiling fan
Ex. Fan
40/63 Amp DP MCB
Batten / wall bracket Assorted
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.99 MB
BOQ_376607.xls
BOQ • 0.43 MB
Download all tender documents and submit your bid