Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance 39 A1 GANTHI ROAD ERUMAPATTI NAMAKKAL 637 013 | NAMAKKAL | NAMAKKAL | TAMIL NADU | 637013 | Admitted-Finance |
Tender Value
₹76 L
EMD Value
₹76,000
Closing Date
6 Oct 2022, 2:00 pmClosed
SE/NEDC/NAMAKKAL
DR NO 90/134A2 SUBA TOWERS NAMAKKAL
WORKS CONTRACT FOR EXECUTION OF WORKS UNDER RDS SCHEME IN VARAGUR SECTION IN T.M.PATTY FEEDER
2022_EB_253020_1
SPECNO058/2022-23DT16.09.2022
Open Tender
Electrical Works
Works
365 days
VARAGUR
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
₹76,000
Yes
11 Oct 2022
22 Sept 2022
7 Oct 2022
22 Sept 2022
6 Oct 2022
22 Sept 2022
EXCAVATION OF POLE PITS / Stay Set:
Excavation of pole pit upto 27' (8.0 m) Pole by using JCB or manual
Excavation of pole pit above 8.0 Mtr pole PSC/RCC/RSJ pole by using JCB or manual
Stay pit 4.5' to 5' depth by using JCB or manual
Hard rock requires blasting
ERECTION OF POLES AND ACCESSORIES
PSC/ RCC poles/Metal poles upto 8.00m. (27') by using JCB or manual
PSC/ RCC poles/Metal poles above 8.00m by using JCB ormaual
Metal supports above 9.00m/ RSJ/ Rail pole/ Fabricated poles/ Tubular pole by using JCB or maual
Erection of stay set complete
Fixing of Line Materials
Fixing of HT "V" cross arms (all types) / Channel cross arms/ Guarding Cross arms
Fixing of Guarding Cross arm
Fixing of Tapping Channel Cross arm
Fixing of LT 3 phase cross arms
Fixing of LT Single phase cross arms
Fixing of HT/LT TI Fittings
Fixing of Aluminium Knob
Fixing of HT pin Insulators 22 KV
Fixing of HT 22 KV strain disc.
Fixing of LT pin Insulator
Fixing of LT shackle
Re-sagging of HT/LT lines
Re-sagging ACSR 7/3.35mm / AAAC 3.15 mm Rabbit conductor
Re-sagging ACSR 7/2.59 mm / AAAC 2.50 mm Weasel and ACSR 7/2.11 mm conductor
SERVICE ERECTED:
Erection of street light including fixure fitting
Releasing of single phase service and re-fixing.
Releasing of 3 phase service and (upto 50 HP) re-fixing.
CONCRETING WORKS:
Sleeve concreting including materials (Cement + River Sand/ Msand and Blue metals and watering)
Stay Concreting including cost of materials and labour 375mmx375mmx50mm
EARTHING:
Earthing of pole with coil earthing including burying looping and binding.
LOADING AND UNLOADING CHARGES:
Loading of poles upto 8.0 M/ 27'
Loading of poles above 8.0 M
Loading of metal poles (All sizes)
UnLoading of poles upto 8.0 M/ 27'
UnLoading of poles above 8.0 M
UnLoading of metal poles (All sizes)
Loading of materials
Unloading of materials
Loading or unloading of Transformer upto 100 KVA
Erection of New Transformer all capacities (with jumpering)
Guarding Arrangement
HT Guarding
Transport of poles/Materials/ conductors and other materials (excluding loading and unloading charges.)
Below 8 Kms (Plains)
Above 8 Kms. For additional Km (Irrespective of weight in tonnage)
Transporting of poles from road side to pole pit including loading and unloading of poles by using JCB or manual beyond 100 m
Dismantling Charges
Dismantling of PSC/RCC upto pole 8.00 m (27')
Dismantling of PSC/RCC & above 8.00m
Dismantling of stay set complete
Dismantling of 1ph xarm
Dismantling of 3ph xarm
Dismantling of Tapping X arm / V cross arm
Dismantling of HT/LT TI fitting
Dismantling of 22kV Pin insulator
Dismantling of 22 kV strain disc
Dismantling of LT Pin insulator
Dismantling of LT shackle
Dismantling of Aluminium knob
Dismantling of conductor of size ACSR 7/2.59 /AAAC 7/2.50
Dismantling of conductor of size ACSR 7/3.35 /AAAC 7/3.15
PAINTING:
Painting of metal poles including cross arms (excluding cost of paint)
Lathe Works
Labour charges for alteration of Back Clamps/ Stay Clamps to suit for the works
DT/ DP erection
Erection of Single Pole Transformer structure complete in all respects with wiring, Earthing, fixing of open type fuse units, HT/LT LAS and jumpering 3 Nos. Earth pit with collar including painting of metal parts, structure poles, fixing of tapping channel, transformer bed structure including concreting (Except erection of Transformer)(Annexure III)
Erection of D.P. structure with AB switch, top channel, cross bracing, earthing, painting, providing stay including concreting (Annexure IV)
Paving of HT/LT Lines
ACSR 7/3.35 mm / AAAC 3.15mm Rabbit conductor in KM
ACSR 7/2.59 mm / AAAC 2.50mm Weasel and ACSR 7/2.11mm conductor in KM
Miscellaneous Works
Clearing of jungle
SHASHTIKA AGENCIES
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .