Item- 1 Items of Schedule-B (Items of DSR-2023)
S No. Item No Description of Item Unit Qty Rate Amount
2.0 EARTH WORK
2.1S General
Earth work in excavation by mechanical means
(Hydraulic excavator)/manual means over areas
(exceeding 30 cm in depth, 1.5 m in width as
2.6 well as 10 sqm on plan) including getting out
and disposal of excavated earth lead upto 50 m
and for all lift, as directed by Engineer-in-
ASANSOL DIVISION-ENGINEERING/EASTERN RLY
Earth work in excavation by mechanical means
(Hydraulic excavator) / manual means in
foundation trenches or drains (not exceeding
1.5 m in width or 10 sqm on plan), including
dressing of sides and ramming of bottoms, for
all lift, including getting out the excavated soil
and disposal of surplus excavated soil as
directed, within a lead of 50 m.
2.25 Filling available excavated earth (excluding cum 500 196 98000
rock) in trenches, plinth, sides of foundations
3 etc. in layers not exceeding 20 cm in depth,
consolidating each deposited layer by ramming
and watering, lead up to 50 and for all lift.
2.27 Supplying and filling in plinth with sand under cum 26 2123.75 55217.5
4 floors, including watering, ramming,
consolidating and dressing complete.
Surface dressing of the ground including
removing vegetation and in-equalities not
exceeding 15 cm deep and disposal of rubbish,
lead up to 50 m and lift up to 1.5 m.
2.31 Clearing jungle including uprooting of rank Sqm 110 17.6 1936
vegetation, grass, brush wood, trees and
saplings of girth up to 30 cm measured at a
height of 1 m above ground level and removal
of rubbish up to a distance of 50 m outside the
periphery of the area cleared.
4.0 CONCRETE WORK
4.1S CEMENT CONCRETE (CAST IN SITU)
Providing and laying in position cement
concrete of specified grade excluding the cost
of centering and shuttering - All work up to
derived from natural sources : 4 graded stone
aggregate 20 mm nominal size derived from
natural sources)
Providing and laying cement concrete in
retaining walls, return walls, walls (any
thickness) including attached pilasters,
columns, piers, abutments, pillars, posts, struts,
4.2 buttresses, string or lacing courses, parapets,
coping, bed blocks, anchor blocks, plain window
sills, fillets, sunken floor etc., up to floor five
level, excluding the cost of centering, shuttering
derived from natural sources : 4 graded stone
aggregate 20 mm nominal size derived from
natural sources)
Centering and shuttering including strutting,
propping etc. and removal of form work for :
9 4.3.1 Foundations, footings, bases for columns Sqm 180 392.15 70587
4.3.2 Retaining walls, return walls, walls (any Sqm 150 842.5 126375
thickness) including attached pilasters,
buttresses, plinth and string courses fillets,
kerbs and steps etc.
4.3.3 Columns, piers, abutments, pillars, posts and Sqm 180 961.3 173034
5.0 REINFORCEMENT CEMENT CONCRETE
5.1S CAST IN SITU
Providing and laying in position specified grade
of reinforced cement concrete, excluding the
cost of centering, shuttering, finishing and
reinforcement - All work up to plinth level :
ASANSOL DIVISION-ENGINEERING/EASTERN RLY
derived from natural sources : 3 graded stone
aggregate 20 mm nominal size derived from
natural sources)
Reinforced cement concrete work in walls (any
thickness), including attached pilasters,
buttresses, plinth and string courses, fillets,
5.2 columns, pillars, piers, abutments, posts and
struts etc. above plinth level up to floor five
level, excluding cost of centering, shuttering,
finishing and reinforcement :
derived from natural sources : 3 graded stone
aggregate 20 mm nominal size derived from
natural sources)
5.3 Reinforced cement concrete work in beams, cum 50 11505.5 575275
suspended floors, roofs having slope up to 15
degree landings, balconies, shelves, chajjas,
lintels, bands, plain window sills, staircases and
spiral stair cases above plinth level up to floor
14 five level, excluding the cost of centering,
shuttering, finishing and reinforcement with
1:1.5:3 (1 cement : 1.5 coarse sand(zone-III)
derived from natural sources : 3 graded stone
aggregate 20 mm nominal size derived from
natural sources).
5.4 Providing and laying reinforced cement cum 5 8821.65 44108.25
concrete in kerbs, steps and the like at or near
ground level excluding the cost of centering,
shuttering, finishing and reinforcement with
1:1.5:3 (1 cement : 1.5 coarse sand (zone-III)
derived from natural sources :3 graded stone
aggregate 20 mm nominal size derived from
natural sources).
5.9S FORM WORK
Centering and shuttering including strutting,
propping etc. and removal of form for
5.9.1 Foundations, footings, bases of columns, etc. Sqm 480 392.15 188232
for mass concrete
5.9.2 Walls (any thickness) including attached Sqm 200 842.5 168500
17 pilasters, buttresses, plinth and string courses
5.9.3 Suspended floors, roofs, landings, balconies Sqm 270 927.25 250357.5
and access platform
5.9.5 Lintels, beams, plinth beams, girders, Sqm 300 736.4 220920
bressummers and cantilevers
5.9.6 Columns, Pillars, Piers, Abutments, Posts and Sqm 180 961.3 173034
5.12S PRE-CAST RCC
5.12 Providing, hoisting and fixing above plinth level cum 12 10585.9 127030.8
up to floor five level precast reinforced cement
concrete work in string courses, bands, copings,
bed plates, anchor blocks, plain window sills
and the like, including the cost of required
centering, shuttering but , excluding cost of
reinforcement with 1:1.5:3 (1 cement : 1.5
coarse sand (zone-III) derived from natural
sources : 3 graded stone aggregate 20 mm
nominal size derived from natural sources).
5.22S STEEL REINFORCEMENT
Steel reinforcement for R.C.C. work including
straightening, cutting, bending, placing in
position and binding all complete upto plinth
5.22.6 Thermo-Mechanically Treated bars of grade Fe- Kg 27000 107.85 2911950
ASANSOL DIVISION-ENGINEERING/EASTERN RLY
Steel reinforcement for R.C.C. work including
straightening, cutting, bending, placing in
position and binding all complete above plinth
5.22A.6 Thermo-Mechanically Treated bars of grade Fe- Kg 12000 107.85 1294200
6.0 MASONRY WORK
6.1S General
Brick work with common burnt clay F.P.S. (non
6.1 modular) bricks of class designation 7.5 in
foundation and plinth in:
Brick work with common burnt clay F.P.S. (non
modular) bricks of class designation 7.5 in
superstructure above plinth level up to floor V
level in all shapes and sizes in :
6.12S HALF BRICK MASONRY
Half brick masonry with common burnt clay
F.P.S. (non modular) bricks of class designation
7.5 in superstructure above plinth level up to
8.0 CLADDING WORK
8.1S General
Providing and fixing 18 mm thick gang saw cut,
mirror polished, premoulded and prepolished,
machine cut for kitchen platforms, vanity
counters, window sills, facias and similar
locations of required size, approved shade,
colour and texture laid over 20 mm thick base
cement mortar 1:4 (1 cement : 4 coarse sand),
joints treated with white cement, mixed with
matching pigment, epoxy touch ups, including
rubbing, curing, moulding and polishing to
edges to give high gloss finish etc. complete at
Granite stone slab colour black, Cherry/Ruby
Providing edge moulding to 18 mm thick marble
stone counters, Vanities etc., including machine
8.3 polishing to edge to give high gloss finish etc.
complete as per design approved by Engineer-
8.20S STONE WORK DRY CLADDING
8.31 Providing and fixing Ist quality ceramic glazed Sqm 1650 1267.95 2092117.5
wall tiles conforming to IS: 15622 (thickness to
be specified by the manufacturer), of approved
make, in all colours, shades except burgundy,
bottle green, black of any size as approved by
29 Engineer-in-Charge, in skirting, risers of steps
and dados, over 12 mm thick bed of cement
mortar 1:3 (1 cement : 3 coarse sand) and
jointing with grey cement slurry @ 3.3kg per
sqm, including pointing in white cement mixed
with pigment of matching shade complete.
9.0 WOOD AND P.V.C. WORK
9.1S FRAMES AND TRUSSES
ASANSOL DIVISION-ENGINEERING/EASTERN RLY
Providing and fixing ISI marked flush door
shutters conforming to IS : 2202 (Part I) non-
decorative type, core of block board
9.21 construction with frame of 1st class hard wood
and well matched commercial 3 ply veneering
with vertical grains or cross bands and face
veneers on both faces of shutters:
9.21.2 30 mm thick including ISI marked Stainless Sqm 12 2172.1 26065.2
Steel butt hinges with necessary screws
9.40S MISCELLANEOUS-WOOD WORK
Providing and fixing chromium plated brass
curtain rod having wall thickness of 1.25mm
9.46 with two chromium plated brass brackets fixed
with C.P. brass screws and PVC sleeves etc.,
wherever necessary complete :
COPER OXIDISED MILD STEEL FITTINGS
(COPPER OXIDISED AS PER IS: 1378)
Providing and fixing ISI marked oxidised M.S.
9.62 sliding door bolts with nuts and screws etc.
complete (Copper oxidised as per IS 1378)
Providing and fixing ISI marked oxidised M.S.
tower bolt black finish, (Barrel type) with
necessary screws etc. complete (Copper
oxidised as per IS 1378)
Providing and fixing ISI marked oxidised M.S.
handles conforming to IS:4992 with necessary
screws etc. complete (Copper oxidised as per IS
ANODISED ALUMINIUM FITTINGS (ALL FITTINGS
SHALL BE ISI MARKED)
Providing and fixing aluminium handles, ISI
marked, anodised (anodic coating not less than
9.100 grade AC 10 as per IS : 1868) transparent or
dyed to required colour or shade, with
necessary screws etc. complete :
Providing and fixing aluminium hanging floor
door stopper, ISI marked, anodised (anodic
coating not less than grade AC 10 as per IS :
1868) transparent or dyed to required colour
and shade, with necessary screws etc.
9.105S GYPSUM BOARD PARTITIONS
9.119 Providing and fixing factory made P.V.C. door Metre 50 492.7 24635
frame of size 50x47 mm with a wall thickness of
5 mm, made out of extruded 5 mm rigid PVC
foam sheet, mitred at corners and joined with 2
Nos of 150 mm long brackets of 15x15 mm M.S.
square tube, the vertical door frame profiles to
37 be reinforced with 19x19 mm M.S. square tube
of 19 gauge, EPDM rubber gasket weather seal
to be provided through out the frame. The door
frame to be fixed to the wall using M.S. screws
of 65/100 mm size, complete as per
manufacturer's specification and direction of
Engineer- in-Charge.
ASANSOL DIVISION-ENGINEERING/EASTERN RLY
Providing and fixing factory made panel PVC
door shutter consisting of frame made out of
M.S. tubes of 19 gauge thickness and size of 19
mm x 19 mm for styles and 15x15 mm for top
& bottom rails. M.S. frame shall have a coat of
steel primers of approved make and
manufacture. M.S. frame covered with 5 mm
thick heat moulded PVC 'C' channel of size 30
mm thickness, 70 mm width out of which 50
mm shall be flat and 20 mm shall be tapered in
45 degree angle on both side forming styles
and 5 mm thick, 95 mm wide PVC sheet out of
which 75mm shall be flat and 20 mm shall be
tapered in 45 degree on the inner side to form
top and bottom rail and 115 mm wide PVC
9.120 sheet out of which 75 mm shall be flat and 20
mm shall be tapered on both sides to form lock
rail. Top, bottom and lock rails shall be
provided both side of the panel. 10 mm (5 mm
x 2 ) thick, 20 mm wide cross PVC sheet be
provided as gap insert for top rail & bottom rail,
panelling of 5 mm thick both side PVC sheet to
be fitted in the M.S. frame welded/ sealed to the
styles & rails with 7 mm (5 mm+2 mm) thick x
15 mm wide PVC sheet beading on inner side,
and joined together with solvent cement
adhesive. An additional 5 mm thick PVC strip of
20 mm width is to be stuck on the interior side
of the 'C' Channel using PVC solvent adhesive
etc. complete as per direction of Engineer-in-
charge, manufacturer's specification & drawing.
10.0 STEEL WORK
10.1S General
10.1 Structural steel work in single section, fixed Kg 600 117.35 70410
with or without connecting plate, including
39 cutting, hoisting, fixing in position and applying
a priming coat of approved steel primer all
10.2 Structural steel work riveted, bolted or welded Kg 87000 133.7 11631900
in built up sections, trusses and framed work,
40 including cutting, hoisting, fixing in position and
applying a priming coat of approved steel
primer all complete.
10.22 Welding by gas or electric plant including cm 50 3.7 185
transportation of plant at site etc. complete.
Steel work welded in built up sections/ framed
work, including cutting, hoisting, fixing in
10.25 position and applying a priming coat of
approved steel primer using structural steel etc.
10.25.2 In gratings, frames, guard bar, ladder, railings, Kg 1275 172.6 220065
brackets, gates and similar works
10.28 Providing and fixing stainless steel ( Grade 304) Kg 20 772.4 15448
railing made of Hollow tubes, channels, plates
etc., including welding, grinding, buffing,
polishing and making curvature (wherever
required) and fitting the same with necessary
stainless steel nuts and bolts complete,
including fixing the railing with necessary
43 accessories & stainless steel dash fasteners ,
stainless steel bolts etc., of required size, on
the top of the floor or the side of waist slab with
suitable arrangement as per approval of
Engineer-in-charge, (for payment purpose only
weight of stainless steel members shall be
considered excluding fixing accessories such as
nuts, bolts, fasteners etc.).
ASANSOL DIVISION-ENGINEERING/EASTERN RLY
Providing and fixing glass panes with putty and
10.30 glazing clips in steel doors, windows, clerestory
windows, all complete with :
11.0 FLOORING
11.1S General
Cement concrete flooring 1:2:4 (1 cement : 2
coarse sand : 4 graded stone aggregate)
11.3 finished with a floating coat of neat cement,
including cement slurry, but excluding the cost
of nosing of steps etc. complete.
11.3.1 40 mm thick with 20 mm nominal size stone Sqm 40 614.2 24568
11.16S TILE FLOORING
Chequered precast cement concrete tiles 22
mm thick in footpath & courtyard, jointed with
neat cement slurry mixed with pigment to
match the shade of tiles, including rubbing and
cleaning etc. complete, on 20 mm thick bed of
cement mortar 1:4 (1 cement: 4 coarse sand).
46 11.20.4 Ordinary cement without any pigment Sqm 2000 1056.35 2112700
11.37S CERAMIC GLAZED TILES
11.37 Providing and laying Ceramic glazed floor tiles Sqm 550 1096.55 603102.5
of size 300x300 mm (thickness to be specified
by the manufacturer) of 1st quality conforming
to IS : 15622 of approved make in colours such
as White, Ivory, Grey, Fume Red Brown, laid on
20 mm thick cement mortar 1:4 (1 Cement : 4
Coarse sand), Jointing with grey cement slurry
@ 3.3 kg/sqm including pointing the joints with
white cement and matching pigment etc.,
11.41S VITRIFIED FLOOR TILES
Providing and laying vitrified floor tiles in
different sizes (thickness to be specified by the
manufacturer) with water absorption less than
0.08% and conforming to IS: 15622, of
approved make, in all colours and shades, laid
on 20mm thick cement mortar 1:4 (1 cement : 4
coarse sand), jointing with grey cement slurry
@ 3.3 kg/ sqm including grouting the joints with
white cement and matching pigments etc.,
12.0 ROOFING
12.1S SHEET ROOFING
12.11 Extra for providing and fixing wind ties of 40x 6 Metre 800 195.6 156480
mm flat iron section.
12.37S RAIN WATER SPOUT AND PIPE
Providing and fixing on wall face unplasticised
Rigid PVC rain water pipes conforming to IS :
12.41 13592 Type A, including jointing with seal ring
conforming to IS : 5382, leaving 10 mm gap for
thermal expansion, (i) Single socketed pipes.
Providing and fixing on wall face unplasticised -
PVC moulded fittings/ accessories for
unplasticised Rigid PVC rain water pipes
conforming to IS : 13592 Type A, including
jointing with seal ring conforming to IS : 5382,
leaving 10 mm gap for thermal expansion.
12.42.5 Bend 87.5 degree
ASANSOL DIVISION-ENGINEERING/EASTERN RLY
12.50 Providing and fixing precoated galvanised iron Sqm 2500 738.65 1846625
profile sheets (size, shape and pitch of
corrugation as approved by Engineer-in-charge)
of total coated thickness 0.50 mm (base metal
of minimum 0.45 mm thickness with total
coating thickness of 0.05 mm) with zinc coating
120 grams per sqm as per IS: 277, in 240 mpa
steel grade, 5-7 microns epoxy primer on both
side of the sheet and polyester top coat 15-18
microns. Sheet should have protective guard
film of 25 microns minimum to avoid scratches
during transportation and should be supplied in
single length upto 12 metre or as desired by
Engineer-in-charge. The sheet shall be fixed
using self drilling /self tapping screws of size
(5.5x 55 mm) with EPDM seal, complete upto
any pitch in horizontal/ vertical or curved
surfaces, excluding the cost of purlins, rafters
and trusses and including cutting to size and
shape wherever required.
Providing and fixing precoated galvanised steel
sheet roofing accessories of total coated
thickness 0.50 mm (base metal of minimum
0.45 mm thickness with total coating thickness
12.51 of 0.05 mm) with Zinc coating 120 grams per
sqm as per IS: 277, in 240 mpa steel grade, 5-7
microns epoxy primer on both side of the sheet
and polyester top coat 15-18 microns using self
drilling/ self tapping screws complete :
Providing and fixing of Pre-coated colour or mill
finish Aluminium Roofing Accessories in 0.71
mm thickness ,Alloy 31500 (IS designation)
[Aluminium Alloy (AA) 3004 (ISO designation)]
For colour, coating shall be 5-7 microns epoxy
primer on both sides of the sheet and polyester
top coat 15-18 microns, using self
drilling/tapping SS screws of size 6 x 50 mm
with 3 mm thick EPDM seal and SS plain washer
12.66.6 Precoated/mill finish aluminium Gutter (600 mm Metre 60 1808.65 108519
over all girth)
13.0 FINISHING
13.1S CEMENT PLASTER (IN FINE SAND)
13.1 12 mm cement plaster of mix :
15 mm cement plaster on the rough side of
single or half brick wall of mix :
CEMENT PLASTER WITH A FLOATING COAT OF
12 mm cement plaster finished with a floating
coat of neat cement of mix :
13.16S 6 mm CEMENT PLASTER
13.16 6 mm cement plaster of mix :
13.37S INTERIOR FINISHING
Distempering with 1st quality acrylic distemper
(ready mixed) having VOC content less than 50
13.41 gram/litre, of approved manufacturer and of
required shade and colour all complete to
achieve even shade and colour :
ASANSOL DIVISION-ENGINEERING/EASTERN RLY
13.41.1 New work (two or more coats) over and Sqm 1500 185.65 278475
including water thinnable priming coat with
cement primer having VOC content less than 50
13.44S EXTERIOR FINISHING
Finishing walls with water proofing cement paint
of required shade :
13.44.1 New work (Two or more coats applied @ 3.84 Sqm 2500 116.9 292250
Painting with synthetic enamel paint of
13.61 approved brand and manufacture to give an
Painting with aluminium paint of approved
brand and manufacture to give an even shade .
Lettering with black Japan paint of approved letter
brand and manufacture per cm
13.80 Providing and applying white cement based Sqm 3000 156.05 468150
putty of average thickness 1 mm, of approved
64 brand and manufacturer, over the plastered
wall surface to prepare the surface even and
smooth complete.
15.0 DISMANTLING AND DEMOLISHING
15.1S General
Demolishing cement concrete manually/ by
mechanical means including disposal of
material within 50 metres lead as per direction
of Engineer - in - charge.
15.2.1 Nominal concrete 1:3:6 or richer mix (including cum 20 2434.25 48685
equivalent design mix)
15.3 Demolishing R.C.C. work manually/ by cum 8 3551.25 28410
mechanical means including stacking of steel
66 bars and disposal of unserviceable material
within 50 metres lead as per direction of
Engineer - in- charge.
Demolishing brick work manually/ by
mechanical means including stacking of
15.7 serviceable material and disposal of
unserviceable material within 50 metres lead as
per direction of Engineer-in-charge.
Dismantling steel work in single sections
15.17 including dismembering and stacking within 50
metres lead in:
15.18 Dismantling steel work in built up sections in Kg 400 5.65 2260
angles, tees, flats and channels including all
69 gusset plates, bolts, nuts, cutting rivets,
welding etc. including dismembering and
stacking within 50 metres lead.
Dismantling roofing including ridges, hips,
15.28 valleys and gutters etc., and stacking the
material within 50 metres lead of:
16.0 ROAD WORK
16.1S ROADS
Dry brick pitching half brick thick in drains
16.12 including supply of bricks and preparing the
surface complete :
16.12.1 With common burnt clay F.P.S. (non modular) Sqm 240 644.05 154572
bricks of class designation 7.5
ASANSOL DIVISION-ENGINEERING/EASTERN RLY
16.30S PREMIX CARPET
Providing and laying bitumen mastic wearing
course (as per specifications) with industrial
bitumen of grade 85/25 conforming to IS : 702,
prepared by using mastic cooker and laid to
required level and slope, including providing
antiskid surface with bitumen precoated fine
grained hard stone chipping of approved size at
the rate of 0.005 cum per 10 sqm and at
approximate spacing of10 cm centre to centre
in both directions, pressed into surface
protruding 1 mm to 4 mm over mastic surface,
including cleaning the surface, removal of
debris etc. all complete. (Considering bitumen
using 10.2% as per MORTH specification).
16.49S MISCELLANEOUS
Manufacturing, supplying and fixing retro
reflective overhead signage boards made up of
2 mm thick aluminium sheet, face to be fully
covered with high intensity and encapsulated
lens type heat activated retro reflective
sheeting conforming to type - III of ASTM-D-
4956-01 as approved by Engineer-in-charge,
letters, borders etc. as per IRC : 67-2001 in
silver white with blue colour back ground and
with high intensity grade, pasted on substrate
by pressure sensitive adhesive backing which
shall be activated by applying pressure
conforming to class II of ASTM-D-4956-01 and
fixing the same to the plate of structural frame
work by means of suitable sized aluminium
alloys, rivets or bolts & nuts @ 300 mm centre
to centre all along the periphery as well as in
two vertical rows along with theft resistant
measures, including the cost of painting with
two or more coats of epoxy paint in grey colour
on the back side of aluminium sheet including
appropriate priming coat. The rate includes the
cost of rounding off the corners, lowering down
the structural frame work from the gantry,
fixing and erecting the same in position all
complete as per drawings, specification and
direction of the engineer-in-charge.(Structural
frame work including M.S. plate to be provided
separately. Rectangular area of the sheet only
shall be measured for payment).
73 16.60.1 Overhead informatory road signage Sqm 2 5879.9 11759.8
17.0 SANITARY INSTALLATIONS
17.1S General
Providing and fixing water closet squatting pan
(Indian type W.C. pan ) with 100 mm sand cast
Iron P or S trap, 10 litre low level white P.V.C.
flushing cistern, including flush pipe, with
manually controlled device (handle lever)
conforming to IS : 7231,with all fittings and
fixtures complete, including cutting and making
good the walls and floors wherever required:
17.1.1 White Vitreous china Orissa pattern W.C. pan of Each 8 6767.4 54139.2
size 580x440 mm with integral type foot rests
Providing and fixing wash basin with C.I.
brackets, 15 mm C.P. brass pillar taps, 32 mm
17.7 C.P. brass waste of standard pattern, including
painting of fittings and brackets, cutting and
making good the walls wherever require:
17.7.1 White Vitreous China Wash basin size 630x450 Each 10 2648.85 26488.5
mm with a pair of 15 mm C.P. brass pillar taps
ASANSOL DIVISION-ENGINEERING/EASTERN RLY
Providing and fixing white vitreous china water
closet squatting pan (Indian type) :
Providing and fixing P.V.C. low level flushing
cistern with manually controlled device (handle
lever) conforming to IS : 7231, with all fittings
and fixtures complete.
Providing and fixing P.V.C. waste pipe for sink
17.28 or wash basin including P.V.C. waste fittings
17.28.2 Flexible pipe
18.0 WATER SUPPLY
18.4S PP-R PIPES
Providing and fixing 3 layer PP-R (Poly
propylene Random copolymer) pipes confirming
to IS 15801, UV stabilized & anti - microbial
fusion welded, having thermal stability for hot &
cold water supply, including all PP - R plain &
brass threaded polypropylene random fittings
and fixing the pipe with clamps at 1.00 m
spacing. This includes testing of joints complete
as per direction of Engineer-in-Charge. (
Internal Exposed on walls )
Providing and fixing 3 layer PP-R (Poly
propylene Random copolymer) pipes confirming
to IS:15801, UV stabilized & anti - microbial
fusion welded, having thermal stability for hot &
cold water supply, including all PP - R plain &
brass threaded polypropylene random fittings
and fixing the pipe with clamps at 1.00 m
spacing. This includes the cost of cutting chases
and making good the same including testing of
joints complete as per direction of Engineer-in-
C h a r g e . Concealed work, including cutting
chases and making good the wall etc.
Providing and fixing 3 layer PP-R (Poly
propylene Random copolymer) pipes confirming
to IS:15801 UV stabilized & anti - microbial
fusion welded, having thermal stability for hot &
18.6 cold water supply, including all PP - R plain &
brass threaded polypropylene random fittings,
including trenching, refilling & testing of joints
complete as per direction of Engineer-in-
Charge. External work
18.6A Providing and fixing PPR Unions
18.7S C.P.V.C. PIPES
ASANSOL DIVISION-ENGINEERING/EASTERN RLY
18.14 Fixing water meter and stop cock in G.I. pipe Each 1 812.3 812.3
line including cutting and threading the pipe
91 and making long screws etc. complete (cost of
water meter and stop cock to be paid
18.15S BRASS FITTINGS
Providing and fixing brass bib cock of approved
Providing and fixing brass stop cock of
approved quality :
Providing and fixing gun metal gate valve with
C.I. wheel of approved quality (screwed end) :
Providing and fixing ball valve (brass) of
18.18 approved quality, High or low pressure, with
plastic floats complete :
Providing and fixing uplasticised PVC
connection pipe with brass unions :
18.21.1 30 cm length
C.I. SLUICE VALVES/ FIRE HYDRANTS &
Boring with 100 mm diameter casing pipe for
hand pump / tubewell, in all soils except
18.42 ordinary hard rocks requiring blasting, including
removing the casing pipe after the hand pump /
tube well is lowered and tested :
18.43 Providing and placing in position filters of 40 Metre 36 960.3 34570.8
105 mm diameter G.I. pipe with brass strainer of
approved quality.
18.44 Providing and fixing to filter and lowering to Metre 36 546 19656
106 proper levels 40 mm G.I. pipe for tube well
including cleaning and priming the tube well.
18.45 Providing and placing in position hand pump of Each 2 1321.65 2643.3
107 approved quality for 40 mm diameter G.I. pipe
complete with all accessories.
Providing and fixing G.I. Union in G.I. pipe
18.46 including cutting and threading the pipe and
making long screws etc. complete (New work) :
Providing and fixing G.I. Union in existing G.I.
pipe line, cutting and threading the pipe and
18.47 making long screws, including excavation,
refilling the earth or cutting of wall and making
good the same complete wherever required :
ASANSOL DIVISION-ENGINEERING/EASTERN RLY
18.48 Providing and placing on terrace (at all floor Per 17500 11 192500
levels) polyethylene water storage tank, IS : Litre
12701 marked, with cover and suitable locking
arrangement and making necessary holes for
inlet, outlet and overflow pipes but without
fittings and the base support for tank.
18.49S C.P. BRASS FITTINGS
Providing and fixing C.P. brass bib cock of
approved quality conforming to IS:8931 :
Providing and fixing C.P. brass long nose bib
18.50 cock of approved quality conforming to IS
standards and weighing not less than 810 gms.
Providing and fixing C.P. brass stop cock
18.52 (concealed) of standard design and of approved
make conforming to IS:8931.
18.54S PTMT FITTINGS
Providing and fixing PTMT bib cock of approved
quality and colour.
18.54.1 15 mm nominal bore, 86 mm long, weighing Each 12 125.6 1507.2
not less than 88 gms
Providing and fixing PTMT stop cock of
approved quality and colour.
18.55.1 15 mm nominal bore, 86 mm long, weighing Each 10 118.5 1185
not less than 88 gms
Providing and fixing PTMT pillar cock of
approved quality and colour.
18.56.1 15 mm nominal bore, 107 mm long, weighing Each 10 208.45 2084.5
not less than 110 gms
Providing and fixing PTMT, push cock of
approved quality and colour.
not less than 75 gms
21.0 ALUMINIUM WORK
21.1S General
Providing and fixing glazing in aluminium door,
window, ventilator shutters and partitions etc.
with EPDM rubber / neoprene gasket etc.
21.3 complete as per the architectural drawings and
the directions of engineer-in-charge . (Cost of
aluminium snap beading shall be paid in basic
21.3.1 With float glass panes of 4.0 mm thickness Sqm 4.3 1176.8 5060.24
(weight not less than 10kg/sqm)
23.0 RAIN WATER HARVESTING & TUBEWELLS
23.1S General
Boring/drilling bore well of required dia for
casing/ strainer pipe, by suitable method
prescribed in IS: 2800 (part I), including
collecting samples from different strata,
preparing and submitting strata chart/ bore log,
including hire & running charges of all
equipments, tools, plants & machineries
required for the job, all complete as per
direction of Engineer-in-charge, upto 90 metre
depth below ground level.
23.1.1 All types of soil
ASANSOL DIVISION-ENGINEERING/EASTERN RLY
Boring/drilling bore well of required dia for
casing/ strainer pipe, by suitable method
prescribed in IS: 2800 (part I), including
collecting samples from different strata,
preparing and submitting strata chart/ bore log,
23.2 including hire & running charges of all
equipments, tools, plants & machineries
required for the job, all complete as per
direction of Engineer -in-charge, beyond 90
metre & upto 150 metre depth below ground
23.2.1 All types of soil
Supplying, assembling, lowering and fixing in
vertical position in bore well, unplasticized PVC
medium well casing (CM) pipe of required dia,
23.3 conforming to IS: 12818, including required hire
and labour charges, fittings & accessories etc.
all complete, for all depths, as per direction of
Engineer -in-charge.
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
GCCACS11.pdf
ATTACHMENT
Tenderdocuments.pdf
ATTACHMENT
AnnexuresforCommercialcompliances.pdf Annexures for Commercial Compliance
ATTACHMENT
JPOTelecomcircular9of2023_1.pdf
ATTACHMENT
ANNEXURE-X_A_.pdf
ATTACHMENT
Annexure-X_1.pdf
ATTACHMENT
Annexuresoftechnicalcompliancess.pdf
ATTACHMENT
ACSlipsGCC-2022.pdf
ATTACHMENT
GCC-2022_2.pdf
ATTACHMENT
CheckList.pdf
ATTACHMENT
AnnexuresforCommercialcompliances.pdf
ATTACHMENT
Download all tender documents and submit your bid