Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.8 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹15.0 L+₹1.7 L (12.5%)Rejected-Finance | L2 | Rejected-Finance Being L2 | |
| 3 | L3₹16.0 L+₹2.7 L (20.1%)Rejected-Finance STREET NO 10 MALLOMAZRA ROAD BHAKHRA ENCLAVE PATIALA PB | PATIALA | PUNJAB | 140401 | L3 | Rejected-Finance Being L3 | |
| 4 | L4₹16.7 L+₹3.5 L (26.0%)Rejected-Finance ASTBAL MOHALLA BANASAR BAGH ROAD PATIALA GATE SANGRUR 148001 | SANGRUR | SANGRUR | PUNJAB | 148001 | L4 | Rejected-Finance Being L4 | |
| 5 | L5₹21.0 L+₹7.7 L (57.7%)Rejected-Finance | L5 | Rejected-Finance Being L5 |
Tender Value
Refer Docs
EMD Value
₹66,000
Closing Date
26 Jul 2022, 6:00 pmClosed
Sh Himanshu, IDSE
MILITARY ENGINEER SERVICES GARRISON ENGINEER SOUTH TARAPORE ENCLAVE PATIALA CANTT
As per tender documents
2022_MES_533944_1
GE(S)/PAT/T-20/S/2022-23
Open Tender
Civil Works
Item Rate
180 days
Mil Stn Sangrur
Refer tender documents
8 documents required · 8 mandatory
₹500
Yes
GE (South) Patiala
₹66,000
Yes
27 Aug 2022
27 Jun 2022
29 Jul 2022
27 Jun 2022
26 Jul 2022
9 Jul 2022
27 Jun 2022 - 2 Jul 2022
Amount
Dismantling of ceiling fan 1200/1400 mm sweep, (any make and type , taking out rotor, removing all coils (burnt and alive), rewinding all the coils with suitable size super enamelled copper wire ISI marked including all packing materials, insulating materials, varnishing, greasing, oil, re-assembling, split pins, body/blade screws and testing on full speed, as per the direction of Engineer-in-Charge complete all as specified and directed.
All as per item No 1 here- in- before but exhaust fans up to and incl. 230/300 mm sweep.
All as per serial item No 1 here-in-before but exhaust fans of sweep more than 300 mm and upto 480 mm.
All as per serial item No 1 here-in-before but wall fans fans of sweep up to 450 mm.
Replacement of gun metal bush suitable for ceiling fans, exhaust fans and wall fans of any makes/size complete all as directed.
Replacement of ball bearing of suitable for ceiling fans/exhaust fans /wall fans of any size/make complete all as specified and directed.
Replacement of capacitor 2.5 mfd, 230 Volts + 5% dry type complete all as specified and directed.
All as per item No 07 here-in-before but 3.15 mfd.
All as per item No 07 here-in-before but 4 mfd.
Replacement of rubber reel, nut and bolts, spring washer, split pin for ceiling fans of any Make/Size, complete all as specified and directed.
S&F Fan regulator, electronic step type complete all as specified and directed.
Taking down ceiling fan /wall fans (any size, make, type) from any position, opening for and including greasing, cleaning, complete overhauling including split pins, body/blade screws , refixing in its original position and testing on full speed complete all as specified and directed incl provn of new cable flexible of copper conductor twin core, PVC insulated of size 23/.0076 ,750 mm long and one run of earth wire and tapping rubber insulating all as directed by Engineer-in-Charge.
Taking down exhaust fan (any size, make, type) from any position, opening for and including greasing, cleaning, complete overhauling including split pins, body/blade screws , refixing in its original position and testing on full speed complete all as specified and directed incl provn of new cable flexible of copper conductor twin core, PVC insulated of size 23/.0076 ,750 mm long and one run of earth wire and tapping rubber insulating all as directed by Engineer-in-Charge.
Replacement of ceiling fan blade (Set of 3) of 1200/1400 mm sweep ceiling fan including nuts, washers etc complete all as specified and directed suitable for any make of fan.( white colour)
All as per Serial item No 14 here-in-before but for 1400 mm sweep ceiling fan.
Turning,grinding and making good seat to ball bearing in proper position ( Ball bearing not included in this item )
Supply and connecting flexible copper wire Cable flexible of copper wire 0.5 sq mm (white clolour) complete.
Supply & fixing as in repair louvers made out of 0.63mm galvanised iron sheet for exhaust fan of any make and size upto 300mm all as directed by Engineer-in-Charge.
Supply & fixing as in repair louvers made out of 0.63mm galvanised iron sheet for exhaust fan of any make and size 380mm/450mm all as directed by Engineer-in-Charge.
Replacement of PVC canopy (upper/bottom) for ceiling fan of any make and size all as directed by Engineer-in-Charge.
Supply & fixing down rod for ceiling fans made out of MS pipe 15mm bore medium grade 45 cm long duly threaded, holes drilled and spray painted with synthetic enamel paint all as directed by Engr-in-Charge.
Spray painting on outside body of the ceiling fan incl blades any size with synthetic enamel paint (white colour) including scrapping existing paint and incl writing MES NO with black paint
Spray painting on outside body of the exhaust fan incl blades any size with synthetic enamel paint (smoke gray colour) including scrapping wxisting paint and incl writing MES NO with black paint.
M&L in replacement PVC flat twin core sheathed 1100 volts grade aluminium high quality cable of size 6 sqmm twin core.
M&L in replacement PVC flat twin core sheathed 1100 volts grade aluminium high quality cable of size 4 sqmm twin core.
M&L for PVC insulated unsheathed FRLS cables single core multi stranded copper conductor cable for repairs in existing conduits of size 2.5 sq mm as in replacement in burnt/defective circuits complete all as specified and directed.
Supply and fixing LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete including connecting to junction box and fixing of light fitting to existing GI bracket painted in silver colour & steel clamps complete with accessories suitable for fixing to the RCC LT Pole of 9 mtr complete all as specified and directed.
Supply and fixing LED street light fitting 60 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete including connecting to junction box and fixing of light fitting to existing GI bracket painted in silver colour & steel clamps complete with accessories suitable for fixing to the RCC LT Pole of 9 mtr complete all as specified and directed.
Supply and fixing LED street light fitting 90 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete including connecting to junction box and fixing of light fitting to existing GI bracket painted in silver colour & steel clamps complete with accessories suitable for fixing to the RCC LT Pole of 9 mtr complete all as specified and directed.
Supply and fixing LED flood light 70 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp complete with all accessories required for fixing arrangements all as specified and directed by the Engr-in-charge.
Supply and fixing LED flood light 100 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp complete with all accessories required for fixing arrangements all as specified and directed by the Engr-in-charge.
Supply and fixing post top lantern LED type 20 watt 230 watt volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp complete. and incl cost of masonary work for fixing of light on gate pillars on suitable size GI tubing duly silver painted incl colouring/white wash of masonary surface for matching of existing colour/surface all as specified & directed.
S&F Single Phase SMC Junction box suitable for mounting on LT RCC pole of 9 mtr long, box having Al busbar 20 Amp rating with 6 Amp MCB ('B' series) control, mounted on insulators with 2 clamps of copper strip for earthing of the armoured of the cable complete with making holes for connecting cables etc nuts bolts etc front openable hinged cover suitable for mounting on steel clamps nut bolt etc pvc adopters and PVC hose pipe upto cable trench for incoming and outgoing cables, factory made duly painted with powder coating process complete as specified and directed.
S&F DBs sheet metal enclosure 2 ways for fixing of SPN MCB on pole/wall mounting all as specified and directed.
S&F in replacement of MCB SPN 6-32 Amps 230 volts 'C' Series all as specified and directed.
M&L for servicing/repairing of solar street light fitting 12 V of 45 Watt all as specified and directed.
S&F Battery 12V suitable for solar street light fitting all as specified and directed.
M&L for fixing of GI pipe(light grade) bracket of 25 mm dia size of 1.2 mtr long bent to shape for fixing of LED street light fittings including fixing with steel clamps and accessories etc all as specified and directed.
M&L for fixing of GI pipe(light grade) bracket of 40 mm dia size of 1.2 mtr long bent to shape for fixing of LED street light fittings including fixing with steel clamps and accessories etc all as specified and directed.
M&L for fixing of GI pipe(light grade) bracket of 50 mm dia size of 1.2 mtr long bent to shape for fixing of LED street light fittings including fixing with steel clamps and accessories etc all as specified and directed.
Supply & Fix in replacement of PVC Conduit of size 20 mm incl all connected accessories (bends, clamps, PVC union & screws etc) incl disconnecting of existing calbes/wires from LED fitting/junction boxe and inserting the same in the conduits all as specified and directed.
Taking down carefully copper/ aluminium point wiring (light fan socket or power) complete along with fittings such as switches, ceiling roses, Pendants regulators Tube fittings and other Kits & fittings/conduit from surface /wall . Removing the material from work site and making good the disturbed portion/ surface of wall/ floor/ ceiling etc by using cement mortar and colour/ white wash to match with the existing surface / location. (Note :- Serviceable fitting / fixtures will be reused in the work as directed by Engineer- in-Charge)
Taking down un-serviceable main switch, DB’s insulators, DB for MCB etc of any type and any capacity and further disposal including making good the disturbed surface and matching the colour of wall with the existing colour wash / paint / distemper wherever required (as per the existing ) all as directed by Engineer-in-Charge.
Taking down ceiling fan of any descrptions, servicing and repairs of fans as required, fixing back, connecting and testing the fan for its satisfactory function including making good the disturbed surface and matching the colour of wall with the existing colour wash / paint / distemper wherever required (as per the existing ) all as directed by Engineer-in-Charge.
Taking down exhasust fan of any descrptions, servcing and repairs of fans as required, fixing back, connecting and testing the fan for its satisfactory function including making good the disturbed surface and matching the colour of wall with the existing colour wash / paint / distemper wherever required (as per the existing ) all as directed by Engineer-in-Charge.
Taking down elect water heater of any descrptions, servcing and repairs of geyser as required, fixing back, connecting and testing the geyser for its satisfactory function including making good the disturbed surface and matching the colour of wall with the existing colour wash / paint / distemper wherever required (as per the existing ) all as directed by Engineer-in-Charge.
M&L for point wiring with FRLS PVC insulated unsheathed multi-stranded copper conductor 1.5 Sq.mm (nominal area ) single core cable 1100 Volt grade drawn in and including rigid non metallic concealed PVC Conduit of suitable size (not less than 20 mm) on wall , surface of ceiling with all fittings, such as tee, bend, elbow, socket etc including pressed steel sunken boxes (Terminal boxes) with earth dolly,duly galvanised, with white shade frame & cover plate of suitable module for modular switch / or sockets including FRLS PVC insulated unsheathed stranded copper conductor 1.5 Sq.mm (nominal area ) single core cable as earth continuity conducter to common earth and connected to earth dolly, complete all as specified, for the following :-
One light/fan point controlled by one 1-way switch
One light point controlled by two 2-way switch
One 3/5 pin socket outlet, 5 Amp on independent board
One 3/5 pin socket outlet, 5 Amp on same board
One bell /buzzer point controlled by one push button on independent board
M&L for point wiring with FRLS PVC insulated unsheathed multi-stranded copper conductor 2.5 Sq.mm (nominal area ) single core cable 1100 Volt grade drawn in and including rigid non metallic concealed PVC Conduit on wall , surface of ceiling with all fittings, such as tee, bend, elbow, socket etc including pressed steel sunken boxes (Terminal boxes) with earth dolly,duly galvanised, with white shade frame & cover plate of suitable module for modular switch / or sockets including FRLS PVC insulated unsheathed stranded copper conductor 2.5 Sq.mm (nominal area ) single core cable as earth continuity conducter to common earth and connected to earth dolly, complete all as specified and directed by Engineer in Charge.
Dismantling/Taking down existing unserviceable sub main wiring from batten / conduit of any size all as directed. Removing the material from work site and making good the disturbed portion/ surface of wall/ floor/ ceiling etc by using cement mortar and colour/ white wash to match with the existing surface / location.
M &L for sub main surface wiring with PVC insulated unsheathed copper conductor cable of size 6 Sqmm single core through concealed rigid nonmetallic PVC conduit of suitable size (Not less than 25 mm dia) in wall and surface of ceiling including 6 Sqmm PVC insulated unsheathed copper conductor cable for continuous earthing form main earth dolly including making good the disturbed potion of wall. (Note :- Two run of 6 Sqmm copper cable one run of 6 Sqmm copper cable and PVC conduit will be measured as a single length)
Switch Modular type, 6 Amp, 240 Volts , one way complete fixed as in repair all as specified.
Switch Modular type, 6 Amp, 240 Volts , Two way complete fixed as in repair all as specified.
Switch Modular type, 16 Amp,240 Volts , one way complete fixed as in repair all as specified.
Socket outlet, Modular type, 6 Amp complete fixed as in repair all as specified.
Socket outlet, Modular type, 6&16 Amp complete fixed as in repair all as specified.
Bell Push, Modular type, 6 Amp complete fixed as in repair all as specified.
Fan regulator, modular type electronic step type complete fixed as in repair all as specified.
S&F ceiling rose surface bakelite two to three terminal 65x50 mm.
S&F in replacement Tube light fittings LED type 1x20 Watt 4 ft long incl LED tube rod and incl 3 core flexible wire 0.75 Sqmm copper cable all as specified & directed.
S&F in replacement Tube light fittings LED type 1X10 Watt, 2 ft long incl LED tube rod and incl 3 core flexible wire 0.75 Sqmm copper cable all as specified & directed.
Supply & fix LED bulk head ,10 W complete all as specified & directed.
S&F Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings complete all as directed.
S&F LED Bulb 9 watt 230 volt retrofit type complete all as directed.
S&F in bell ding dong operating on AC 230 volt single phase.
S&F MCB DB SPN 4 Way with acrylic double door complete all as specified and directed.
S&F MCB DB SPN 8 Way with acrylic double door complete all as specified and directed.
S&F including flushing in wall MCB distribution board vertical TPN 4 way 415 Volts AC double door type sheet steel phosphotised powder painted with bus bar neutral earth bar including provision of MCB TPN, FP 100 Amp conforing to IP 43 as incomer all as complete specified and directed.
S&F MCB 4 TPN 63 Amp 415 volt with breaking capacity of 16 KA complete all as specified and direceted.
S&F MCB 4 TPN 100 Amp 415 volt with breaking capacity of 16 KA complete all as specified and direceted.
S&F MCB SPN 240V 40 Amps C series 10 KA complete all as specified and direceted.
S&F MCB SP 240V 6 to 32 Amps C series 10 KA complete all as specified and direceted.
Taking Down the KWH meter along with wooden board/DB after removing all electrical connection complete all as directed by Engineer in Charge.
Refixing & connecting the same or new serviceable KWH energy meter after wiring complete all as directed by Engineer in Charge.
S&F Sheet metal enclosure factory made of size 20cm x 25cm x 12.5 cm deep box made out of 2mm thick ms sheet with double door with locking arrangement , epoxy power coated holes drilled for cable entries suitable for accomodating electric energy meter including brick/cement works as per site requirement includiing flushing the box in walll and making good the disturbed portion of wall /surface complete all as specified & directed by Engr in charge.
Taking down old U/S LT UG cable of any size from trenches/pipe/floor/walls complete all as specified.
Supply laying jointing aluminium service cable 10 sqmm 2 core fixing on wall/ducts etc including necessary fixing arrangement such as cable lugs glands etc complete after removing/taking out extg unsv cable to the entire satisfaction of Engr in Charge.
Supply laying jointing cable XLPE insulated PVC shetahted strip wire armoured 1100 volt 4 core 25 sqmm multi stranded aluminium conductor laid in trenches/wall/ducts etcincluding necessary fixing arrangement such as cable lugs glands etc complete after removing/taking out extg unsv cable to the entire satisfaction of Engr in Charge.
Excavation in trenches n.exc 1.5 mtr deep and n.exc 1.5 mtr wide getting out soil.
Returning filling in including spreading leveling, watering and well ramming in layers.
Removing excavated soil to a distance not exc. 50 mtr and depositing where directed.
Supply and spreading dry sand in trenches for cushioning of cable
Taking out Bricks from trenches complete all as specified & directed
Laying only old serviceable bricks obtained from item Sl no 82 above
Supply and laying well brunt bricks sub class ‘B’ of size 25 x 12.5 x 7.5 cm.
S&F GI Tube light grade 50 mm dia as in cable protection pipe complete all as specified & directed bby Engr in charge.
M&L for earthing complete with galvanised steel earth plate electrode 600x600x6mm thick buried directly in ground (earth pit not less than 2 mtr deep below ground level with top edgw of the plate not less than 1.4 mtr below normal ground level , connected earth wire 4 sqmm by means of bolts nuts check nuts and washers of galvanised iron or steel all as shown in electrical plate No 5 connected to earthing test point all as specified or indicated including PCC pit in PCC(1:3:6) type C-1 cast iron frame 50mm thick pre cast RCC(1: 1 1/2:3) nominal mix cover slab reinforced with 8 mm dia mild steel deformed bar 15cc and suitable handle of 10 mm Dia round bar including necesary excavation earth work in soft/loose soil and disposal of spoil to a distance n.exc 50m and funnel with watering pipe wire mesh copper lugs etc GI protection pipe of size 15 mm bore including testing complete all s specified & directed by Engr in Charge.
S&F Modular white cover plate with frame 1 module complete all s specified & directed by Engr in Charge.
S&F Modular white cover plate with frame 2 module complete all s specified & directed by Engr in Charge.
S&F Modular white cover plate with frame 3 module complete all s specified & directed by Engr in Charge.
S&F Modular white cover plate with frame 4 module complete all s specified & directed by Engr in Charge.
S&F Modular white cover plate with frame 8 module complete all s specified & directed by Engr in Charge.
S&F Modular metal flush box 1/2 module complete all s specified & directed by Engr in Charge.
S&F Modular metal flush box 3 module complete all s specified & directed by Engr in Charge.
S&F Modular metal flush box 4 module complete all s specified & directed by Engr in Charge.
S&F Modular metal flush box 8 module complete all s specified & directed by Engr in Charge.
S&F Modular white blank plate complete all as specified & directed by Engr in Charge.
Arun enterprises
gurchan singh & sons.
NARINDER KUMAR SONS
m/s s.n. builders
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .