Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹34.5 LAccepted-AOC E 84 OF HQ CWE NW MUMBAI AGE 87 1 3 GEETA NAGAR NAVY NAGAR COLABA MUMBAI 400 005 | MUMBAI | MAHARASHTRA | 400005 | ₹34.5 L | 1 | Accepted-AOC The lowest tenderer |
| 2 | 2₹36.9 L+₹2.4 L (6.90%)Rejected-Finance | ₹36.9 L+₹2.4 L (6.90%) | 2 | Rejected-Finance Not the lowest tenderer |
| 3 | 2₹43.2 L+₹8.7 L (25.1%)Rejected-Finance 1202 SAI PROVISO DHNISHT PLOT NO 72 73 SECTOR 20 KOPARKHAIRANE NAVI MUMBAI | THANE | MAHARASHTRA | 400601 | ₹43.2 L+₹8.7 L (25.1%) | 2 | Rejected-Finance Not the lowest tenderer |
| 4 | 3₹38.5 L+₹4.0 L (11.5%)Rejected-Finance | ₹38.5 L+₹4.0 L (11.5%) | 3 | Rejected-Finance Not the lowest tenderer |
| 5 | 5₹49.3 L+₹14.8 L (42.9%)Rejected-Finance | ₹49.3 L+₹14.8 L (42.9%) | 5 | Rejected-Finance Not the lowest tenderer |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
30 Dec 2019, 3:00 pmClosed
GE NW NAVY NAGAR
GE NW NAVY NAGAR COLABA MUMBAI DR HOMI BHABHA ROAD NAVY NAGAR COLABA MUMBAI
REPAIR REPLACEMENT OF UNSERVICEABLE LT PANEL LT UG CABLE AT RS AREA UNDER GE NW NAVY NAGAR COLABA MUMBAI
2019_MES_305066_1
8303/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE NW NAVY NAGAR
As per tender documents
7 documents required · 7 mandatory
₹500
Yes
GE NW NAVY NAGAR COLABA MUMBAI
₹80,000
14 Feb 2020
9 Dec 2019
31 Dec 2019
9 Dec 2019
30 Dec 2019
23 Dec 2019
9 Dec 2019 - 30 Dec 2019
Amount
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth and getting out for laying of HT cables, in any type of soil.
Returning filling in including spreading, leveling, watering and well ramming in layers not exceeding 25 cm with excavated soil all as specified and directed.
Removing excavated material out side MD land all as specified.
Supplying, filling, spreading, leveling in layers and well ramming dry river sand around cable in trenches for cable cushioning all as specified and directed.(Punned thickness shall be measured and paid)
Cutting existing road surface or hard standing,bituminous topping 15 cm but n exc 30cm. girth for laying of pipes/ cables and making good distrubed surface to match with existing complete.
Supply and laying un-reinforced precast concrete cable covers HV type 1, flat size 300mm x 180mm x 40 mm .
M&L for cement concrete type C-2, 1:3:6 (40mm graded stone aggregate), 75 mm thick for copping and finished surface.
M & L for 60 mm thick coloured interlocking paver tiles/ blocks, lacquer finish of size 250 X 250 mm, having compressive strength of 35N/Sqmm, zig-zag (uni-paver) shape in flooring tested as per IS : 15658-2006, with and including laying over 50 mm thick sand bed compacted complete as specified and directed.
Supply, Fixing, testing and commissioning of XLPE insulated armoured, heavy duty electric HT cable with aluminium conductor laid in trenches, fixed on wall, passing through pipes complete including connecting with MCCB/ busbar with the help of proper size thimble, glands, properly as directed by engineer-in-charge and taking out existing damaged unserviceable cable of following sizes :-
300 sq mm, 3 core
M&L for GI pipe ,heavy grade 100mm dia for road crossing of cable or for cable protection of cable above ground surface all as specified and directed.
Taking down existing old u/s ACB and supply, fixing, testing and commissioning air circuit breaker, 800 Amps, 50 kA, TP, horizontal draw-out type with trip free mechanism, O LED display + 4 nos auxlarry contact (2NO+2NC) + 01 nos fault trip indication + shunt trip coil + under voltage coil of 230V + inbuilt Mechanical & Electrical anti-pumping to prevent auto reclosing on fault, incuding material and labour for make arrengement and fabrication work for fixing of new ACB in existing panel consisting with copper busbar for 1600 A-1 set, Breaker control switch, CT of suitable capacity - 03 Nos, On/Off/Trip/R-Y-B indiacation, Make - L&T- Omega Cat No UW108NFD22410 and Legrand Cat No- DMX3 N 2500, 50 kA, 4P, 800A, frame-1, draw-out version or equivalent in Siemens, all as specified and as directed by Engr-in-Charge at site.The features of ACB's are as follows :-
Neutral protection settable 50-100 % of 'Ir'
Individual LED indication for faults (L,S,l,g).
Power Metering
Overload pre alarm and overload alarm at 0.9 Ir and 1.05 Ir.
Inbuilt thermal memory.
Over temperature protection to avoid heat generation at breaker termial with Pick up (Tp) 85 deg C to 115 deg C. Pre alarm of 0.5Tp to 0.95Tp in steps of 0.05Tp, Delay of 0 Min to 15 Mins in steps of 1 Min and Input supply of 24V DC.
Last 10 trip data for fault analysis
Last 20 Event Data for fault analysis
RS 485 communication compatibility.
Protection unit shall have Query, to store last trip information & shall have a back-up for at least 72 hours after the tripping occurred.
Drawout padlocking arrengement.
M&L for LT FPB, weather proof, vermin proof, both sidedouble door made out of 3mm thick CRCA sheet, CPRI approved, out-door type (IP-54) suitable for 3 phase, 4 wire, 415 volts, copper busbar strip with necessary clamps, nuts, bolts and washers, internally prewired with all connecting accessories, floor mounted type made with angle iron legs 40x40x4 mm thick, powder coated painting incl grouting, PCC work and foundation 60 cms above the ground level in PCC 1:3:6 type C2. all as specified & Directed consisting of following :-
S&F MCCB 400 Amps, 4 Pole, 36 kA, thermal magnetic release, Ics=100% Icu - 01 No, Cat No. CM98403OOROOG Make- L&T DN3B-400D and Cat No- 422007 of Make- Legrand or equivalent in Siemens.
S&F MCCB 100 Amps, 3 Pole, 25 kA, thermal magnetic release, Ics=100% Icu - 11 Nos, Cat No. CM90638OOLO of Make- L&T DN1-250C Cat No- 420045 of Make- Legrand or equivalent in Siemens.
Digital panel meter with LCD multifunction meter with CT/PT and all parameters as V,A,F,PF,KW,kVAR,kWH etc of make :- Legrand/Schneider/L&T/AE- 1 set.
Phase indicator lamp R,Y & B (Set of 3)- 01 Set
S&F Copper Bus bar 600 Amps of suitable size, all are in equal size - Set 1(R, Y, B, N). Note: All existing cable connections will be disconnected from old Panel carefully and re-connected with new Panel by providing glands and thimble all as directed by Engineer-in-Charge.
All as per Item No 12.00 above but comprising of the following :-
MCCB 320A, 36KA, FP withThermal magnetic release,lcs=100% lcs -01 Nos, Cat. No. CM98403OOROOG of Make- L&T DN3B-400D and Cat No- 422006 of Make- Legrand or equivalent in Siemens.
MCCB 100A, 25KA, 3P withThermal magnetic release,lcs=100% lcs -04 Nos, Cat No- 420045 of CM90638OOLO Make- L&T DN1-250C and Cat No- 420045 of Make- Legrand or equivalent in Siemens.
MCCB 63Amp,16KA,3P with Thermal magnetic release, lcs=100% lcs-04 Nos, Cat. No. CM91612OOJOOG Make- L&T DN0-100C and Cat No- 420003 of Make- Legrand or equivalent in Siemens.
Digital panel meter with LCD multifunction meter with CT/PT and all parameters as V,A,F,PF,KW,kVAR,kWH etc of make :- Legrand/Schneider/L&T/AE- 1 set.
Phase indicator lamp R,Y & B (Set of 3)- 01 Set
S&F Copper Bus bar 400Amps of suitable size, all are in equal size - Set(R,Y,B,N)
Supply, install, testing and commissioning of LT panel indoor type made out of 2 mm thick CRCA sheet weather, vermin proof factory fabricated, CPRI approved, front open hinged door with locking arrangement powder coated, individual compartment for MCCBs, indoor type suitable for 3 phase, 4 wire, 415 volts and 1600 Amps rated bus bar, top and bottom cable entry including disconnecting cable connections and fixing/connecting in new installed panel with provisions of thimble/lugs and necessary frame work and PCC foundation including shifting of existing panel if any making arrengement for fixing of panel and making good to disturbed surface as directed comprising of the following :-
S&F D/O DMX -SP ACB 1250 Amps, 4 Pole, 50 kA compact in size and mp2 release - 02 Nos, Cat No- UW112NFD22800 of Make- L&T and Cat No- 669545 of Make- Legrand or equivalent in Siemens.
S&F D/O DMX -SP ACB 630 Amps, 3 Pole, 50 kA compact in size and mp2 release - 01 No, Cat No- UW106NXD22800 of Make- L&T and Cat No- 669536 of Make- Legrand or equivalent in Siemens.
No LCD protection unit, LSIg Frame 1600/2000 -03 Nos, Cat No- 028168 of Make- Legrand or equivalent in Siemens/ Schneider.
Motor operator 220-250V A.C/D.C DMX2000 -03 Nos,Cat No- 028123 of Make- Legrand or equivalent in Siemens/Schneider.
Closing coil 220-250V A.C/D.C DMX2000 -03 Nos,Cat No- 028129 of Make- Legrand or equivalent in Siemens/Schneider.
Shunt trip 220-250V A.C/D.C DMX2000 -03 Nos,Cat No- 028134 of Make- Legrand or equivalent in Siemens/Schneider.
Under voltage release 220-250V A.C/D.C DMX2000 -03 Nos,Cat No- 028139 of Make- Legrand or equivalent in Siemens/Schneider.
S&F DPX3 630 - TM MCCB 400 Amps, 4 Pole, 36 kA - 03 Nos, Cat Cat No- CM98403OOROOG of Make- L&T DN3B-400D and No- 422007 of Make- Legrand or equivalent in Siemens.
S&F DPX3 630 - TM MCCB 320 Amps, 4 Pole, 36 kA - 04 Nos, Cat No- CM98403OOQOOG of Make- L&T DN3B-400D and Cat No- 422006 of Make- Legrand or equivalent in Siemens.
Vari-depth rotary handle for DPX3 630 -07 Nos, Cat No- 420163 of Make- L & T/ Legrand or equivalent in Siemens.
Spreader links set for FP DPX 400/630A -07 Nos, Cat No- 625008 of Make- L & T /Legrand or equivalent in Siemens.
S&F DPX3 250, MCCB 200 Amps 4P, 25 kA with Thermal magnetic release,lcs=100% lcs - 04 Nos, Cat No- CM90642OOPO of Make- L&T DN1-250C and Cat No- 420218 of Make- Legrand or equivalent in Siemens.
S&F DPX3 160, MCCB 100 Amps, 4 Pole, 16 kA withThermal magnetic release,lcs=100% lcs - 01 No, Cat No- CM90642OOMO of Make- L&T DN1-250C and Cat No- 420015 of Make- Legrand or equivalent in Siemens.
Vari-depth rotary handle for DPX3 160 & 250 -05 Nos, Cat No- 420161 of Make- L & T/ Legrand or equivalent in Siemens.
Spreader links set for FP DPX250ER/DPX250 -04 Nos, Cat No- 625018 of Make- L & T/Legrand or equivalent in Siemens.
Spreader links set for FP DPX160A -01 No, Cat No- 625006 of Make- L & T/ Legrand or equivalent in Siemens.
S&F Copper Bus bar 1600 Amps of suitable size, all are in equal size - Set 1(R, Y, B, N)
Phase indicator lamp R,Y & B (Set of 3)- 01 Set. Note: All existing cable connections will be disconnected from old Panel carefully and re-connected with new Panel by providing glands and thimble all as directed by Engineer-in-Charge.
M & L for earthing complete with galvanized steel earth plate electrode 600 X 600 X 6 mm thick buried directly in ground (earth pit not less than 2.25m deep below ground level) with top edge of the plate not less than 1.5m below normal ground level connected to galvanized earth strip 32 X 6mm by means of bolts, nuts and washers of galvanized iron or steel upto the test point all as shown in electrical plate No.3 of SSR Part-I connected toExisting earth strip including PCC earth pit with CI cover, GI funnel with wire mesh, GI protection pipe of 40 mm dia for earth lead and 20mm GI pipe for watering, excavation and earth work in any type of soil, filling the pit with charcoal and common salt surrounding the earth plate complete all as specified and directed by Engr-in-Charge including testing on completion.
M&L scrapping old worn out paint from complete outdoor panels and painting with one coat of synthetic enamel paint (incl front door in side and individual compartment outer side etc also) over a coat of primer and spray painting complete including fixing sticker danger sign board suitable for LT panel board all as specified and as directed by engr-in-charge.
M&L for shifting of LT panel of any size with all accessories and fixing it to other location as directed by Engr-in-Charge at site, connecting cable connection with connecting accessories, including foundation in PCC 1:3:6 type C2 and fittings as required all as specified and directed.
Ashish Enterprises
ORIENT ELECTRIC CO
ASHOK ENTERPRISES
DHARMESH ENTERPRISES
Shree Ayyappa Engineering
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .