| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.8 LAccepted-AOC | L1 | Accepted-AOC 1st lowest rate | |
| 2 | L2₹5.8 L+₹3,411.44 (0.59%)Rejected-Finance | L2 | Rejected-Finance 2nd lowest rate | |
| 3 | L3₹5.8 L+₹3,762.46 (0.65%)Rejected-Finance | L3 | Rejected-Finance 3rd lowest rate | |
| 4 | L4₹5.8 L+₹3,880.11 (0.67%)Rejected-Finance WEST BENGAL | MURSHIDABAD | WEST BENGAL | 742163 | L4 | Rejected-Finance 4th lowest rate |
Tender Value
Refer Docs
EMD Value
₹11,589
Closing Date
2 Mar 2024, 4:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Addl. District Magistrate, Uttar Dinajpur
office of the District Magistrate, Uttar Dinajpur
204 /Planning_Dev
2024_DMUD_674270_1
204 /Planning_Dev
Open Tender
CIVIL WORKS
Item Rate
30 days
Kaliyaganj
Please refer Tender documents.
4 documents required · 4 mandatory
₹0
₹11,589
23 Oct 2024
24 Feb 2024
4 Mar 2025
24 Feb 2024
2 Mar 2024
24 Feb 2024
Amount
Labour for boring of tubewell of required diameter by water jet system through any type of soil strata including hiring and labour charges for boring pipes, scaffolding, tools and plants as necessary and taking them out and lowering pipes, strainers, blind pipes etc, and fitting fixing the same complete including bucket washing and other incidental works in connection. The tubewell should have aminimum gap 50mm in between the outside of the tubewell pipe and the bore. (a)For depth upto 150metre for 40mm dia tubewell with top enlargement of 80mm dia.(i) 50 mm dia. boring etc.
Labour for boring of tubewell of required diameter by water jet system through any type of soil strata including hiring and labour charges for boring pipes, scaffolding, tools and plants as necessary and taking them out and lowering pipes, strainers, blind pipes etc, and fitting fixing the same complete including bucket washing and other incidental works in connection. The tubewell should have aminimum gap 50mm in between the outside of the tubewell pipe and the bore. (a)For depth upto 150metre for 40mm dia tubewell with top enlargement of 80mm dia.(ii) 100 mm dia boring etc. top enlargement.
Supplying high density polythene strainer of approved make with adaptor confirming to I.S. specifications. (i) 50 mm dia. (2Nos @ 1.83M each)
Supplying fitting fixing steel cutter piece upto 450mm long with sockets (i) 50mm dia.
Supplying PVC rigid pipes & fittings (medium duty) confirming to ASTMD-1785 & threadede to match with GI-pipes as per IS:1239(Part-I) (i) 40 mm dia. (Delivery Pipe)
(ii) 50 mm dia. (Well Pipe)
(iii) 100 mm dia. (Casing Pipe)
Supplying, fitting and fixing PVC pipes of approved make of Schedule 80 (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew,reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, making threads,fitting, fixing etc.complete in all respect including cost of all necessary fittings as required,jointing materials and two coats of painting with approved paint in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials. Payment for painting will be made seperately) (a) For Exposed Work PVC, Pipes ..... 40mm dia.
32mm dia
Supplying, fitting and fixing bib cock or stop cock. (ii) Chromium plated Bib Cock long body with wall flange with aerator (Equivalent to Code No. 512 & Model - Tropical / Sumthing Special of ESSCO or similar brand)
Supplying P.V.C. water storage tank of approved quality with closed top with lid (Black) - Multilayer,(d)1500 litre capacity
Labour for hoisting plastic water storage tank. (i) Upto 1500 litre capacity. (a) Upto 1st story from G.L.
Labour for punching hole in plastic water storage tank upto 50 mm dia
Labour for lowering plastic water storage tank and stacking in places as directed. (i) Upto 1500 litre capacity (a) From 1st floor to G.L.
Installation of 2 H.P. capacity A.C.submerssible pump in the same bore of approved brand whose output is not less than 2000 Ltr/hours at 40 Mtr. head including supply of all necessary materials of approved quality, labour etc. with all allied works as per direction of the E.I.C. [A.C.Submerssible Pump and controller should carry a warranty of 1 year directly from the manufacturers] quoted rate
washing and developing tube well with air compressor pump and engine forn8(eight)nhours continuous pumping per day with necessary arrangements forntesting the yield in per hour with 'V' notch including hire and labour charges for all tools and plants and scaffolding as required.
Supplying, fitting and fixing 300mm M.S. clamp of approved quality.
Display Board
Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) …..levelling, dressing and ramming the bottom, bailing out water as required complete.
Earth work in filling in foundation trenches or plinth with good earth, in layers not exceeding 150 mm. including ..(a) With earth obtained from excavation of foundation.
ii)Filling in foundation or plinth by Silver sand in layers …..incl. the cost of sand.
Cement concrete with graded stone ballast (40 mm. size) excluding shuttering. (A) In ground floor (Pakur Variety stone metal ) (a) 6:3:1 proportion
(A) Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement if any, in ground floor as per relevant IS codes. with Pakur Variety
(A)Hire and labour charges for shuttering with centering and necessary staging unto 4 m. using approved stout props and thick hard wood plants of approved thickness lintel cured or straight including fitting. Fixing and striking out after completion of works (unto roof of ground floor) (c) 25 to 30 mm wooden planks shuttering. In Ground Floor
(A) Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups,binders etc. ... rust (if necessary), cutting to requisite length, hooking and bending to correct shape,placing in proper position and binding with 16 gauge black annealed wire at every inter-section, complete as per drawing and direction.Other than TATA/RNRL/SAIL In Ground Floor
(A)Plaster ( to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints or roughening of concrete surface, including threading. Nosing and drip course where necessary (G. floor) (i) With 6:1 cement mortar (a) 20 mm. thick plaster
INSTALLATION OF 1 NO. SOLAR SUBMERSIBLE PUMP BORING --Labour for boring tube well of required dia. by water jet system through any type of soil strata including hire and labour charges for boring pipes, scaffolding, tools and plants as necessary and taking out them and lowering pipes, strainers, blind pipe etc. and fitting and fixing the same complete including bucket washing and other incidental works in the connection. The tube well should have a minimum 50 mm gap in between the outside of the tubewell pipe and the bore.(a) For Depth upto 150 mtr for 40 mm diameter Tubewell with Top Enlargement of 100 mm diameter....(i) 40 mm diameter.
(ii) 100 mm diameter.
Supply of PVC pipes & fittings schedule -80 (medium duty) conforming to ASTMD -1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). ...(a) 100 mm dia.
(b) 40 mm dia.
(c) Reducing socket ( 100 mm X 40 mm).
Supplying PVC strainer of approved make with adapter conforming to I.S. 12818 specifications.(i) 40 mm dia.
Supplying , fitting and fixing Steel Cutter piece upto 450 mm long with Sockets....(i) 40 mm dia.
Supplying, fitting and fixing G.I. cap at top.(i) 100 mm dia
Supplying medium sand for shrouding, Finess Modulus 1.80 to 2.00.
Supplying, fitting and fixing PVC pipes of approved make of Schedule 80 (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, making threads,fitting, fixing etc. complete in all respect including cost of all necessary fittings as required,jointing materials and two coats of painting with approved paint in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials. Payment for painting will be made seperately)...32 mm dia
25 mm dia
Supplying, fitting and fixing bib cock or stop cock..15 mm. Dia
25 mm Dia
Construction of circular soak well 2.5 metre deep in all types of sandy soils with dry brick work upto 1.6 metre from the bottom having 150 mm ntermediate cement brick work (1:4) band all round and cement brick work (1:4) upto 0.90 metre from top with 20mm thick cement plastering (1:4) to inside face upto the depth of cement brick work, 15mm thick cement plaster (1:4) on outer face from top of the well upto G.L. and 6 mm thick cement plaster (1:4) on top of the R.C.C. cover slab including filling bottom 1.00 metre of inside of the well with brick metal (50 mm to 63 mm size) including R.C.C. cover slab of 100 mm thick with cement conc (1:1.5:3) with stone chips with necessary reinforcement and shuttering including one 560 mm dia. R.C.C. manhole cover (heavy type)of approved make supplied, fitted and fixed in the cover slab with necessary fittings, making nacessary arrangements for pipe connections, excavation of well including shoring, dewatering and removing the exess earth from the premises as per direction complete in all respect with all costs of labour and materials. With 250 mm thick dry brick work and 250 mm thick cement brick work (1:6) and 1.00m inside dia. For - JSW/ JSPL/ SHYAM/ SRMB/ BMASL/ ELECTRO STEEL/ SSL
Local Market Rate / Supply, delivery & installation of 900 watt peak capacity Solar photovaltatic array along with 1.00 H.P. capacity D.C./ A.C. submerssible pump in the same bore (designed to use with Solar Power) of approved brand whose output is not less than 2000 Ltr/hours at 40 Mtr. head including supply of all necessary materials (Hanging pipe, Copper weir for supporting to hang the Submersible etc.) of approved quality, labour etc. with all allied works as per direction of the E.I.C. [D.C./ A.C. Submerssible Pump and controller should carry a warranty of 1 year directly from the manufacturers]
Local Market Rate / Installation of Solar photovaltatic array Panels on the structure as per standard & approved drawing which will grouted either ground based by construction of foundation concrete or integrated with the staging steel structure of water tank. The Solar Panels will then be connected to the Pump Controller which in turn will be connected to the pump as well as the level indicator of the water tank as per direction of the E.I.C. [Steel structure of water tank and Solar Pannel which components will be Galvanized on MS are carry a warranty of 5 years and Solar Panels will also carriy a warranty as per attached technical specs]
Local Market Rate / Installation of Iron Removal Unit which does not use electricity attached with the water tank. The Iron Removal Unit must have the approved quality/ brand whose capacity of oxidation filter is not less than 200 Ltr/ hours. etc. with all allied works as per direction of the E.I.C.
INSTALATION OF PVC WATER TANK OVER STEEL FABRICATED STRUCTURE WITH NECESSARY PLUMBIBNG WORKS
Providing & fixing Concrete Sign Board as per IRC specification of size 900 x 750 x 37 mm. thick made with RCC 1:1½:3 with pakur variety stone chips reinforced with double layer IRC febric (75 x 75 mm. mesh) and fixed with necessary nuts & bolts on two RC precast posts 100 mm. x 150 mm. of height 2.65 m. of which top 750 mm. is of section 100 x 13 mm. and 1.90 metre above GL & 0.75 metre below GL including digging hole, repacking the same with cement concrete 1:3:6 with jhama khoa or with local stone chips etc. complete including painting two coats on both faces lettering sign marks etc. as per direction of the Engineer-in-Charge. (The rate is inclusive of cost of reinforcement, concrete, shuttering, nuts & bolts, washer etc. complete.)
SHIV SHAKTI ENGINEERING WORKS
Balihara Co. Op. Labour Cont. and Const. Soc. Ltd.
Azad Construction
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .