Executive Engineer TLMD-II, JKPTCL, Glad
Office of Executive Engineer TLMD-II, JKPTCL, Gladni Jammu
Supply, Installation, Testing and Commissioning of 132KV CT Set for 400MVA Transformer and 11KV NCT set for 160MVA and 400MVA Transformers after replacement of said old/ worn out equipments at 710 MVA, 220/132/33 KV Grid Station, Gladni
2023_PDD_216505_1
TLMD-II/J/10 of 2023-24 Dated 13-06-2023
Open Tender
Electrical and Maintenance Works
Turn-key
90 days
GLADNI JAMMU
AS PER NIT AND SBD
3 documents required · 3 mandatory
₹1,000
Executive Engineer, TLMD-II, JKPTCL, Gladni Jammu
₹30,680
20 Oct 2023
13 Jun 2023
23 Aug 2023
15 Jun 2023
19 Aug 2023
16 Jun 2023
Amount
Design, Engineering, Manufacture, workshop testing, Supply including packing and forwarding, transportation, delivery at site, site storage charges of :-
Single phase, 50 c/s 145KV Current Transformers (including first fill of transformer oil plus 10% extra and all accessories including terminal connectors / clamps suitable for single / twin moose conductor as per site requirement, auxiliaries, etc complete in all respects as specified in technical specifications), 5-core, Ratio - 2000-1600-1200/1-1-1-1-1 A, 31.5 KA for one second, rated dynamic current 100KA (peak), Class A insulation, Burden 20 VA
11KV NCT for 400 MVA and / or 160 MVA Auto transformers and one spare piece; Specification :- Three core, Live tank type, Neutral Current Transformer with Porcelain insulators having creepage distance of 25mm / KV; Ratio: 2000-1600-1200/1-1-1 A with following technical specifications:- 12KV, OUTDOOR TYPE, OIL COOLED HT NEUTRAL CURRENT TRANSFORMER, CTR: 2000-1600-1200 / 1-1-1A, Class: PS, Vk >= 2000 V at Highest tap, Rct <= 2.5 Ohms, Imag= 30mA @Vk/2. Insulation Level: 12/28/75kVp. Insulation Class: “A”, Winding Material: Copper.
Handling, Storage, Preservation, Dismantling of old Equipment and is carriage back to Divisional Stores, Erection (except Civil works), Testing and Commissioning of new supplied Equipments
Single phase, 50 c/s 145KV Current Transformers (including first fill of transformer oil plus 10% extra and all accessories including terminal connectors / clamps suitable for single / twin moose conductor as per site requirement, auxiliaries, etc complete in all respects as specified in technical specifications), 5-core, Ratio - 2000-1600-1200/1-1-1-1-1 A, 31.5 KA for one second, rated dynamic current 100KA (peak), Class A insulation, Burden 20 VA
11KV NCT for 400 MVA and / or 160 MVA Auto transformers and one spare piece; Specification :- Three core, Live tank type, Neutral Current Transformer with Porcelain insulators having creepage distance of 25mm / KV; Ratio: 2000-1600-1200/1-1-1 A with following technical specifications:- 12KV, OUTDOOR TYPE, OIL COOLED HT NEUTRAL CURRENT TRANSFORMER, CTR: 2000-1600-1200 / 1-1-1A, Class: PS, Vk >= 2000 V at Highest tap, Rct <= 2.5 Ohms, Imag= 30mA @Vk/2. Insulation Level: 12/28/75kVp. Insulation Class: “A”, Winding Material: Copper.
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .