Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Rejected-Technical | Rejected-Technical Technically not Qualified |
| 4 | Rejected-Technical | Rejected-Technical Technically not Qualified |
Tender Value
₹12.6 L
EMD Value
₹25,150
Closing Date
14 Jun 2022, 3:00 pmClosed
Executive Engineer (CD-I)
Room No. 10, Engineers Complex, near Main Gate Horticulture Nursery, IIT Campus 110016
Making prefabricated temporary cabins (02nos.) at rooftop of MS Building and R.I. Park for setup of end stations in JATC projects at IIT Delhi.
2022_IIT_692672_1
IITD/ WORKS(SP-3895)/2022
Open Tender
Miscellaneous Works
Works
60 days
Indian Institute of Technology Delhi
Please refer Tender documents.
5 documents required · 5 mandatory
₹500
Registrar IIT Delhi
₹25,150
28 Jun 2022
3 Jun 2022
15 Jun 2022
3 Jun 2022
14 Jun 2022
3 Jun 2022
Amount
A) Civil Work
1) Providing and fixing of customized 50mm thick PPGI Puff panel for wall ( Sandwiched with high density polyuretharene foam in betweem two pre painted galvanised iron sheet panel made of 0.50mm thick JSW sheet 40+/- 2kg/cubic meter density as per Manufacturer specifications) and fixing door of size 2.10x0.90 mtr with the same material as of wall including all fittings & fixtures for locking arrangement and including making provision for opening for doors, windows, venilators. electrical conduits, switch boards etc and cutting to size and shape wherever required complete in all respect at all level including loading unloading and cost of frame structue support of wall etc. as per direction of Engineer-In-Charge. ( Note :- Rates are inclusive of GST, all taxes & cartage etc. and the payment shall be made based on the actual exposed finish area (one side only) of the panel with reduction of opening of door/ window / ventilator)
1.1) 50mm thick PPGI Puff panel for wall
1.2) Providing and fixing customized 40/63mm thick corrugated PPGI Puff panel for roof ( Sandwiched with high density polyuretharene foam in betweem two pre painted galvanised iron sheet panel made of 0.50mm thick JSW sheet 40+/- 2kg/cubic meter density as per Manufacturer specifications) with proper roof slope including necessary fittings & fixtures and cutting to size and shape wherever required complete in all respect at all level including loading unloading and cost of frame structue support of roof purlins, rafters and trusses etc. as per direction of Engineer-In-Charge . ( Note :- Rates are inclusive of GST, all taxes & cartage etc and the payment shall be made based on the actual exposed finish area (one side only) of the panel.)
1.2.1) 40/63mm thick corrugated PPGI Puff panel for roof
2) STEEL WORK
2.1) Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.
2.1.1) Hot finished welded type tubes
2.2) Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.
2.2.1) In stringers, treads, landings etc. of stair cases, including use of chequered plate wherever required, all complete
3) ALUMINIUM WORK
3.1) Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :
3.1.1) For fixed portion
3.1.1.1) Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15)
3.2) For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately)
3.2.1) Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15)
3.3) Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):
3.3.1) With float glass panes of 8 mm thickness (weight not less than 20 kg/sqm)
3.4) Providing and fixing anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineer-in-charge. (Only weight of grill to be measured for payment).
4) WOOD AND P.V.C. WORK
4.1) Providing and fixing 18mm thick commercial ply wood sheet (ISI marked) Over frame work of cabin floor and platform including necessary glue and nails etc. complete as per directions of Engineer-in-charge.
4.2) Providing and fixing homogeneous polyvinile chloride sheet/tile of approved colour and shade, in flooring and skirting in approved pattern on a smooth and damp proof base using rubber based adhesive of approved quality and manufacturer like fevicol SR 998 or equivalent including rolling with light wooden roller weighing about 5 kg. all complete as directed by Engineer-in-charge.
4.2.1) 2mm thick Sheet
4.3) Providing and fixing roller blinds, the febric should be scren openness of 5% and composition of 75% PVC 25% polyster with fabric weight of 465 GSM with fre resistance grade of NSPA 701, BS 586 part-II with anodized aluminium channel weight, bracket and hangers etc. the fabric will be approved colour and hed of approved manufacturer complete. Make( Vista/Mac/Marvel)
4.4) Providing & fixing sliding wheel roller set of approved make or equivalent in aluminium sliding window shutters for opening and closing as per direction of Engineer-in-charge.
4.5) Providing & fixing crescent lock of approved make or equivalent in aluminium sliding window shutters for opening and closing as per direction of Engineer-in-charge.
5) DISMANTLING AND DEMOLISHING
5.1) Dismantling steel work in built up sections in angles, tees, flats and channels including all gusset plates, bolts, nuts, cutting rivets, welding etc. including dismembering and stacking within 50 metres lead
B) ELECTRICAL WORK
1) Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.
(a) Group C
2) Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.
(a)Group C
3) Wiring for light/ power plug with 2X4 sq.mmFRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit along with 1 No 4 sq.mm FRLS PVC insulated copper conductor single core cable for loop earthing as reqd.
4) Wiring for light/ power plug with 4X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit alongwith 2 Nos. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
5) Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required
(a) 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
(b) 2 X 6 sq. mm + 1 X 6 sq. mm earth wire
(c ) 2 X 10 sq. mm + 1 X 6 sq. mm earth wire
(d ) 4 X 6 sq. mm + 2 X 6 sq. mm earth wire
6) Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required.
(a) 2 Pair
7) Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
(a) 15/16 A switch
(b) 6 pin 15/16 A socket outlet
(c ) Telephone socket outlet
8) Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
9) Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.
(a) 1 or 2 Module (75mmX75mm)
(b) 12 Module (200mmX150mm)
10) Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.
11) Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
(a) 16 way, Double door
12) Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
(a) Single pole
13) Supplying and fixing following rating, double pole, 240 volts, MCB in the existing MCB DB complete with connections, testing and commissioning etc. as required.
14) Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 A, “C” curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
15) Providing and fixing M.S. Fan clamp type I or II of 16 mm dia M.S. bar, bent to shape with hooked ends in R.C.C. slabs or beams during laying, including painting the exposed portion of loop, all as per standard design complete as required. Rate to be taken
16) MAINTENANCE FREE ADVANCE CHEMICAL GEL EARTHING SYSTEM.
(a) Supply, Making, Testing & Commissioning of advance maintenance free Chemical Gel Earthing of Single Pipe Technology (Copper) of 3mtr long 50mm dia filled with highly conducting metallic compounds with the permenant sealings at the both the ends with the lead terminal 32x10mm at the top along with 50 Kgs of chemicals Gel for (mixture of Sulphate, Silica, Alumina, Iron Oxide, Titanium Oxide, Calcium Oxide, Potassium Oxide, Chloride, Nickel Oxide, Magnesium Oxide, Sodium Oxide, Zinc Oxide, etc) Resistance Lowering Grounding Minerals. The loss on ignition by mass of the chemical compound RESLOW shall be less than 20%. The chemical compound should be tested and certified by any International accredited and BIS (Bureau of Indian Standards) accredited laboratory. The chemical earth electrode manufacturer shall be an ISO 9001:2008 & ISO 14001:2004 certified organization.
(b) The testing laboratory should be ISO 9001 & ISO 14001 certified. The JK CHEMRODE shall be be duly tested & certified by CPRI (Central Power Research Institute), Govt of India for a minimum short circuit current of 30 KA rms. The chemical earth electrode manufacturer shall be an ISO 9001:2008 & ISO 14001:2004 certified organization.
(c ) Supply & Installation of Heavy duty polyplastic weather proof earth pit / chamber.
17.) Providing and fixing 25 mm X 5 mm copper strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required.
18) Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required.
19) Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed steel/ PVC conduit as required. (Make: Havells/ Beldon/ D-Link/ Polycab)
(a) 1 run of Cable
20) Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
21) Information socket - category 6-UTP - 1 module (Make: Legrand)
22) Supplying ,installation, testing and commissioning of surface mounting LED luminaire equipped with CRCA powder coating housing, anti glare polycarbonate diffuser with energy efficient electronic driver with following features:- suitable for operation voltage and frequency: 130-300 V AC, 50 Hz ; wattage not more then 36 watts, Output lumens not less then 36001m; CCT not less then 6500K; Dimension in mm (595x595); Normal surge protection 2.5kV; power factor not less then 0.9; Minimum IP protection 20. (Make : Philips/ Wipro/ Havells)
23) S/I/T/C of 1200 mm size sweep, BEE 5 star rated ceiling fan with Brush less Direct Current (BLDC) motor, class of insulation : b, 3 nos blades, 30cm long down rod, 2 no canopies, shackle kit, safety rope, copper winding, power factor not less than 0.9, Service value (CMM/W) minimum 6.85 Air delivery minimum 215 CMM, 350 RPM (tolarance as per IS : 374-2019), THD less than 10%,remote or electronic regulator unit speed control and all remaining accessories including safety pin, nut bolts,washers, temperature rise=75 degree C (max), insulation resistance more than 2 mega ohm, suitable for 230 volt,50 Hz single phase AC supply system, earthing etc complete as required. Make havells/Atomberg/Orient/Crompton.
24) S/I/T/C 1.5 TR Split type AC fitted with rotary compressor rated cooling capacity nominal (Kcal/Hr) : 4500 Min. cooling cap (Min) guaranteed (Kcal/Hr) : 4275 Min Room discharge Air flow (cum.m/h) 700 EER-(W/W) 3.30 minimum star rating : 5 Star With following items :- 1. Suction line copper -06 mtr 2. Liquid line copper pipe -06 mtr 3. Expanded polyethylene foam insulation, tubing for suction line copper pipe-06 mtr 4. Drain pipe-05 mtr 5. Suitable capacity 3 core FRLS PVC insulated copper wire to electricity connect both the units with each other-06 mtr. 6. Condensing unit charged with sufficient quantity of Refrigerant Suitable for 230 Volt,50 Hz AC supply system i/c installation of condenser unit,installation of evaporator (cooling) unit,making suitable opening the wall for drawing of refrigent pipes,power supply to indoor and outdoor units,wrapping the refrigent pipes with foam/polyurithene insulation.Pressure testing in the pipe line with dry nitrogen gas as and when required, reparing of any leakage in the pipe line etc as required. (i) Mounting and Fitting of indoor and outdoor units at their respective location. (ii) Laying Refrigerent pipe lines (both) 6.0 mtr for connection both the units after drilling holes in the wall, if required thickness of the pipe shall not be less than 0.80mm i/c six meter of 3 core PVC wire. (iii) Providing and Insulation the suction pipe line with expanded Polyethylene foam/Tubing and covered with PVC flexible pipe. (iv) Providing and laying drain pipe to throw out the condenser wayter being formed in the indoor unit. (v) Providing and Charging Refrigerant gas in the unit etc as required.
25) Supplying and laying of additional copper refrigerant pipe line [ suction and discharge both] including providing foam / polyurithene insulation on both the refrigerant pipes separately along with necessary brazing, leak testing, etc. as required.(Extra Refrigerant pipe lines (both) beyond 6.0 Meter for connection both the units after drilling holes in the wall,if required thickness of the pipe shall not be less than 0.80mm i/c three core PVC wire 80/0.20 and drain pipe to throw out the condensate water being formed in the indoor unit and covered with 2" PVC flexible pipe with clamp on outer side and bends onlyetc as required.)
M/S BINDRA AND SONS
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .