SUPERINTENDING ENGINEER
SE, EDC-1, Meerut
ETN0-83/EDC-MT/2024-2025
2024_PVVNL_982364_1
ETNo.83/EDC-MT/2024-25
Open Tender
Electrical Works
Lump-sum
180 days
Under EDD-3
ETN0-83/EDC-MT/2024-2025
2 documents required · 2 mandatory
₹3,540
SUPERINTENDING ENGINEER
₹12,500
2 Jan 2025
10 Dec 2024
23 Dec 2024
10 Dec 2024
23 Dec 2024
10 Dec 2024
Amount
Safe Carriage of following material from store center PVVNL to site & vice-versa of work including loading & unloading at both ends maximum distance up to 100 Km. :-
PCC Pole 8.5 Mtr Long/STP Pole 11 Mtr. Long.
Line material such as 11 KV Cross arms 11 KV pin, 11 KV pin insulator, 11 KV Disc, Stay rod, Stay wire ACSR weasel conductor, GI Wire, MS angle iron & MS Channel, TPMO, Fuse set etc.
10 KVA to 250 KVA T/F including complete related material required for transformer.
LT Lead
Metering cubical
CT/PT Unit
XLPE Cable of size 3x70/3x120 sq.mm
Erection of PCC pole 8.5 Mtr long/STP Pole 11 mtr long after digging a pit of size 1.6 mtr deep in all type of Soil including grouting ratio (1:4:8) & back filling of the pole with proper ramming after completion of work. (as per UPPCL Respo)
Fabrication and fixing of all 11 KV HT/LT line accessories. (as per UPPCL Respo)
Erection of Double pole on PCC pole 8.5 mtr after digging a pit of size1.6 mtr deep in all type of Soil for each pole including grouting & back filling of the pole with proper ramming after completion of work. (as per UPPCL Respo)
Fabrication and fixing of MS angle and MS channel, fixing all 11 KV accessories TPMO, Fuse set 11 KV pin insulators on D/P Pole. (as per UPPCL Respo)
Mounting of 10to 100 KVA T/F with proper jumpering of HT side and fixing of cable on LT side of T/F. (as per UPPCL Respo)
Making a section pole to exist pole after fabrication & fixing of T-channel fixing of all 11 KV accessories. (as per UPPCL Respo)
Erection of stay rod complete after digging a pit of size 1.6 mtr deep and grouting the same in block of size 0.60 x 0.60 x 0.30 mtr and nuzzling at the both ends and filling the pit with excavated earth soil with proper ramming.
Laying lifting stringing & proper sagging of ACSR weasel conductor for 3 phase, 3 wire 11 KV line including binding & jumpering properly. (as per UPPCL Respo).
Laying of LT ABC Cable of various size including fixing of all LT ABC accessories on support (as per UPPCL Respo).
Fixing of Distribution box including fixing the cable from transformar and consumer service cable (as per UPPCL Respo).
Earthing of each 11 KV line pole & T/F properly after drive of electrodes if size 20mm x 250 mm and connection the earthing point with GL wire. (as per UPPCL Respo).
Guarding of line with G.I. wire having 2 no. horizontal wire & 3 Mtr distance of SWG G.I. wire after fabrication of guard cross arms of & fixing the same in supports. (as per UPPCL Respo).
Filling of 11 KV Jointing Kit Indoor/Outdoor of size 3x70/3x120 sq.mm (as per UPPCL Respo).
Laying of XLPE Cable of size 3x70/3x120 sq.mm pit of the size 1.5 in the trench and road crossing in the air (as per UPPCL Respo).
Providing and Fixing of Tailless Unit for 250 KVA T/F (as per UPPCL Respo).
Making of New 250 KVA T/F Plinth of size 6'x6'x3' (feet) & installation of 250 KVA T/F. (as per UPPCL Respo).
New Wiremesh Fencing of 250 KVA T/F 18x12x6 (as per UPPCL Respo).
Chemical Earthing for 250 KVA T/F (as per UPPCL Respo).
Mounting and installation of CT/PT Unit. (As Per Direction of Supervising Engineer).
Mounting of fixing of metering cubical (As Per Direction of Supervising Engineer).
Providing and fixing of Holding clamp. (As Per Direction of Supervising Engineer).
Providing and fixing of LT Clamp. (As Per Direction of Supervising Engineer).
Providing and fixing of J Hook. (As Per Direction of Supervising Engineer).
Providing and fixing of Piercing Clamp. (As Per Direction of Supervising Engineer).
Providing and fixing of Dead and clamp. (As Per Direction of Supervising Engineer).
Providing and fixing of MS Nut and bolts (As Per Direction of Supervising Engineer).
Providing and fixing of LT Insulator. (As Per Direction of Supervising Engineer).
Cutting & chopping tree branches near side of line for making the clearance between line and tree.
Hi-tech power transmission (BID ID -4806957)
SHASHI ENTERPRISES (BID ID -4807059)
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .