Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.8 LAccepted-AOC | L1 | Accepted-AOC Tender AoC | |
| 2 | L2₹21.3 L+₹2.7 L (14.6%)Rejected-Finance | L2 | Rejected-Finance Being L2 | |
| 3 | L3₹21.8 L+₹3.2 L (17.3%)Rejected-Finance | L3 | Rejected-Finance Being L3 | |
| 4 | L4₹24.9 L+₹6.3 L (33.8%)Rejected-Finance | L4 | Rejected-Finance Being L4 | |
| 5 | L5₹25.0 L+₹6.4 L (34.2%)Rejected-Finance | L5 | Rejected-Finance Being L5 |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
14 Mar 2023, 6:00 pmClosed
GE West Hisar
GE West Hisar Hisar Mil Stn-125006
REPAIR, SERVICING AND REWINDING OF PUMPS AND MOTORS INCLUDING OTHER ALLIED WORKS AT HISAR MIL STN UNDER GE (WEST) HISAR
2023_MES_582047_1
GE(W)/HSR-74/2022-23
Open Tender
Civil Works
Item Rate
180 days
Hisar Mil Stn
As per tender documents
7 documents required · 7 mandatory
₹500
GE West Hisar
₹60,000
Yes
30 Mar 2023
21 Feb 2023
16 Mar 2023
21 Feb 2023
14 Mar 2023
7 Mar 2023
Amount
Disconnecting/dismantling from foundation and existing pipe line and taking up of defective vertical turbine motor and pump assembly of capacity 75 HP and reinstallation after repairs including pipe line (lower in raw water sump) and servicing of pump assembly with nut and bolts 20mm dia 6 to 2 ½ inch long with nut bolt washers,gland packing,gaskets etc complete all as specified and directed. Note :- (a) The servicing of vertical turbine pump assembly shall be due after six month of Ist service done in the contract. All T&P will be contractor,arrangement. (b) Labour for taking up and lowering and dismantling reassembling of turbine motor and pump assembly or any other parts required to be make the pump functional deemed to included in the quoted rates. (c) Replacement the unserviceable items of pump assembly as under shall be measured and paid for separately.
M&L for replacement suction pipe strainer anong with suction case with plug complete all as specified and directed.
M&L for replacement of Line shaft SS complete all as specified and directed.
M&L for replacement of Impeller Shaft Coupling complete all as specified and directed.
M&L Replacement of BRG holder flang of threaded complete all as specified and directed.
M&L Replacement of Rubber BRG, Nitrile Rubber complete all as specified and directed.
M&L Replacement of Head Shaft coupling complete all as specified and directed.
M&L Replacement of Staling pipe complete all as specified and directed.
Disconnecting/dismantling from foundation and existing pipe line and taking up of defective vertical turbine motor and pump assembly of capacity 20HP and reinstallation after repairs including pipe line (lower in raw water sump) and servicing of pump assembly complete all as specified and directed. Note :- (a) Replacement the unserviceable items of pump assembly as under shall be measured and paid for separately. (b) Labour for taking up and lowering and dismantling reassembling omplete of turbine motor and pump assembly or any other parts required to be make the pump functional deemed to included in the quoted rates . (c) The servicing of vertical turbine pump assembly shall be due after six month of Ist service done in the contract. All T&P will be contractor,arrangement.
M&L for replacement Shaft coupling as per existing pattern complete all as specified and directed.
M&L for replacement Enclosing tube stabilizer complete all as specified and directed.
M&L for replacement line shaft complete all as specified and directed.
M&L for replacement Enclosed line shaft connector bearing complete all as specified and directed.
M&L for replacement line shaft coupling complete all as specified and directed.
M&L for replacement nut and bolts 20mm dia 6 to 2 ½ inch long with nut bolt washer etc complete all as specified and directed.
M&L for replacement brass impeller of VT bowl assembly suitable for 60000GPH complete all as specified and directed.
M&L for replacement oil Tube (Line shaft enclosing Tube) complete all as specified and directed.
Supply & installing submersible sludge dewatering pump of capacity 1 HP single phase,out let dia 50mm , with float switch, discharge 400 to 450LPM , head 10-15m, including connecting pvc insulated copper wire of suitable size as per manufacturer recomendation 2 core- 30Rm complete all as specified and directed at site . Make :- KSB, Kirloskar, CG.
M&L for replacement of ball bearing for pumps/motors of No. 6313/C3 etc complete all as specified and directed. Note :- (i) Dismantling /decoupling, refixing as required shall deemed to be included in item. (ii) The work where only bearing is to be replaced shall be done at plant only.
All as per item No.19 here-in-before but pumps/motors No 6314/C3 complete all as specified and directed.
All as per item No.19 here-in-before but pumps/motors No 6305/6304/C3/2z complete all as specified and directed.
All as per item No.19 here-in-before but pumps/motors No 6306 complete all as specified and directed.
All as per item No.19 here-in-before but pumps/motors No 6307 complete all as specified and directed.
All as per item No.19 here-in-before but pumps/motors No 6308 complete all as specified and directed.
All as per item No.19 here-in-before but for pumps/motors No 6309 complete all as specified and directed.
All as per item No.19 here-in-before but pumps/motors No 6311 complete all as specified and directed.
All as per item No.19 here-in-before but pumps/motors No 6312 complete all as specified and directed.
All as per item No.19 here-in-before but pumps/motors No 6202/6203 complete all as specified and directed.
All as per item No.19 here-in-before but pumps/motors No 6205 complete all as specified and directed.
All as per item No.19 here-in-before but pumps/motors No 6206 complete all as specified and directed.
All as per item No.19 here-in-before but pumps/motors No 6209 complete all as specified and directed.
All as per item No.19 here-in-before but for pumps/motors No 6211/6212/C3 complete all as specified and directed.
All as per item No.19 here-in-before but pumps/motors No 3309 complete all as specified and directed.
All as per item No.19 here-in-before but pumps/motors No. BEP-7310 complete all as specified and directed.
M&L in replacement of connection plate of 30 HP to 75 HP 3 phase electric motor complete all as specified and directed by Engr-in-Charge. Note :- The work shall be carried out at filtration plants/pump houses only.
All as per item No 35 here-in-before but 10 HP to 25 HP 3 phase electric motor complete all as specified and directed. .
All as per item No 35 here-in-before but 2 HP to 7.5 HP 3 phase electric motor.
M&L for repair to bearing housing including re-mettaling / reboring complete of motor 30 HP to 75 HP etc complete all as specified and directed by Engr-in-Charge. Note :- Rates for dismantling /decoupling /transporations and refixing /installation shall deemed to be included in the quoted rate. The work shall be carried out at workshop.
All as per item No 38 here-in-before but motor 10 HP to 25 HP.
All as per item No 38 here-in-before but motor 1HP to 7.5 HP.
M&L for replacement of fan blade assembly complete suitable for motor 50 HP to 75 HP etc complete all as specified and as directed by Engr-in-Charge. Note : The work shall be carried out at plant only.
All as per item No 41 here-in-before but motor 25HP to 40 HP complete all as specified and as directed.
All as per item No 41 here-in-before but motor 7.5 HP to 20 HP complete all as specified and as directed.
All as per item No 41 here-in-before but motor 1 HP to 7.5 HP complete all as specified and as directed.
M&L for repair to starter by replacing the Contactor FP MK-1 as required at site complete all as specified and as directed.
All as per item No 45 here-in-before but Contactor ML 1.5 complete all as specified and as directed.
All as per item No 45 here-in-before but Contactor MNX-50 complete all as specified and as directed.
All as per item No 45 here-in-before but Contactor ML 2 complete all as specified and as directed.
All as per item No 45 here-in-before but Contactor ML 3 complete all as specified and as directed.
All as per item No 45 here-in-before but Contactor ML 4 complete all as specified and as directed.
All as per item No 45 here-in-before but Contactor MNX 25 Amp complete all as specified and as directed.
All as per item No 45 here-in-before but Contactor MNX-32 to 40 Amp complete all as specified and as directed.
All as per item No 45 here-in-before but Contactor Make - BCH type NHD 18 to 25 Amps complete all as specified and as directed.
All as per item No 45 here-in-before but Contactor MNX-80 Amp complete all as specified and as directed.
S&F in repairs thermal over load relay (Bimetal over load relay) suitable for starter type Mk-1 (ML & MN) etc complete all as specified and directed.
All as per item No 55 here-in-before but starter type MN-2 20 to 32 Amps complete all as specified and as directed.
All as per item No 55 here-in-before but starter type LT & LK MN-5 30 to 50 Amps complete all as specified and as directed.
All as per item No 55 here-in-before but starter type LT & LK MN-5 but 45 to 75 Amps complete all as specified and as directed.
All as per item No 55 here-in-before but starter type LT & LK MN-2 14 to 23 Amp complete all as specified and as directed.
All as per item No 55 here-in-before but starter type LT & LK ML-2, 20 to 32 Amp complete all as specified and as directed.
S&F in repairs thermal over load relay (Bimetal over load relay) suitable for BCH starter relay range 3.8 to 6.89 to 13.50 complete all as specified and directed.
S&F in repairs thermal Timer make type ST-100, 3 to 30 sec complete all as specified and directed.
S&F in repairs time delay relay electro PNEUMATIC suitable for starter complete all as specified and directed.
S&F in repairs push button adoptor with element and fixing with screw complete all as specified and directed.
S&F in repairs push button pendants with 2 push button complete all as specified and directed.
S&F in repair Mechanical interlock kit for MNX 9-40 etc complete all as specified and directed.
M&L for in replacement of main switch with HRC fuse 16 to 63 Amp TP&N 415 volt including thimble of suitable size complete all as specified and directed.
M&L for in replacement of MCCB type DN0-100C thermal release range 50-63 Amps TP 415 Volt 25 KA complete all as specified and directed.
M&L for in replacement of MCCB type DN1-250C thermal release range 100-125 Amps TP 415 Volt 25KA complete all as specified and directed.
M&L for in replacement of MCCB type DN1-250C thermal release range 100-125 Amps FP 415 Volt 25KA complete all as specified and directed.
M&L for in replacement of MCCB type DN2-250D thermal release range 125 to 160 Amps FP 415 Volt 36 KA complete all as specified and directed.
M&L for in replacement of MCCB type DN3-400N thermal release range 320-400 Amps Four Pole 415 Volt 36KA complete all as specified and directed.
M&L for in replacement of MCCB type DN3-630D thermal release range 500-630 Amps Four Pole 415 Volt 36 KA complete all as specified and directed.
M&L for in replacement of HRC fuse for 16-63 Amps complete all as specified and directed.
M&L for in replacement of rotary switch 25 Amps complete all as specified and directed.
M&L for in replacement of fuse fitting base 25 Amp Bottle type with HRC fuse complete all as specified and directed.
M&L for in replacement of Amp metre square type 0 to 63/100 Amp CT operated with CT complete all as specified and directed.
M&L for in replacement of Amp metre square type 0-200 Amps CT orperated with CT complete all as specified and directed.
M&L for in replacement of Amp metre square type 0-300 Amps CT orperated with CT complete all as specified and directed.
M&L for in replacement of Amp metre square type 0-400 Amps CT orperated with CT complete all as specified and directed.
M&L for in replacement of Volt meter 0- 500 Volt complete all as specified and directed.
M&L for in replacement LED indicating lamp ( Colors- Red,Yellow & Blue ) complete all as specified and directed.
Dismantling of 75 HP electric motor from foundation and pump opening the same and servicing of motor by cleaning internally and externally , varnishing of stator, greasing of bearing , fittings alignment , connecting electrically , re-fixing and testing etc complete all as specified and directed. Note :The job shall be done at plant only. Next servicing of motor will be due after six months on the date of first servicing under this contract.
All as per item No 83 here-in-before but 50 HP to 60 HP complete all as specified and as directed.
All as per item No 83 here-in-before but 25 HP to 40 HP complete all as specified and directed.
All as per item No 83 here-in-before but 10 HP to 20 HP complete all as specified and directed.
All as per item No 83 here-in-before but 1 HP to 7.5 HP complete all as specified and directed.
M&L for in replacement of wiring with single core FRLS PVC insulated, unsheathed cable 1100 V grade conforming to IS-694, 2.5 sqmm (nominal area) multi-stranded in existing conduit complete all as specified and directed.
M&L for in replacement of wiring with single core FRLS PVC insulated, unsheathed cable 1100 V grade conforming to IS-694, 4 sqmm (nominal area) multi-stranded in existing conduit complete all as specified and directed.
M&L for in replacement of wiring with single core FRLS PVC insulated, unsheathed cable 1100 V grade conforming to IS-694, 6 sqmm (nominal area) multi-stranded in existing conduit complete all as specified and directed.
M&L for in replacement of wiring with single core FRLS PVC insulated, unsheathed cable 1100 V grade conforming to IS-694, 10 sqmm (nominal area) multi-stranded in existing conduit complete all as specified and directed.
M&L for in replacement of wiring with single core FRLS PVC insulated, unsheathed cable 1100 V grade conforming to IS-694, 16 sqmm (nominal area) multi-stranded in existing conduit complete all as specified and directed.
Taking out pump from its existing foundation by cutting nuts & bolts , blocking the outlet & inlet system by proper plate, decoupling and transportation of pump or part there of to contractors workshop and back to site , re- fixing , aligning , connecting inlet and outlet pipe after repair and replacement of following parts (as per requirement) suitable for centrifugal pump type 80/36 for clear water all as specified and directed by Engr-in-Charge. (i) Impleller Cast iron 1st & 2nd stage with key -1 set. (ii) Ring (Entire) - 1 Nos. (iii) Lantern ring -2 Nos. (iv) Water deflector DE & NDE- 2 Nos. (v) Gasket between lower and upper casing -1 Set. (vi) Pump shaft bush DE & NDE – 2 Nos (One NDE & One DE). (vii) Gland for DE NDE stuffing box. (viii) Gland plate-02 Nos Note:- Labour for opening up of pump and machinery work and other minor parts required to make the pump functional shall deemed to be included in the quoted rate.
All as per item No 93.00 here-in-before but parts (i) to (viii) suitable for pump DSM-4 RM for clear water at Plant No-02 but without gland plate complete all as specified and directed.
All as per item No 93.00 here-in-before but suitable for pump UP 100/35 with following parts complete all as specified and directed. (i) Lantern ring – 2 Nos. (ii) Bearing DE & NDE – 2 Nos. (iii) Water deflector DE & NDE- 2 Nos. (iv) Cooling tube for gland (v) Pump shaft bush - 2 Nos. (vi) Rubber ring. 2 Nos. (vii) Gasket between upper & lower casing - 2 Nos. (viii) Gland packing for stuffing box DE & NDE- 2 Nos.
All as per item No 93.00 here-in-before but suitable for pump UP 100/29 with following parts complete all as specified and directed by Engr-in-Charge. (i) Lantern ring – 4 Nos. (ii) Bearing DE & NDE – 3 Nos. (iii) Water deflector DE & NDE- 4 Nos. (iv) Cooling tube for gland (v) Pump shaft bush - 4 Nos. (vi) Rubber ring. 4 Nos. (vii) Gasket between upper & lower casing - 4 Nos. (viii) Gland packing for stuffing box DE & NDE- 4 Nos.
All as per item No 93.00 here-in-before but suitable for pump type SP 4LA with following parts complete all as specified and directed by Engr-in-Charge (i) Split Lantern ring – 1 No. (ii) Rubber flap for flap valve –1 No (iii) Weight for flap valve - 1 No. (iv) Shaft sleeve -1 No. (v) Water deflector – 1 No. (vi) Grease nipple. - 1 No. (vii) Gasket for valute – 1 No. (viii) Gland for stuffing box - 1 No
All as per item No 93.00 here-in-before but suitable for clear water pump DB 80/26 at Filteration Plant No-1 with following parts complete all as specified and directed by Engr-in-Charge. (i) Impeller CI with Key – 2 Nos. (ii) Water deflector - 1 No. (iii) Shaft sleeve - 1 No. (iv) Stuffing box bush – 4 Nos (v) Lock washer and locks nuts – 4 Nos. (vi) Gland packing for stuffing box – 2 Nos. (vii) Gasket for valute – 2 Nos.
All as per item No 93.00 here-in-before but suitable for pump DB 80/32 with following parts complete all as specified and directed by Engr-in-Charge. (i) Impeller CI with Key – 1 No. (ii) Water deflector - 1 No. (iii) Shaft sleeve - 1 No. (iv) Stuffing box bush – 2 No (v) Lock washer and locks nuts – 1 No. Note for Srl item 93 to 99.00 :- (a) Minor replacement of any parts & repair to housing, proper aligning the pump with motor is deemed to be included in the quoted rate. (b) Warranty for one year is to be given from the date of installation of the pump after repair for replaced parts & workmanship. (c) Pumps shall be repaired & reinstalled with in 10 days from the date of handing over of motors.
M&L for replacement flexible cushion tyre coupling of Code No TC/011 complete all as specified and directed.
All as per ser item No 100.00 here-in-before but Code No TC/012 complete all as specified and as directed.
All as per ser item No 100.00 here-in-before but Code No TC/015 complete all as specified and as directed.
All as per ser item No 100.00 here-in-before but Code No TC/016 complete all as specified and as directed.
All as per ser item No 100.00 here-in-before but Code No TC/013 complete all as specified and as directed.
M&L for Dismantling from foundation and Opening of reducing gear box mechanism including Transportation from site to contractors workshop and back after repair including other minor repairs, nut bolts, gasket etc, re- assembling after repair and painting suitable for 2HP motor driven comprising the following item :- (i) Bearing- 4 Nos . (ii) Bearing housing-1 No. (iii) Repair to shaft by welding , turning , mettaling , grinding & like wise mechanical job. (iv) Llubricating oil for gear box. (v) Oil seal. (vi) V belt of existing size -1 No. Note :- The minor repair, nut, bolts, gaskets etc shall deemed to be included in the quoted rate.
All as per item No 105.00 above but suitable for 1 HP motor driven complete all as specified and as directed.
M&L for replacement of mono block pump 15 HP electric driven comprising dismantling / transportation ( to and fro) from site to contractors workshop , opening up, replacement of impeller with key & nut , bush , water deflector , gland for stuffing box /oil seal and gasket for valute all as required for making the pump serviceable , refixing and testing complete all as specified and directed.
All as per No 107.00 here-in-before but Mono block pump 10 HP complete all as specified and as directed.
All as per No 107.00 here-in-before but Mono block Pump 7.5 HP complete all as specified and as directed.
All as per No 107.00 here-in-before but Mono block Pump 5 HP complete all as specified and as directed.
All as per No 107.00 here-in-before but Mono block Pump 3 HP complete all as specified and as directed.
All as per No 107.00 here-in-before but Mono block pressure pump upto 1 HP complete all as specified and as directed.
All as per No 107.00 here-in-before but Mono block 0.5 HP make Servo complete all as specified and as directed.
M&L for servicing of pump set type CSN 80/100 by taking out unserviceable grease, gland packing and providing new grease, gland packing and gasket for volute and making pump set serviceable and testing complete all as specified and directed.
All as per No 114.00 here-in-before but pump type SCP 100-200HA complete all as specified and as directed.
All as per No 114.00 here-in-before but pump type 100/29 and 100/35 & 65/38 complete all as specified and as directed.
All as per No 114.00 here-in-before but pump type DSM 4 RM. complete all as specified and as directed.
All as per No 114.00 here-in-before but pump type DSM 3 ME DSM 80/36 complete all as specified and as directed.
All as per No 114.00 here-in-before but pump type SH 150/32 & SH 100/40 complete all as specified and as directed.
AAll as per No 114.00 here-in-before but pump type DB 80/26 complete all as specified and as directed.
All as per No 114.00 here-in-before but pump type 80/32 complete all as specified and as directed.
All as per No 114.00 here-in-before but pump type SP 4 LA complete all as specified and as directed. (i) Rates for minor parts such as nuts, washer bolts or other minor repair required to make the pump functional is deemed to be included in the quoted rate. (ii) Fresh grease shall be provided after wiping out the existing grease and washing of the bearing with effective reagent. (iii) Next servicing of the pump shall be due after six month on the date of first service done in this CA. (iv) The pump repair under item No.116 to 124 shall not be measures and paid under this item.
M&L in replacement Non metallic rigid PVC conduit of 25mm internal bore ISI marked and fixed with suitably steel clamp /saddle including drawing of existing /new wire and connection complete all as specified and directed.
M&L in replacement Non metallic rigid PVC conduit of 40mm internal bore ISI marked and fixed with suitably steel clamp /saddle including drawing of existing /new wire and connection complete all as specified and directed.
M&L in replacement for PVC flexible pipe having 25mm to 40mm bore as per sample complete all as specified and directed..
Disconnecting/ dismantling / decoupling from foundation and taking up of unserviceable defective motor from installation /pump houses and Refixing of serviceable electric motor 3 phase/Single phase 400/415/440/240/220 V 50 C/S of capacity 0.5 HP to 5 HP ( received after repair or from the spare motors available in store) to the foundation, coupling with pump compressor/gear box etc all as required at site, connecting electrically,aligning properly and testing after installation to the entire satisfaction of Engr-in-Charge.
All as per serial item No 126 here-in-before but of capacity 7.5 HP to 15 HPcomplete all as specified and as directed.
All as per serial item No 126 here-in-before but of capacity 20 HP to 25 HPcomplete all as specified and as directed.
All as per serial item No 126 here-in-before but of capacity 30 HP to 75 HPcomplete all as specified and as directed.
M&L for repair/replacement to unserviceable motor electric 75HP, 3 phase 415/440V 50 C/S of any make comprising the following work complete all as specified and directed. : - (i) Transportation from installation/ store to authorised workshop for repair (ii) (ii) Strip opening of motor and taking out burnt winding, cleaning the slot internally as well as externally motor, stator and bearings etc complete all as specified and as directed by Engr - in - charge. (iii) M&L for rewinding the motor with super enameled copper winding wire of existing gauge complete including insulating material such as insulated paper, glass sleeve , cotton type, varnish etc complete all as specified and directed by Engr-in-Charge. Note :- (i) Replacement of any other parts such as fan blade, connecting plate, ball bearing and repair to housing shall be measured and paid for separately, However repair to bearing housing is deemed to be included in the quoted rate. (ii) Warranty for one year is to be given from the date of installation of the motor after repair. (iii) Motors shall be repaired & re-installed with in 07 days from the date of handing over of motors.
All as per item No 130 here-in-before but capacity of motor 60 HP complete all as specified and as directed.
All as per item No 130 here-in-before but capacity of motor 50 HP complete all as specified and as directed.
All as per item No 130 here-in-before but capacity of motor 40HP complete all as specified and as directed.
All as per item No 130 here-in-before but capacity of motor 30 HP complete all as specified and as directed.
All as per item No 130 here-in-before but capacity of motor 25 HP complete all as specified and as directed.
All as per item No 130 here-in-before but capacity of motor 20HP complete all as specified and as directed.
All as per item No 130 here-in-before but capacity of motor 12.5 HP to 15HP complete all as specified and as directed.
All as per item No 130 here-in-before but capacity of motor 7.5 HP to10 HP complete all as specified and as directed.
All as per item No 130 here-in-before but capacity of motor 5 HP complete all as specified and as directed.
All as per item No 130 here-in-before but capacity of motor 3HP complete all as specified and as directed.
All as per item No 130 here-in-before but capacity of motor 2 HP complete all as specified and as directed.
All as per item No 130 here-in-before but capacity of motor 1 HP complete all as specified and as directed.
All as per item No 130 here-in-before but capacity of motor 0.5 HP. Note for Srl item 130 to 143 : (i) Replacement of any other parts such as fan blade, connecting plate, ball bearing and repair to housing shall be measured and paid for separately, However repair to bearing housing is deemed to be included in the quoted rate. (ii) Warranty for one year is to be given from the date of installation of the motor after repair. (iii) Motors shall be repaired & re-installed with in 07 days from the date of handing over of motors.
M&L for in repair of Raw water pump submersible type 400/440 Volt cap 5 to 7.5HP comprising the following works complete all as specified and directed:- (i) Pumping out water from Raw water tank before taking out pump and before re-lowering of pump other repairs. (ii) Taking out pump along with Col pipe , transportation from plant to contractor’s workshop bulk to site after repair & re-lowering in the tank along with Col pipe connecting acerbically & testing . (iii) Opening up & taking out winding cleaning motor internally & externally. (iv) M&L for rewinding with proper size & quality of super enameled copper wire complete including materials such as insulation paper, sleeves, cotton tape etc. (v) Applying two coat of bade doll on winding after varnishing of the winding. (vi) M&L for replacement of oil seal packing in lubricating oil required. (vii) Reassembling & testing on load.
M&L for in repair of Raw pump submersible type 400/440 Volt cap 15HP model KDS-1537+15 100 x 100 3P CII of Kirlosker make comprising the following:- (i) Pumping out water from Raw water tank before taking out pump and before re-lowering of pump other repairs. (ii) Taking out pump along with Col pipe , transportation from plant to contractor’s workshop bulk to site after repair & re-lowering in the tank along with Col pipe connecting acerbically & testing . (iii) Opening up & taking out winding cleaning motor internally & externally. (iv) M&L for rewinding with proper size & quality of PVC sleeved insulated copper wire complete including materials such as insulation paper, sleeves, cotton tape etc. (v) Applying two coat of bade doll on winding after varnishing of the winding. (vi) M&L for replacement of oil seal packing in lubricating oil required. (vii) Reassembling & testing on load.
M&L for replacement of 10 mm thick gland packing of DE side of pump set model DB 80/26, 80/32 & SP4LA including taking out old worn out gland packing and tightening of foundation bolts and fixing new packing complete all as specified and directed.
All as per Ser item No 146.00 here-in-before but 12mm thick for DE&NDE side of Model no UP100/29, UP 100/35,DSM-4RM,& DSM- 80/36.
Supply, fixing ,connecting and testing sluice valves of size 200mm bore class PN1.6 cast iron body with rising SS spindle, Non rising type and cast iron wheel head both end flanged IS-14846 Body, Cover - CI IS-210, Gr, FG260, Body ring - Bronze IS:318 Gr, LTB2 Door face-Natural rubber , Hinge Pin - SS ASTM A 276 Type 410 Fasteners-CS IS:1367, CL-4.0 Gasket-Natural rubber flange drilling-IS:1538 marked complete with nut & bolts washer etc complete all as specified and directed. Make : Kirloskar
All as per ser item No 150.00 here-in-before but 150mm bore complete all as specified and as directed.
All as per ser item No 150.00 here-in-before but 125mm bore complete all as specified and as directed.
All as per ser item No 150.00 here-in-before but 100mm bore complete all as specified and as directed.
Supply, fixing ,connecting and testing Non Return Valve of size 150mm bore class PN1.6 cast iron body with rising brass spindle, Non rising type and cast iron wheel head both end flanged IS-14846 Body, Cover - CI IS-210, Gr, FG260, Body ring - Bronze IS:318 Gr, LTB2 Door face-Natural rubber , Hinge Pin - SS ASTM A 276 Type 410 Fasteners-CS IS:1367, CL-4.0 Gasket-Natural rubber flange drilling-IS:1538 marked complete with nut & bolts washer etc complete all as specified and directed. Make : Kirloskar
All as per item No 154.00 here-in-before but 125mm bore complete all as specified and as directed.
All as per item No 154.00 here-in-before but 100 mm bore complete all as specified and as directed.
M&L for replacement of single phase preventor 380-440V +/-20% with trip setting and trip time delay model VSP -02 make-Minilec suitable for motor/pumpset protection complete all as specified and directed.
M&L for replacement of water pressure gauge 0-14kg/sqcm complete with air line 3/8'' complete all as specified and directed.
M&L for repair to Clear water pump submersible type 400/440 Volts, Cap 30 HP comprising of following :- (i) Pumping of water from clear water sump before taking out pump and before re-lowering of pump other repairs. (ii) Taking out pump along with Column pipe, transportation from plant to contractor's workshop, back to site after repair & re-lowering in the tank along Column pipe, connecting acerbically & testing. (iii) Opening up & taking out winding cleaning motor internally & externally. (iv) Applying two coat of bade doll on winding after varnishing of the winding. (v) M&L for repalcement of oil seal packing seal in lubricating oil required. (vi) Reassembling & testing on load Note :- All T & P required for lifting and lowering of pump for repair will be provided by the contractor and rate deemed to be included in quoted rates.
Dismantling of unserviceable flange coupling from centrifugal pumping set of capacity 25 HP to 60 HP installed at Filteration Plants for pumping of clear water carefully and suplly & replacing the same with tyre coupling incl required machinary work of shaft, aligning of motor etc complete all as specified and directed.
All as per Srl Item No 160.00 here-in-before but for Raw water centrifugal/VT pumping set of cap 10 HP to 30 HP complete all as specified and as directed.
Taking out pump from its existing foundation by cutting nuts & bolts, blocking the outlet & inlet system by proper plate, decoupling and transportation of pump or part there of to contractor's workshop and back to site, re-fixing, aligning, connecting inlet & outlet pipe after repair and replacement of following parts suitable for centrigugal pump Make - METHER AND PLATT Model WILO Type 80/100 CSN. Note :- Labour for opening up of pumps and machinary work and otehr minor parts required to make the pump functional shall deemed to be included in quoted rate (i) Bronze impeller with key - 01 set (ii) Ring (Entire) - 01 No (iii) Lantern ring - 02 Nos (iv) Water deflector DE & NDE - 02 Nos (v) Gasket between lower & upper casing - 01 Set (vi) Pump shaft bush DE & NDE - 02 Nos ( One NDE & one DE) (vii) Gland for DE NDE shuffing box (viii) Gland plate - 02 Nos (ix) Pump shaft SS - 01 No
Taking out pump from its existing foundation by cutting nuts & bolts, blocking the outlet & inlet system by proper plate, decoupling and transportation of pump or part there of to contractor's workshop and back to site, re-fixing, aligning, connecting inlet & outlet pipe after repair and replacement of following parts suitable for centrigugal pump make - MATHER AND PLATT Model WILO Type SCP100-200HA. Note :- Labour for opening up of pumps and machinary work and otehr minor parts required to make the pump functional shall deemed to be included in quoted rate (i) Bronze impeller with key - 01 set (ii) Ring (Entire) - 01 No (iii) Lantern ring - 02 Nos (iv) Water deflector DE & NDE - 02 Nos (v) Gasket between lower & upper casing - 01 Set (vi) Pump shaft bush DE & NDE - 02 Nos ( One NDE & one DE) (vii) Gland for DE NDE shuffing box (viii) Gland plate - 02 Nos (ix) Pump shaft SS - 01 No
M&L for carrying out maintenance/repairs by removal and dismantling air blower, throughly cleaning, correct setting/timing of impellers, correct differential pressures and replacement of defective parts of Everest air blowers including replacement of lubricating oil/grease Cap-330 Cum/hr, model-42, assembling after repair and reinatallation, testing complete all as directed.(At FP-1,2&3) Note :- (a) Replacement of defective parts will be paid including in this job.
M&L for carrying out maintenance/repairs by removal and dismantling air blower, throughly cleaning, correct setting/timing of impellers, correct differential pressures and replacement of defective parts of Everest air blowers including replacement of lubricating oil/grease Cap- 60 Cum/hr, model-42, assembling after repair and reinatallation, testing complete all as directed.(At FP-1,2&3) Note :- (a) Replacement of defective parts will be paid including in this job.
S&F On load type change over switch open execution of capacity 100 Amps 4 Pole 415 Volts complete with handle all as specified & directed.
M&L painting on existing boards of both sides and stand posts with two coats of synthetic enamel blue paint one coat of metal primer after preparation of old existing surface size and writing the existing letters in existing size with white paint and complete all as speciifed and directed.
M&L for painting of with two coats of synthetic enamel/bituminous paint over one coat of metal primer after preparation of old surfaces existing pipe line structure inside and out side of Filtration Plant No-1.2,3 & 4 any size and any length inclduing sluice valves, Valve Posts, Valve Handles, float valves in side of the filter Beds, Filter bed hand rail structure etc complete all as specified and directed. Note :- Pipe Line - Black Bituminous Vlave Stand Posts - Synthetic enamel Blue paint Valve Handles - Synthetic enamel Red paint Filter Bed Hand rail structure - Synthetic enamel Smoke Grey paint
Supply and fixing on wall, flexy Charts of Dos and Donts, All type of Safety Precautions in Hindi & English, Lay out diagram of each plant for complete all as specified and directed. Note : Size of Chart and letter size shoul be approved by Engineer-in-Charge.
M&L for carrying out maintenance/repairs existing alum/Bleaching/Lime dosing system throughly cleaning, correct setting of gear mechnism replacement of defective parts including replacement of lubricating oil/grease assembling after repair, including repair/replacement of existing discharge pipe line, vlaves etc including painting on motors, gear mechanism complete all as directed by Engr-in-Charge.(At FP-1,2&3) Note :- (a) Replacement of defective parts will be paid including in this job.
M&L for painting of Pumping set of any size and capacity with two coats of synthetic enamel smoke grey paint over one coat of metal primer after preparation of old surfaces complete all as specified and directed.
M&L for laid in trenches GI tube 100mm dia, medium grade with flange with nut&bolts from FP-3, pump house discharge line to FP-3 and from FP-1, Existing borewill pum discharge line to FP-1 flocculator including all fittings complete all as specified and directed.
Attending complaint to clean suction pipe of pump in the raw water sump/clear water sump including repair to NRV/ foot valve with labour and required material i.e. rubber gasket, nut bolt, NRV leaf, weight etc of any size complete all as specified and directed.
Attending complaint for uninterupted operation of power supply to run electric motor of any capacity for repair of LT panel including repairing of normal electric fault due to burnt lugs of Panles, MCCBs, starter connection, contactor and relays of any size and capacity complete all as specified and directed.
Taking out pump from its existing foundation by cutting nuts & bolts , blocking the outlet & inlet system by proper plate, decoupling and, re- fixing , aligning , connecting inlet and outlet pipe after repair of existing cement concrete foundation Type C2 ,1:3:6 (40 mm graded aggregate) and replacement of corrugated/detoriated existing MS Channel any size/type suitable for re-install for Motor and Pump at Filteration Plant No-03 for Raw water Pump with Motors. (Set of 03) (i) Antivibration Pad 100mmX100mm Make :- Duroflex,Everest,Unimac - 4 set. (ii) Nuts ,bolts and Washers as per site requirement. (iii) Necessary PCC work 1;2:4 for grouting of bolts in foundation. Note:- Labour for other minor parts like Packing Sheets required for connection of pump Sets shall deemed to be included in the quoted rate.
Dismantling and shifting and install of Serviceable condition centrifugal pump alongwith electric motor 40 HP and connected items such as starter panel, main Panel from pump hous of raw water reservoir No-4 and re- fixing , aligning , connecting inlet and outlet pipe, cement concrete foundation Type C2 ,1:3:6 (40 mm graded aggregate) with existing MS Channel any size/type including ERW pipe size 150mm for suction and 100mm pipe for delivery side as per site requirement with sluice valve-02 Nos (1x150mm and 1x 100mm), NRV-02 Nos (1x150mm and 1x 100mm) suitable for re-install for Motor and Pump at Filteration Plant No-04 for Raw water Pump with Motor including fabrication work. (Set of 01) (i) Antivibration Pad 100mmX100mm Make :- Duroflex,Everest,Unimac - 4 set. (ii) Nuts ,bolts and Washers as per site requirement. (iii) Necessary PCC work 1;2:4 for grouting of bolts in foundation. Note:- Labour for other minor parts like Packing Sheets required for connection of pump Sets shall deemed to be included in the quoted rate.
Dismantling and shifting and install of Serviceable condition open well submercible and connected items such as starter panel, main Panel from Filteration Plant No-04 and re- fixing, connecting inlet and outlet pipe, re-install for Motor and Pump at Pump house of raw water reservoir No-4. (i) Fabrication for Header with ERW pipe as per site requirement. (ii) Nuts ,bolts and Washers as per site requirement. (iii) Necessary PCC work 1;2:4 for grouting of bolts in foundation. Note:- Labour for other minor parts like Packing Sheets required for connection of pump Sets shall deemed to be included in the quoted rate.
M&L repair for non return valves cast iron body as per IS-5312,heavy duty both end flanged 80mm to 150mm such as seal,disc,gasket,,cover complete all as specified and directed.
M&L for replacement of damage pump casing pump set type 4 MP/P-1340/1 with new one as per OEM (Mather and Platt Pumps Ltd) and providing new grease, gland packing and gasket for volute and making pump set serviceable and testing complete all as specified and directed.
Supply, Laying, jointing and testing mild steel pipe 150 mm bore, heavy grade, ISI marked, with all fittings like sockets flanges, unions, bends, elbow etc laid in trenches or along wall and in floors etc including necessary welding and fabrication works complete all as specified and as directed (Note: Excavation and earth work shall be measured and paid for separately)
DABAA CONTRACTORS
SAINI ELECTRIC STORE
V SATYANARAYANA RAJU
M/S Royal Enterprises
KUNAL ENTERPRISES
M/s Devendera construction
M/S RAJESH KUMAR & SONS
YASHU CONTRACTORS
sun rise constructions
HANS ENGINEERS
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .