Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.6 LAccepted-AOC | ₹15.6 L Quoted ₹17.5 L | L1 | Accepted-AOC Being L1 Bidder |
| 2 | L2₹19.0 L+₹1.5 L (8.41%)Rejected-AOC | ₹19.0 L+₹1.5 L (8.41%) | L2 | Rejected-AOC Not L1 Bidder |
| 3 | L3₹20.5 L+₹3.0 L (17.3%)Rejected-AOC RZ 140 A EAST SAGARPUR STREET NO 7 8 NEW DELHI 110046 | NEW DELHI | NEW DELHI | DELHI | 110046 | ₹20.5 L+₹3.0 L (17.3%) | L3 | Rejected-AOC Not L1 Bidder |
| 4 | L4₹26.1 L+₹8.6 L (49.1%)Rejected-AOC A 303 VEENA CGHS LTD PLOT NO 5D SECTOR 22 DWARKA NEW DELHI 110077 | NEW DELHI | SOUTH WEST DELHI | DELHI | 110077 | ₹26.1 L+₹8.6 L (49.1%) | L4 | Rejected-AOC Not L1 Bidder |
| 5 | L5₹27.3 L+₹9.9 L (56.4%)Rejected-AOC 35 MODEL TOWN G T ROAD JANDIALA GURU DISTRICT AMRITSAR | JANDIALA GURU | AMRITSAR | PUNJAB | ₹27.3 L+₹9.9 L (56.4%) | L5 | Rejected-AOC Not L1 Bidder |
Tender Value
₹30.9 L
EMD Value
₹61,720
Closing Date
22 Dec 2021, 6:00 pmClosed
AGE U WATER SUPPLY DELHI CANTT 10
AGE U WATER SUPPLY DELHI CANTT 10
PETTY REPAIRS FOR ATTENDING DAY TO DAY WATER SUPPLY EXTERNAL COMPLAINTS IN CVD CVD FAMILY QTR PIRU VIHAR SIGNAL GROUP DAD NAUSENA BAGH III CHITRAL LINE OLD CHITRAL LINE BASANTAR LINE BUTCHERY OLD BASE HOSPITAL MAP BEHIND BUTCHERY AFMSD AFTC NPG LINE
2021_MES_492510_1
8221/GE/WS/D-77/2021-22
Open Tender
Civil Works
Item Rate
330 days
AGE U WATER SUPPLY DELHI CANTT 10
Please refer Tender documents.
5 documents required · 5 mandatory
₹500
AGE U WATER SUPPLY DELHI CANTT 10
₹61,720
Yes
6 Apr 2022
4 Dec 2021
24 Dec 2021
4 Dec 2021
22 Dec 2021
17 Dec 2021
Amount
Labour only for attending day to day external water supply compliants of all nature i.e. leakage in water supply pipe lines, fittings/fixtures, over flow of overhead tank, no water supply in CVD, CVD Family Qtr, Piru Vihar, Signal Group, DAD, Nausena Bagh-III and adjoining area including noting the complaints in complaint register complete all as specified and as directed.(Any material required for attending complaints shall be measured & paid separately under respectvie item hereinafter) Note :- Quoted rates shall deemed to be included the elements as mentioned at srl No. 4.01 to 4.07
Attending day to day external water supply complaints of all nature i.e. leakage in water supply pipe lines, fittings/fixture, over flow of overhead tank, no water supply compliants in Chitral line, Old Chitral line, Basantar line, Butchery, Old Base Hospital, MAP behind Butchery,AFMSD, AFTC, NPG line, Hazipeer line, Sekhawati line, 629 TPT Coy, 262 T/camp, DIPAC, DAPS,Adhoc T/camp and adjoining area including (excavation work due to no water supply ) from various areas as per complaint register etc complete all as specifed and as directed. Note :- Quoted rates shall deemed to be included the elements as mentioned at srl No. 4.01 to 4.07
Attending Electric supply complaints of day to day maintenace of existing LT Panels including connecting electrical accessories / spares of water supply installation ,electrical fitting with lights, short circuits in Pump house of CVD, CVD Family Qtr, Piru Vihar, Signal Group, DAD, Nausena Bagh-III and adjoining area as per complaint register complete all as specified and as directed. Note :- Ser No . 1 & 3 Material required for attending complaints shall be measured & sparately under respectvie items here - in- after.
Attending of Electric supply complaint of day to day maintenace of existing LT Panels including connecting electrical accessories / spares of water supply installation ,electrical fitting with lights , short circuits in Pump house of Chitral line, Old Chitral line, Basantar line, Butchery, Old Base Hospital, MAP behind Butchery,AFMSD, AFTC, NPG line, Hazipeer line, Sekhawati line, 629 TPT Coy, 262 T/camp, DIPAC, DAPS,Adhoc T/camp and adjoining area as per compliant register complete all as specified and as directed. Note ;- Ser No. 2 & 4 Material required for attending complaints shall be measured & sparately under respectvie items here - in- after.
Notes for Item No 1,2,3& 4 The complaints shall be attended and the defetcs shall be rectified by a team of matric qualified having minimum 03 years experienced electrician/Plumber as applicable assisted with adequate No of helpers as directed by Engineer-in-charge
The complaints shall be attended & defect shall be rectified within 08 hrs commencing from date and time of notifying the complaint failing which a penalty @ Rs 50/- per complaint per day (08 hrs) shall be levied upon/imposed on the contractor and recovery shall be made from contractor's dues.
In case , after checking & attending the defect, it is not possible to rectify the defect within 08 hrs, the facts shall be brought to the notice of Engineer-in-charge by the contractor/his rep. If Engineer-in- charge is satisfied with contractors view, no recovery will be made.
While attending the complaint of water supply if earth work is required then the same shall be measured and paid seperately under appropriate item of Sch 'A'. However , no extra payments shall be made for dewatering
Cutting of GI pipe in position and threading is also deemed to be included in the job rate (Fittings and fixtures will be measured and paid separetely under respective items of Sch)
All T&P required for attending the Complaints shall be provided by the contractor.
The Pipe Fitter shall always be in possession of die set complete with cutters,Taps, Pipe wrench ,Chain wrench, Caulking tools, complete set of spanners and ladders etc ,as required at site.
The Electrician shall always in possession of all Electrician tools, LT Megger, Earth Tester, Multimeter , Crimpling tool, insulation tape, Hand gloves etc required at site.
Rate for taking down/out existing & fittings & fixtures and refixing to make it functional shall be into account.
Supply only of the following items:- Supply only GI Socket Med grade ISI Marked of following sizes : -
15 mm bore
20 mm bore
25 mm bore
40mm bore
50mm bore
Supply only GI Elbow Med grade ISI Marked of following sizes : -
15 mm bore
20 mm bore
25 mm bore
40mm bore
50mm bore
Supply only GI Union Med Grade ,ISI marked of following Sizes:-
15 mm bore
20 mm bore
25 mm bore
40 mm bore
50 mm bore
GI Nipple Med grade of different size as per requirement both end screwed ISI Marked of following sizes
15 mm bore
20 mm bore
25 mm bore
40mm bore
50mm bore
Supply only GI Reducing socket medium grade ISI marked of the following sizes :-
20 mmx15mm bore
25mmx20mm bore
50 mm x 40 mm bore
25 mmx 15mm bore
40 mmx 25mm bore
Supply only GI solid plug heavy duty ISI marked of following sizes
15mm bore
20 mm bore
25 mm bore
40 mm bore
50 mm bore
Supply Only GI Tee Med grade ISI Marked of following sizes:-
15 mm x 15 mm x 15 mm
20 mm x 20 mm x 15 mm
20 mm x 20 mm x 20 mm
25 mm x 25 mm x 25 mm
25 mm x 25 mm x 15 mm
40 mm x 40 mm x 40 mm
50 mm x 50 mm x 50 mm
50 mm x 50 mm x 25 mm
25 mm x 25 mm x 20 mm
40 mm x 40 mm x 15 mm
40 mm x 40 mm x 20 mm
40 mm x 40 mm x 25 mm
50 mm x 50 mm x 15 mm
50 mm x 50 mm x 20 mm
50 mm x 50 mm x 40 mm
Supply only following items
Lead pig bar
Spun yarn
Lead wool
Labour only for run lead joint by using old lead and new spun yarn for CI/DI pipes of following size:-
80 mm bore
100 mm bore
150 mm bore
Labour only for run lead joint by using new lead and new spun yarn including jointing material for CI/DI pipes of following size/bore Note: Lead and spun yarn used for repairing the following sizes of pipe joints shall be paid separately)
80 mm bore
100 mm bore
150 mm bore
Nuts ,Bolts and Washers 25 to 150 mm long of 6 to 20 mm dia
Bib taps PTMT alloy with crutch / butterfly handle screwed down for 15 mm bore
Laying and Fixing in replacement of GI Pipe medium grade, ISI marked including all fittings in old/new position in trenches/wall/floor complete and making good the disturbed surface as per existing of following sizes. Note : GI Pipe shall be issued under Sch 'B' as free for fixing only.
15 mm bore dia
20 mm bore dia
25 mm bore dia
40 mm bore dia
50 mm bore dia
Fixing only PTMT Float valve with epoxy coated aluminium rod and high density plastic ball of following sizes. Note : PTMT Float Valve shall be issued under Sch 'B' as free for fixing.
15 mm bore
20 mm bore
25 mm bore
50 mm bore
Supply only UPVC elbow ISI Marked of following Sizes :-
15 mm bore
20 mm bore
25 mm bore
Supply only UPVC socket ISI Marked of following sizes:
15 mm bore
20 mm bore
25 mm bore
Fixing only Gun metal gate valve with iron wheel head screwed both ends for iron pipe as per IS-778 complete, ISI marked including taking out unserviceable gate valve. Note : Gun Metal gate Valve shall be issued under Sch 'B' as free for fixing.
15 mm bore
20 mm bore
25 mm bore
40mm bore
50 mm bore
Excvation in trenches not exc. 1.5 mtr wide and not exc 1.5 mtr deep for pipe line in soft/loose soil, getting out and levelling of bottom surface as required complete all as specified and as directed
Returning filling in , including spreading, levelling, watering and well ramming in layers not exc 25 cm thick complete all as specified and as directed
Removing excavated material from site to a distance not exc 50 m away and depositing where directed at a level not exc 1.5 meters above the starting point complete all as specified and directed
Supplying and laying well burnt bricks sub class B for protection of cable for complete all as specified and as directed
Supply and laying for sand cushioning to cable with a layer of sand 8 cm deep before laying and 15cms deep after the cable (punned down to 18cms depth after laying and stretching of cable) compete all as specified and as directed.
Supplying and fixing CPVC pipe ISI Mark SDR 11 with all fittings in old/new position in trenches/ floor and making good the disturbed surfaces as per exisitng including taking out unserviceable CPVC pipe, complete all as specified and directed of the following sizes:- (Earth work shall be measured & paid sepreately under relevent schedule 'A' items )
20 mm bore
40 mm bore
50 mm bore
M&L for CI special such as Tees, Bends of any size Radius, Collars, Tapers, Tail pieces, caps and plugs etc upto 200 mm dia complete all as specified and as directed
Labour work required for taking out suction pipe from sump of any capacity 80 mm to 200 mm size screw / flanged type and relowering after refixing in position the same duly cleaned / minor repair if any required such as replacement of rubber gasket / lifting bolts & nuts including making thread for the suction pipes off sizes etc complete all as specified and as directed
Labour work required for opening top cover of sluice valve of sizes as under including gland cover taking out stem with stem nut of brass / SS and refixing the same after including replacement of rubber packing and and nuts / bolts/ glands dori etc of appropriate size Note : Any spare parts like stem, nuts, gland plate of required size shall be measured and paid separately under respective items here-in-after
80mm bore
100mm bore
150mm bore
200mm bore
250/300 mm bore
Supply only 'stem' made out from SS (All as per sample) of sluice valve of size as under: -
80mm bore
100mm bore
150mm bore
200mm bore
Supply only 'Stem Nut ' made out from Stainless Steel suitable to match with existing sluice valve of size as under: -
80mm bore
100mm bore
150mm bore
200mm bore
Testing of drinking water being collected from local source (bore wells/shallow wells/under ground sumps) in the area under AGE(U) W/S No I and submission of detailed test reqport to the office of Engineer-in-Charge. (a) Collection of water from different sources of water ie Sump, bore wells & shallow wells in sterilized bottle and testing in Govt Approved laboratory as mentioned in specification. (b) Carrying out minimum essential testing of water as per IS 10500-1991 mandatory for chemical colour, odour, taste, turbidity, PH value TDS total hardness, iron, chloride, fluride and residual free chlorine and Bacteriological total Collie from organisms per 100 ml (MPN) and E Collie in 100 ml) and submission to this office with specific recommendation regarding suitability of water for drinking purpose. Note :- Rate quoted shall deemed to be included for : - (i) Cost of sterilized bottle as required. (ii) To and fro transportation charges for collection of samples from source(sump/bore well/shallow wells)
Taking up or down CI/DI pipe from wall , floor, trenches including all fitting of following size.
100 mm bore dia
150 mm bore dia
Supply, laying jointing,testing DI pipe with spigot socketed ends , class K-7, conforming to IS-8329-2000 laid in trenches of the following sizes as specified and directed by Engr-in-Charge. Note ;- Joint will be measerd and paid seprataly.
100 mm bore
150 mm bore
Supply and Fixing CI Foot valve of size 80mm bore, Flanged ends, Swing type opration with rubber sheet as per IS-4038 complete all as specified and directed Note :- Flanged joints complete with jointing material shall deemed to be included in the unit rate of this items
All as above but for 100 mm bore dia
All as above but for 150 mm bore dia
Supply and fixing jointing and testing of cast iron Non return valve without by pass arrangment swing type confirming to IS 5312 flanged ends pressure rating PN 1.0 complete including taking out unserviceable NRV complete all as specified and as directed. Note - Flanged joints complete with rubber jointing materail shall deemed to be included in the unit rate of this item
80 mm bore
100 mm bore
150 mm bore
Supply and installation of flanged ends strainer/dirt box, with stainless steel mesh suitable for water meter for potable water supplies on up stream of water meter to avoid foreign material entering into meter including taking out unserviceable of following sizes complete all as specified and as directed
100 mm bore
150 mm bore
Supply and installation of flanged ends Water Meter woltman type, including testing and making good connection with flanged ends, with gasket rubber sheet and nut & bolts etc ISI Marked fixing in horizontal/incline/vertical position, including taking out unserviceable complete all as specified and as directed
100 mm bore
150 mm bore
Material and labour for CI special such as tees, bends of any sizes and radius, tapers, collars, tail pieces, caps and plugs upto 200 mm bore.
Supplying,fixing, jointing and testing of cast iron sluice valves of size 80mm bore class PN-1.6, conforming to IS14846 flanged ends drilled having stainless steel spindle with cast iron wheel at top complete with nuts, bolts, washers and rubber gaskets complete all as specified and as directed. Including taking out unservicerble sluice valve.
All as above but for 100 mm bore dia
All as above but for 150 mm bore dia
Material and Labour for surface dressing either by using hydraulic excavator or manual excavation to give an even surface by clearing off all debris, wild jungle growth, vegetation, trimming trees and unwanted plants in and around the area of installations/around the valve pit chamber/along the pipe line routes if reqd etc and all this vegetation and debris (malba) shall be disposed of as directed by authorised representative. The entire area shall be levelled/graded as directed
M&L for removing weeds and wild grass inside all the seven installations using sufficient weed killer chemical spray using hand/battery operated machine on quarterly basis complete all as specified and as directed. Note : Quoted rates shall deemed to be included the rate of chemical and T&P.
Supply only switch /sockets ISI marked of following items :
Switch piano flush type 5/6 Amps singal pole one way, 240 volts
Switch piano flush type 15/16 Amps singal pole one way, 240
Socket outlet 2 in 1, 3/5 pin, 5/6 Amps 240 volts
Socket outlet 2 in 1, 3/5 pin, 15/16 Amps 240 volts
Switch socket combination 2 in 1, 3/5 pin, 5/6 Amps 240 volts
Switch socket combination 2 in 1, 3/5 pin, 15/16 Amps 240 volts
Supply only following electrical items:
MCB SP 10 to 32 Amp, 240 volts
MCB SPN 40 Amp , 240 volt
MCB TP 63 Amp , 415 volt
PVC insulation tape role 15mm wide, 20 Running meter long
PVC insulated multistranded copper conductor wire of size 1.5 Sqmm, 1100 volts grade
PVC insulated multistranded copper conductor wire of size 2.5 Sqmm, 1100 volts grade
Supply only in replacement of 1100 volts grade heavy duty cable PVC insulated aluminium stranded conductor served with inner sheathing of PVC tape and overall PVC sheathed in service connections twin core cable flat or circular 4 sqmm complete all as specified and directed by Engr-in-charge
LED bulb of 7/9 watt make Havells/ CG/ASEAN/Bajaj
Surface Decorative ultra Slim Round Profile LED Lighting fixture and Extruded Policarbonate, Environmental friendly , Energy Efficient 18 Watt connection complete all as specified and as directed.
M&L for Decorative ultra slim round profile LED lightning fixture 20W, 6000K, with extruded polycarbonate environmental friendly energy efficient incl taking down old unsv light fitting complete all as specified and as directed
Supply and fixing in replacement 60 watt LED street light New generation energy saving and environmental friendly long life LED street light made up of pressure die cast aluminium housing with high efficient LED as lighting source and PC cover having TOP Opening seperate driver compartment with IP66 protection and impact resistance of IK07 including making connections with GI pipe 0.6mtr angle braket fixing on wall and connectng to ceiling rose with apropriate wire complete all as specified and as directed.
Supply and fixing in replacement heat shrinkable jointkit suitable for XLPE cable insulated screened PVC bedded armoured electric power cable heave duty 1100 volts grade, with straded aluminium conductor, cross sectional area 25/35 Sqmm, 3.5 core after taking down/out faulty portion as exists compete all as specified and as directed.
Suppply & fixing in replacement MCCB 160 Amps, 4 pole , breaking capacity 36 KA, connection complete all as specifed and as directed
Suppply & fixing in replacement MCCB 100 Amps, 3 pole , breaking capacity 25 kA, connection complete all as specifed and as directed
Suppply & fixing in replacement MCCB 63 Amps, 3 pole , breaking capacity 16 kA,connection complete all as specifed and as directed
Suppply & fixing in replacement analog type time switch FM 1/Quartz daily 240 volts , AC, 50 Hz code J 6107B 204 connection complete all as specifed and as directed
Supply and fixing in replecement of 3 pole power contactor 25 Amp 415/440 volts 50 HZ type ML 1.5 Cat part No SS91851
Supply and fixing in replecement of 3 pole power contactor 32 Amp 415/440 volts 50 HZ type ML 2 Cat part No SS90701
Supply and fixing in replecement of Bimetal over load realy for ML 1.5 Starter type 10-16 Amp Cat Part No SS91858OOBO.
Supply and fixing in replecement of Bimetal over load realy for ML 2 Starter type range 13-21 Amp Cat Part No SS91859OOCO
Supply and fixing fully automatic Star delta starter type ML in FASD ML 1.5 Cat part No SS91855
Supply and fixing fully automatic Star delta starter type ML in FASD ML 2 Cat part No SS90705 ze
Supply and fixing in replacement PVC insulated multistranded Aluminium conductor 1100 volts grade, cross sectional area 25 Sqmm, 3.5 core as in trenches or through floors, fixed on panels/walls with fixing arranements compete all as specified and as directed.
Supply and fixing in replacement PVC insulated multistranded Aluminium conductor 1100 volts grade, cross sectional area 35 Sqmm, 3.5 core as in trenches or through floors, fixed on panels/walls with fixing arranements compete all as specified and as directed.
Supply and fixing rotational moulded polyethylene water storage tank , cylindrical vertical with closed top, 500 ltrs capacity, trippple layered hoisted and fixed in position after taking down as existing at site (of any capacity) complete all as specified an as directed. Note: For Pump Priming purpose in pump house.
Taking down cement plaster or cement lime plaster on PCC/Stone surface/brick surfaces including raking out joints hacking for key scrubbing down with water etc complete all as specified and as directed .
Rendering 15 mm thick in CM (1:4) on fair faces of brickwork or concrete surfaces finished even & smooth.
Demolition of brick work or stone/boulder masonry built in cement mortar including all quoin jambs pillars etc.
M&L Brick work with sub class 'B' old size bricks bricks straight or cured on plan exceeding 6 m mean radius built in cement mortar 1:6
M&L for coloured Glazed ceramic tiles in vertical surfaces of size 300mm x 200mm, 7mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and as directed.
Demolition and dismantling concrete in ground floors and pavings n exc 15 cm thickness below or above ground level.
M & L for PCC (1:3:6) type C2 using 40mm graded aggregate as in foundation for including fair finish even and fair to exposed surfaces without using extra cement complete all as specified and as directed
M&L Machine pressed precast concrete interlocking paverblocks any shape and size confirming to IS 15658-2006 of 60 mm thick, M-40 Grade with grey cement and no pigments, over 25 mm thick sand cushioning complete all as specified and as directed. Note : Sand Cushioning shall be measured and paid under respective item.
M&L for chequered cement conc. Tiles 20cm*20cm*20mm & pigment set, jointed and pointed in neat cement slurry laid over 20 mm thick scred bedding in CM (1:6)
M&L for preparation of old painted steel and iron surfaces of any description over 10 cm in width or girth and applying one coat of synthetic enamel paint complete all as specified and as directed.
M & L for Tank Cover/Valve Chamber Cover made out of mild steel plain sheet of any thickness as in cover for existing valve chamber along with provision of angle iron frame cut to length, bent to shape, welding and fabricate to requiredd shape/ size incl necessary fixing materials like hinges, nut/ bolts etc with two coat of synthetic enamel paint over a coat of red oxide primar and incl lifting handle and taking out the old unsv valve chamber cover complete all as specified and as directed.
Testing the cables with high voltage DC testing machine and locating the fault in the cables by fault locating machine to pin point exact position of fault, disconnecting faulty 1100 volts LT cables of different sizes from both ends , removal of fault , Reconnection and testing of cables after removal of fault complete all as specified and directed. NOTE:(a) 1100 volt cables and joints shall be measured and paid for seperately under respective items of schedule (b) Retrieved old serviceable cable cover/ bricks will be laid in trenches for cable protection. If extra PCC cover / bricks and sand required at site shall be measured and paid separately under respective items of BOQs. (c) Exacavation and earth work will be measured and paid for separately under respective items of schedule.
M&L for fabrication (welding work) of MS Header /any size upto 300 mm MS pipe at various pump house for arresting leakages on header complete all as specified and as directed.
Supplying , laying , jointing, welding and testing MS Pipe (Heavy class 'C') IS : 1239/3589, of followiing sizes laid in trenches or in Horizontal/Vertical/inclined position or laying on floors for connections for suction, to header and connected to out going water main CI/DI pipe line, for following size including taking out the old unserviceable pipes :- Note:- MS Flanges incl fabrication work will be measured and paid separately.
80 mm dia
100 mm dia
150 mm dia
Supply and fixing in replacement Rubber or fiber board gasket for flanged joint suitable for 80/100/150 mm bore pipe compete all as specified and as directed.
Supply and fixing MS flange ,16mm thick duly welded with flange joint including nuts bolts ,washer ,Rubber or fiber board gasket joint of size 100mm size
80 mm dia
100 mm dia
150 mm dia
An amount of Rs 184828.00 shall be deducted from BOQ on account of schedule of credit
Yadav Enterprises
Deven Associates
Ridhi engineers and builders
STAR CONSTRUCTION CO
Sanjay Associates
Microsys Controls India
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .