| 1 | L1₹38.5 LAccepted-Finance NEAR PUMP HOUSE ROAD NEAR RED ROSE SCHOOL BABINA CANTT JHANSI DISTT UP 284401 | JHANSI | UTTAR PRADESH | 284001 | ₹38.5 L | L1 | Accepted-Finance Being L1 |
| 2 | L2₹39.9 L+₹1.3 L (3.49%)Rejected-Finance 1308 MAIN ROAD BABINACANTT DIST JHANSI 284 401 | BABINA | JHANSI | UTTAR PRADESH | 284401 | ₹39.9 L+₹1.3 L (3.49%) | L2 | Rejected-Finance Other than L1 |
| 3 | L3₹39.9 L+₹1.4 L (3.53%)Rejected-Finance A 63 ELDECO COUNTY PHASE II RAJGARH JHANSI U P 284135 | JHANSI | JHANSI | UTTAR PRADESH | 284135 | ₹39.9 L+₹1.4 L (3.53%) | L3 | Rejected-Finance Other than L1 |
| 4 | L4₹40.0 L+₹1.4 L (3.67%)Rejected-Finance 1010 NANDANPURA BABINA CANTT DIST JHANSI 284401 | BABINA CANTT | JHANSI | UTTAR PRADESH | 284401 | ₹40.0 L+₹1.4 L (3.67%) | L4 | Rejected-Finance Other than L1 |
| 5 | L5₹40.4 L+₹1.8 L (4.80%)Rejected-Finance 135 CHAKRANA TIWARI CHAKA NAINI PRAYAGRAJ 211008 UTTAR PRADESH | PRAYAGRAJ | UTTAR PRADESH | 211008 | ₹40.4 L+₹1.8 L (4.80%) | L5 | Rejected-Finance Other than L1 |
| Sl No | Description | Qty | Unit | VIJAY BUILDERS L5 | M/S Ritu Tandon L1 | M/S RAJ KUMAR SINGH L2 | ROHIT ENTERPRISES L3 | M/S Kharya Associates L6 | M/S M S Constructions L4 |
|---|---|---|---|---|---|---|---|---|---|
| 1.01 | M & L and taking down old U/S twin core cable and Supplying and fixing 1100 volts grade heavy duty cable PVC insulated aluminium conductor standard, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspen ded by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core cable flat or circular 1100 V size 6 sq mm to be connected to existing MCB box / Main switches complete all as specified as directed. Make :- Finolex/Havells/HPL/Anchor. | 300 | RM | 60 ₹18,000 | 21 ₹6,300 | 20 ₹6,000 Lowest | 60 ₹18,000 | 30 ₹9,000 | 20 ₹6,000 Lowest |
| 2.01 | All as per srl item No. 1 here-in-before but twin core cable of size 10 sq mm complete all as specified and directed. | 300 | RM | 80 ₹24,000 | 52 ₹15,600 | 25 ₹7,500 Lowest | 75 ₹22,500 | 40 ₹12,000 | 35 ₹10,500 |
| 3.01 | All as per srl item No. 1 here-in-before but twin core cable of size 16 sq mm complete all as specified as directed. | 100 | RM | 100 ₹10,000 | 56 ₹5,600 | 35 ₹3,500 Lowest | 90 ₹9,000 | 50 ₹5,000 | 45 ₹4,500 |
| 4.01 | S&F in repair/replacement of Circuit/submain wiring alongwith earth wire 2 runs x 1.5 sqmm + 1 run x 1.5 sqmm with FRLS-H PVC insulated unsheathed 1100 volts grade copper conductor, single core multi stranded cable drawn through and including medium grade rigid PVC conduit not less than 20 mm dia (Existing / new) conforming to IS:9537 (Pt-III) and its all accessories/junction boxes/ inspection covers lugs etc of suitable size but not less than 20 mm concealed in wall/ floor etc including taking down old U/S submain wiring complete all as specified and directed by Engineer-in-Charge. Make :- Finolex/Havells/HPL/Anchor. Note: Three runs of copper cable and one run of PVC conduit shall be measured as one unit length. | 200 | RM | 50 ₹10,000 | 38 ₹7,600 | 36 ₹7,200 Lowest | 50 ₹10,000 | 40 ₹8,000 | 42 ₹8,400 |
| 5.01 | All as per srl item No. 4 here-in-before but of size 2 runs x 2.5 Sqmm + 1 run x 2.5 Sqmm. Note: Three runs of copper cable and one run of PVC conduit shall be measured as one unit length | 180 | RM | 75 ₹13,500 | 65 ₹11,700 | 48 ₹8,640 Lowest | 55 ₹9,900 | 60 ₹10,800 | 58 ₹10,440 |
| 6.01 | All as per srl item No. 4 here-in-before but of size 2 runs x 4 Sqmm + 1 run x 4 Sqmm. Note: Three runs of copper cable and one run of PVC conduit shall be measured as one unit length | 200 | RM | 160 ₹32,000 | 98 ₹19,600 | 90 ₹18,000 Lowest | 150 ₹30,000 | 125 ₹25,000 | 140 ₹28,000 |
| 7.01 | All as per srl item No. 4 here-in-before but of size 2 runs x 6 Sqmm + 1 run x 6 Sqmm. Note: Three runs of copper cable and one run of PVC conduit shall be measured as one unit length | 600 | RM | 270 ₹1,62,000 | 170 ₹1,02,000 | 150 ₹90,000 Lowest | 200 ₹1,20,000 | 175 ₹1,05,000 | 166 ₹99,600 |
| 8.01 | All as per srl item No. 4 here-in-before but of size 2 runs x 10 Sqmm + 1 run x 10 Sqmm. Note: Three runs of copper cable and one run of PVC conduit shall be measured as one unit length | 100 | RM | 300 ₹30,000 | 170 ₹17,000 Lowest | 200 ₹20,000 | 250 ₹25,000 | 200 ₹20,000 | 250 ₹25,000 |
| 9.01 | S & F in repair/replacement Regid non-metallic PVC conduit medium grade not less than 20 mm dia (external) ISI marked (concelaled or surface as per site requirement) incl of all accessories and all fittings such as Tees,bends, elbows, reducers, bell mouth, tube ends and fixing accossories such as couplers,lock nuts, saddles, pipe hook etc complete including cutting necessary chases on wall/ceiling surfaces for drawing of conduit and making good disturbed surfaces of wall with CM 1:3:4 and matching with the existing surfaces including colour washing all as specified and as directed | 900 | RM | 20 ₹18,000 | 32 ₹28,800 | 18 ₹16,200 Lowest | 25 ₹22,500 | 22 ₹19,800 | 30 ₹27,000 |
| 10.01 | All as per srl item No. 9 here-in-before but of casing capping complete all as specified and directed. | 100 | RM | 30 ₹3,000 | 38 ₹3,800 | 40 ₹4,000 | 25 ₹2,500 Lowest | 30 ₹3,000 | 26 ₹2,600 |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
25 Jul 2026, 6:00 pmClosed
GE Babina
PIN-284401
COMPREHENSIVE REPAIR/MAINT/REPLACEMENT OF UNSV WIRING, INTERNAL ELECTRIC FIXTURES, ELECTRIC METERS AND OTHER CONNECTED E/M WORK IN OTM ACCN AT OLD CAMP AND ADJOING AREA UNDER GE BABINA
2026_MES_776523_1
8563/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE Babina
As per tender documents
8 documents required · 8 mandatory
₹500
GE Babina
₹80,000
Yes
18 Sept 2026
4 Jul 2026
30 Jul 2026
4 Jul 2026
25 Jul 2026
18 Jul 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1.01 | M & L and taking down old U/S twin core cable and Supplying and fixing 1100 volts grade heavy duty cable PVC insulated aluminium conductor standard, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspen ded by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core cable flat or circular 1100 V size 6 sq mm to be connected to existing MCB box / Main switches complete all as specified as directed. Make :- Finolex/Havells/HPL/Anchor. | 300 | RM | - | - |
| 2.01 | All as per srl item No. 1 here-in-before but twin core cable of size 10 sq mm complete all as specified and directed. | 300 | RM | - | - |
| 3.01 | All as per srl item No. 1 here-in-before but twin core cable of size 16 sq mm complete all as specified as directed. | 100 | RM | - | - |
| 4.01 | S&F in repair/replacement of Circuit/submain wiring alongwith earth wire 2 runs x 1.5 sqmm + 1 run x 1.5 sqmm with FRLS-H PVC insulated unsheathed 1100 volts grade copper conductor, single core multi stranded cable drawn through and including medium grade rigid PVC conduit not less than 20 mm dia (Existing / new) conforming to IS:9537 (Pt-III) and its all accessories/junction boxes/ inspection covers lugs etc of suitable size but not less than 20 mm concealed in wall/ floor etc including taking down old U/S submain wiring complete all as specified and directed by Engineer-in-Charge. Make :- Finolex/Havells/HPL/Anchor. Note: Three runs of copper cable and one run of PVC conduit shall be measured as one unit length. | 200 | RM | - | - |
| 5.01 | All as per srl item No. 4 here-in-before but of size 2 runs x 2.5 Sqmm + 1 run x 2.5 Sqmm. Note: Three runs of copper cable and one run of PVC conduit shall be measured as one unit length | 180 | RM | - | - |
| 6.01 | All as per srl item No. 4 here-in-before but of size 2 runs x 4 Sqmm + 1 run x 4 Sqmm. Note: Three runs of copper cable and one run of PVC conduit shall be measured as one unit length | 200 | RM | - | - |
| 7.01 | All as per srl item No. 4 here-in-before but of size 2 runs x 6 Sqmm + 1 run x 6 Sqmm. Note: Three runs of copper cable and one run of PVC conduit shall be measured as one unit length | 600 | RM | - | - |
| 8.01 | All as per srl item No. 4 here-in-before but of size 2 runs x 10 Sqmm + 1 run x 10 Sqmm. Note: Three runs of copper cable and one run of PVC conduit shall be measured as one unit length | 100 | RM | - | - |
| 9.01 | S & F in repair/replacement Regid non-metallic PVC conduit medium grade not less than 20 mm dia (external) ISI marked (concelaled or surface as per site requirement) incl of all accessories and all fittings such as Tees,bends, elbows, reducers, bell mouth, tube ends and fixing accossories such as couplers,lock nuts, saddles, pipe hook etc complete including cutting necessary chases on wall/ceiling surfaces for drawing of conduit and making good disturbed surfaces of wall with CM 1:3:4 and matching with the existing surfaces including colour washing all as specified and as directed | 900 | RM | - | - |
| 10.01 | All as per srl item No. 9 here-in-before but of casing capping complete all as specified and directed. | 100 | RM | - | - |
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.51 MB
8563Tendedoc.pdf
Tender Documents • 1.25 MB
BOQ_869567.xls
BOQ • 2.03 MB
Tender_Acceptance_Letter.pdf
Additional Documents • 0.08 MB
Workdetails.pdf
Additional Documents • 0.09 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .