Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹33.4 LAccepted-AOC INDEX NO D 1478 CE SC PUNE PLOT NO 44 11 KACHNAYAKANHALLI VILLAGE JIGANI HOBLI ANEKAL TALUK BANGALORE PIN 560 106 KARNATAKA STATE | 560106 | ₹33.4 L Quoted ₹34.3 L | L1 | Accepted-AOC Lowest quoted amount overall reasonable |
| 2 | L2₹34.7 LRejected-AOC H NO 831 1 HINDU NAGAR TILAKWADI BELGAUM 590006 | BELGAUM | BELGAUM | KARNATAKA | 590006 | ₹34.7 L | L2 | Rejected-AOC 2nd lowest hence rejected |
| 3 | L3₹37.8 LRejected-AOC | ₹37.8 L | L3 | Rejected-AOC 3rd lowest hence rejected |
| 4 | L4₹39.8 LRejected-AOC | ₹39.8 L | L4 | Rejected-AOC 4th lowest hence rejected |
| 5 | L5₹40.4 LRejected-AOC | ₹40.4 L | L5 | Rejected-AOC 5th lowest hence rejected |
| Sl No | Description | Qty | Unit | M/s Sohanil Construction L4 | DHAIRYASIL RAMAKANT DESAI L2 | Kedar Electricals L3 | M/s.GOODWILL ELECTRICALS L6 | SREE VINAYAKA ENTERPRISES L8 | BRO TECH ELECTRICAL & ENGINEERING SOLUTION L1 | Green Ray Enterprises L7 | RAJARAM TAYAPPA DANDAGALKAR L5 |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | M&L for Point wiring with 1.5 Sq.mm FRLSH PVC insulated unsheathed copper conductor cable, single core multi stranded 1100Volt grade conforming to IS 694: 1977, drawn in and including rigid PVC conduit not less than 20mm bore, concealed/surface type, medium grade as per IS 9537 (Part 1-1983) with conduit accessories, junction boxes, tees, terminal boxes with and including factory made modular metal / pvc boxes as required at site including modular cover plates (white) with frame for mounting modular switches, including one run of 1.5 Sq.mm single core FRLS PVC unsheathed copper conductor cable as earth continuity conductor and connected to common earth dolly, for one light / fan /bell point controlled by one way switch/MCB, including taking down old u/s point wiring of any type with fittings, complete all as specified and as directed. Note: Cutting chases and making good surfaces shall be included in the unit rate. | 160 | Each Point | 395 ₹63,200 | 500 ₹80,000 | 680 ₹1,08,800 | 750 ₹1,20,000 | 950 ₹1,52,000 | 594 ₹95,040 | 700 ₹1,12,000 | 525 ₹84,000 |
| 2.00 | All as per Serial Item No. 01 here-in-before but for 3 pin 5/6Amp switch socket point, on independent board, complete all as specified. | 70 | Each Point | 395 ₹27,650 | 500 ₹35,000 | 680 ₹47,600 | 700 ₹49,000 | 950 ₹66,500 | 420 ₹29,400 | 750 ₹52,500 | 300 ₹21,000 |
| 3.00 | All as per Serial Item No. 01 here-in-before but for 3 pin 5/6Amp switch socket point, on same board, complete all as specified. | 90 | Each Point | 195 ₹17,550 | 120 ₹10,800 | 195 ₹17,550 | 125 ₹11,250 | 950 ₹85,500 | 420 ₹37,800 | 90 ₹8,100 | 250 ₹22,500 |
| 4.00 | All as per Serial Item No. 01 here-in-before but for one light point controlled by two two way switchs, complete all as specified. | 12 | Each Point | 425 ₹5,100 | 500 ₹6,000 | 850 ₹10,200 | 850 ₹10,200 | 950 ₹11,400 | 420 ₹5,040 | 890 ₹10,680 | 400 ₹4,800 |
| 5.00 | All as per Serial Item No. 01 here-in-before but for each additional light point on the same switch circuit, complete all as specified. | 80 | Each Point | 195 ₹15,600 | 150 ₹12,000 | 390 ₹31,200 | 390 ₹31,200 | 950 ₹76,000 | 420 ₹33,600 | 490 ₹39,200 | 400 ₹32,000 |
| 6.00 | All as per Serial Item No. 01 here-in-before but with 2.5Sqmm copper conductor cable and 2.5 Sqmm cable as earth continuity conductor for 3 pin 6/16Amp switch socket point, on independent board, complete all as specified. | 40 | Each Point | 595 ₹23,800 | 700 ₹28,000 | 995 ₹39,800 | 900 ₹36,000 | 1,150 ₹46,000 | 420 ₹16,800 | 990 ₹39,600 | 700 ₹28,000 |
| 7.00 | M&L for Circuit / Sub main wiring with two run of 2.5Sqmm FRLS PVC insulated unsheathed multi stranded, copper conductor single core cable, 1100 Volt, and one run of FRLS copper earth wire 2.5Sqmm drawn through and including suitable size PVC Casing & Capping with fittings, including taking down old submain wiring of any type, complete all as specified. Note: Copper conductor cable 2 run and one run of copper earth wire along with one run PVC Casing & Capping shall be measured as one length. | 300 | Running Meter | 75 ₹22,500 | 100 ₹30,000 | 180 ₹54,000 | 180 ₹54,000 | 330 ₹99,000 | 100 ₹30,000 | 270 ₹81,000 | 100 ₹30,000 |
| 8.00 | All as per Serial Item No. 7 here- in-before but for two runs of 4.0Sqmm and one run of 4.0Sqmm as earth wire. | 200 | Running Meter | 85 ₹17,000 | 166 ₹33,200 | 210 ₹42,000 | 200 ₹40,000 | 495 ₹99,000 | 90 ₹18,000 | 370 ₹74,000 | 100 ₹20,000 |
| 9.00 | All as per Serial Item No. 7 here- in-before but for two runs of 6.0Sqmm and one run of 6.0Sqmm as earth wire. | 150 | Running Meter | 225 ₹33,750 | 230 ₹34,500 | 315 ₹47,250 | 300 ₹45,000 | 665 ₹99,750 | 200 ₹30,000 | 410 ₹61,500 | 100 ₹15,000 |
| 10.00 | M&L for Circuit / Sub main wiring with two runs of 6.0Sqmm PVC FRLS insulated copper conductor cable, single core multi stranded 1100Volt along with one run of 6.0Sqmm as earth wire, drawn through existing conduit, concealed /surface type, including taking down old submain wiring of any type, complete all as specified and as directed. Note: Two runs of cable, one run of earth wire shall be measured as one unit. | 150 | Running Meter | 225 ₹33,750 | 275 ₹41,250 | 265 ₹39,750 | 170 ₹25,500 | 750 ₹1,12,500 | 120 ₹18,000 | 280 ₹42,000 | 100 ₹15,000 |
Tender Value
₹49 L
EMD Value
₹98,000
Closing Date
28 Apr 2026, 6:00 pmClosed
Garrison Engineer
Military Engineer Services Garrison Engineer Laxmi Tek Camp Belgaum
REPAIR, MAINTENANCE OF INTERNAL ELECTRIFICATION INCLUDING LED LIGHT FIXTERS, SWITCHES, SOCKETS, MODULAR SWITCH BOARDS, SUBMAIN WIRING AND CONNECTED ITEMS AT MLIRC RECORD, HQ JL WING PC ROHIDESHWAR CAMP AND RMS UNDER GE BELGAUM
2026_MES_758525_1
8723/E8
Open Tender
Electrical and Maintenance Works
330 days
Belgaum
Please refer tender documents
8 documents required · 8 mandatory
₹500
Garrison Engineer Belgaum
₹98,000
Yes
2 Jul 2026
30 Mar 2026
30 Apr 2026
30 Mar 2026
28 Apr 2026
14 Apr 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1M&L for Point wiring with 1.5 Sq.mm FRLSH PVC insulated unsheathed copper conductor cable, single core multi stranded 1100Volt grade conforming to IS 694: 1977, drawn in and including rigid PVC conduit not less than 20mm bore, concealed/surface type, medium grade as per IS 9537 (Part 1-1983) with conduit accessories, junction boxes, tees, terminal boxes with and including factory made modular metal / pvc boxes as required at site including modular cover plates (white) with frame for mounting modular switches, including one run of 1.5 Sq.mm single core FRLS PVC unsheathed copper conductor cable as earth continuity conductor and connected to common earth dolly, for one light / fan /bell point controlled by one way switch/MCB, including taking down old u/s point wiring of any type with fittings, complete all as specified and as directed. Note: Cutting chases and making good surfaces shall be included in the unit rate. | |||||
| - | All as per Serial Item No. 01 here-in-before but for 3 pin 5/6Amp switch socket point, on independent board, complete all as specified. | - | Each Point | - | - |
| - | All as per Serial Item No. 01 here-in-before but for 3 pin 5/6Amp switch socket point, on same board, complete all as specified. | - | Each Point | - | - |
| - | All as per Serial Item No. 01 here-in-before but for one light point controlled by two two way switchs, complete all as specified. | - | Each Point | - | - |
| - | All as per Serial Item No. 01 here-in-before but for each additional light point on the same switch circuit, complete all as specified. | - | Each Point | - | - |
| - | All as per Serial Item No. 01 here-in-before but with 2.5Sqmm copper conductor cable and 2.5 Sqmm cable as earth continuity conductor for 3 pin 6/16Amp switch socket point, on independent board, complete all as specified. | - | Each Point | - | - |
| - | M&L for Circuit / Sub main wiring with two run of 2.5Sqmm FRLS PVC insulated unsheathed multi stranded, copper conductor single core cable, 1100 Volt, and one run of FRLS copper earth wire 2.5Sqmm drawn through and including suitable size PVC Casing & Capping with fittings, including taking down old submain wiring of any type, complete all as specified. Note: Copper conductor cable 2 run and one run of copper earth wire along with one run PVC Casing & Capping shall be measured as one length. | - | Running Meter | - | - |
| - | All as per Serial Item No. 7 here- in-before but for two runs of 4.0Sqmm and one run of 4.0Sqmm as earth wire. | - | Running Meter | - | - |
| - | All as per Serial Item No. 7 here- in-before but for two runs of 6.0Sqmm and one run of 6.0Sqmm as earth wire. | - | Running Meter | - | - |
| - | M&L for Circuit / Sub main wiring with two runs of 6.0Sqmm PVC FRLS insulated copper conductor cable, single core multi stranded 1100Volt along with one run of 6.0Sqmm as earth wire, drawn through existing conduit, concealed /surface type, including taking down old submain wiring of any type, complete all as specified and as directed. Note: Two runs of cable, one run of earth wire shall be measured as one unit. | - | Running Meter | - | - |
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.53 MB
8723Tender.pdf
Tender Documents • 0.90 MB
8723Credit.pdf
Additional Documents • 0.18 MB
BOQ_849593.xls
BOQ • 0.47 MB
Download all tender documents and submit your bid