Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance SARCH GANDERBAL J K 191131 | GANDERBAL | JAMMU AND KASHMIR | 191131 | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
| 4 | Admitted-Finance | Admitted-Finance |
| 5 | Admitted-Finance | Admitted-Finance |
Tender Value
₹77,000
Closing Date
24 May 2021, 12:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer Jal Shakti Mech Div sgr
Executive Engineer Jal Shakti Mech Div sgr
Providing fitting of over current and earth fault relay to incoming and outgoing C R Panel of 2.5 MVA No 1 at WSS Tangnar Stage-2nd
2021_PHE_124468_2
(JSMDS-NIT No -(E-08 of 05/2021)
Open Tender
Electrical Works
Item Rate
10 days
WSS Tangnar
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
Exempted
29 May 2021
17 May 2021
24 May 2021
17 May 2021
24 May 2021
17 May 2021
90 days
Amount
Providing/Fitting of over current and Earth Fault relay to incoming and Outgoing C&R Panel of 2.5 MVA No 1 at WSS Tangnar Stage-2nd
Repairs to outgoing C&R panel of 2.5 MVA ACR by way of disconnecting the power supply to the sub-station and then extraction of on-functional over current and earth fault Relay from the C&R Panel. The job includes providing and fitting of new Over current and Earth fault Relay to C&R Panel of 33 KV VCB Panel. The job includes testing the over current and earth fault relay for all the protection of indications and tripping system. The OC/EF relay shall have following specifications Make- Ashida Electronics Type-SDR 141A ( Numerical type) Operating voltage-36DC High speed tripping Contacts-Hand reset ( HR) The job includes control wiring for connecting he over current and earth fault relay in the panel. All the tools and tackles including skilled labours involved in the execution of the job shall be arranged by the firm. The relay shall be tested on full load for all the protections and tipping system and shall be programmed as per the rating and capacity of electrical equipment installed.
Repairs to incoming C&R Panel of 2.5 MVA AVR by way of disconnecting the power supply to the sub-stations and then extraction of on-functional over current and Earth fault relay from the C&R Panel. The job includes providing and fitting of new Over current and earth fault Relay to C&R Panel of 33 KV VCB Panel. The job includes testing the over current and earth fault relay for all the protections of indications and tripping system. The OC/EF relay shall have the following specifications Make- Ashida Electronic Type-ADR 141a ( Numerical type) Operating voltage-36VDC High Speed tripping Contact-Hand reset ( HR) The job includes control wring for connecting the over current and earth fault relay in he panel. All the tools and tackles including skilled labour involved in the execution of the job shall be arranged by the firm. The relay shall be tested on full load for all the protections and tipping system and shall be programmed as per the rating and capacity of the electrical equipment installed.
M/s Shaheen Enterprises
M. G. ELECTRICALS
M/S YASIR ELECTRICAL and MECHANICAL WORKS
M/S MIR ELECTRICALS and MECHANICAL ENG WORKS
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .