| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹40.8 LAccepted-AOC | L1 | Accepted-AOC Accepted | |
| 2 | L2₹48.9 L+₹7.0 L (16.7%)Rejected-Finance | L2 | Rejected-Finance Being higher bid value | |
| 3 | L3₹49.8 L+₹7.9 L (18.7%)Rejected-Finance 51 1 FULBAGAN ROAD BAGHAJATIN KOLKATA 700086 WEST BENGAL | KOLKATA | WEST BENGAL | 700086 | L3 | Rejected-Finance Being higher bid value | |
| 4 | L4₹50.2 L+₹8.3 L (19.8%)Rejected-Finance | L4 | Rejected-Finance Being higher bid value | |
| 5 | L5₹51.7 L+₹9.8 L (23.3%)Rejected-Finance 10 1 GROUND FLOOR WEST GHOSH PARA JAGATDAL JAGATDAL JAGATDAL NORTH 24 PARGANAS WEST BENGAL 743125 | 24 PARAGANAS NORTH | WEST BENGAL | 743125 | L5 | Rejected-Finance Being higher bid value |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
9 Feb 2023, 6:00 pmClosed
GE ALIPORE KOLKATA
NO 1 NATIONAL LIBRARY AVENUE, ALIPORE, KOLKATA 700027
REPAIR/MAINT OF LT PANEL AND STREET LIGHTS AND ALLIED WORKS AT CH (EC) UNDER GE ALIPORE KOLKATA
2022_MES_561727_2
GE/ALP (8096B) OF KOLKATA 2022-23
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE ALIPORE KOLKATA
Class D and category b (i)
9 documents required · 9 mandatory
₹500
GARRISON ENGINEER ALIPORE
₹90,000
Yes
18 Feb 2023
25 Jan 2023
10 Feb 2023
25 Jan 2023
9 Feb 2023
2 Feb 2023
Amount
Supply and fixing LED street light fitting 70 Watt 230 V AC outdoor type with high pressure diecast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and as directed. (Make : Havells Cat No EBDURAOMNIPLUSSL70WLED 757SASYTOPC.or equvalant in Phillips and CROMPTON).
Supply and fixing LED street light fitting 120 Watt 230 V AC outdoor type with high pressure diecast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and as directed. (Make HAVELLS EBDURAOMNIPLUSSL120WLED 757SASYTOPC.or equvalant in Phillips and CROMPTON).
Material and labour for replacement of thermoplastic cable junction box with knockouts for cable entry upto 25 sqmm including minimum 4 terminals for terminating cables (Cat No: K 9255 of make: Hensel or equivalent in make: Sintex) including fixing arrangement by carefully cutting the bases of pole or post top lantern or other wise as indicated complete all as specified and as directed.
Supply and fixing Steel tubular swaged poles complet with cast iron base plate, finial taper plug, bolts, nuts and screws as specified type 410 SP-22 (8.5 metres long) complete all as specified and as directed.
Supply and fixing LED flood light 70 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp complete all as specified and as directed. (Make Crompton Cat No.LFL-70-CDL/60M or equvalant in PANASONIC and Phillips HAVELLS)
Labour only for checking of unserviceable street light fitting over poles, finding of faults and repair/ replacement of unserviceable spares like lamp, holder, ignitor, ballast, connector block etc and making the light functional in all respect including necessary tools requirment for repair complete all as specified and as directed. [Note: - (i) All the spares required for repair will be measured and paid under separate item of this schedule as 'Supply only'. (ii) Necessary tools required for repair deemed to be included in the quoted rate. (iii) Cost of short pieces of copper conductor for internal wiring in between holders, ballast, ignitors and other accessories housed in the same light fitting deemed to be included in the quoted rate]
All as per Item Ser No 6 here in before but for post top lanterns, outdoor bracket lights and flood lights complete all as specified and as directed.
Supply only driver for LED luminaires upto 24 watt (of make: Philips, driver type: BRP320 POT Spare LED Driver or equivalent in Bajaj/ Crompton Greaves/ Havells) complete all as specified and as directed.
Supply only driver for LED luminaires upto 36 watt (of make: Philips, driver type: BRP409 Spare LED Driver or equivalent in Bajaj/ Crompton Greaves/ Havells. complete all as specified and as directed)
Supply only driver for LED luminaires upto 75 watt (of make: Philips, driver type: XITANIUM 75W 0.70A 1-10V INT-Y SXT or equivalent in Bajaj/ Crompton Greaves/ Havells) complete all as specified and as directed.
Supply only driver for LED luminaires upto 150 watt (of make: Philips, driver type: SPARE DRIVER XTE 150W 700 mA NTC or equivalent in Bajaj/ Crompton Greaves/ Havells) complete all as specified and as directed.
Material and labour LED Post Top Lantern 40 watt for 360O indirect lighting with glare free milky white side covers and IP65 grade protection (Cat No: LPTO-40-CDL/M of make: Crompton Greaves or equivalent in Philips/ Bajaj/ Havells) including taking out of old light fitting complete all as specified and as directed.
Material and labour for cement concrete type B1 (1:2:4) with 20 mm graded stone aggregate as in roof kerbs or mud stops, rounded or chamfered on edges complete all as specified and as directed.
Material and labour for Galvnized steel tubluler light gead 40 mm pipe not less then 1.5 mtr suitable for street light bracket with all fixing arrangment complete all as specified and as directed.
Supply & fixing BAMBOO LED BOLLARD,Aluminium landscape IP 65 luminaire for diffuseed lighting with high power LED as light source. complete with all accessories, prewired and flexible wire twin core from terminal block and mounted on cement concreet foundation not less the 1 feet hight. complete all as specified and as directed. (Make-HAVELLS Cat No- BAMBOOBL8WLED830SS YMTOPCM or equivalent in phillpes or Magik)
Cleaning roof top of MES Installations with wire brush including removing of vegetations complete all as specified and as directed. (Area 20 Sqm approx)
Material and labour for bush cutting and cleaning of area in and around of E/M installations for the following areas: -
Sub-Station No 2 (Area 20 Sqm approx)
Sub-Station No 3 (Area 200 Sqm approx)
Sub-Station No 4 (Area 40 Sqm approx)
Sub-Station No 5 (Area 150 Sqm approx)
Sub-Station No 7 (Area 100 Sqm approx)
Sub-Station No 8 (Area 100 Sqm approx)
Sub-Station No 9 (Area 40 Sqm approx)
Sub-Station No 10 (Area 40 Sqm approx)
Servicing of Air Circuit Breaker AC three phase 415 volt, 50 Hz, 800 Amp to 1600 Amp including taking shut down and racking out the complete assembly, cleaning of all the parts by air blower, applying suitable chemical (CRC), greasing of all moving parts, checking resistance of all the contact points and refixing the same in original position complete all as specified and as directed.
Taking out of old PCC / steel tubular pole of 9 mtr height and installing the pole in other location complete all as specified and as directed. [Note: Earth work and PCC will be measured and paid under separet item of this schedule]
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft/ loose soil complete all as specified and as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers n.exc 25 cm. in any type of soil complete all as specified and as directed.
Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point in any type of soil complete all as specified and as directed.
Material and Labour for dry river Sand filling in trenches including punning down consolidation in soft/ loose soil complete all as specified and as directed.
Material and Labour for tubes, 'light grade', galvanised, with all fitting; laid in trenches for cable/ earth lead protection of the following sizes: -
80 mm dia nominal bore
50 mm dia nominal bore
40 mm dia nominal bore
Material and labour for brick protection of cables in trenches with old size sub-class 'B' bricks complete all as specified and as directed.
Relaying of old useful bricks as retrieved during taking out of old LT UG cable complete all as specified and as directed.
Material and labour for cutting of existing bituminous metal road for laying of cables including demolition of road surface, excavation from bottom level of road upto a depth of 0.55 m from road surface and returning filling of excavated earth and making good the road surface with PCC type C2 (1:3:6) with 40 mm graded stone aggregate upto a depth of 10 cm from road surface and removing of excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point in any type of soil complete all as specified and as directed. [Note: Laying of cable/ protection pipe will be measured and paid under separate item of this schedule]
Taking out of old LT UG cable 1100 volts grade complete all as specified and as directed for the following size of cables :-
400 sqmm 3.5 core
240 sqmm 3.5 core
185 sqmm 3.5 core
95 to 120 sqmm 3.5 core
50 sqmm 3.5 core
25 to 35 sqmm 3.5 core
10 to 16 sqmm 2/4 core
Supply and Laying XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade complete all as specified and as directed for the following size of cables: -
400 sqmm 3.5 core
240 sqmm 3.5 core
185 sqmm 3.5 core
120 sqmm 3.5 core
95 sqmm 3.5 core
50 sqmm 3.5 core
35 sqmm 3.5 core
25 sqmm 3.5 core
16 sqmm 4 core
10 sqmm 2 core
Material and labour for MCCB 4 pole, 415 V, 100 Amp, 36 kA Cat No: CM 9791900K20G )of make: L&T or equivalent) including taking out of old one complete all as specified and as directed.
Material and labour for MCCB 4 pole, 415 V, 125 Amp, 36 kA Cat No: CM 9068100L00G (of make: L&T or equivalent) including taking out of old one complete all as specified and as directed.
Material and labour for MCCB 4 pole, 415 V, 160 Amp, 25 kA Cat No: CM9063800NO including Spreader terminals (Cat No: CM92007OOOO of make: L&T or equivalent in Legrand/ Schneider/ ABB) including taking out of old one complete all as specified and as directed.
Material and labour for MCCB 4 pole, 415 V, 250 Amp, 36kA (Cat No: CM92151OOOOX1 of make: L&T or equivalent) including taking out of old one complete all as specified and as directed.
Material and labour for MCCB 4 pole, 415 V, 400 Amp, 36kA (Cat No: CM93003OOOOX1 of make: L&T or equivalent) including taking out of old one complete all as specified and as directed.
Material and labour for MCCB 4 pole, 415 V, 63 Amp, 25 kA (Cat No: Cat No:CM91712OOHOOG of make: L&T or equivalent in Legrand/ Schnieder/ ABB) including taking out of old one complete all as specified and as directed.
Material and labour for MCCB Spreader Terminals 2 Pole (Cat No: Cat No:CM9909640000 of make: L&T or equivalent in Legrand/ Schnieder/ ABB) including taking out of old one complete all as specified and as directed.
Material and labour for MCCB Spreader Terminals 3 Pole (Cat No : CM9909640000 of make: L&T or equivalent in Legrand/ Schnieder/ ABB) including taking out of old one complete all as specified and as directed.
Material and labour for MCCB Spreader Terminals 4 Pole (Cat No: Cat No:CM9909640000 of make: L&T or equivalent in Legrand/ Schnieder/ ABB) including taking out of old one complete all as specified and as directed.
Cable jointing kit for 11 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 16 sqmm to 35 sqmm complete all as specified and as directed.
Cable jointing kit for 11 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 sqmm to 90 sqmm complete all as specified and as directed.
Cable jointing kit for 11 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sqmm to 185 sqmm complete all as specified and as directed.
Material and labour for Mild steel plates, plain or chequered, 5mm thick or over in thickness in available sizes for use as duct covers as per existing size including taking out of old one all as specified and as directed.
Maintenance of LT distribution panel after taking proper shutdown including cleaning of enclosure with dry cloth and cleaning of contact points with suitable electrical contact cleaning agent and clean dry cloth, checking of tightness of all the contact points, replacement of defective/ burnt out lugs and bolts & nuts and reporting of major defects if any found during maintenence complete all as specified and as directed for the following: -
LT panel with Incoming ACB upto 1600 Amp 1 No and outgoing MCCBs upto 630 Amp 4 pole upto 8 Nos and Changeover if any
LT panel with Incoming MCCB upto 800 Amp 1 No and outgoing MCCBs upto 400 Amp 4 pole upto 8 Nos, all MCBs, Changeover if any
LT feeder pillar box with Incoming MCCB upto 400 Amp 1 No and outgoing MCCBs upto 250 Amp 4 pole upto 8 Nos and all MCBs
Material and Labour for Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc as required 32x6mm galvanised iron strip including taking out of old strip complete all as specified and as directed.
Material and Labour for Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex head screw including taking out of old one complete all as specified and as directed.
Material and labour for earthing complete with galvanised iron earth plate electrode 600 mm x 600 mm x 6 mm thick, burried directly and preferably vertically in ground, earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 m below ground level connetced with galvanised strip of size 32 x 6 mm by means of nuts, bolts, check nuts and washers made of galvanised iron or steel earthing lead to be protected by galvanised iron pipe 40 mm bore (light grade) and other end connected to earthing test point or lightening arrestor or main controlling switch as directed including providing funnel with 20mm bore galvanised iron pipe (medium grade), wire mesh, charcoal or coke and common salt in alternate layer of 15cm (compacted thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1 (with 20mm graded aggregate), 50mm thick precast RCC (1:2:4) cover slab (re-inforced with 8mm dia TMT bar @ 15 cm C/C bothways and suitable handle made of 10mm dia) including necessary earth work in excavation, returning filling and removal of surplus earth upto a distance not exceeding 50 m etc all as shown on electrical plate No. 3 of MES Schedule Part-I(2009) complete including testing on complete all as specified and as directed by the Engr-in-Charge.
All as per item No 47 here in before but with GI wire of 4mm dia as earthing lead
Cable Iugs,aluminum of following sizes :
Material and labour for Painting of LT Pole after preparation of old painted surface and painting with two coats of aluminium paint for the entire pole and yellow and black colour synthetic enamel paint in 2 Nos alternate layers of 32 mm high at the bottom of each pole including taking proper precautionary measure for disconnecting electric supply and writing existing pole Number with white enamel synthetic paint complete all as specified and as directed.
Material and labour for Painting of pipes of Post Top Lanterns after preparation of old painted surface and painting with two coats of synthetic enamel paint of approved colour including taking proper precautionary measure for disconnecting electric supply complete all as specified and as directed.
Material and labour for Painting of LT Panel / MES equpment after preparation of old painted surface and painting with two coats synthetic enamel paint With spray painting of approved colour including taking proper precautionary measure for disconnecting electric supply complete all as specified and as directed.
Supply and fixing insulating LT synthetic rubber mat of size 1 m x 2 m x 2 mm thick class A as per IS: 15652 (2006) complete all as specified and as directed.
Taking out cable loop after cable ends from panels, cutting/removing heated cable ends with burnt ligs and inserting new lugs after cutting opening of fresh cable end complete including earth work and relaying cable around for cable size 70 to 185 sqmm. complete all as specified and as directed.
Expertise and labour only for load balancing of feeder complete after removing all service cables connected to all three phase , checking these for ohmic value, leakage if any and connecting to all the three phases in such a sequence so that is nearly balanced in all the three phase complete all as specified and as directed.
Supply only in replacement pole mountable (Timer switch for street lights) sensor based, astronomical and type timer with Nature switch-02, power contactor for load switching, MCB, and terminal block, including complete with mounting brackets, cable glands, openable door with lock and key. The enclosure made of UV stablizer, FR grade special moulding compound to provide a rust proof, electric shock proof, termite proof outdoor mountable electrically insulating body capable of enduring solar radiation in the outdoor. complete all as specified and as directed. (Model/Make No:- SWADEEP-02 EC 5 KW 3P (Three phase) or equivalent in L&T/ABB/Legrand)
PUTUL CONSTRUCTION CO.
NUPUR CONSTRUCTION
GAYATRI ENTERPRISE
RADHA ENTERPRISE
MASTER BUILDERS
KAMAKHYA TRADERS
S B ENTERPRISE
CHATTERJEE CONSTRUCTION
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .