Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.1 CrAccepted-AOC 4B TOWN SQUARE CHINAR PARK RAJARHAT KOLKATA 700 136 | ₹11.1 Cr | L1 | Accepted-AOC Work Order Issued |
| 2 | L2₹11.3 CrRejected-AOC | ₹11.3 Cr | L2 | Rejected-AOC L2 |
Tender Value
₹11.1 Cr
EMD Value
₹22.1 L
Closing Date
6 Mar 2024, 3:00 pmClosed
CE, PWD(Bldg), Assam, Chandmari, Ghy-3
O/O The CE, PWD(Bldg), Assam, Chandmari, Ghy-3
Additional work for the Construction of New (Ten storied Plus two basement of parking) office building for establishment under the Commissioner of Taxes,Assam, Dispur, Guwahati-6
2024_PWBNH_36663_1
CS/CE/BLD/ELECT/59/2023 2024/11 Dated 22-02-2024
Open Tender
Electrical Works
180 days
Guwahati
Please refer Tender documents.
5 documents required · 5 mandatory
₹22,122
₹22.1 L
Yes
30 Jan 2025
26 Feb 2024
6 Mar 2024
26 Feb 2024
6 Mar 2024
26 Feb 2024
Amount
Providing, supplying and fixing in place COMMISIONER Side TABLE Model: HobbitTable Size: L 660 x 410D x 460 mm Ht Wooden coffee table Wooden legs Magazine shelf
Providing, supplying and fixing in place ADDL. COMMISIONER TABLE Model: Elite Size: 2200 x 950 x 760 Extention: 1900 x 600 x 620 1.E1 grade particle board with imported ""Schattdecor"" melamine finish. 2. Fixed side return with 2 drawers, single swing door, open shelf and open space for CPU, with holes for customer put their sockets. 3. Fixed side return 4. Wirebox on table top, with cover for wire entrance only. 5. Unique leg design dept.
Providing, supplying and fixing in place ADDL. COMMISIONER CHAIR MODEL: LIBERATE HB Base: The 640mm dia (26 inches) five pronged base is made out of GF nylon – Reinforced with bottom ribbing for additional buttress and strength. Tested prudently and rigorously as perCastors - Twin Castors 50mm dia castors compling toANSI / BIFMA X 5.1 – 2002 Gaslift: Class 4 tested -ANSI BIFMA performance standardsSeating Structure: Seat and back is made out of 12mm molded hotpressed plywood in ergonomic shape fitted with Imported T-nuts andrevited in to the wood Upholstery: Upholstery: Cushion ith premoulded foam of 50 - 60 density in the shape of plywood. Density -- 52 kg/m3 Hardness -- 12.6kgf at 25% Mechanism: Distinctively and characteristically designed tiltmechanism offering a very smooth and fluidic reclining motion with tension adjust knob and importantly offering seat to back recline ratioof 3:7, optimal for good back support.Multilock mechanism is fabricated from Sheets, undergo through CO2 welding processimparting uniform surface finish and tensile Sheets, undergo through CO2 welding process imparting uniform surface finish and strength.The components are processed with high degree of precision and careso as to assemble with other parts in perfect harmony to give smoothand effortless reclining experience. Tension springs are made outGrade II material conforming to Indian Standards. Also provided withrelease levers for locking mechanism and height adjustment of seat.Mechanism aides to operate the height adjustment, and has beenequipped with 4 locking positions, back rest “ Return Prevention”function .The chair back sways sideways along with the body movement.
ADDL. COMMISIONER VISITOR'S CHAIR MODEL: CONTACT PROJECT VA Frame The frame is made out of 25.4mm tube of 16 gauge tube confirming to IS-7138-1973, Welded by Co2 welding process for uniform surface finish. Powdercoating: Thermo set powder coating epoxy polyester hybrids of hardness (pencil) H.B.74 and impact resistant (in lab) 60-160 kgs cm and to a thickness of 40-50 microns is carried out of 7 step pretreatment process. Fasteners: High quality metal hardware conforming to Hardness 38-44 and tensile strength – 1300 n/mm. IS 1363-1967 Seating Structure: Seat is made out of 12mm molded hot pressed plywood in ergonomic shape fitted with Japanese T-nuts and riveted into the plywood Upholstery: Upholstery: Cushion with pre moulded foam of 50 - 60 density in the shape of plywood. Density -- 52 kg/m3 Hardness -- 12.6kgf at 25% Armrest: Polypropylene injection moulded armrests - Fixed Arms Back: Mesh Back on Frame. Fabric : Seat are duly upholstered with approved fabric
Providing, supplying and fixing in place ADDL. COMMISIONER SOFA Model: E007 SOFA MADE OFF SOLID WOOD FRAME, SUPPORTED WITH HIGH CLASS WEBBING BELT, 40/32/40 DENSITY FOAM USED ON SEAT AND BACK, EXTRA 2” FOAM COVERED ON SEAT FOR EXTRA COMFORT, BOTTOM FRAME MADE OF SOLID WOOD AND POLISHED WITH NATURAL WOOD POLISH, LEGS ARE MADE OF METAL AND POWER COATED IN BLACK, SOFA UPHOLSTERY DONE EITHER IN RESPONSE STYLO SHADE CARD OR FEATHERLITE GENESIS FABRIC. 3 Seater: 1930 x 880 x 840 H
Providing, supplying and fixing in placeADDL. COMMISIONER SOFA Model: E007 SOFA MADE OFF SOLID WOOD FRAME, SUPPORTED WITH HIGH CLASS WEBBING BELT, 40/32/40 DENSITY FOAM USED ON SEAT AND BACK, EXTRA 2” FOAM COVERED ON SEAT FOR EXTRA COMFORT, BOTTOM FRAME MADE OF SOLID WOOD AND POLISHED WITH NATURAL WOOD POLISH, LEGS ARE MADE OF METAL AND POWER COATED IN BLACK, SOFA UPHOLSTERY DONE EITHER IN RESPONSE STYLO SHADE CARD OR FEATHERLITE GENESIS FABRIC. 1 Seater: 900 x 880 x 840 H
Providing, supplying and fixing in place Model: STO 90210 900L X 450D X 2100HT Specification: The storage top 25mm thick, shutter & sides panel are made of 18mm thick & back panle is made of 09mm thick prelaminated particle board of approved shade. All the edges of storage surface shall be provided with machine pressed imported PVC lipping glued with hotmelt Eva glue free from any VOC.with finger groove handle & suitable (no visible handles) lock.All exposed area PVC edge lipping.
Providing, supplying and fixing in place Model: STO 90120 900L X 450D X 1200HT Specification: The storage top 25mm thick, shutter & sides panel are made of 18mm thick & back panle is made of 09mm thick prelaminated particle board of approved shade. All the edges of storage surface shall be provided with machine pressed imported PVC lipping glued with hotmelt Eva glue free from any VOC.with finger groove handle & suitable (no visible handles) lock.All exposed area PVC edge lipping.
Providing, supplying and fixing in place JCT TABLE Model HT 501- A Size: 2200 x 800 x 750 Ht Side Unit: 1010 W x 500 D x 650 H Specification: Material: MDF + particle board of 50 mm thickness. Surface finsish: Melamine Wire manager included. Color: Dark walnut
Providing, supplying and fixing in place JCT Back Unit Model HT 325 Size: 1800 x 400 D x 2000 H Specification: Material: MDF + particle board of 50 mm thickness. Surface finsish: Melamine Wire manager included. Color: Dark walnut
Providing, supplying and fixing in place JCT SOFA MODEL: INTERACT - 3 SEATER MADE OFF : THE SOFA IS MADE OF FINE QUALITY LEATHERRITE (3s = 8.0 mtr, 2s = 6.8 mtr, 1s= 5.3 mtr), THE STRUCTURE IS MADE FROM SILVER WOOD & PINE WOOD, 32 & 40 DENSITY FOAM IS USED WHICH IS COVERED WITH ROLL POLY FILLING FOR GIVING COMFORT AND EXTRA SOFTNESS TO SOFA. EXTRA MATERIAL USED FOR 902 SOFA ELASTIC NEVAR BELT, STAPLER PINS LEGS : ARE MADE OF STAINLESS STEEL SIZE : 1800 W X 710 D X 780 H 3 SEATER
Providing, supplying and fixing in place JCT SOFA MODEL: INTERACT - 1 SEATER MADE OFF : THE SOFA IS MADE OF FINE QUALITY LEATHERRITE (3s = 8.0 mtr, 2s = 6.8 mtr, 1s= 5.3 mtr), THE STRUCTURE IS MADE FROM SILVER WOOD & PINE WOOD, 32 & 40 DENSITY FOAM IS USED WHICH IS COVERED WITH ROLL POLY FILLING FOR GIVING COMFORT AND EXTRA SOFTNESS TO SOFA. EXTRA MATERIAL USED FOR 902 SOFA ELASTIC NEVAR BELT, STAPLER PINS LEGS : ARE MADE OF STAINLESS STEEL 750 W X 710 D X 780 H 1 SEATER
Providing, supplying and fixing in place DCT Model: FST MT 21090 Specification: MAIN TABLE: 2100W X 900D X 750HT Side Table: 1500 x 450D x 750 Ht Table top: Made of 25mm thick prelaminated particle board of approved shade. All the edges of cabin table surface shall be provided with machine pressed 2mm thick imported PVC lipping glued with hotmelt Eva glue free from any VOC. Modesty Panel: 18/12mm thick 450mm ht plt modesty panel is considered.Wich is machine pressed 2mm thick imported PVC lipping glued with hotmelt Eva glue free from any VOC. Under Structure Support: 25mm thick PLT gable end. Wire Management : Grommet Hole provided on table top. Mobile Pedestal Pedestal are made of 18mm thick prelaminated particle board of approved shade. All the edges of pedeatal surface shall be provided with machine pressed 2mm thick imported PVC lipping glued with hotmelt Eva glue free from any VOC. With 2 drawer units and 1 filling folder unit. The drawer units are provided with finger groove handle(No visible handles) and suitable locks. Trolley for UPS .
Providing, supplying and fixing in place ST, ACT Model: FST MT 18090 Specification: MAIN TABLE: 1800W X 900D X 750HT Side Table: 1500 x 450D x 750 Ht Table top: Made of 25mm thick prelaminated particle board of approved shade. All the edges of cabin table surface shall be provided with machine pressed 2mm thick imported PVC lipping glued with hotmelt Eva glue free from any VOC. Modesty Panel: 18/12mm thick 450mm ht plt modesty panel is considered.Wich is machine pressed 2mm thick imported PVC lipping glued with hotmelt Eva glue free from any VOC. Under Structure Support: 25mm thick PLT gable end. Wire Management : Grommet Hole provided on table top. Mobile Pedestal Pedestal are made of 18mm thick prelaminated particle board of approved shade. All the edges of pedeatal surface shall be provided with machine pressed 2mm thick imported PVC lipping glued with hotmelt Eva glue free from any VOC. With 2 drawer units and 1 filling folder unit. The drawer units are provided with finger groove handle(No visible handles) and suitable locks. Trolley for UPS
Providing, supplying and fixing in place DCT, ACT, ST CHAIR MODEL: ASTRO HB Base: The 640mm dia (26 inches) five pronged base is made out of GF nylon – Reinforced with bottom ribbing for additional buttress and strength. Tested prudently and with bottom ribbing for additional buttress and strength. Tested prudently and rigorously as per ANSI/BIFMA X5.1-2011 General Purpose Office Chair Standards Castors - Twin Castors 50mm dia castors compling to ANSI / BIFMA X 5.1 – 2002 Gaslift - Class 4 tested -ANSI BIFMA performance standards Seating Structure: Seat and back is made out of 12mm molded hot pressed plywood in ergonomic shape fitted with Imported T-nuts and revited in to the wood Upholstery: Cushion with pre moulded foam of 50 - 60 density in the shape of plywood. Density -- 52 kg/m3 Hardness -- 12.6kgf at 25% Mechanism: This mechanism is manufactured out of cold Rolled Carbon Steel IS 513-1994 Sheets,The steel components are manufactured with highly precision tools accuracy in matching other parts for smooth functioning. The steel components are fabricated by using Co2 welding process for giving uniform surface finish with higher tensile strength. Springs are made out of Grade II material. Composite release levers for locking mechanism & Gas lift height adjustment. Release lever mechanism for Locking and Gas lift height adjustment. Headrest: Adjustable Headrest Back: Back Frame is upholstered with Thinner Mesh Adjustable Lumbar Support Allows you to adjust the lumbar support position for good back support and blood circulation Armrest: Moulded self skinned polyurethene Arms confirming to IS 7078 with steel insets for long life. one way adjustable - Height Adjustable.Tension Control : Tension control is below the Seat Fabric: Seat are duly upholstered with approved fabric
Providing, supplying and fixing in place DCT, ACT, ST VISITOR'S CHAIR MODEL: SMART VA Legs:Powdercaoted 4 Legs Back: Tinner Mesh Back Seating Structure: Seat is made out of 12mm molded hot pressed plywood in ergonomic shape fitted withImported T - nuts and revited in to the wood Upholstery: Upholstery: Cushion with pre moulded foam of 50 - 60 density in the shape of plywood. Density -- 52 kg/m3 Hardness -- 12.6kgf at 25% Back: Moulded Polypropylene back with netted fabric upholstred Armrest: These arms are made out of polypropylene injection molding component which offers the smooth finishes and Scratch resistance. Fixed Arms Fabric: Seat are duly upholstered with approved fabric
Providing, supplying and fixing in place DCT, ACT SOFA SOFA Model: Pearl 238 1 Seater: 780 (W) x 725 (D) X 700 (H) 2 Seater: 1275 (W) x 725 (D) X 700 (H) 3 Seater: 1800 (W) x 725 (D) X 700 (H) MADE OFF: THE SOFA IS MADE FOR FINE QUALITY LEATHERITE (3s = 7 mtr, 2s = 5.5 mtr, 1s= 4.5 mtr), THE STRUCTURE IS MADE FROM SILVER WOOD & PINE WOOD , 32 & 40 DENSITY FOAM IS USED WHICH IS COVERED WITH SOFTY FOAM AND ROLL POLY FILLING FOR GIVING COMFORT AND EXTRA SOFTNESS TO SOFA. EXTRA MATERIAL USED FOR 238 SOFA è ELASTIC NEVAR BELT, STAPLER PINS
Providing, supplying and fixing in place IT TABLE Specifications: Table top: Made of 25mm thick prelaminated particle board of approved shade. All the edges of cafeteria table surface shall be provided with machine pressed 2mm thick imported PVC lipping glued with hotmelt Eva glue free from any VOC. Under Structure - Table top is supported on MS Powder coated Square perform Legs which is constructed by 50 x 50 mm Sq-1.6g ERW tube acts as vertical member & supporting MS cross beam, which is made of 40 x 20 x 1.6 gauge rectangular tube and connected to legs with aluminium die cast wing connectors. Wire Management - 70mm thick, 250mm HT Raceway with laminate facia on main spine BTT provided with separator for data and power cables. Grommet Hole and vertebra for wire intake from floor is considered. Mobile Pedestal Pedestal are made of 18mm thick prelaminated particle board of approved shade. All the edges of pedeatal surface shall be provided with machine pressed 2mm thick imported PVC lipping glued with hotmelt Eva glue free from any VOC. With 2 drawer units and 1 filling folder unit. The drawer units are provided with finger groove handle(No visible handles) and suitable locks. Trolley for UPS Model : PER MT 18090 MAIN TABLE: 1800W X 750D X 750HT "
Providing, supplying and fixing in place IT CHAIRS Model: Contact Project MB Base: The 640mm dia (26 inches) five pronged base is made out of GF nylon – Reinforced with bottom ribbing for additional buttress and strength. Tested prudently and rigorously as per ANSI/BIFMA X5.1-2011 General Purpose Office Chair Standards Castors: Twin Castors 50mm dia castors compling to ANSI / BIFMA X 5.1 – 2002 Gaslift - Class 4 tested -ANSI BIFMA performance standards Seating Structure: Seat and back is made out of 12mm molded hot pressed plywood in ergonomic shape fitted with ImportedT-nuts and revited in to the wood Upholstery: Upholstery: Cushion with h pre moulded foam of 50 - 60 density in the shape of plywood. Density -- 52 kg/m3 Hardness -- 12.6kgf at 25% Synchro Mechanism: This mechanism is manufactured out ofcold Rolled Carbon Steel IS 513-1994 Sheets,The steel components are manufactured with highly precision tools Foraccuracy in matching other parts for smooth functioning. The steel components are fabricated by using Co2 welding processfor giving uniform surface finish with higher tensile strength.Springs are made out of Grade II material. Composite release levers for locking mechanism & Gas lift height adjustment.Release lever mechanism for Locking and Gas lift height adjustment. Tension Control: Tension control is below Seat Armrest: Polypropylene injection moulded armrests - Adjustable Arms Back: Mesh Back on Frames Fabric: Seat are duly upholstered with approved fabric
Providing, supplying and fixing in place JR Assistant, Sr Assistant, OS, Help desk TABLE, Assistant, PA, Internal Auditor Model: PER MT 15060 MAIN TABLE: 1500W X 600D X 750HT Specifications: Table top: Made of 25mm thick prelaminated particle board of approved shade. All the edges of cafeteria table surface shall be provided with machine pressed 2mm thick imported PVC lipping glued with hotmelt Eva glue free from any VOC. Under Structure - Table top is supported on MS Powder coated Square perform Legs which is constructed by 50 x 50 mm Sq-1.6g ERW tube acts as vertical member & supporting MS cross beam, which is made of 40 x 20 x 1.6 gauge rectangular tube and connected to legs with aluminium die cast wing connectors. Wire Management - 70mm thick, 250mm HT Raceway with laminate facia on main spine BTT provided with separator for data and power cables. Grommet Hole and vertebra for wire intake from floor is considered. Mobile Pedestal Pedestal are made of 18mm thick prelaminated particle board of approved shade. All the edges of pedeatal surface shall be provided with machine pressed 2mm thick imported PVC lipping glued with hotmelt Eva glue free from any VOC. With 2 drawer units and 1 filling folder unit. The drawer units are provided with finger groove handle(No visible handles) and suitable locks. Trolley for UPS
Providing, supplying and fixing in place JR ASSISTANT, SR ASSISTANT, HELP DESK, CASHIER ROOM, PA & ASSISTANT ROOM Model: Smart MB Base: The 630mm dia (25 inches) five pronged base is made out of GF nylon – Reinforced with bottom ribbing for additional buttress and strength. Tested prudently and rigorously as per ANSI/BIFMA X5.1-2011 General Purpose Office Chair Standards Castor: Castors - Twin Castors 50mm dia wheel made of castors compling to ANSI / BIFMA X 5.1 – 2002 Gaslift - Class 4 tested -ANSI BIFMA performance standards Seating Structure: Seat is made out of 12mm molded hot pressed plywood in ergonomic shape fitted with Imported T-nuts and revited in to the wood Upholstery: Cushion with pre moulded foam of 50 - 60 density in the shape of plywood. Density -- 52 kg/m3 Hardness -- 12.6kgf at 25% Mechanism: This mechanism is manufactured out of cold Rolled Carbon Steel IS 513-1994 Sheets,The steel components are manufactured with highly precision tools For accuracy in matching other parts for smooth functioning. The steel components are fabricated by using Co2 welding process for giving uniform surface finish with higher tensile strength. Springs are made out of Grade II material. Composite release levers for locking mechanism & Gas lift height adjustment. Release lever mechanism for Locking and Gas lift height adjustment. Back: Moulded Polypropylene back with netted fabric upholstred Arm rest: These arms are made out of polypropylene injection molding component which offers the smooth finishes and Scratch resistance. Fixed Arms Fabric : Seat are duly upholstered with approved fabric
Providing, supplying and fixing in place CONFERENCE REVOLVING CHAIR Model: Amaze MB Base: The 640mm dia (26 inches) five pronged base is made out of GF nylon Reinforced with bottom ribbing for additional buttress and strength. Tested prudently and rigorously as per ANSI/BIFMA X5.1-2011 General Purpose Office Chair Standards Castors - Twin Castors 50mm dia castors compling to ANSI / BIFMA X 5.1 – 2002 Gaslift - Class 4 tested -ANSI BIFMA performance standards Upholstery: Seat Cushion with pre moulded foam of 50 - 60 density Density -- 52 kg/m3 Hardness -- 12.6kgf at 25% Mechanism: Self Calibrating Multilock Mechansim Tested as per BIFMA Standards. Back Frame is inserted with Mesh & Dynamic Adaptable Lumbar Support Tension control is below the Seat. Armrest: Moulded polyurethene Arms confirming to IS 7078 with steel inserts for long Moulded self skinned polyurethene Arms confirming to IS 7078 with steel insets for long life. one way adjustable - Height Adjustable. Fabric: Seat is duly upholstered with approved fabric
Providing, supplying and fixing in place MEETING TABLE VC ROOM & AHU Rooms Model : FST MT 360120 SIZE: 3600W X 1200D X 750MM HT TABLE TOP Specification: Table top: Made of 25mm thick prelaminated particle board of approved shade. All the edges of meeting table surface shall be provided with machine pressed 2mm thick imported PVC lipping glued with hotmelt Eva glue free from any VOC. Under Structure Support: 25mm thick PLT gable end. Modesty Panel: 18mm thick 450mm ht plt modesty panel is considered.Wich is machine pressed 2mm thick imported PVC lipping glued with hotmelt Eva glue free from any VOC. Wire Management: 300mm Anodised flip up Made of Aluminum in anodised finish, which has soft closure and three way wire acess & PVC cable dump. Vertebra for wire entry.
Providing, supplying and fixing in place MEETING TABLE Meeting Room 5th Floor Model : FST MT 300120 SIZE: 3000W X 1200D X 750MM HT TABLE TOP Specification: Table top: Made of 25mm thick prelaminated particle board of approved shade. All the edges of meeting table surface shall be provided with machine pressed 2mm thick imported PVC lipping glued with hotmelt Eva glue free from any VOC. Under Structure Support: 25mm thick PLT gable end. Modesty Panel: 18mm thick 450mm ht plt modesty panel is considered.Wich is machine pressed 2mm thick imported PVC lipping glued with hotmelt Eva glue free from any VOC. Wire Management: 300mm Anodised flip up Made of Aluminum in anodised finish, which has soft closure and three way wire acess & PVC cable dump. Vertebra for wire entry.
Providing, supplying and fixing in placePost Function Lobby TABLE and Library Table Model: PER 15090 Size: 1500 x 900 x 750 Ht Specifications: Table top: Made of 25mm thick prelaminated particle board of approved shade. All the edges of cafeteria table surface shall be provided with machine pressed 2mm thick imported PVC lipping glued with hotmelt Eva glue free from any VOC. Under Structure - Table top is supported on MS Powder coated Square perform Legs which is constructed by 50 x 50 mm Sq-1.6g ERW tube acts as vertical member & supporting MS cross beam, which is made of 40 x 20 x 1.6 gauge rectangular tube and connected to legs with aluminium die cast wing connectors.
Providing, supplying and fixing in place DATA CENTER WORKSTATIONS MODEL : NEO 50 NON SHARING 1200 mm ht partition Size: 1500 / 1500 X 600 X 750 ht - 4 nos SIZE: 1200 x 600 x 750 Ht - 26 nos Specifications Made of 25mm thick prelaminated particle board of approved shade. All the edges of cafeteria table surface shall be provided with machine pressed 2mm thick imported PVC lipping glued with hotmelt Eva glue free from any VOC. Partition : Partition is made of 50mm thick NEO based system with fabric above and lamiante below the table top. Fabric magnetic and glass markers are provided for each workstation Support: 18mm thick PLB gable ends with necessary brackets Wire Management: Raceways are provided BTT only main spine and skirting (main inside) spine for power and data cable management. 65mm dia grommet hole is provided for wire access. Mobile Pedestal Pedestal are made of 18mm thick prelaminated particle board of approved shade. All the edges of pedeatal surface shall be provided with machine pressed 2mm thick imported PVC lipping glued with hotmelt Eva glue free from any VOC. With 2 drawer units and 1 filling folder unit. The drawer units are provided with finger groove handle(No visible handles) and suitable locks. Trolley for UPS
Providing, supplying and fixing in place POST FUNCTION LOBBY CENTER TABLE WALLNUT RECTANGULAR CENTRE TABLE TABLE WITH 18 MM PLB TOP AND PC SWAGE LEG SIZE: 1050W X 525D X 450HT
Providing, supplying and fixing in placePOST FUNCTION LOBBY CORNER TABLE WALLNUT CORNER TABLE TABLE WITH 18 MM PLB TOP AND PC SWAGE LEG SIZE: 600W X 450D X 450HT
Providing Supplying and fixing in position Roller Blind of 100% Polyster Zebra design as directed by the department
Providing Supplying and fixing in position Roller Blind of 100% Polyster as directed by the department
Providing Supplying and fixing in position Vertical Blind with top aluminium head- rail in natural anodized finish, with a fabric strip on the headrail. The fabric louver is provided with a width of 100mm and bottom weight in ABS plastic finish as directed by the department
AIR CONDITIONING (VRV AC) EQUIPMENTS (High Side Work) VRV/VRF Outdoor Units._Cooling Only Supply of Modular Type Out Door Units equipped with modular type high efficiency all inverter technology based hermetically sealed scroll compressors suitable for R410A refrigerant, suitable for operation on 400±5% volts, special heat exchanger with al. fin and copper tube, Centrifugal fan for condenser, electrical and microprocessor base panel and all accessories for proper functioning the unit.The Outdoor and Indoor Unit shall be integrated with special super wiring system with centralised remote control system into one common wiring.ODU having auto check function for correction eroor, auto addressing system, oil return system, soft starters for compressor motors, under voltage/over voltage trip, single phase preventers, communication card etc.The ODU shall be suitable for working on 49⁰C ambient temperature and ODU dB level Less than 70 at distance 1 Meter The Outdoor Unit complete with all interconnecting piping ,joints and U bend with in the condensing unit .Unit shall be painted two coats of clear transparent polymer coating for protection against corrosion from ambient air pollution. The COP of ODU mentioned shall be minimum 3.3 at 100% load at 35⁰C ambient temperature.Unit price shall be inclusive of Refrigerant Gas for full system, MS structure or RCC/PCC Foundation required etc. to complete the system as required as follows:- *58HP / 46.4TR (For Ground Floor)
AIR CONDITIONING (VRV AC) EQUIPMENTS (High Side Work) VRV/VRF Outdoor Units._Cooling Only Supply of Modular Type Out Door Units equipped with modular type high efficiency all inverter technology based hermetically sealed scroll compressors suitable for R410A refrigerant, suitable for operation on 400±5% volts, special heat exchanger with al. fin and copper tube, Centrifugal fan for condenser, electrical and microprocessor base panel and all accessories for proper functioning the unit.The Outdoor and Indoor Unit shall be integrated with special super wiring system with centralised remote control system into one common wiring.ODU having auto check function for correction eroor, auto addressing system, oil return system, soft starters for compressor motors, under voltage/over voltage trip, single phase preventers, communication card etc.The ODU shall be suitable for working on 49⁰C ambient temperature and ODU dB level Less than 70 at distance 1 Meter The Outdoor Unit complete with all interconnecting piping ,joints and U bend with in the condensing unit .Unit shall be painted two coats of clear transparent polymer coating for protection against corrosion from ambient air pollution. The COP of ODU mentioned shall be minimum 3.3 at 100% load at 35⁰C ambient temperature.Unit price shall be inclusive of Refrigerant Gas for full system, MS structure or RCC/PCC Foundation required etc. to complete the system as required as follows:-*88HP / 70.4TR (60HP+28HP) (For 1st Floor)88HP / 70.4TR (60HP+28HP) (For 1st Floor)
AIR CONDITIONING (VRV AC) EQUIPMENTS (High Side Work) VRV/VRF Outdoor Units._Cooling Only Supply of Modular Type Out Door Units equipped with modular type high efficiency all inverter technology based hermetically sealed scroll compressors suitable for R410A refrigerant, suitable for operation on 400±5% volts, special heat exchanger with al. fin and copper tube, Centrifugal fan for condenser, electrical and microprocessor base panel and all accessories for proper functioning the unit.The Outdoor and Indoor Unit shall be integrated with special super wiring system with centralised remote control system into one common wiring.ODU having auto check function for correction eroor, auto addressing system, oil return system, soft starters for compressor motors, under voltage/over voltage trip, single phase preventers, communication card etc.The ODU shall be suitable for working on 49⁰C ambient temperature and ODU dB level Less than 70 at distance 1 Meter The Outdoor Unit complete with all interconnecting piping ,joints and U bend with in the condensing unit .Unit shall be painted two coats of clear transparent polymer coating for protection against corrosion from ambient air pollution. The COP of ODU mentioned shall be minimum 3.3 at 100% load at 35⁰C ambient temperature.Unit price shall be inclusive of Refrigerant Gas for full system, MS structure or RCC/PCC Foundation required etc. to complete the system as required as follows:- *116HP / 92.8TR (60HP+54HP) (For 2nd Floor)
AIR CONDITIONING (VRV AC) EQUIPMENTS (High Side Work) VRV/VRF Outdoor Units._Cooling Only Supply of Modular Type Out Door Units equipped with modular type high efficiency all inverter technology based hermetically sealed scroll compressors suitable for R410A refrigerant, suitable for operation on 400±5% volts, special heat exchanger with al. fin and copper tube, Centrifugal fan for condenser, electrical and microprocessor base panel and all accessories for proper functioning the unit.The Outdoor and Indoor Unit shall be integrated with special super wiring system with centralised remote control system into one common wiring.ODU having auto check function for correction eroor, auto addressing system, oil return system, soft starters for compressor motors, under voltage/over voltage trip, single phase preventers, communication card etc.The ODU shall be suitable for working on 49⁰C ambient temperature and ODU dB level Less than 70 at distance 1 Meter The Outdoor Unit complete with all interconnecting piping ,joints and U bend with in the condensing unit .Unit shall be painted two coats of clear transparent polymer coating for protection against corrosion from ambient air pollution. The COP of ODU mentioned shall be minimum 3.3 at 100% load at 35⁰C ambient temperature.Unit price shall be inclusive of Refrigerant Gas for full system, MS structure or RCC/PCC Foundation required etc. to complete the system as required as follows:- *92HP / 73.6TR (60HP+32HP) (For 3rd Floor)
AIR CONDITIONING (VRV AC) EQUIPMENTS (High Side Work) VRV/VRF Outdoor Units._Cooling Only Supply of Modular Type Out Door Units equipped with modular type high efficiency all inverter technology based hermetically sealed scroll compressors suitable for R410A refrigerant, suitable for operation on 400±5% volts, special heat exchanger with al. fin and copper tube, Centrifugal fan for condenser, electrical and microprocessor base panel and all accessories for proper functioning the unit.The Outdoor and Indoor Unit shall be integrated with special super wiring system with centralised remote control system into one common wiring.ODU having auto check function for correction eroor, auto addressing system, oil return system, soft starters for compressor motors, under voltage/over voltage trip, single phase preventers, communication card etc.The ODU shall be suitable for working on 49⁰C ambient temperature and ODU dB level Less than 70 at distance 1 Meter The Outdoor Unit complete with all interconnecting piping ,joints and U bend with in the condensing unit .Unit shall be painted two coats of clear transparent polymer coating for protection against corrosion from ambient air pollution. The COP of ODU mentioned shall be minimum 3.3 at 100% load at 35⁰C ambient temperature.Unit price shall be inclusive of Refrigerant Gas for full system, MS structure or RCC/PCC Foundation required etc. to complete the system as required as follows:- *58HP / 46.4TR (For 4th Floor)
AIR CONDITIONING (VRV AC) EQUIPMENTS (High Side Work) VRV/VRF Outdoor Units._Cooling Only Supply of Modular Type Out Door Units equipped with modular type high efficiency all inverter technology based hermetically sealed scroll compressors suitable for R410A refrigerant, suitable for operation on 400±5% volts, special heat exchanger with al. fin and copper tube, Centrifugal fan for condenser, electrical and microprocessor base panel and all accessories for proper functioning the unit.The Outdoor and Indoor Unit shall be integrated with special super wiring system with centralised remote control system into one common wiring.ODU having auto check function for correction eroor, auto addressing system, oil return system, soft starters for compressor motors, under voltage/over voltage trip, single phase preventers, communication card etc.The ODU shall be suitable for working on 49⁰C ambient temperature and ODU dB level Less than 70 at distance 1 Meter The Outdoor Unit complete with all interconnecting piping ,joints and U bend with in the condensing unit .Unit shall be painted two coats of clear transparent polymer coating for protection against corrosion from ambient air pollution. The COP of ODU mentioned shall be minimum 3.3 at 100% load at 35⁰C ambient temperature.Unit price shall be inclusive of Refrigerant Gas for full system, MS structure or RCC/PCC Foundation required etc. to complete the system as required as follows:- *104HP / 83.2TR (54HP+50HP) (For 5th Floor)
AIR CONDITIONING (VRV AC) EQUIPMENTS (High Side Work) VRV/VRF Outdoor Units._Cooling Only Supply of Modular Type Out Door Units equipped with modular type high efficiency all inverter technology based hermetically sealed scroll compressors suitable for R410A refrigerant, suitable for operation on 400±5% volts, special heat exchanger with al. fin and copper tube, Centrifugal fan for condenser, electrical and microprocessor base panel and all accessories for proper functioning the unit.The Outdoor and Indoor Unit shall be integrated with special super wiring system with centralised remote control system into one common wiring.ODU having auto check function for correction eroor, auto addressing system, oil return system, soft starters for compressor motors, under voltage/over voltage trip, single phase preventers, communication card etc.The ODU shall be suitable for working on 49⁰C ambient temperature and ODU dB level Less than 70 at distance 1 Meter The Outdoor Unit complete with all interconnecting piping ,joints and U bend with in the condensing unit .Unit shall be painted two coats of clear transparent polymer coating for protection against corrosion from ambient air pollution. The COP of ODU mentioned shall be minimum 3.3 at 100% load at 35⁰C ambient temperature.Unit price shall be inclusive of Refrigerant Gas for full system, MS structure or RCC/PCC Foundation required etc. to complete the system as required as follows:- *94HP / 75.2TR (54HP+40HP) (For 6th Floor)
AIR CONDITIONING (VRV AC) EQUIPMENTS (High Side Work) VRV/VRF Outdoor Units._Cooling Only Supply of Modular Type Out Door Units equipped with modular type high efficiency all inverter technology based hermetically sealed scroll compressors suitable for R410A refrigerant, suitable for operation on 400±5% volts, special heat exchanger with al. fin and copper tube, Centrifugal fan for condenser, electrical and microprocessor base panel and all accessories for proper functioning the unit.The Outdoor and Indoor Unit shall be integrated with special super wiring system with centralised remote control system into one common wiring.ODU having auto check function for correction eroor, auto addressing system, oil return system, soft starters for compressor motors, under voltage/over voltage trip, single phase preventers, communication card etc.The ODU shall be suitable for working on 49⁰C ambient temperature and ODU dB level Less than 70 at distance 1 Meter The Outdoor Unit complete with all interconnecting piping ,joints and U bend with in the condensing unit .Unit shall be painted two coats of clear transparent polymer coating for protection against corrosion from ambient air pollution. The COP of ODU mentioned shall be minimum 3.3 at 100% load at 35⁰C ambient temperature.Unit price shall be inclusive of Refrigerant Gas for full system, MS structure or RCC/PCC Foundation required etc. to complete the system as required as follows:- *94HP / 75.2TR (54HP+40HP) (For 7th Floor)
AIR CONDITIONING (VRV AC) EQUIPMENTS (High Side Work) VRV/VRF Outdoor Units._Cooling Only Supply of Modular Type Out Door Units equipped with modular type high efficiency all inverter technology based hermetically sealed scroll compressors suitable for R410A refrigerant, suitable for operation on 400±5% volts, special heat exchanger with al. fin and copper tube, Centrifugal fan for condenser, electrical and microprocessor base panel and all accessories for proper functioning the unit.The Outdoor and Indoor Unit shall be integrated with special super wiring system with centralised remote control system into one common wiring.ODU having auto check function for correction eroor, auto addressing system, oil return system, soft starters for compressor motors, under voltage/over voltage trip, single phase preventers, communication card etc.The ODU shall be suitable for working on 49⁰C ambient temperature and ODU dB level Less than 70 at distance 1 Meter The Outdoor Unit complete with all interconnecting piping ,joints and U bend with in the condensing unit .Unit shall be painted two coats of clear transparent polymer coating for protection against corrosion from ambient air pollution. The COP of ODU mentioned shall be minimum 3.3 at 100% load at 35⁰C ambient temperature.Unit price shall be inclusive of Refrigerant Gas for full system, MS structure or RCC/PCC Foundation required etc. to complete the system as required as follows:- *60HP / 48.0TR (For 8th Floor)
AIR CONDITIONING (VRV AC) EQUIPMENTS (High Side Work) VRV/VRF Outdoor Units._Cooling Only Supply of Modular Type Out Door Units equipped with modular type high efficiency all inverter technology based hermetically sealed scroll compressors suitable for R410A refrigerant, suitable for operation on 400±5% volts, special heat exchanger with al. fin and copper tube, Centrifugal fan for condenser, electrical and microprocessor base panel and all accessories for proper functioning the unit.The Outdoor and Indoor Unit shall be integrated with special super wiring system with centralised remote control system into one common wiring.ODU having auto check function for correction eroor, auto addressing system, oil return system, soft starters for compressor motors, under voltage/over voltage trip, single phase preventers, communication card etc.The ODU shall be suitable for working on 49⁰C ambient temperature and ODU dB level Less than 70 at distance 1 Meter The Outdoor Unit complete with all interconnecting piping ,joints and U bend with in the condensing unit .Unit shall be painted two coats of clear transparent polymer coating for protection against corrosion from ambient air pollution. The COP of ODU mentioned shall be minimum 3.3 at 100% load at 35⁰C ambient temperature.Unit price shall be inclusive of Refrigerant Gas for full system, MS structure or RCC/PCC Foundation required etc. to complete the system as required as follows:- *36HP / 28.8TR (For 9th Floor)
VRV/VRF Indoor Units: Supply of Indoor Units suitable for operation on 220 - 240V, 50 Hz, single phase AC supply complete with cooling coil, electronic expansion valve, multi speed fan motors, dynamically balanced blowers, built in drain pump, synthetic washable plasma media filter including insulation with Cordred/cordless remote control oeration capable of varying the air flow automatically as per inside load condition with inverter technology complete as required. 4-Way Type Cassette Unit /Compact Cassette Unit with cordless remote*0.8 TR Cassette Type Unit
VRV/VRF Indoor Units: Supply of Indoor Units suitable for operation on 220 - 240V, 50 Hz, single phase AC supply complete with cooling coil, electronic expansion valve, multi speed fan motors, dynamically balanced blowers, built in drain pump, synthetic washable plasma media filter including insulation with Cordred/cordless remote control oeration capable of varying the air flow automatically as per inside load condition with inverter technology complete as required. 4-Way Type Cassette Unit /Compact Cassette Unit with cordless remote*1.0 TR Cassette Type Unit
VRV/VRF Indoor Units: Supply of Indoor Units suitable for operation on 220 - 240V, 50 Hz, single phase AC supply complete with cooling coil, electronic expansion valve, multi speed fan motors, dynamically balanced blowers, built in drain pump, synthetic washable plasma media filter including insulation with Cordred/cordless remote control oeration capable of varying the air flow automatically as per inside load condition with inverter technology complete as required. 4-Way Type Cassette Unit /Compact Cassette Unit with cordless remote*1.3 TR Cassette Type Unit
VRV/VRF Indoor Units: Supply of Indoor Units suitable for operation on 220 - 240V, 50 Hz, single phase AC supply complete with cooling coil, electronic expansion valve, multi speed fan motors, dynamically balanced blowers, built in drain pump, synthetic washable plasma media filter including insulation with Cordred/cordless remote control oeration capable of varying the air flow automatically as per inside load condition with inverter technology complete as required. 4-Way Type Cassette Unit /Compact Cassette Unit with cordless remote*1.6 TR Cassette Type Unit
VRV/VRF Indoor Units: Supply of Indoor Units suitable for operation on 220 - 240V, 50 Hz, single phase AC supply complete with cooling coil, electronic expansion valve, multi speed fan motors, dynamically balanced blowers, built in drain pump, synthetic washable plasma media filter including insulation with Cordred/cordless remote control oeration capable of varying the air flow automatically as per inside load condition with inverter technology complete as required. 4-Way Type Cassette Unit /Compact Cassette Unit with cordless remote*2.0 TR Cassette Type Unit
VRV/VRF Indoor Units: Supply of Indoor Units suitable for operation on 220 - 240V, 50 Hz, single phase AC supply complete with cooling coil, electronic expansion valve, multi speed fan motors, dynamically balanced blowers, built in drain pump, synthetic washable plasma media filter including insulation with Cordred/cordless remote control oeration capable of varying the air flow automatically as per inside load condition with inverter technology complete as required. 4-Way Type Cassette Unit /Compact Cassette Unit with cordless remote*2.6 TR Cassette Type Unit
VRV/VRF Indoor Units: Supply of Indoor Units suitable for operation on 220 - 240V, 50 Hz, single phase AC supply complete with cooling coil, electronic expansion valve, multi speed fan motors, dynamically balanced blowers, built in drain pump, synthetic washable plasma media filter including insulation with Cordred/cordless remote control oeration capable of varying the air flow automatically as per inside load condition with inverter technology complete as required. 4-Way Type Cassette Unit /Compact Cassette Unit with cordless remote*3.2 TR Cassette Type Unit
VRV/VRF Indoor Units: Supply of Indoor Units suitable for operation on 220 - 240V, 50 Hz, single phase AC supply complete with cooling coil, electronic expansion valve, multi speed fan motors, dynamically balanced blowers, built in drain pump, synthetic washable plasma media filter including insulation with Cordred/cordless remote control oeration capable of varying the air flow automatically as per inside load condition with inverter technology complete as required. 4-Way Type Cassette Unit /Compact Cassette Unit with cordless remote*4.0 TR Cassette Type Unit
VRV Hi-Wall Units with cordless remote*1.0TR
VRV Hi-Wall Units with cordless remote*1.6TR
VRV Hi-Wall Units with cordless remote*2.0 TR
Supply Installation testing comissioning of Centralised Controller for above VRV/VRF System. The system shall be capable for monitoring through PC.
LOW SIDE WORK VRV/VRF Outdoor Units._Cooling Only Installation, Testing and Commissioning of Modular Type Out Door Units equipped with modular type high efficiency all inverter technology based hermetically sealed scroll compressors suitable for R410A refrigerant, suitable for operation on 400±5% volts, special heat exchanger with al. fin and copper tube, Centrifugal fan for condenser, electrical and microprocessor base panel and all accessories for proper functioning the unit. The Outdoor and Indoor Unit shall be integrated with special super wiring system with centralised remote control system into one common wiring.ODU having auto check function for correction eroor, auto addressing system, oil return system, soft starters for compressor motors, under voltage/over voltage trip, single phase preventers, communication card etc.The ODU shall be suitable for working on 49?C ambient temperature and ODU dB level Less than 70 at distance 1 Meter The Outdoor Unit complete with all interconnecting piping ,joints and U bend with in the condensing unit .Unit shall be painted two coats of clear transparent polymer coating for protection against corrosion from ambient air pollution. The COP of ODU mentioned shall be minimum 3.3 at 100% load at 35?C ambient temperature.Unit price shall be inclusive of Refrigerant Gas for full system, MS structure or RCC/PCC Foundation required etc. to complete the system as required as follows:-*58HP / 46.4TR (For Ground Floor)
LOW SIDE WORK VRV/VRF Outdoor Units._Cooling Only Installation, Testing and Commissioning of Modular Type Out Door Units equipped with modular type high efficiency all inverter technology based hermetically sealed scroll compressors suitable for R410A refrigerant, suitable for operation on 400±5% volts, special heat exchanger with al. fin and copper tube, Centrifugal fan for condenser, electrical and microprocessor base panel and all accessories for proper functioning the unit. The Outdoor and Indoor Unit shall be integrated with special super wiring system with centralised remote control system into one common wiring.ODU having auto check function for correction eroor, auto addressing system, oil return system, soft starters for compressor motors, under voltage/over voltage trip, single phase preventers, communication card etc.The ODU shall be suitable for working on 49?C ambient temperature and ODU dB level Less than 70 at distance 1 Meter The Outdoor Unit complete with all interconnecting piping ,joints and U bend with in the condensing unit .Unit shall be painted two coats of clear transparent polymer coating for protection against corrosion from ambient air pollution. The COP of ODU mentioned shall be minimum 3.3 at 100% load at 35?C ambient temperature.Unit price shall be inclusive of Refrigerant Gas for full system, MS structure or RCC/PCC Foundation required etc. to complete the system as required as follows:-88HP / 70.4TR (60HP+28HP) (For 1st Floor)
LOW SIDE WORK VRV/VRF Outdoor Units._Cooling Only Installation, Testing and Commissioning of Modular Type Out Door Units equipped with modular type high efficiency all inverter technology based hermetically sealed scroll compressors suitable for R410A refrigerant, suitable for operation on 400±5% volts, special heat exchanger with al. fin and copper tube, Centrifugal fan for condenser, electrical and microprocessor base panel and all accessories for proper functioning the unit. The Outdoor and Indoor Unit shall be integrated with special super wiring system with centralised remote control system into one common wiring.ODU having auto check function for correction eroor, auto addressing system, oil return system, soft starters for compressor motors, under voltage/over voltage trip, single phase preventers, communication card etc.The ODU shall be suitable for working on 49?C ambient temperature and ODU dB level Less than 70 at distance 1 Meter The Outdoor Unit complete with all interconnecting piping ,joints and U bend with in the condensing unit .Unit shall be painted two coats of clear transparent polymer coating for protection against corrosion from ambient air pollution. The COP of ODU mentioned shall be minimum 3.3 at 100% load at 35?C ambient temperature.Unit price shall be inclusive of Refrigerant Gas for full system, MS structure or RCC/PCC Foundation required etc. to complete the system as required as follows:-*116HP / 92.8TR (60HP+54HP) (For 2nd Floor)
LOW SIDE WORK VRV/VRF Outdoor Units._Cooling Only Installation, Testing and Commissioning of Modular Type Out Door Units equipped with modular type high efficiency all inverter technology based hermetically sealed scroll compressors suitable for R410A refrigerant, suitable for operation on 400±5% volts, special heat exchanger with al. fin and copper tube, Centrifugal fan for condenser, electrical and microprocessor base panel and all accessories for proper functioning the unit. The Outdoor and Indoor Unit shall be integrated with special super wiring system with centralised remote control system into one common wiring.ODU having auto check function for correction eroor, auto addressing system, oil return system, soft starters for compressor motors, under voltage/over voltage trip, single phase preventers, communication card etc.The ODU shall be suitable for working on 49?C ambient temperature and ODU dB level Less than 70 at distance 1 Meter The Outdoor Unit complete with all interconnecting piping ,joints and U bend with in the condensing unit .Unit shall be painted two coats of clear transparent polymer coating for protection against corrosion from ambient air pollution. The COP of ODU mentioned shall be minimum 3.3 at 100% load at 35?C ambient temperature.Unit price shall be inclusive of Refrigerant Gas for full system, MS structure or RCC/PCC Foundation required etc. to complete the system as required as follows:-*92HP / 73.6TR (60HP+32HP) (For 3rd Floor)
LOW SIDE WORK VRV/VRF Outdoor Units._Cooling Only Installation, Testing and Commissioning of Modular Type Out Door Units equipped with modular type high efficiency all inverter technology based hermetically sealed scroll compressors suitable for R410A refrigerant, suitable for operation on 400±5% volts, special heat exchanger with al. fin and copper tube, Centrifugal fan for condenser, electrical and microprocessor base panel and all accessories for proper functioning the unit. The Outdoor and Indoor Unit shall be integrated with special super wiring system with centralised remote control system into one common wiring.ODU having auto check function for correction eroor, auto addressing system, oil return system, soft starters for compressor motors, under voltage/over voltage trip, single phase preventers, communication card etc.The ODU shall be suitable for working on 49?C ambient temperature and ODU dB level Less than 70 at distance 1 Meter The Outdoor Unit complete with all interconnecting piping ,joints and U bend with in the condensing unit .Unit shall be painted two coats of clear transparent polymer coating for protection against corrosion from ambient air pollution. The COP of ODU mentioned shall be minimum 3.3 at 100% load at 35?C ambient temperature.Unit price shall be inclusive of Refrigerant Gas for full system, MS structure or RCC/PCC Foundation required etc. to complete the system as required as follows:-*58HP / 46.4TR (For 4th Floor)
LOW SIDE WORK VRV/VRF Outdoor Units._Cooling Only Installation, Testing and Commissioning of Modular Type Out Door Units equipped with modular type high efficiency all inverter technology based hermetically sealed scroll compressors suitable for R410A refrigerant, suitable for operation on 400±5% volts, special heat exchanger with al. fin and copper tube, Centrifugal fan for condenser, electrical and microprocessor base panel and all accessories for proper functioning the unit. The Outdoor and Indoor Unit shall be integrated with special super wiring system with centralised remote control system into one common wiring.ODU having auto check function for correction eroor, auto addressing system, oil return system, soft starters for compressor motors, under voltage/over voltage trip, single phase preventers, communication card etc.The ODU shall be suitable for working on 49?C ambient temperature and ODU dB level Less than 70 at distance 1 Meter The Outdoor Unit complete with all interconnecting piping ,joints and U bend with in the condensing unit .Unit shall be painted two coats of clear transparent polymer coating for protection against corrosion from ambient air pollution. The COP of ODU mentioned shall be minimum 3.3 at 100% load at 35?C ambient temperature.Unit price shall be inclusive of Refrigerant Gas for full system, MS structure or RCC/PCC Foundation required etc. to complete the system as required as follows:-*104HP / 83.2TR (54HP+50HP) (For 5th Floor)
LOW SIDE WORK VRV/VRF Outdoor Units._Cooling Only Installation, Testing and Commissioning of Modular Type Out Door Units equipped with modular type high efficiency all inverter technology based hermetically sealed scroll compressors suitable for R410A refrigerant, suitable for operation on 400±5% volts, special heat exchanger with al. fin and copper tube, Centrifugal fan for condenser, electrical and microprocessor base panel and all accessories for proper functioning the unit. The Outdoor and Indoor Unit shall be integrated with special super wiring system with centralised remote control system into one common wiring.ODU having auto check function for correction eroor, auto addressing system, oil return system, soft starters for compressor motors, under voltage/over voltage trip, single phase preventers, communication card etc.The ODU shall be suitable for working on 49?C ambient temperature and ODU dB level Less than 70 at distance 1 Meter The Outdoor Unit complete with all interconnecting piping ,joints and U bend with in the condensing unit .Unit shall be painted two coats of clear transparent polymer coating for protection against corrosion from ambient air pollution. The COP of ODU mentioned shall be minimum 3.3 at 100% load at 35?C ambient temperature.Unit price shall be inclusive of Refrigerant Gas for full system, MS structure or RCC/PCC Foundation required etc. to complete the system as required as follows:-*94HP / 75.2TR (54HP+40HP) (For 6th Floor)
LOW SIDE WORK VRV/VRF Outdoor Units._Cooling Only Installation, Testing and Commissioning of Modular Type Out Door Units equipped with modular type high efficiency all inverter technology based hermetically sealed scroll compressors suitable for R410A refrigerant, suitable for operation on 400±5% volts, special heat exchanger with al. fin and copper tube, Centrifugal fan for condenser, electrical and microprocessor base panel and all accessories for proper functioning the unit. The Outdoor and Indoor Unit shall be integrated with special super wiring system with centralised remote control system into one common wiring.ODU having auto check function for correction eroor, auto addressing system, oil return system, soft starters for compressor motors, under voltage/over voltage trip, single phase preventers, communication card etc.The ODU shall be suitable for working on 49?C ambient temperature and ODU dB level Less than 70 at distance 1 Meter The Outdoor Unit complete with all interconnecting piping ,joints and U bend with in the condensing unit .Unit shall be painted two coats of clear transparent polymer coating for protection against corrosion from ambient air pollution. The COP of ODU mentioned shall be minimum 3.3 at 100% load at 35?C ambient temperature.Unit price shall be inclusive of Refrigerant Gas for full system, MS structure or RCC/PCC Foundation required etc. to complete the system as required as follows:-*94HP / 75.2TR (54HP+40HP) (For 7th Floor)
LOW SIDE WORK VRV/VRF Outdoor Units._Cooling Only Installation, Testing and Commissioning of Modular Type Out Door Units equipped with modular type high efficiency all inverter technology based hermetically sealed scroll compressors suitable for R410A refrigerant, suitable for operation on 400±5% volts, special heat exchanger with al. fin and copper tube, Centrifugal fan for condenser, electrical and microprocessor base panel and all accessories for proper functioning the unit. The Outdoor and Indoor Unit shall be integrated with special super wiring system with centralised remote control system into one common wiring.ODU having auto check function for correction eroor, auto addressing system, oil return system, soft starters for compressor motors, under voltage/over voltage trip, single phase preventers, communication card etc.The ODU shall be suitable for working on 49?C ambient temperature and ODU dB level Less than 70 at distance 1 Meter The Outdoor Unit complete with all interconnecting piping ,joints and U bend with in the condensing unit .Unit shall be painted two coats of clear transparent polymer coating for protection against corrosion from ambient air pollution. The COP of ODU mentioned shall be minimum 3.3 at 100% load at 35?C ambient temperature.Unit price shall be inclusive of Refrigerant Gas for full system, MS structure or RCC/PCC Foundation required etc. to complete the system as required as follows:-*60HP / 48.0TR (For 8th Floor)
LOW SIDE WORK VRV/VRF Outdoor Units._Cooling Only Installation, Testing and Commissioning of Modular Type Out Door Units equipped with modular type high efficiency all inverter technology based hermetically sealed scroll compressors suitable for R410A refrigerant, suitable for operation on 400±5% volts, special heat exchanger with al. fin and copper tube, Centrifugal fan for condenser, electrical and microprocessor base panel and all accessories for proper functioning the unit. The Outdoor and Indoor Unit shall be integrated with special super wiring system with centralised remote control system into one common wiring.ODU having auto check function for correction eroor, auto addressing system, oil return system, soft starters for compressor motors, under voltage/over voltage trip, single phase preventers, communication card etc.The ODU shall be suitable for working on 49?C ambient temperature and ODU dB level Less than 70 at distance 1 Meter The Outdoor Unit complete with all interconnecting piping ,joints and U bend with in the condensing unit .Unit shall be painted two coats of clear transparent polymer coating for protection against corrosion from ambient air pollution. The COP of ODU mentioned shall be minimum 3.3 at 100% load at 35?C ambient temperature.Unit price shall be inclusive of Refrigerant Gas for full system, MS structure or RCC/PCC Foundation required etc. to complete the system as required as follows:-*36HP / 28.8TR (For 9th Floor)
VRV/VRF Indoor Units: Installation, testing and commissioning of Indoor Units suitable for operation on 220 - 240V, 50 Hz, single phase AC supply complete with cooling coil, electronic expansion valve, multi speed fan motors, dynamically balanced blowers, built in drain pump, synthetic washable plasma media filter including insulation with Cordred/cordless remote control oeration capable of varying the air flow automatically as per inside load condition with inverter technology complete as required. 4-Way Type Cassette Unit /Compact Cassette Unit with cordless remote.*0.8 TR Cassette Type Unit
VRV/VRF Indoor Units: Installation, testing and commissioning of Indoor Units suitable for operation on 220 - 240V, 50 Hz, single phase AC supply complete with cooling coil, electronic expansion valve, multi speed fan motors, dynamically balanced blowers, built in drain pump, synthetic washable plasma media filter including insulation with Cordred/cordless remote control oeration capable of varying the air flow automatically as per inside load condition with inverter technology complete as required. 4-Way Type Cassette Unit /Compact Cassette Unit with cordless remote.*1.0 TR Cassette Type Unit
VRV/VRF Indoor Units: Installation, testing and commissioning of Indoor Units suitable for operation on 220 - 240V, 50 Hz, single phase AC supply complete with cooling coil, electronic expansion valve, multi speed fan motors, dynamically balanced blowers, built in drain pump, synthetic washable plasma media filter including insulation with Cordred/cordless remote control oeration capable of varying the air flow automatically as per inside load condition with inverter technology complete as required. 4-Way Type Cassette Unit /Compact Cassette Unit with cordless remote.*1.3 TR Cassette Type Unit
VRV/VRF Indoor Units: Installation, testing and commissioning of Indoor Units suitable for operation on 220 - 240V, 50 Hz, single phase AC supply complete with cooling coil, electronic expansion valve, multi speed fan motors, dynamically balanced blowers, built in drain pump, synthetic washable plasma media filter including insulation with Cordred/cordless remote control oeration capable of varying the air flow automatically as per inside load condition with inverter technology complete as required. 4-Way Type Cassette Unit /Compact Cassette Unit with cordless remote.*2.0 TR Cassette Type Unit
VRV/VRF Indoor Units: Installation, testing and commissioning of Indoor Units suitable for operation on 220 - 240V, 50 Hz, single phase AC supply complete with cooling coil, electronic expansion valve, multi speed fan motors, dynamically balanced blowers, built in drain pump, synthetic washable plasma media filter including insulation with Cordred/cordless remote control oeration capable of varying the air flow automatically as per inside load condition with inverter technology complete as required. 4-Way Type Cassette Unit /Compact Cassette Unit with cordless remote.*2.6 TR Cassette Type Unit
VRV/VRF Indoor Units: Installation, testing and commissioning of Indoor Units suitable for operation on 220 - 240V, 50 Hz, single phase AC supply complete with cooling coil, electronic expansion valve, multi speed fan motors, dynamically balanced blowers, built in drain pump, synthetic washable plasma media filter including insulation with Cordred/cordless remote control oeration capable of varying the air flow automatically as per inside load condition with inverter technology complete as required. 4-Way Type Cassette Unit /Compact Cassette Unit with cordless remote.*3.2 TR Cassette Type Unit
VRV/VRF Indoor Units: Installation, testing and commissioning of Indoor Units suitable for operation on 220 - 240V, 50 Hz, single phase AC supply complete with cooling coil, electronic expansion valve, multi speed fan motors, dynamically balanced blowers, built in drain pump, synthetic washable plasma media filter including insulation with Cordred/cordless remote control oeration capable of varying the air flow automatically as per inside load condition with inverter technology complete as required. 4-Way Type Cassette Unit /Compact Cassette Unit with cordless remote.*4.0 TR Cassette Type Unit
VRV Hi-Wall Units with cordless remote.*1.0TR
VRV Hi-Wall Units with cordless remote.*1.6TR
VRV Hi-Wall Units with cordless remote.*2.0 TR
REFRIGERANT PIPING Variable Refrigerant Volume/Flow System & Non VRV Hiwall Units Supply,testing and commissioning of interconnecting high pressure copper refrigerant piping work suitable for refrigerant R410A/R32 duly insulated with class O elastomeric nitrile rubber type tubular insulation of density 55±10%kg/m3 between indoor & out door units. External refrigerant piping shall be laid on 16G GI covered perforated/Lader cable trays, it shall include the cost of all the fitting, insulation and all required fittings, joints etc. as per drawings of the following sizes. Piping inside occupied area and vertical shaft shall de supported using GI Hangers. The 19mm thick insulation shall be considered for 19.1mm and above dia copper pipe and 13mm thick from 15.9mm dia and below size. All exposed pipe shall have GC Cloth pasted insulation tube and cost to be included in the piping rate and cable tray is quantified separately. Price of Cable tray will be charged with item no. *41.3mm dia (1.4mm thick.)
REFRIGERANT PIPING Variable Refrigerant Volume/Flow System & Non VRV Hiwall Units Supply,testing and commissioning of interconnecting high pressure copper refrigerant piping work suitable for refrigerant R410A/R32 duly insulated with class O elastomeric nitrile rubber type tubular insulation of density 55±10%kg/m3 between indoor & out door units. External refrigerant piping shall be laid on 16G GI covered perforated/Lader cable trays, it shall include the cost of all the fitting, insulation and all required fittings, joints etc. as per drawings of the following sizes. Piping inside occupied area and vertical shaft shall de supported using GI Hangers. The 19mm thick insulation shall be considered for 19.1mm and above dia copper pipe and 13mm thick from 15.9mm dia and below size. All exposed pipe shall have GC Cloth pasted insulation tube and cost to be included in the piping rate and cable tray is quantified separately. Price of Cable tray will be charged with item no.* 34.9mm dia (1.2mm thick.)
REFRIGERANT PIPING Variable Refrigerant Volume/Flow System & Non VRV Hiwall Units Supply,testing and commissioning of interconnecting high pressure copper refrigerant piping work suitable for refrigerant R410A/R32 duly insulated with class O elastomeric nitrile rubber type tubular insulation of density 55±10%kg/m3 between indoor & out door units. External refrigerant piping shall be laid on 16G GI covered perforated/Lader cable trays, it shall include the cost of all the fitting, insulation and all required fittings, joints etc. as per drawings of the following sizes. Piping inside occupied area and vertical shaft shall de supported using GI Hangers. The 19mm thick insulation shall be considered for 19.1mm and above dia copper pipe and 13mm thick from 15.9mm dia and below size. All exposed pipe shall have GC Cloth pasted insulation tube and cost to be included in the piping rate and cable tray is quantified separately. Price of Cable tray will be charged with item no. *31.8mm dia (1.1mm thick.)
REFRIGERANT PIPING Variable Refrigerant Volume/Flow System & Non VRV Hiwall Units Supply,testing and commissioning of interconnecting high pressure copper refrigerant piping work suitable for refrigerant R410A/R32 duly insulated with class O elastomeric nitrile rubber type tubular insulation of density 55±10%kg/m3 between indoor & out door units. External refrigerant piping shall be laid on 16G GI covered perforated/Lader cable trays, it shall include the cost of all the fitting, insulation and all required fittings, joints etc. as per drawings of the following sizes. Piping inside occupied area and vertical shaft shall de supported using GI Hangers. The 19mm thick insulation shall be considered for 19.1mm and above dia copper pipe and 13mm thick from 15.9mm dia and below size. All exposed pipe shall have GC Cloth pasted insulation tube and cost to be included in the piping rate and cable tray is quantified separately. Price of Cable tray will be charged with item no.*28.6mm dia (1.0mm thick.)
REFRIGERANT PIPING Variable Refrigerant Volume/Flow System & Non VRV Hiwall Units Supply,testing and commissioning of interconnecting high pressure copper refrigerant piping work suitable for refrigerant R410A/R32 duly insulated with class O elastomeric nitrile rubber type tubular insulation of density 55±10%kg/m3 between indoor & out door units. External refrigerant piping shall be laid on 16G GI covered perforated/Lader cable trays, it shall include the cost of all the fitting, insulation and all required fittings, joints etc. as per drawings of the following sizes. Piping inside occupied area and vertical shaft shall de supported using GI Hangers. The 19mm thick insulation shall be considered for 19.1mm and above dia copper pipe and 13mm thick from 15.9mm dia and below size. All exposed pipe shall have GC Cloth pasted insulation tube and cost to be included in the piping rate and cable tray is quantified separately. Price of Cable tray will be charged with item no.*25.4mm dia (0.80mm thick.)
REFRIGERANT PIPING Variable Refrigerant Volume/Flow System & Non VRV Hiwall Units Supply,testing and commissioning of interconnecting high pressure copper refrigerant piping work suitable for refrigerant R410A/R32 duly insulated with class O elastomeric nitrile rubber type tubular insulation of density 55±10%kg/m3 between indoor & out door units. External refrigerant piping shall be laid on 16G GI covered perforated/Lader cable trays, it shall include the cost of all the fitting, insulation and all required fittings, joints etc. as per drawings of the following sizes. Piping inside occupied area and vertical shaft shall de supported using GI Hangers. The 19mm thick insulation shall be considered for 19.1mm and above dia copper pipe and 13mm thick from 15.9mm dia and below size. All exposed pipe shall have GC Cloth pasted insulation tube and cost to be included in the piping rate and cable tray is quantified separately. Price of Cable tray will be charged with item no. *22.2mm dia (0.80mm thick.)
REFRIGERANT PIPING Variable Refrigerant Volume/Flow System & Non VRV Hiwall Units Supply,testing and commissioning of interconnecting high pressure copper refrigerant piping work suitable for refrigerant R410A/R32 duly insulated with class O elastomeric nitrile rubber type tubular insulation of density 55±10%kg/m3 between indoor & out door units. External refrigerant piping shall be laid on 16G GI covered perforated/Lader cable trays, it shall include the cost of all the fitting, insulation and all required fittings, joints etc. as per drawings of the following sizes. Piping inside occupied area and vertical shaft shall de supported using GI Hangers. The 19mm thick insulation shall be considered for 19.1mm and above dia copper pipe and 13mm thick from 15.9mm dia and below size. All exposed pipe shall have GC Cloth pasted insulation tube and cost to be included in the piping rate and cable tray is quantified separately. Price of Cable tray will be charged with item no. *19.1mm dia (0.80mm thick.)
REFRIGERANT PIPING Variable Refrigerant Volume/Flow System & Non VRV Hiwall Units Supply,testing and commissioning of interconnecting high pressure copper refrigerant piping work suitable for refrigerant R410A/R32 duly insulated with class O elastomeric nitrile rubber type tubular insulation of density 55±10%kg/m3 between indoor & out door units. External refrigerant piping shall be laid on 16G GI covered perforated/Lader cable trays, it shall include the cost of all the fitting, insulation and all required fittings, joints etc. as per drawings of the following sizes. Piping inside occupied area and vertical shaft shall de supported using GI Hangers. The 19mm thick insulation shall be considered for 19.1mm and above dia copper pipe and 13mm thick from 15.9mm dia and below size. All exposed pipe shall have GC Cloth pasted insulation tube and cost to be included in the piping rate and cable tray is quantified separately. Price of Cable tray will be charged with item no. *15.9mm dia (0.80mm thick.)
REFRIGERANT PIPING Variable Refrigerant Volume/Flow System & Non VRV Hiwall Units Supply,testing and commissioning of interconnecting high pressure copper refrigerant piping work suitable for refrigerant R410A/R32 duly insulated with class O elastomeric nitrile rubber type tubular insulation of density 55±10%kg/m3 between indoor & out door units. External refrigerant piping shall be laid on 16G GI covered perforated/Lader cable trays, it shall include the cost of all the fitting, insulation and all required fittings, joints etc. as per drawings of the following sizes. Piping inside occupied area and vertical shaft shall de supported using GI Hangers. The 19mm thick insulation shall be considered for 19.1mm and above dia copper pipe and 13mm thick from 15.9mm dia and below size. All exposed pipe shall have GC Cloth pasted insulation tube and cost to be included in the piping rate and cable tray is quantified separately. Price of Cable tray will be charged with item no. *12.7mm dia (0.80mm thick.)
REFRIGERANT PIPING Variable Refrigerant Volume/Flow System & Non VRV Hiwall Units Supply,testing and commissioning of interconnecting high pressure copper refrigerant piping work suitable for refrigerant R410A/R32 duly insulated with class O elastomeric nitrile rubber type tubular insulation of density 55±10%kg/m3 between indoor & out door units. External refrigerant piping shall be laid on 16G GI covered perforated/Lader cable trays, it shall include the cost of all the fitting, insulation and all required fittings, joints etc. as per drawings of the following sizes. Piping inside occupied area and vertical shaft shall de supported using GI Hangers. The 19mm thick insulation shall be considered for 19.1mm and above dia copper pipe and 13mm thick from 15.9mm dia and below size. All exposed pipe shall have GC Cloth pasted insulation tube and cost to be included in the piping rate and cable tray is quantified separately. Price of Cable tray will be charged with item no.* 9.5mm dia (0.80mm thick.)
REFRIGERANT PIPING Variable Refrigerant Volume/Flow System & Non VRV Hiwall Units Supply,testing and commissioning of interconnecting high pressure copper refrigerant piping work suitable for refrigerant R410A/R32 duly insulated with class O elastomeric nitrile rubber type tubular insulation of density 55±10%kg/m3 between indoor & out door units. External refrigerant piping shall be laid on 16G GI covered perforated/Lader cable trays, it shall include the cost of all the fitting, insulation and all required fittings, joints etc. as per drawings of the following sizes. Piping inside occupied area and vertical shaft shall de supported using GI Hangers. The 19mm thick insulation shall be considered for 19.1mm and above dia copper pipe and 13mm thick from 15.9mm dia and below size. All exposed pipe shall have GC Cloth pasted insulation tube and cost to be included in the piping rate and cable tray is quantified separately. Price of Cable tray will be charged with item no. * 6.4mm dia (0.80mm thick.)
Installation Testing and commissioning of Cordless remote control
Supply,installation,testing and commissioning of copper Refnet factory febricated along with suitable insulation as per shape of the refnet as required to connect the above VRV/VRF indoor and outdoor units.
COMMUNICATION AND TRANSMISSION CABLE Supply,installation,testing and commissioning of 2C x 1.0 sqmm copper conducter flexible cable laying in PVCcunduit with bent, tee as require for communication beetween VRV/VRF IDU and ODU and also for Central remote controlling system.
DRAIN PIPING Supply,installation,testing and commissioning of CPVC drain pipes density 20Kg/m3 complete with fittigs like elbows, tees, reducers, bends, flanges, supports with 9 mm thick class - O nitrile rubber insulatiions complete with supports as per drawings and specifications of below sizes.*50 mm dia
DRAIN PIPING Supply,installation,testing and commissioning of CPVC drain pipes density 20Kg/m3 complete with fittigs like elbows, tees, reducers, bends, flanges, supports with 9 mm thick class - O nitrile rubber insulatiions complete with supports as per drawings and specifications of below sizes.*40 mm dia
DRAIN PIPING Supply,installation,testing and commissioning of CPVC drain pipes density 20Kg/m3 complete with fittigs like elbows, tees, reducers, bends, flanges, supports with 9 mm thick class - O nitrile rubber insulatiions complete with supports as per drawings and specifications of below sizes.*32 mm dia.
DRAIN PIPING Supply,installation,testing and commissioning of CPVC drain pipes density 20Kg/m3 complete with fittigs like elbows, tees, reducers, bends, flanges, supports with 9 mm thick class - O nitrile rubber insulatiions complete with supports as per drawings and specifications of below sizes.*25 mm dia
AIR DISTRIBUTION SYSTEM Supply, Febrication & Fixing of 120 GSM GS sheet metal rectangular ducting as per IS 655/SMACNA complete with turning vanes, companion flanges, support, sealing of all seams with a suitable metal sealant as per drawings.*22 G
Supply installation testing and commissioning of nitrogen flushing and pressure testing
Extra refrigerant charging and commissioning of entire system
ELECTRICAL WORKS HVAC MAIN PDB PANEL FOR ODU Supply, Installation, Testing, Comisioning of following cubicle type panels construcred from 2mm thick sheet steel enclosed separate compartment for each feeeder or feeders, front operated. rear connection indoor type(IP54), dust proof, lockable door, complete with all internal wiring, colour coading with ferruls, removal cable glands plate, bonding to earth and powder coated painting, all accessories and supporting structure. All ammeters with CT and ASS, voltmeter and energy meters and all panel components as specified. MS base frame, separate adequate cable alley for incomming and outgoing termination. All switch gear to have protection levels as specified.*TPN bus bars shall be of Aluminium and shall be sleeved. Phase bus bars shall be rated at 20% higher and neutral bus bar shall be of 50% capacity. Minimum density of Aluminium bus bars for current carrying capacity shall be 1.0 amp per square mm.*INCOMER:*"i) 1 No. 415V, 4P, MCCB, 630A, 50kA with inbiult microprocessor based release with E/F, S/C, O/L as Incomer. Provide pottential free contact to connect with fire interlocking system. ii) 1 set digital ammeter with CT, ASS. iii) 1set digital voltmeter, VSS. iv) Phase indicating lights in R-Y-B colour.*OUTGOING FEEDER :*63A 4P MCB 10kA with 'ON' indication lamp :36 Sets. 40A 4P MCB 10kA with 'ON' indication lamp :8 Sets. SPARE: 63A 4P MCB 10kA with 'ON' indication lamp :1 Set. 40A 4P MCB 10kA with 'ON' indication lamp :1 Set. 25A 4P MCB 10kA with 'ON' indication lamp :1 Set.
POWER CABLING Supply Installation Testing Comisioning of following sizes of XLPE insulated PVC sheathed Copper conductor armoured cable of 1.1 KV grade on existing cable tray / surface including saddle, clamps etc. complete as required. as per specifications given in the tender.*4C X 10 Sqmm Copper Conductor multistrand armoured cable
CABLE TERMINATION Supplying and making end termination with brass/ss double compression glands and aluminium lugs for following size of PVC insulated and PVC sheathed/ XLPE copper conductor cable of 1.1 KV grade as required.*Gland for 4C X 10 Sqmm
CABLE TERMINATION Supplying and making end termination with brass/ss double compression glands and aluminium lugs for following size of PVC insulated and PVC sheathed/ XLPE copper conductor cable of 1.1 KV grade as required.*Termination for 4C X 10 Sqmm
CABLE TRAY Supply Installation Testing Comisioning of 1.6 mm thick(upto 300mm) and 2.0mm thick(above 300mm) hot plated GI pre fabricated perforated/Lader cable trays in horizontal or vertical formation complete with duely painted MS structural supports and Necessary demarkation.*100 mm wide x 25mm Height
CABLE TRAY Supply Installation Testing Comisioning of 1.6 mm thick(upto 300mm) and 2.0mm thick(above 300mm) hot plated GI pre fabricated perforated/Lader cable trays in horizontal or vertical formation complete with duely painted MS structural supports and Necessary demarkation.*300 mm wide x 25mm Height
CABLE TRAY Supply Installation Testing Comisioning of 1.6 mm thick(upto 300mm) and 2.0mm thick(above 300mm) hot plated GI pre fabricated perforated/Lader cable trays in horizontal or vertical formation complete with duely painted MS structural supports and Necessary demarkation.*450 mm wide x 50mm Height
EARTHING Supply Installation Testing comissioning of GI Earthing along with suitable clamp & acessories for HVAC Equipment .*50 x 5 mm GI Earthing strip .
EARTHING Supply Installation Testing comissioning of GI Earthing along with suitable clamp & acessories for HVAC Equipment .*25 x 3 mm GI Earthing strip .
EARTHING Supply Installation Testing comissioning of GI Earthing along with suitable clamp & acessories for HVAC Equipment .*1C X 2.5 Sqmm Copper wire for earthing .
SITC of FOH, Passive Column Array Loudspeaker with 30 Drivers Speaker Type: Passive Column Array speaker Driver Size : 14 x 3.5" Woofer Driver & 16 x 1" Tweeter driver Impedance : 6 Ω Sensitivity : 94dB RMS Power : 400 W In-built transformer Tap : 100V / 70V upto 150W / 75W / 37.5W / 19W / 9.5W Maximum SPL : RMS - 120dB , Peak - 126dB Dispersion: 130 (H) x +3° / -11° (-4° bias)( V) degrees Frequency Response (±3 dB): 120 Hz – 22 KHz Frequency Range (-10 dB) : 90 Hz – 35 KHz Rating : IP65 Enclosure : Aluminium extrusion Powder coated perforated steel grill Included Accessories: Flying bracket, wall mount bracket, input panel cover plate and glandTannoy/ Fohhn Audio /Renkus Heinz
SITC of Delay, Passive Column Array Loudspeaker with 15 Drivers Speaker Type: Passive Column Array speaker Driver Size : 7 x 3.5" Woofer Driver & 8 x 1" Tweeter driver Impedance : 12 Ω Sensitivity : 91dB RMS Power : 200 W In-built transformer Tap : 100V / 70V upto 150W / 75W / 37.5W / 19W / 9.5W Maximum SPL : RMS - 114dB , Peak - 120dB Maximum SPL (per EN54-24) : 96 dB (4 M, through transformer) Dispersion: 130 (H) x +6 / -22( V) (-8° bias) degrees conical Frequency Response (±3 dB): 150 Hz – 30 KHz Frequency Range (-10 dB) : 110 Hz – 35 KHz Rating : IP65, EN 54-24 Certified Enclosure : Aluminium extrusion Powder coated perforated steel grill Included Accessories: Flying bracket, wall mount bracket, input panel cover plate and gland Tannoy/ Fohhn Audio /Renkus Heinz
SITC of Pan Tilt Bracket for FOH and Delay Loudspeaker Tannoy/ Fohhn Audio /Renkus Heinz
SITC of Passive dual 12" Subwoofer Speaker Type: Compact Band Pass Passive Subwoofer Driver Size : 2 x 12" LF Driver Impedance : 4 Ohms Sensitivity : 100 dB RMS Power : 800 W RMS Maximum SPL : RMS - 129dB , Peak - 135dB Dispersion: Half space Frequency Response (±3 dB): 45 Hz – 160 Hz Frequency Range (-10 dB) : 37 Hz – 200 Hz Enclosure : 15 mm (5/8") plywood Powder coated perforated steel grill Multiple Flying suspension point M10 typeTannoy/ Fohhn Audio /Renkus Heinz
Flying arrangement for Subwoofer Custom
SITC of 2-channel 3000Watt power amplifier with Precise Power Management Class D Nos. of Channel : 2 THD 20Hz-20kHz at 1 W <0.1% Signal To Noise Ratio >90 dB Channel separation at 1 kHz >75 dB Power Handling : 2 x 1500 W @ 4Ohms, 2 × 800 W @ 8 ohms Peak output voltage per channel 115 V Peak output current per channel 32 A Frequency Response : 10 Hz to 20 kHz Input impedance 10 kΩ unbalanced, 20 kΩ balanced Distortion,1/8 rated power < 0.1% Signal, per channel -30 dB, -24 dB, -18 dB, -12 dB, -9 dB, -6 dB, -3 dB, LEDs lit green/orange Inputs / link 2 x XLR & 2 x ¼ " TRS, Outputs Neutrik speakON (2 x NLT4) Labgruppen /Powersoft / Bose
SITC of DSP Processor with 10 input & 6 Line output. DANTE Audio Interface AEC Mic / Line Input: min 10 No's Line Output: min 6 No's USB Audio Interface 24Bit, 48Khz Built in Digital Audio DANTE Network with 64 x 64 Channel Frequency Response: 20Hz to 20KHz Ethernet Port: Yes RS232 connector for interfacing with 3rd party control systems Crosstalk (inter-channel @ 1 kHZ): < -75 dB Common mode rejection: Typically, -60 dB at 1 kHz Latency: <1.8ms Maximum output level: -31 dBu to +24 dBu THD+N : <0.005%, Dynamic range: > 105 dB Certifictaion: CE , FCCKlarkteknik / Symetrix / QSC
SITC of Dual Channel wireless Handheld Microphone Cardioid Dynamic Receiving System : diversity Modulation mode : FM Frequency Response : 20 Hz to 20000 Hz Total Harmonic Distortion: 0.05 % or less (at 1 kHz, ±17.5 kHz deviation) Dynamic Range 109 dB or higher Operating range: 60 m RF Power Output High: 10 mW or better No. of Channel : 10 channel Per Band Latency 3.8 ms switch function : Mute/unmute & On/OFF Accessories Included: detachable Antennas, Rack mount kit Audio Technica/ Sennheiser /Shure
SITC of Dual Channel wireless Microphone System Receiving System : diversity Modulation mode : FM Frequency Response : 20 Hz to 20000 Hz Total Harmonic Distortion: 0.05 % or less (at 1 kHz, ±17.5 kHz deviation) Dynamic Range 109 dB or higher Operating range: 60 m RF Power Output High: 10 mW or better No. of Channel : 10 channel Per Band Latency 3.8 ms switch function : Mute/unmute & On/OFF Headworn mic with 1.4 m cable Terminated with locking 4-pin connector for body-pack wireless transmitters Accessories Included: detachable Antennas, Rack mount kit Audio Technica/ Sennheiser /Shure
SITC of Cardioid condenser lavalier microphone with 55" cable terminated with locking 4-pin HRS-type connector Audio Technica/ Sennheiser /Shure
SITC of Omnidirectional condenser headworn microphone with 55" cable terminated with locking 4-pin HRS-type connector Audio Technica/ Sennheiser /Shure
18" Wired Condenser Gooseneck Microphone with ON/OFF Switch ELEMENT: Fixed-charge back plate, permanently polarized condenser Pick up Pattern: Cardioid Gooseneck Length : 18" Frequency Response: 30-20,000 Hz Impedence: 250 ohms Open Circuit Sensitivity : –39 dB (11.2 mV) re 1V at 1 Pa Maximum Input Sound Level: 139 dB SPL, 1 kHz at 1% T.H.D Dynamic Range: 115 dB, 1 kHz at Max SPL Signal-to-Noise Ratio: 70 dB, 1 kHz at 1 Pa Output Connector: Integral 3-pin XLRM-type Phantom Power Requirements: 11-52V DC, 2 mA typical Switches: Flat, roll-off Low Frequency Roll-Off: 80 Hz, 18 dB/octave RFI-shielding Complete with Base with ON/Off switch Accessories : two-stage foam windscreen included Audio Technica/ Sennheiser /Shure
INSTALLATION EQUIPMENTS Equipment Rack 600x800mm, 27U with PDU, Fans and Caster WheelsNetrack/Dlink/Valrack
INSTALLATION EQUIPMENTS PVC Doubke Insualted 4 Sq mm Speaker Cable , Krystal/Belden
INSTALLATION EQUIPMENTS PVC Doubke Insualted 2.5 Sq mm Speaker Cable ,
INSTALLATION EQUIPMENTS 22 AWG Microphone Cable Krystal/Belden
INSTALLATION EQUIPMENTS Various Connectors Neutrick / Amphenol
SITC of Analogue CLI Telephone Handset BPL/ Panasonic
SITC of P 2.9 Active LED Video Wall Display with all required cables, connectors, controller and MS Structure. Pixel Configuration: 3 in one SMD. Module Resolution (W × H): 84 × 84. Max Brightness (After Calibration, nit) : 1,000. Color Temperature (K): 3,200-9,300. Physical Pixel Density (pixels/m²): 112,896. LED Lifetime (Half Brightness): 100000 Hrs. Visual Viewing Angle (H × V): 160 × 140. 90 Degree Croner Cut. Contrast Ratio: 5,000 : 1. Processing Depth (bit): 16 (HDR10, HDR10 Pro).Certifications: CE / FCC / cTUVus / CB. Environmental certifications: RoHS / REACH. Size: 6 Mtrs x 3 Mtrs. LG/Barco/Christie
SITC of HDMI overt cat6 extender. Resolution Support: 4K@60Hz with 4.4.4. Max. Resolutions / Distance: Up to 4K@70m (CAT 6 ). Compliance: HDMI 2.0 and HDCP 2.2. Transmitter Input Ports: 1 X HDMI. Transmitter Output: 1 X RJ 45Out, 1 X HDMI. Receiver Input Port: 1 x RJ 45. Receiver Output: 1 X HDMI. Tender specific OEM Authorization should be attached. Krmaer/ATEN/Milestone Pro
SITC of Smart lectern with Wired & Wireless screen sharing, Annotation facilities on FHD 21" or better 10-point touch screen with stylus or finger, IPS type, should have motorised adjustable height. Operating System: Windows 10 or better having i5 8th Gen processor or better, 16 GB or better RAM, 512GB SSD. Should have HDMI out, Audio out, USB ports with Wi-Fi 802.11 b/g/n/ac compliant. Should have in-built speakers, 2 nos of Gooseneck Microphones with sensitivity of -40dB±2dB, input frequency of 40Hz ~ 16kHz or better. The lectern should not weigh more than 30kgs. AHA/Peoplelink
High Speed True 4K HDMI Cable with Ethernet. Connector Type: HDMI (19pin) Male to Male. Connector Platting: Gold Palted. True 4K (4096 x 2160 @ 60Hz; 3840 x 2160 @ 60Hz 4:4:4).HDMI with 3D and Deep Colour. Cable should be HDCP 2.2 Compliant. The cable should have RoHS compliance. The cable should have band radious of 90 Degree. Cable Length: 1 Mtr./3 Mtrs/5 Mtrs ATEN/Kramer/Extron
SITC of Cat 6A UTP Cable with Category : 6A UTP Solid cable. Conductor : Conductor : 23 AWG (Solid). Conductor Meta : Bare Copper. Insulation Material : HD-PE. Commercial Standards: ANSI/TIA-568.2-D, ISO/IEC 11801 A1.1, REACH and RoHS compliant Belden/D Link/Molex
Supply, Installation and Testing Commissioning of 24 Port L2 Fully Managed Switch with 24x 10/100/1000 Ethernet ports, 4x 1G SFP uplinks. (Make:- Cisco/Juniper)
Supply, Installation and Testing Commissioning of 24 Port L3 Fully Managed Switch with 24x 1G SFP Port and 4x 10G SFP Uplink Port (Make:- Cisco/Juniper)
Supply Installation and Testing Commissioning of 10G SFP Module (Make:- Cisco/Juniper)
Supply Installation and Testing Commissioning of 1G SFP Module (Make:- Cisco/Juniper)
SITC of LIU 24 PORT RACK MOUNT BLK with Splice Tray and Cable spool SCHNEIDER/LEGRAND or equivalent make as approved by the Deptt..
Supply Installation and Testing Commissioning of 4K UHD LED 55" TV(Make:- LG, SAMSUNG)
Supply Installation and testing Commissioning of Cisco WiFi PoE Access Point Dual Band 2.4G and 5G(Make :- Cisco)
Supplying ,installation, testing & commissioning of UROSET 2005 Analog Hand set ( SIEMENS or equivalent as approved by the Deptt.)
Supplying ,installation, testing & commissioning of Distribution Box 200 pairs with Krones ( SIEMENS or equivalent as approved by the Deptt.
Supplying ,installation, testing & commissioning of Distribution Box 400 pairs with Krones ( SIEMENS or equivalent as approved by the Deptt.
Supplying ,installation, testing & commissioning of SFP module for Ethernet Use .(Make:- Cisco/Juniper)
Supplying, installation, testing & commissioning of 6 zone, voice alarm controller with USB, MP3 player (including 6 zone button paging station) with seamless integration facility with main fire alarm panel for voice evacuation complete as required.
Supplying, installation, testing & commissioning of ceiling mounted loud speaker, 3/1.5 Watt in ABS enclosure complete as required.
Supplying, installation, testing & commissioning of Wall mounted loud speaker, 3/1.5 Watt in ABS enclosure complete as required.
Supplying, installation, testing & commissioning of digital audio amplifier 240 Watt, 25V rms operating at 240 volt AC supply complete as required.
Supplying, installation, testing & commissioning of Voice command keypad 6 zone, with microphone assembly complete as required.
Pressurized Mechanical ventillation system in the basement with supply duct of exhaust blowers (on Areas mechanical is required) (Considering Lower Basement Area)
ORIENTAL ENGINEERS
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid