Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.0 LAccepted-AOC RZ 1 7 167 GALI NO 6 DURGA PARK NASIRPUR SOUTH WEST DELHI DELHI 110045 | SOUTH WEST | DELHI | 110045 | ₹23.0 L Quoted ₹23.8 L | L1 | Accepted-AOC BEING LOWEST |
| 2 | L2₹29.6 L+₹5.8 L (24.5%)Rejected-Finance E 73 FF GALI NO 17B SADH NAGAR PALAM COLONY NEW DELHI 110045 | SOUTH WEST DELHI | DELHI | 110045 | ₹29.6 L+₹5.8 L (24.5%) | L2 | Rejected-Finance Being other than lowest |
| 3 | L3₹31.3 L+₹7.5 L (31.5%)Rejected-Finance RZ A2 2 CHANAKYA PLACE PART I OPP C 1A BLOCK JANAK PURI NEW DELHI 110059 | NEW DELHI | WEST DELHI | DELHI | 110059 | ₹31.3 L+₹7.5 L (31.5%) | L3 | Rejected-Finance Being other than lowest |
| 4 | L4₹32.5 L+₹8.7 L (36.6%)Rejected-Finance | ₹32.5 L+₹8.7 L (36.6%) | L4 | Rejected-Finance Being other than lowest |
| 5 | L5₹35.0 L+₹11.2 L (47.0%)Rejected-Finance 1 225 5 6 SADAR BAZAR DELHI CANTT 110010 | NEW DELHI | DELHI | 110010 | ₹35.0 L+₹11.2 L (47.0%) | L5 | Rejected-Finance Being other than lowest |
Tender Value
₹48.8 L
EMD Value
₹97,540
Closing Date
5 Feb 2024, 6:00 pmClosed
GE (EAST) DELHI CANTT-10
GE (EAST) DELHI CANTT-10
MISC REPAIR AND REPLACEMENT OF UNSERVICEABLE ITEMS PERTAINING TO DESERT COOLER, WATER COOLER, REFRIGERATORS, GEYSERS, AIR CURTAIN AND OTHER CONNECTED MISC E/M WORKS AT BASE HOSPITAL UNDER GE (EAST) DELHI CANTT-10
2024_MES_636441_2
GE/DE-102/2023-24
Open Tender
Civil Works
Item Rate
180 days
GE (EAST) DELHI CANTT-10
Class D Cat c (i)
8 documents required · 8 mandatory
₹500
GE (EAST) DELHI CANTT-10
₹97,540
Yes
24 Feb 2024
24 Jan 2024
7 Feb 2024
24 Jan 2024
5 Feb 2024
25 Jan 2024
Amount
M & L for disconnecting the electric power connection and taking out the existing unserviceable voltage stabilizer of capacity 1 to 5 KVA from the site or taking out old unsv stabilizer 1 to 5 KVA from MES store yard of AGE E/M BHDC and transporting to contractors workshop for locating the fault including checking the serviceability of electrical/electronic circuits relays and replacement of defective spare parts , reassembling after making connections, testing by applying low and high voltage input to get the 230 volts correct output and transporting back the same to MES store yard or site complete all as specified and directed by Engr-in-charge Note :- 1. Replacement of defective spares as 'Supply only' of voltage stabilizer will be measured & paid separately under relevant items and Labour charges for taking out old spares & fixing of new spares shall deemed to be included in unit rate quoted.
supply only Voltmeter (Analog) 0 to 300 volts any type shape single phase 50 Hz AC supply.
supply only Digital type Voltmeter 0 to 300 volts any type shape single phase 50 Hz AC supply.
supply only Printer circuit control card suitable for 1 to 5 KVA.
supply only Input switch/ output switch/ push on switch
supply only Indicator with neon bulbs
supply only Trigger Transformer for 1 to 5 KVA.
supply only Relay for 1 to 5 KVA voltage stabilizer
supply only Time relay and High/low voltage cut off circuit with relay suitable for 2 KVA to 5 KVA.
Taking out the burnt winding of transformer of voltage stabilizer and preparing core after cleaning by suitable cleaning agent and rewinding the transformer of voltage stabilizer with super enameld copper wire of existing gauge including varnishing, heating and refiting of capacity 1 to 5 KVA voltage stabilizer, complete all as specifies & directed by Engr-in-Charge.
M &L for disconnecting from mains and taking down for servicing of Water Cooler of Capacity 40/80, 60/120,150/150, 180/180 Ltrs/Hr or any capacity including cleaning of water tank ,cooling coil, air filters , condenser, compressors, fan motor etc with vacuum cleaner or cleaning solution including checking the serviceability of electrical/electronic circuits relays, wiring kit, thermostat switches knobs, fan and blower, etc. and keeping the Water cooler unit in satisfactory working condition after necessary servicing/ repair/ replacement of defective spares as required and installation in same location complete all as specified and as directed by Engineer-in-Charge. Note :- 1. Replacement of defective spares for making the water cooler units in satisfactory working condition will be measured & paid separately under relevant items as 'Supply only' and labour charges for taking down old spares and fixing of new spares shall deemed to be included in unit rate quoted.
Supply only Starting relay of water cooler.
Supply only Starting Capacitor 25 MFD.
Supply only Running Capacitor 10 MFD.
Supply only PVC flexible drain Hose pipe 40 mm size, and suitable length.
Supply only Condenser fan blade aluminium body.
Supply only over load protector device for water cooler any capacity.
Supply only thermostat switch for water cooler any capacity.
supply only self closing chromium plated push taps for water cooler Capacity any capacity.
M&L for disconnecting the electric & water connection of water cooler and taking out the unsv compressor of any make from water cooler capacity 40/80, 60/120, 150/150, 180/180 Ltrs/Hr, and supply installation & testing of new sealed unit compressor of similar capacity in same location alongwith test Certificate from manufacturer and cleaning of condenser by machine doing vaccum on the fully system and supply and charging of oil gas and other necessary lubricants including reconnecting the electric and water connections, transportaion & testing complete all as directed by Engr-in-charge.
M&L for disconnecting the electric & water connection of water cooler and taking out old unsv condenser fan motor from water cooler capacity 40/80, 60/120, 150/150, 180/180 Lt/Hr, and supply and fixing of new motor single phase AC 220 V of same capacity including reconnecting the electric connections and testing complete all as directed by Engr-in-Charge.
M&L for disconnecting the electric & water connection of water cooler and taking out old unsv condenser coil from water cooler capacity 40/80, 60/120, 150/150, 180/180 Lt/Hr, and new condenser coil as per existing size & patterns complete all as specified & as directed.
M&L for disconnecting the electric & water connection of water cooler and taking out old unsv evaporative coil from water cooler capacity 40/80, 60/120, 150/150, 180/180 Lt/Hr, and new evaporative coil as per existing size & patterns complete all as specified & as directed.
M&L for cleaning & removing the existing paint of water Cooler capacity 40/80, 60/120, 150/150, 180/180 Ltrs/Hr, by rubbing & preparing the surface smooth & applying one coat of zinc chrome primer and two coats of synthetic enamel paint (1st grade quality) by spray gun machine of colour required as per site complete all as specified and directed.
S&F in replacement of GI water tubing 15 mm bore, medium grade with all fittings (such as bends, elbows, tees, short plugs and union etc.) fixed on wall or floor complete all as specified and as directed.
S&F in replacement of stop valve 15mm bore dia, fancy type chromium plated with long shank and cup (concealed type), screwed both ends for iron pipe or for unions complete all as specified and as directed.
S&F in replacement of 15mm dia PTMT ball valve high pressure with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe (Minimum weight 142 gms) complete all as specified and directed.
M&L for taking down unserviceable PVC connection pipe and S&F of PVC connections pipe of 15 mm dia bore with PTMT nuts of length 900 mm complete all as specified & as directed.
Material and labour for detecting of leakages of gases in Water cooler, Refrigerator, deep freezer of any type any capacity at any location and rectifying the defect to stop the leakage by gas welding or by any other means including cutting and brazing of copper tubes testing and commissioning complete in satisfactory working condition. Note: Gas shall be measured and paid separately, as supply and charging under relevant items of this schedule.
M&L for servicing of refrigerator/ Deep freezer of 165/180/195/310/330/450 and 500 Ltrs or any capacity any type by disconnecting electric connection and taking down, cleaning of cooling coil, condenser coil, compressors, including checking the serviceability of electrical/electronic circuits relays, wiring kit, thermostat switches knobs, etc. and keeping the refrigerator/deepfreezer unit in satisfactory working condition after necessary repair/ replacement of defective spares as required complete all as specified and as directed by Engineer-in-Charge. Note : Replacement of defective spares for making the refrigerator/ Deep Freezer units in satisfactory working condition will be measured & paid separately under relevant items as 'Supply only' and Labour charges for taking out old spares and fixing of new spares shall deemed to be included in unit rate quoted.
Supply only of Thermostat switch with Knob.
Supply only of Starting relay Open type with O.L.any type for any cap..
Supply only of Copper filter single capilary pencil any type for any cap.
Supply only of vegetable tray PVC any type for any cap.
Supply ony of Defrost tray any type for any cap.
Supply only of PVC ice tray flexible any type for any cap.
Supply ony of Refrigerator bottle shelf any type for any cap.
Supply only of Waste water tray any type for any cap.
Supply only of Freezer door any type for any cap.
Supply only Door Lock any type for any cap.
Supply only Door switch any type for any cap.
Supply only Interior light fittings with bulb any type for any cap.
Supply only Door handle suitable for any type for any cap.
Supply only Refrigerator Glass shelves any type for any cap.
M&L for disconnecting from electric connection and taking down the unsv compressor unit from refrigerator/ deepfreezer of any make and type and S&F of new compressor unit suitable for 165/180/195/310/330/450 and 500 Ltrs or any capacity alongwith test certificate from manufacturer including filling of suitable refrigerant /gas, replacement of filter and put in working condition all as directed by Engineer-in-Charge. Note : The rates quoted by the contractor shall deemed to include the transportation cost from site of installation to contractor's repair workshop and back.
M&L for taking out old unsv evaporator /freezer from the refrigerator/ deepfreezer and S&F of new evaporator/freezer made out of aluminium press type of 165/180/195/310/330/450 and 500 Ltrs or any capacity with freezer frame and door including connection, complete all as specified & as directed.
M&F for shifting of water cooler/ refrigerator/ deep freezer of any type any capacity from one location to another location with fixing electic/ water connection and necessary transporation arranged by contractor for shifting complete all as specified and directed.
Taking down desert cooler of any type (Steel body/Plastic body) and any capacity from any height / floor and refixing the same in same location after repair work/ overhauling all as required at site. Note:- Repair work not included in the quoted rate.
M&L for preparation of old painted surface of desert cooler of any capacity to inner surface & outer surface and repainting the complete desert coolers i.e side panel, bracket, body & desert cooler stand with two coats of synthetic enameled paint (1st grade quality) including two coats of black water proof paint on reserve water tank including servicing & greasing of fan motor/pump complete all as specified and directed.
S&F in replacement of grass pad, approximate weight 700 - 900 gms of size 20'' or 24” sweep desert cooler complete all as specified and directed.
S&F in replacement of submersible pump motor 230 Volts , single phase, AC suitable for Plastic body/Steel body Desert cooler complete all as specified & as directed. (Make Khaitan/ USHA/ Crompton Greaves/Bajaj.)
S&F in replacement of desert cooler copper wounded kit fan motor of capacity 90 Watt complete all as specified & as directed. (Make Khaitan/ USHA/ Crompton Greaves/Bajaj.)
S&F in replacement of GI wire mesh for desert cooler pad complete all as specified and directed.
S&F in replacement of front grill for desert cooler of approved make complete, with 5 Amp switch, three speed regulator including indicator lamp complete all as specified and directed.
S&F in replacement of PVC pipe for connecting pump and water distributor of size 15 mm complete all as specified & as directed.
S&F in replacement PVC elbow for desert cooler of suitable size complete all as specified & as directed.
S&F in replacement of PVC 4 Way distribution cross for desert cooler complete all as specified & as directed.
S&F in replacement of desert coolers fan blade of 18''/ 20'' inch sweep of plastic body complete all as specified & as directed.
S&F in replacement of fan motor kit bracket sets including painting complete all as specified and directed.
S&F in replacement of switch piano flush type single pole one way 5Amp / 6 Amp 230 V for desert cooler all as directed.
S&F in replacement of 3 pin plug top 5 Amp, 230V for desert cooler complete all as specified and directed.
S&F in replacement of 3 pin plug top 15 Amp, 230V for desert cooler complete all as specified and directed.
S&F in repairs desert cooler body of size 25 inch x 25 inch x 36 inch (height) with side panels (03 Nos) fabricated out of 18 SWG PGI Sheet alongwith PVC front grill, speed regulating switch, 5 Amp piano switch and tank of depth 11 inch. Painting the complete desert cooler i.e, side panel, bracket body with two coat of synthetic enamel paint (Ist grade quality) over a coat of red oxide zinc chrome primer and two coat of black water proof paint on reserve tank complete all as specified and directed.
S&F in repair flexible copper conductor cable, 3 core PVC insulated & PVC sheathed of size 1.5sqmm complete all as specified and directed.
S&F in replacement of exhaust fan motor copper wounded having 1400 RPM, 150 watts with 500mm sweep suitable for operation on 230 volts, 50Hz, AC supply, including fan brackets/ clamps of suitable size and all fixing accessories complete all as specified & as directed.
S&F in replacement of exhaust fan motor blade of suitable site complete all as specified and directed.
Supply and fixed prefabricated MS desert cooler stand (size required as per site) for desert cooler made out of MS angle iron frame of size 25 x 25 x 4 mm in cubical shape and MS flat iron strip of size 20 mm width and 3 mm thickness to hold the legs of cooler stand at the bottom including welding and duly painted with two coat of synthetic enamelled paint over a coat of red oxide primer complete all as specified and directed.
M& L in replacement single core copper conductor, FRLS, PVC insulated unsheathed 1100 Volt grade flexible 1.5 Sqmm copper conductor drawn through concealed rigid PVC conduit complete all as specified and directed.
M& L in replacement single core copper conductor, FRLS, PVC insulated unsheathed 1100 Volt grade flexible 2.5 Sqmm copper conductor drawn through concealed rigid PVC conduit complete all as specified and directed.
M& L in replacement single core copper conductor, FRLS, PVC insulated unsheathed 1100 Volt grade flexible 4.0 Sqmm copper conductor drawn through concealed rigid PVC conduit complete all as specified and directed.
M&L for sub main wiring with 2 runs of 2.5 sqmm single core, PVC insulated & unsheathed (FR) cable 1100 Volts grade with multi stranded, copper conductor with and including concealed PVC rigid conduit medium grade with all fittings and one run of 2.5 sqmm size PVC insulated copper conductor complete all including cutting chases & making good in CM 1:3 & finishes to match with existing surface as specified and directed. (Note:- Two run of cable and earth conductor shall be measured as one length)
M&L for sub main wiring with 2 runs of 4.0 sqmm single core, PVC insulated & unsheathed (FR) cable 1100 Volts grade with multi stranded, copper conductor with and including concealed PVC rigid conduit medium grade with all fittings and one run of 4 sqmm size PVC insulated copper conductor complete including cutting chases & making good in CM 1:3 & finishes to match with existing surface all as specified and directed. (Note. Two run of cable and earth conductor shall be measured as one length).
M&L for servicing of air curtain of any capacity any type, cleanning of dirt & dust suitable pressure of air, greasing of motor hub, lubricating the bearing, tightening of loose nut-bolt, making down undesirable nosie, removing old painted surfaces and duly painted with two coat of synthetic enamelled paint over a coat of red oxide primer complete all as specified and directed.
M & L for rewinding air curtain motor of single phase any type any capacity by dismantling the electric supply, removing the burnt copper winding and rewinding the motor with appropriate gauge of super enamelled superior quality of copper wire, varnishing, heating, replacment of both ball bearing, reassembling the same and testing complete all as specified and directed by Eng-In-Charge.
S&F in replacement blower drum of air curtain, existing capacity and model complete all as specified and as directed.
S&F in replacement bearing of air curtain, existing capacity and model complete all as specified and as directed.
S&F in replacement PVC flap of air curtain, existing capacity and model complete all as specified and as directed.
S&F in replacement motor housing of air curtain, existing capacity and model complete all as specified and as directed.
M&L for shifting of air curtain by disconnecting electric connection and taking down by loose nut bolt after that necessary transporation done by contractor then fixing of air curtain with suitable fastner including eletric connection complete all as specified and directed.
Supply and charging R-22 refrigerant gas, including and after carrying out the pressure test with nitrogen and rectify the leakage in summer appliances all as specified and as directed.
Supply and charging R-134A refrigerant gas, including and after carrying out the pressure test with nitrogen and rectify the leakage in summer appliances all as specified and as directed.
Supply and charging R-410A refrigerant gas, including and after carrying out the pressure test with nitrogen and rectify the leakage in summer appliances all as specified and as directed.
Supply and charging R-32A refrigerant gas, including and after carrying out the pressure test with nitrogen and rectify the leakage in summer appliances all as specified and as directed.
M&L for servicing of window type AC of 1.0/1.5/2.0 TR capacity, of any type/make, at site /wall, comprising of taking down carefully, removing power connections and front PVC grills, air filters, cleaning, washing, removing dirt, servicing including chemical wash of cooling coil, indoor cooling unit and condenser coil and providing oil and grease to all moving parts including condensing motor, checking and making serviceable electrical connection of DB's, stabilizer, wiring of AC's as per site condition and tightening all electrical connection with thimble and replacing the spare parts of the AC units wherever required, testing & commissioning including refixing at the original position and connecting with the system complete all as specified and as directed. Notes:- Contractor shall maintain register of servicing as per format given by Engr-in-Charge duly signed by User, where the servicing of equipment carry out and produce as & when asked by Engr-in-Charge or GE.
M&L for servicing of split type AC of 1.5/2.0 TR capacity, of any type/make, at site /wall, including removing power connections and front PVC grills, air filters, cleaning, washing, removing dirt, servicing including chemical wash of cooling coil, cooling unit and condenser coil of outdoor unit, checking and making serviceable electrical connection of DB's, stabilizer, wiring of AC's as per site condition and tightening all electrical connection with thimble and replacing the spare parts of the AC units wherever required, testing & commissioning including refixing at the original position and connecting with the system complete all as specified and as directed. Notes:- (i) The cost of additional inlet/outlet copper pipes, drain pipe and electrical cord, if required and making good of surface as original by plastering/ whitewash/ colour/ distemper etc shall deemed to be included in quoted rate and no extra payment shall be made to contractor on this account. (ii) Contractor shall maintain register of servicing as per format given by Engr-in-Charge duly signed by User, where the servicing of equipment carry out and produce as & when asked by Engr-in-Charge or GE.
Supply, installation ,testing and commissioning of refrigerator of capacity 322 ltr, electric driven, single phase, minimum 3 star rating, ecofriendly refrigerant, smart inverter compressor, door cooling function, multi air flow, convertible mode, toughness glass shelf complete all as specified and directed.
Supply, installation ,testing and commissioning of refrigerator of capacity 185 ltr, electric driven, single phase, minimum 5 star rating, ecofriendly refrigerant, smart inverter compressor, multi air flow, convertible mode, toughness glass shelf complete all as specified and directed.
Supply ,installation ,testing and commissioning of water cooler , having storage capacity of 80 litres/Hr and nominal cooling capacity of 40 Litres/Hrs, electric driven (single phase), dimension (WxDxH) 540X490X1250MM, net weight 42 Kg with enclosed of Stainless steel material, R22 refrigerant complete all as specified and directed.
Supply ,installation ,testing and commissioning of water cooler , having storage capacity of 150 litres/Hr and nominal cooling capacity of 150 Litres/Hrs, electric driven (single phase), dimension (WxDxH) 695X545X1335, net weight 70 Kg with enclosed of Stainless steel material, R314A refrigerant complete all as specified and directed.
S&F in replacement indoor unit complete set, suitable for 1.5 TR split AC, consisting of blower motor, blower, wiring kit complete with display and electronic card and remote assembly, cooling coil, remoting system, plastic housing with bracket frame etc except compressor suitable for Non CFC gases all as specified and as directed. Make: Carrier/ Hitachi/ Voltas/ camipro or equivalent.
S&F in replacement indoor unit complete set, suitable for 2.0 TR split AC, consisting of blower motor, blower, wiring kit complete with display and electronic card and remote assembly, cooling coil, remoting system, plastic housing with bracket frame etc except compressor suitable for Non CFC gases all as specified and as directed. Make: Carrier/ Hitachi/ Voltas/ camipro or equivalent.
S&F in replacement outdoor unit complete set, suitable for 1.5 TR split AC, including condenser coil, blower motor, chassis, base plate complete set except compressor complete all as specified & as directed. Make: Carrier/ Hitachi/ Voltas/ camipro or equivalent.
S&F in replacement outdoor unit complete set, suitable for 2.0 TR split AC, including condenser coil, blower motor, chassis, base plate complete set except compressor complete all as specified & as directed. Make: Carrier/ Hitachi/ Voltas/ camipro or equivalent.
Supply and fixing in replacement 1.5 TR Capacity Window type Air Conditioner kit including condenser coil, blower motor, chassis, base plate complete set except compressor complete all as specified & as directed. Make: Carrier/ Hitachi/ Voltas/ camipro or equivalent.
Supply and fixing in replacement 2.0 TR Capacity Window type Air Conditioner kit including condenser coil, blower motor, chassis, base plate complete set except compressor complete all as specified & as directed. Make: Carrier/ Hitachi/ Voltas/ camipro or equivalent.
S&F Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 5.0 KVAcomplete all as specified and directed.
S&F of Air curtain of size 5 ft, dimension 1500X230X212mm, Max aie velocity 21 m/s, noise level 50-70DB, No. of blower 05, No. of motor - 03, No. of shaft - 02, 570 Watt, Phase-1 single + 2 double, RPM (Max/Min) 2700/2100, Blower type ABS, CFM 1380, insect&duct rejection 75% complete all as specified and directed. Make: Euronics, Model No : EAC 5
Attending the complaints for Water heater geyser of Capacity 25/ 35/ 50 Ltrs at different location of Base Hosp area including tracing & rectify the fault of system, incl checking incoming/outgoing hot & cold water supply connection, electric connection of geysers including replacement of unserviceable parts complete all as specified and as directed. Note: . The spare parts required for repairs shall be measured and paid separately as "Supply only" under respective item of this Schedule.
Taking down the geyser of capacity 25/30/50 from its existing position for general cleaning/overhauling and descaling the tank and assembly with suitable detergent and making fully serviceable and refixing in new/old position complete with testing complete all as specified and as directed. Note: The spare parts required for repairs/ replacement shall be measured and paid separately as "Supply only" under respective item of this Schedule.
Supply only fusible plug type (pressure valve) Air release valve complete all as specified and as directed.
Supply only air release valve (Nozzle) as per sample complete all as specified and as directed.
Supply only gasket of thickness 5 mm for geyser assembly of 06 holes/ 08 holes / 09 holes complete all as specified and as directed.
Supply only Syphon assembly of copper, 06 holes with nut bolts/stud/washer complete all as specified and as directed.
Supply only of indicating lamp green/ red for geyser rectangular type/round type complete all as specified and as directed.
Supply only inner shell of Geyser of cap 25 Litre made out of steel tank complete all as specified and as directed.
Supply only inner shell of Geyser of cap 35 Litre made out of steel tank complete all as specified and as directed.
Supply only inner shell of Geyser of cap 50 Litre made out of steel tank complete all as specified and as directed.
Supply only outer body of Geyser Capacity 25/ 35/ 50 Litre of 20 SWG MS Sheet and woolen glass duly painted complete all as specified & directed.
Supply only thermostat switch of geysers (adjustable type) temp range 35 Degree Celsius to 75 degree Celsius complete all as specified & directed. Make- THEETA/BAJAJ/RECOLD/DASPASS
Supply only heating element 1.5 KW (round type) with rubber gasket complete all as specified & directed. Make- Theeta/Bajaj /Recold/ DASPASS (As per sample)
Supply only heating element 2.0KW (round type) with rubber gasket complete all as specified & directed. Make- Theeta/Bajaj /Recold/ DASPASS (As per sample)
Supply only heating element 1.5 (triangle type) with rubber gasket complete all as specified & directed. Make- Theeta/Bajaj /Recold/ DASPASS (As per sample)
Supply only heating element 2.0 (triangle type) with rubber gasket complete all as specified & directed. Make- Theeta/Bajaj /Recold/ DASPASS (As per sample)
Supply only 15mm size PVC connection pipe 600mm long heavy duty with brass nut for hot/cold water complete all as specified & directed.
Supply only 15mm size PVC connection pipe 450mm long heavy duty with brass nut for hot/cold water complete all as specified & directed.
Supply only brass chromium plated angle valve suitable for 15 mm bore pipe complete all as specified and as directed.
Supply only 15mm size brass CP extension nipple complete all as specified & directed.
Supply only 15 mm size Brass CP Angle valve 2 in 1 complete all as specified & directed. Make-Zim/ Parko/Kingston)
S&F dash fastener mild steel 150 mm long x 10 mm dia with pin and bolts complete for hanging of geyser properly on wall and making good to the disturbed surfaces including plastering and white washing complete all as specified and as directed.
Taking down geyser from existing location, preparation of body of geyser by knotting and stopping of outer surface, repainting the complete outer surface of geyser with one coat of synthetic enamelled paint 1st quality and refixing the same on wall in existing location and writing "GE E/M BHDC" of letter size 10 mm complete all as specified and as directed.
M&L for unscrewing the nut bolt and taking out the base plate geyser assembly and copper tank making soldering and brazing of tank to stop the leakage of tank and fixing back in the position complete all as specified & directed.
S&F in repair 5 star rated vertical mounted Water heater geyser of capacity 25ltrs having Features: outer body-ABS, Safety feature-Multi function safety valve, thermostat, thermal cut-out, vitreous enamelled glass line tank with CRCA outer body with powder coated with heavy duty anode rod prevent from corrosion & permanent scaling with adjustable knob for temp setting between 30°C to 75°C, high density PUF for thermal insulation with LED power indication. Technical specifications: voltage-230V, Type-storage, Frequency-50Hz, Wattage- 2 Kilo Watts, Pressure-8 Bar, Pressure Class- Class 1 complete all as specified & directed. Make : CG/Bajaj/Havells NOTE- Old unserveciable geyser of any capacity shall be deposited at MES store yard for further disposal.
S&F in repairs PVC insulated unsheathed copper wire of size 1.50 Sqmm 3 run drawn in and including 20mm dia medium grade PVC conduit complete all as specified & directed. Note: 03 run of Copper cable 1.50 Sqmm along with 20 mm PVC conduit shall be measured as one length.
Supply & Fix in replacement sheet metal enclosure with 01 No MCB SP 25 Amp, 240 Volt, 3 pin Metal clad top and metal clad socket 20 Amp complete all as specified and as directed.
S&F Syphon assembly of copper, 09 holes with nut bolts/stud/washer complete all as specified and as directed.
S&F thermostat cut out of geysers (adjustable type) temp range 35 Degree Celsius to 75 degree Celsius complete all as specified & directed. Make- THEETA/BAJAJ/RECOLD/DASPASS
S&F of electrical backup 3 KW capacity heavy duty 18 Inch with thermostat for solar water heating system complete all as specified and directed.
S&F of solar toughness glass for solar water heating system complete all as specified and directed.
S&F of air vent with pipe & MT for solar water heating system complete all as specified and directed.
M&L servicing of for solar water heating system including solar collector brazing, soalr descaling, of 100 / 200 LPD cap any type complete all as specified and directed.
S&F of solar tube for solar water heating system of any cap any make complete all as specified and directed.
PRASAD ELECTRICALS
RUCHIKA ENGG.WORKS
DP Traders
M P TYAGI ENGINEERS AND CONTRACTORS
SANJEEV ENTERPRISES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .