ELECTRICAL
12 conditions · 1 needing a document upload
Must have valid Electrical Contractor's license in the name of Firm or Contractor.
I/we the tenderer (s) am/are signing this document after carefully reading the contents.
I/We the tenderer(s) also accept all the conditions of the tender and have signed all the pages in confirmation thereof.
I/we hereby declare that I/we have downloaded the tender documents from Indian Railway website www.ireps.gov.in . I/we have verified the content of the document from the website and there is no addition, no deletion or no alteration to the content of the tender document. In case of any discrepancy noticed at any stage i.e. evaluation of tenders, execution of work or final payment of the contract, the master copy available with the railway Administration shall be final and binding upon me/us.
I/we declare and certify that I/we have not made any misleading or false representation in the forms, statements and attachments in proof of the qualification requirements.
I/We also understand that my/our offer will be evaluated based on the documents/credentials submitted along with the offer and same shall be binding upon me/us.
I/We declare that the information and documents submitted along with the tender by me/us are correct and I/we are fully responsible for the correctness of the information and documents, submitted by us.
I/we certify that I/we the tenderer(s) is/are not blacklisted or debarred by Railways or any other Ministry / Department of Govt. of India from participation in tender on the date of submission of bids, either in individual capacity or as a HUF/ member of the partnership firm/LLP/JV/Society/Trust.
I/we understand that if the contents of the certificate submitted by us are found to be forged/false at any time during process for evaluation of tenders, it shall lead to forfeiture of the Bid Security and may also lead to any other action provided in the contract including banning of business for a period of upto two year. Further, I/we and all my/our constituents understand that my/our offer shall be summarily rejected.
I/we also understand that if the contents of the certificate submitted by us are found to be false/forged at any time after the award of the contract, it will lead to termination of the contract, along with forfeiture of Bid Security/Security Deposit and Performance guarantee and may also lead to any other action provided in the contract including banning of business for a period of upto two year.
I/We have read the clause regarding restriction on procurement from a bidder of a country which shares a land border with India and certify that I am/We are not from such a country or, if from such a country, have been registered with the competent Authority. I/We hereby certify that I/we fulfil all the requirements in this regard and am/are eligible to be considered (evidence of valid registration by the competent authority is enclosed)
9 conditions · 7 needing a document upload
In case of Sole Proprietorship Concern firm has to submit Affidavit certifying the sole Proprietorship of the firm. This affidavit shall be notarized. Or In case of a Partnership Firm, Firm has to submit (a) Notary certified copy of the Partnership Deed. (b) A copy of power of Attorney firm has to submit (duly registered as per prevailing Law) in favour of an individual to tender for the work, sign the agreement etc., and create liability against the Firm. Or In case Tenderer is a Company registered under Companies Act-2013. The tenderer shall submit: (a)The copies of MOA (Memorandum of Association)/AOA (Articles of Association) of the company.(b) A copy of Certificate of Incorporation. (c) A copy of authorization/ Power of Attorney issued by the Company (backed by the resolution of Board of Directors) in favour of the individual to sign the tender on behalf of company and create liability against the company. Or In case Tenderer is LLP (Limited Liability Partnership); If the tender is submitted on behalf of a LLP registered under LLP Act-2008, the Tenderer shall submit along with tender: (a) A copy of LLP Agreement (b) A copy of Certificate of Incorporation (c) A copy of Power of Attorney/Authorization issued by the LLP in favour of the individual to sign the tender on behalf of the LLP and create liability against the LLP. Or In case of a tenderer is registered Society and Registered trust. The tenderer shall submit: (a) A copy of certificate of registration. (b) A copy of Memorandum of Association of Society/Trust Deed (c)A copy of Power of Attorney in favour of the individual to sign the tender documents and create liability against the society/ Trust.
Goods & Services Tax (GST) registration certificate copy should be attached.
PAN Card Copy should be attached.
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
List of Plant & Machinery available on hand and proposed to be inducted and hired for the tendered work shall be submitted.
List of personnel/ organization on hand and proposed to be engaged for the tendered work shall be submitted.
Declaration or details has to be submitted by the tenderer if Employment/Partnership etc. of Retired Railway Employees working as per clause-16 of Indian Railways Standard General Conditions of Contract- April2022 (GCC-April-2022).
Tenderer has to submit an undertaking in prescribed format (Annexure 'M') that he is not blacklisted or debarred by Railways or any other Ministry / Department of Govt. of India from participation in tender on the date of opening of bids, either in individual capacity or as a member of the partnership firm or JV in which he was / is a partner/member. Concealment / wrong information in regard to above shall make the contract liable for determination under Clause 62 of the General Conditions of Contract.
Electrical General works for infrastructure improvement for reducing cycle time at WRS Raipur.
DEE-GSU-R-EL-T-04-25-26~SECR
DEE-GSU-R-EL-T-04-25-26
Open
Works - General
12 Months
Raipur, Chhattisgarh
₹0
₹57,300
8 Jan 2026
8 Dec 2025
25 Dec 2025
106 items across 2 schedules
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 24,15,232 | ||
| — | 200.00 | — | — | ||
| Supply of 4 core 185 sqmm armoured aluminum cable 1.1 KV Grade Al Conductor (E- system), PVC Sheated, Flat/round wire armoured, XLPE cable on surface or underground. | — | — | — | 1,91,600 | |
| — | 200.00 | — | — | ||
| Supply of 4 core 50 sqmm armoured aluminum cable 1.1 KV Grade Al Conductor (E- system), PVC Sheated, Flat/round wire armoured, XLPE cable on surface or underground. | — | — | — | 61,000 | |
| — | 200.00 | — | — | ||
| Supply of 4 core 150 Sqmm armoured aluminum cable 1.1KV Grade Aluminum conductor (E-system),PVC sheathed, Flat/round wire armoured, XLPE cable on surface or underground . | — | — | — | 1,54,800 | |
| — | 300.00 | — | — | ||
| Supply of 4 core 25 Sqmm armoured aluminum cable 1.1KV Grade Aluminum conductor (E-system),PVC sheathed, Flat/round wire armoured, XLPE cable on surface or underground . | — | — | — | 56,100 | |
| — | 300.00 | — | — | ||
| Supply of 3x6 Sqmm Multi stranded armoured copper cable for roof light | — | — | — | 66,000 | |
| — | 1.00 | — | — | ||
| Rate for supply of floor mounted LT Control pannel consist with 2x400A 4P MCCB 50KA breaking capacity for incoming, 06 nos 4P 200A MCCB 50KA breaking capacity , 02 nos 4P 100A MCCB 35KA breaking capacity, for outgoing complete with three phase bus bar distribution system and backup HRC fuse & Metering arrangement including three phase electronic energy meter for incomer and indication. | — | — | — | 3,61,063 | |
| — | 6.00 | — | — | ||
| supply of 62.5mm dia and 3 mtrs long Gl earth Electrode with all accessories as per the IS specification complete with making of RCC earth pit and cover plates | — | — | — | 41,496 | |
| — | 5.00 | — | — | ||
| Supply of 4P MCCB,100Amps, 25KA, with metallic encloser | — | — | — | 44,335 | |
| — | 8.00 | — | — | ||
| Supply of heavy duty Air circulator wall mounted fan 600mm, sweep 1440RPM, 230V, AC 50Hz | — | — | — | 37,272 | |
| — | 1.00 | — | — | ||
| Supply of metallic distribution board consisting with 2nos 250Amps. 4P MCCB 35KA breaking capacity for incoming & 6nos 100 A 4PMCCB 10KA breaking capacity for outgoing complete with bus -bar, HRC fuse as backup, indication, locking arrangement and three phase electronic energy meter 10-60A for incomer and all accessories. | — | — | — | 92,884 | |
| — | 8.00 | — | — | ||
| Supply, installation, testing, commissioning of 60W LED Steet light fitting with accessories. | — | — | — | 1,18,600 | |
| — | 5.00 | — | — | ||
| Supply of outdoor type 36 watt LED based street light type fitting | — | — | — | 61,160 | |
| — | 20.00 | — | — | ||
| Supply of LED Based High bay /flood Light 190 Watt(Aprox) of Input Voltage 230 ac. | — | — | — | 2,46,060 | |
| — | 25.00 | — | — | ||
| supply and erection of Danger board/caution Board 33/11/415kv as per requirement | — | — | — | 3,700 | |
| — | 22.00 | — | — | ||
| Supply of BLDC ceiling Fan 1200 mm Sweep complete, 5 star rated, 2 years warantty, confirming to IS: 374:2019 or Latest. | — | — | — | 41,800 | |
| — | 22.00 | — | — | ||
| Rate for supply of electronic step regulator for fan. | — | — | — | 6,798 | |
| — | 30.00 | — | — | ||
| Rate for supply of 16W recess mounted LED fitting suitable for 230 V, 50 Hz AC supply, type of fixture round, light source SMD LED chip as per LM80/IS:16106, Diffuser material: Polycarbonate (UV stablised), 02 year warantty. | — | — | — | 7,200 | |
| — | 12.00 | — | — | ||
| Rate for supply of 400 mm bracket mounted fan for wall mounting confirming to Indian Standard IS:555 or latest, RPM 1400, No. of blade: 03 capacitor type. | — | — | — | 16,236 | |
| — | 2.00 | — | — | ||
| Rate for supply of wall mounted 8-way metallic sub-distribution board with 01 no 100 Amps TPN MCCB, 15 Nos 32 SPMCB, bus bar and neutral link and earthing arrangement etc. | — | — | — | 39,830 | |
| — | 30.00 | — | — | ||
| Supply of 36 watt 2x2 LED based recess mounting fittings. | — | — | — | 90,690 | |
| — | 4.00 | — | — | ||
| Supply of 4-way metallic sub-distribution board with 1 no 63 A TPN MCB , 03nos 25A SPMCB & 03 nos 16 A SPMCB, bus bar and neutral link arrangement etc | — | — | — | 53,808 | |
| — | 12.00 | — | — | ||
| Supply and installation of non capacitor type propeller ac ventilating 300mm sweep, 4 pole fan exhaust. | — | — | — | 13,800 | |
| — | 10.00 | — | — | ||
| supply and Installation of HT Rubber Mats of 1mtrx2mtrs,12mm Thick (ISI mark) | — | — | — | 25,550 | |
| — | 4.00 | — | — | ||
| Submersible pump with motor 5HP/3.7 KW, 3 Ph, 415 V, 2 Pole discharge 30-210 LPM, Head 27-136 mtrs, no of stage-14, Borewell size 150 mm, Delivery size 50 mm. | — | — | — | 1,04,000 | |
| — | 400.00 | — | — | ||
| 3 Core Copper (EC Grade) cable Submersible flat cables for submersible pumps. | — | — | — | 36,000 | |
| — | 4.00 | — | — | ||
| 5 HP Starter control panel for submersible pump, overload relay range:8-14 Amp, Contactor rating 25 amp with automanual switch. | — | — | — | 14,800 | |
| — | 4.00 | — | — | ||
| Drinking water cooler 150 Litres.hour. | — | — | — | 2,56,000 | |
| — | 5.00 | — | — | ||
| Supply Erection , testing commissioning of switch socket boxes indoor type fabrication MS Fabrication powder coated box and mounted on wall /structure MS Frame and comprising of the follwing - (a)100amp 4 pole MCCB 25KA with spreder link - 1 set (b)63 3P+N+E Legrand tempra socket with plug top & 4pole MCB 63 amp-1 set (c)32 3P+N+E Legrand tempra socket with plug top & 4pole MCB 32 amp-1 set (d)32 2P+E Legrand tempra socket with plug top & Singel pole MCB 32 amp-1 set Copper Earthing Terminals-2nos The set shall be complete with interconnections to FP MCCB and MCB/Sockets using 10/6/4 sq.mm PVC Insulated copper wire. The MCCB and sockets shall be flush cover ,adequate spaces shall be kept fot connection 1 no. incomer | — | — | — | 1,72,650 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .