Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.5 LAccepted-AOC | L1 | Accepted-AOC L1 Bidder | |
| 2 | L2₹30.4 L+₹84,931 (2.87%)Rejected-AOC WZ 1391 31 B NANGAL RAYA NEW DELHI 110046 | NEW DELHI | NEW DELHI | DELHI | 110046 | L2 | Rejected-AOC L2 Bidder | |
| 3 | L3₹31.0 L+₹1.4 L (4.87%)Rejected-AOC 6 341 RATAN VIHAR NANGLOI DELHI 110041 | DELHI | WEST DELHI | DELHI | 110041 | L3 | Rejected-AOC L3 Bidder | |
| 4 | L4₹32.6 L+₹3.1 L (10.4%)Rejected-AOC | L4 | Rejected-AOC L4 Bidder | |
| 5 | L5₹33.4 L+₹3.8 L (12.9%)Rejected-AOC | L5 | Rejected-AOC L5 Bidder |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
30 May 2020, 6:00 pmClosed
GE I RND DELHI
MILITARY ENGINEER SERVICES, GARRISON ENGINEER (I) RND, LUCKNOW ROAD, TIMARPUR, DELHI-110054
REPLACEMENT OF OLD ALUMINIUM WIRING WITH COPPER WIRING AND ALLIED WORKS AT DIPR MAIN BUILDING UNDER GE I RND DELHI
2020_MES_341173_1
GE/RND-12/DLI/2020-2021
Open Tender
Civil Works
Item Rate
180 days
GE I RND DELHI
Class D, Cat b(i)
2 documents required · 2 mandatory
₹500
GE I RND DELHI
₹90,000
Yes
9 Jul 2020
27 Apr 2020
1 Jun 2020
27 Apr 2020
30 May 2020
18 May 2020
Amount
Taking down carefully point wiring aluminium (light, fan, socket, and power) complete (fittings such as switches, ceiling roses, pendent, regulators, sockets etc) and making good the disturbed surface of wall, floor etc as per existing surface complete all as specified and as directed.
M&L for point wring for one light/ceiling fan controlled by one switch with 1.5 sqmm nominal area PVC insulated and PVC unsheathed multi stranded copper conductor cable FRLSH in and including concealed PVC conduit 20 mm dia medium ISI marked, including suitable 3 mm thick new steel sunken boxes, PVC modular frame and cover plate for fixing of modular switches as per required point in that board, flush to surface including PVC insulated unsheathed 1.5 sqmm copper conductor cable FRLSH connected to common earth dolly complete including cutting, chasing, plaster work and making good the disturbed surfaces match with the existing surface complete all as specified and directed.
All as per item No 2.00 above but one light point controlled by 02 Nos two way switches.
All as per item No 2.00 above but for one socket point 5 Amp on same board.
All as per item No 2.00 above but for one socket point 5 Amp on independent board.
All as per item No 2.00 above but for one socket point out let 3 pin 15 Amp with 2.5 sqmm PVC copper conductor cable and 2.5 sqmm PVC insulated copper conductor cable as earth continuity conductor complete all as specified and directed.
M&L for point wring for one light/ceiling fan controlled by one switch with 1.5 sqmm nominal area) PVC insulated and PVC unsheathed multi stranded copper conductor cable FRLSH in and including PVC casing caping 20 mm size medium duty ISI marked, including suitable 3mm thick new steel sunken boxes, PVC modular frame and cover plate for fixing of modular switches as per required point, flush to surface including PVC insulated unsheathed 1.5 sqmm copper conductor cable FRLSH connected to common earth dolly complete including cutting, chasing the surface and then making good the surface as per existing complete all as specified and directed.
All as per item No 7.00 above but for socket point 5 Amp on same board
All as per item No 7.00 above but for one socket point 5 Amp on independent board.
All as per item No 7.00 but for one socket point out let 3 pin 15 Amp with 2.5 sqmm PVC copper conductor cable and 2.5 sqmm PVC insulated copper conductor cable as earth continuity conductor complete all as specified and directed.
S&F modular switch 6 Amps 230V AC one way complete all as specified and directed.
S&F modular switch 6 Amps 230V AC two way complete all as specified and directed.
S&F one socket modular type 5 PIN 6 Amp 230 Volts AC complete all as specified and directed.
S&F one switch and one socket modular type 3 PIN 16 Amp 230 Volts AC complete all as specified and directed.
S&F regulator for ceiling fan modular electronic step type 120watt- 2module suitable for 1200/1400mm ceiling fan complete all as specified and directed.
S&F ceiling rose surface type bakelite 65x50mm two to three terminal 230V PVC polycarbonate complete all as specified and directed.
S&F in repair of telephone socket jack RJ 11 With shutter complete all as specified and directed.
Taking down of existing Ceiling/ Exhaust fan of any size and refixing the same after repair of the fan, re-winding, painting and testing the serviceability of the fan complete all as specified and directed. Note:- Re-winding and spare part like ball bearing shall be measured and paid separately.
S&F in repair of sheet metal enclosure, single pole and neutral with two pin and earth plug and socket complete with one single pole MCB SP,C Curve type of capacity 20 Amp, 240V, 10 kA complete all as specified and directed.
S&F in repair of sheet metal enclosure, three pole and neutral with three pin and earth plug and socket complete with one Triple pole MCB, C Curve type of capacity 63 Amp, 415V, 10 kA complete all as specified and directed.
S&F in repair wiring for submain wiring along with earth wire with the 2x4 sqmm+ 1X 4 sq mm earth wire of FRLSH PVC insulated copper conductor multistranded single core cable in and including PVC concealed conduit pipe 25 mm external dia medium grade including all accessories complete all as specified and directed.
S&F in repair wiring for submain wiring along with earth wire with the 2x6 sqmm+ 1X6 sq mm earth wire of FRLSH PVC insulated copper conductor multistranded single core cable in and including PVC concealed conduit pipe 25 mm external dia medium grade including all accessories complete all as specified and directed.
S&F in repair wiring for submain wiring along with earth wire with the 4x6 sqmm+ 2X6 Sqmm earth wire of FRLSH PVC insulated copper conductor multistranded single core cable in and including PVC concealed conduit pipe 32 mm external dia medium grade including all accessories complete all as specified and directed.
S&F in repair wiring for submain wiring along with earth wire with the 4x10 Sqmm+ 2X10 Sqmm earth wire of FRLSH PVC insulated copper conductor multistranded single core cable in and including PVC concealed conduit pipe 32 mm external dia medium grade including all accessories complete all as specified and directed.
S&F in repair of LED surface mounted panel light mounting including integrated electric driver provides soft-light and glare free symmetrical illumination 2'X2', 230 volt, 50 Hz and 3 core multistranded copper conductor cable for connecting to ceiling rose complete all as specified and directed. Make:-Havells Cat part No.-PLUTOSURFA CE2X2PLS34WLED857S or equivalent in Wipro/phillips.
S&F in repair of Surface and wall mounted LED batten, extruded aluminium housing provided for efficient heat dissipation with polycarbonate diffuser & integrated electronic driver.trica batten 230 volt, 50 Hz, 22 watt and 3 core multistranded copper conductor cable for connecting to ceiling rose complete all as specified and directed. Make:Havells Cat part no-ENDURALINEARNEOBS22WLED865SPCWH or equivalent in phillips/Wipro.
S&F in repair of Surface and wall mounted LED batten, extruded aluminium housing provided for efficient heat dissipation with polycarbonate diffuser & integrated electronic driver trica batten 230 volt, 50 Hz, 20 watt and 3 core multistranded copper conductor cable for connecting to ceiling rose complete all as specified and directed. Make:- Havells Cat part no-ENDURALINEARNEOBS20WLED865SPCWH or equivalent in phillips/Wipro.
S&F in repair of LED Recess mounted down light 230 volt, 50 Hz, 15 watt including 3 core multistranded copper conductor cable for connecting to ceiling rose, including necessary alteration work in false ceiling to cover the blank space in false ceiling complete all as specified and directed. Make:-Havells Cat part no RISEDLR15WLED840S or equivalent in Wipro /phillips.
S&F in repair of unseviceable old light fitting to new LED recess mounting panel 2'×2' fitting 36W 3 core multistranded copper conductor cable and making all electric connections complete all as specified and directed. Make- Havells Cat Part No.VENUSNEOHE2X2R36WLED840PIRSENSOR or equivalent in Wipro/phillips.
S&F in repair of MCB distribution board double door vertical type made out of CRCA mild steel sheet surface with insulated material like polyester or with epoxy powder coating, TPN 8 way. 415 volts with bus bar rating 200 Amps, dust and vermin proof and IP 43 - IK 09 protection suitable for incorporation of MCCB, including grouting in the wall, cutting & chasing etc complete all as specified and directed. Make-Havells Cat No DHDLVDRWAOFO08 or equivalent make as approved.
S&F in repair of sheet metal enclosure double door SPN 8 way with 240 V rated bus bar complete all as specified and directed.
S&F in repair of MCCB four pole 415 volts 50 Hz , 125 amps, with rupturing capacity 36 KA complete all as specified and as directed.
S&F in repair of MCB SPN 63 Amp 10 KA C' series complete all as specified and directed.
S&F in repair of MCB 6 Amp to 32 Amp SP 10 KA C' series complete all as specified and directed.
S&F in repair of rigid non- metallic concealed PVC conduit of size 25mm medium grade dia inclusive of all tees, bends, elbow, reducers, bell mouth tube ends and fixing accessories such as couplers. locknuts, saddles, pipe hook etc over the surface/recess including cutting and making good with CM (1:6) complete all as specified and directed.
S&F DLP U PVC trunking system Plastic adoptable type 150x50mm with two compartment duly covered installed with suitable support joints including all accessories complete all as specified and as directed. Make: Legrand/AKG/BEC
M&L for Earthing with Galvanised iron earth plate electrode 600 x 600 & 6 mm thick buried directly in ground (earth pit not less than 2.25 metre deep below normal GL) with top of earth plate not less than 1.5 metre below GL connected to GI wire 4 mm connected to earth plate electrode by means of GI nuts, bolts & washers earth wire protected with & including 15 mm dia medium grade ISI marked GI pipe not less than 7.5 metre long all as shown in electrical plate No 3 of MES Schedule Part I, with & including; PCC 1:3:6 type C1 pit with cover of RCC 1:2:4 type B-1 reinforced with welded steel wire fabric not less than 4 Kg per Sqm watering arrangements with 20 mm dia GI medium grade pipe ISI marked , GI funnel with GI mesh, filling with mixture of common salt & charcoal with alternate layers including, necessary excavation and earth works in any type of soil, including test point, testing & commissioning complete all as specified and directed.
M&L for Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or burried in ground or drawn in conduit/pipe or any other indicated situation for loop earthing etc as required 4 mm dia GI wire complete all as specified and directed.
M&L for rewinding of ceiling fan (1200mm/1400mm), exhaust fan (400mm/450mm) with existing size/gauge wiring super enamelled copper winding wire ,insulating material, replacement of bushes, varnising, drying etc complete including taking out & refixing and testing in position complete all as specified and as directed.
Supply only suitable size of ball bearing for ceiling fan/exhaust fan.
M&L for painting of ceiling fans complete with synthetic enamel paint by spraying machine including scratching, filling cavities with filler, including preparation of surface cleaning all dust etc including marking of MES No. complete all as specified and directed.
G M CONSTRUCTION COMPANY
M/s Wazer Enterprises
Surjit and Sons
R.K ENGINEERS & CONTRACTORS
V.V CONSTRUCTIONS
Suman Uni Controllers
JM enterprises
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .